Purpose. Robot-assisted orthopaedic joint reduction offers enhanced precision and control across multiple axes of motion, enabling precise realignment according to predefined plans. However, the high levels of forces encountered may induce unintended anatomical motion and flex mechanical components. To address this, this work presents an approach that uses 2D fluoroscopic imaging to verify and readjust the 3D reduction path by tracking deviations from the planned trajectory. Methods. The proposed method involves a 3D-2D registration algorithm using a pair of fluoroscopic images, along with prior models of each body in the radiographic scene. This objective is formulated to couple and constrain multiple object poses (fibula, tibia, talus, and robot end effector), and incorporate novel methods for automatic view and hyperparameter selection to improve robustness. The algorithms were refined through cadaver studies and evaluated in a preclinical trial, employing a robotic system to manipulate a dislocated fibula. Results. Studies with cadaveric specimens highlighted the joint-specific formulation’s high registration accuracy (Δx = 0.3 ± 1.5 mm), further improved with the use of automatic view and hyperparameter selection (Δx = 0.2 ± 0.8 mm). Preclinical studies demonstrated a high deviation between the intended and the actual path of the robotic system, which was accurately captured (Δx < 1 mm) using the proposed techniques. Conclusions. The solution offers to close the loop on image-based guidance of robot-assisted joint reduction by tracking the robot and bones to dynamically correct the course. The approach uses standard clinical images and is expected to lower radiation exposure by providing 3D information and allowing the staff to stay clear of the x-ray beam.
Objective . Surgical guidewires are commonly used in placing fixation implants to stabilize fractures. Accurate positioning of these instruments is challenged by difficulties in 3D reckoning from 2D fluoroscopy. This work aims to enhance the accuracy and reduce exposure times by providing 3D navigation for guidewire placement from as little as two fluoroscopic images. Approach . Our approach combines machine learning-based segmentation with the geometric model of the imager to determine the 3D poses of guidewires. Instrument tips are encoded as individual keypoints, and the segmentation masks are processed to estimate the trajectory. Correspondence between detections in multiple views is established using the pre-calibrated system geometry, and the corresponding features are backprojected to obtain the 3D pose. Guidewire 3D directions were computed using both an analytical and an optimization-based method. The complete approach was evaluated in cadaveric specimens with respect to potential confounding effects from the imaging geometry and radiographic scene clutter due to other instruments. Main results . The detection network identified the guidewire tips within 2.2 mm and guidewire directions within 1.1°, in 2D detector coordinates. Feature correspondence rejected false detections, particularly in images with other instruments, to achieve 83% precision and 90% recall. Estimating the 3D direction via numerical optimization showed added robustness to guidewires aligned with the gantry rotation plane. Guidewire tips and directions were localized in 3D world coordinates with a median accuracy of 1.8 mm and 2.7°, respectively. Significance . The paper reports a new method for automatic 2D detection and 3D localization of guidewires from pairs of fluoroscopic images. Localized guidewires can be virtually overlaid on the patient’s pre-operative 3D scan during the intervention. Accurate pose determination for multiple guidewires from two images offers to reduce radiation dose by minimizing the need for repeated imaging and provides quantitative feedback prior to implant placement.
BACKGROUND:Indirect detection flat-panel detectors (FPDs) consisting of hydrogenated amorphous silicon (a-Si:H) thin-film transistors (TFTs) are a prevalent technology for digital x-ray imaging. However, their performance is challenged in applications requiring low exposure levels, high spatial resolution, and high frame rate. Emerging FPD designs using metal oxide TFTs may offer potential performance improvements compared to FPDs based on a-Si:H TFTs.PURPOSE:This work investigates the imaging performance of a new indium gallium zinc oxide (IGZO) TFT-based detector in 2D fluoroscopy and 3D cone-beam CT (CBCT).METHODS:The new FPD consists of a sensor array combining IGZO TFTs with a-Si:H photodiodes and a 0.7-mm thick CsI:Tl scintillator. The FPD was implemented on an x-ray imaging bench with system geometry emulating intraoperative CBCT. A conventional FPD with a-Si:H TFTs and a 0.6-mm thick CsI:Tl scintillator was similarly implemented as a basis of comparison. 2D imaging performance was characterized in terms of electronic noise, sensitivity, linearity, lag, spatial resolution (modulation transfer function, MTF), image noise (noise-power spectrum, NPS), and detective quantum efficiency (DQE) with entrance air kerma (EAK) ranging from 0.3 to 1.2 μGy. 3D imaging performance was evaluated in terms of the 3D MTF and noise-equivalent quanta (NEQ), soft-tissue contrast-to-noise ratio (CNR), and image quality evident in anthropomorphic phantoms for a range of anatomical sites and dose, with weighted air kerma, K w ${K_w}$ , ranging from 0.8 to 4.9 mGy.RESULTS:The 2D imaging performance of the IGZO-based FPD exhibited up to ∼1.7× lower electronic noise than the a-Si:H FPD at matched pixel pitch. Furthermore, the IGZO FPD exhibited ∼27% increase in mid-frequency DQE (1 mm-1 ) at matched pixel size and dose (EAK ≈ 1.0 μGy) and ∼11% increase after adjusting for differences in scintillator thickness. 2D spatial resolution was limited by the scintillator for each FPD. The IGZO-based FPD demonstrated improved 3D NEQ at all spatial frequencies in both head (≥25% increase for all dose levels) and body (≥10% increase for K w ${K_w}$ ≤2 mGy) imaging scenarios. These characteristics translated to improved low-contrast visualization in anthropomorphic phantoms, demonstrating ≥10% improvement in CNR and extension of the low-dose range for which the detector is input-quantum limited.CONCLUSION:The IGZO-based FPD demonstrated improvements in electronic noise, image lag, and NEQ that translated to measurable improvements in 2D and 3D imaging performance compared to a conventional FPD based on a-Si:H TFTs. The improvements are most beneficial for 2D or 3D imaging scenarios involving low-dose and/or high-frame rate.
Purpose: Internal fixation of pelvic fractures is a challenging task requiring the placement of instrumentation within complex three-dimensional bone corridors, typically guided by fluoroscopy. We report a system for two- and three-dimensional guidance using a drill-mounted video camera and fiducial markers with evaluation in first preclinical studies. Approach: The system uses a camera affixed to a surgical drill and multimodality (optical and radio-opaque) markers for real-time trajectory visualization in fluoroscopy and/or CT. Improvements to a previously reported prototype include hardware components (mount, camera, and fiducials) and software (including a system for detecting marker perturbation) to address practical requirements necessary for translation to clinical studies. Phantom and cadaver experiments were performed to quantify the accuracy of video-fluoroscopy and video-CT registration, the ability to detect marker perturbation, and the conformance in placing guidewires along realistic pelvic trajectories. The performance was evaluated in terms of geometric accuracy and conformance within bone corridors. Results: The studies demonstrated successful guidewire delivery in a cadaver, with a median entry point error of 1.00 mm (1.56 mm IQR) and median angular error of 1.94 deg (1.23 deg IQR). Such accuracy was sufficient to guide K-wire placement through five of the six trajectories investigated with a strong level of conformance within bone corridors. The sixth case demonstrated a cortical breach due to extrema in the registration error. The system was able to detect marker perturbations and alert the user to potential registration issues. Feasible workflows were identified for orthopedic-trauma scenarios involving emergent cases (with no preoperative imaging) or cases with preoperative CT. Conclusions: A prototype system for guidewire placement was developed providing guidance that is potentially compatible with orthopedic-trauma workflow. First preclinical (cadaver) studies demonstrated accurate guidance of K-wire placement in pelvic bone corridors and the ability to automatically detect perturbations that degrade registration accuracy. The preclinical prototype demonstrated performance and utility supporting translation to clinical studies.
Manual surgical manipulation of the tibia and fibula is necessary to properly align and reduce the space in ankle fractures involving sprain of the distal tibiofibular syndesmosis. However, manual reduction is highly variable and can result in malreduction in about half of the cases. Therefore, we are developing an image-guided robotic assistant to improve reduction accuracy. The purpose of this study is to quantify the forces associated with reduction of the ankle syndesmosis to define the requirements for our robot design. Using a cadaveric specimen, we designed a fixture jig to fix the tibia securely on the operating table. We also designed a custom fibula grasping plate to which a force–torque measuring device is attached. The surgeon manually reduced the fibula utilizing this construct while translational and rotational forces along with displacement were being measured. This was first performed on an intact ankle without ligament injury and after the syndesmosis ligaments were cut. Six manipulation techniques were performed on the three principal directions of reduction at the cadaveric ankle. The results demonstrated the maximum force applied to the lateral direction to be 96.0 N with maximum displacement of 8.5 mm, applied to the anterior–posterior direction to be 71.6 N with maximum displacement of 10.7 mm, and the maximum torque applied to external–internal rotation to be 2.5 Nm with maximum rotation of 24.6°. The specific forces needed to perform the distal tibiofibular syndesmosis manipulation are not well understood. This study quantified these manipulation forces needed along with their displacement for accurate reduction of ankle syndesmosis. This is a necessary first step to help us define the design requirements of our robotic assistance from the aspects of forces and displacements.
Purpose. Mobile C-arms capable of 2D fluoroscopy and 3D cone-beam CT (CBCT) are finding application in guidance of transbronchial lung biopsy, but unresolved deformable motion presents challenges to accurate target localization and guidance. We report the initial implementation of a method to resolve deformations via locally rigid / globally deformable 3D-2D registration for motion-compensated overlay of planning data in fluoroscopically-guided pulmonary interventions. Methods. The algorithm proceeds in 3 steps: (1) initialization by 3D-2D rigid registration of CBCT to fluoroscopy (driven by bone gradients); (2) local rigid 3D-2D registration of lung-thresholded CBCT to fluoroscopy within a region of interest (ROI) about each target location; and (3) aggregation of local rigid registrations to estimate global deformation. Several objective functions and optimizers were evaluated for soft-tissue target registration. Phantom studies were performed to determine operating parameters and assess performance with simulated lung deformation. Results. Soft-tissue thresholding and contrast enhancement improved target registration error (TRE) from 10.3 mm for conventional 3D-2D registration (driven primarily by rib gradients) to 3.8 mm using locally rigid 3D-2D registration in regions of interest about each target. The soft-tissue gradient orientation (GO) objective function was found to be superior to alternative similarity measures by de-emphasizing gradient magnitude (in favor of gradient orientation), permitting the algorithm to be better driven by soft-tissue edges. Conclusions. Registration driven by soft-tissue targets is achievable via a novel processing framework to de-emphasize non-target gradients. The proposed method could improve the accuracy of guidance in pulmonary interventions by updating target overlay in fluoroscopy.
Purpose. Target localization in pulmonary interventions (e.g. transbronchial biopsy of a lung nodule) is challenged by deformable motion and may benefit from fluoroscopic overlay of the target to provide accurate guidance. We present and evaluate a 3D–2D image registration method for fluoroscopic overlay in the presence of tissue deformation using a multi-resolution/multi-scale (MRMS) framework with an objective function that drives registration primarily by soft-tissue image gradients. Methods. The MRMS method registers 3D cone-beam CT to 2D fluoroscopy without gating of respiratory phase by coarse-to-fine resampling and global-to-local rescaling about target regions-of-interest. A variation of the gradient orientation ( GO ) similarity metric (denoted GO′ ) was developed to downweight bone gradients and drive registration via soft-tissue gradients. Performance was evaluated in terms of projection distance error at isocenter (PDEiso). Phantom studies determined nominal algorithm parameters and capture range. Preclinical studies used a freshly deceased, ventilated porcine specimen to evaluate performance in the presence of real tissue deformation and a broad range of 3D–2D image mismatch. Results. Nominal algorithm parameters were identified that provided robust performance over a broad range of motion (0–20 mm), including an adaptive parameter selection technique to accommodate unknown mismatch in respiratory phase. The GO′ metric yielded median PDEiso = 1.2 mm, compared to 6.2 mm for conventional GO. Preclinical studies with real lung deformation demonstrated median PDEiso = 1.3 mm with MRMS + GO′ registration, compared to 2.2 mm with a conventional transform. Runtime was 26 s and can be reduced to 2.5 s given a prior registration within ∼5 mm as initialization. Conclusions. MRMS registration via soft-tissue gradients achieved accurate fluoroscopic overlay in the presence of deformable lung motion. By driving registration via soft-tissue image gradients, the method avoided false local minima presented by bones and was robust to a wide range of motion magnitude.
Purpose: Pelvic fracture fixation is a challenging procedure that commonly relies on 2D fluoroscopic guidance to place guidewires within complex bone corridors. Prior work reported on a video-on-drill navigation system for guidewire insertion as a potential solution. Here, we assess performance across a range of hardware components to help guide the design of future system prototypes with respect to clinical requirements. Methods: The video-on-drill system uses a camera rigidly mounted on the drill and multimodality fiducial markers (optical and radio-opaque) to provide real-time trajectory visualization. This work reports on the selection of a new camera+lens configuration. Configurations were assessed across two cameras (referred to as the ArduCam and ELP) and five lens options (A45-A90). Clinical requirements were specified by an orthopaedic-surgeon in terms of the nominal drill operating distance (𝐷) and operating area (𝐴). Performance was evaluated in terms of the accuracy of fiducial marker pose estimation (δ𝐷), and the field of view (FOV). Results: At matched FOV, the accuracy for the ELP camera was significantly better (p < 0.01) with median δ𝐷 of 1.26 mm (1.1 mm IQR) compared to the ArduCam [median δ𝐷 of 1.85 mm (2.0 mm IQR)]. The accuracy of the A45 and A55 lens was found to be suitable (δ𝐷 < 2 mm) while providing sufficient FOV at nominal drill operating conditions. Conclusion: With respect to application requirements, the camera+lens combination (ELP+Ardu55) was identified to provide the best performance, serving as an important precursor to future design iterations of the video-on-drill system.
Purpose. Surgical placement of pelvic instrumentation is challenged by complex anatomy and narrow bone corridors, and despite heavy reliance on intraoperative fluoroscopy, trauma surgery lacks a reliable solution for 3D surgical navigation that is compatible with steep workflow requirements. We report a method that uses routinely acquired fluoroscopic images in standard workflow to automatically detect and localize orthopaedic instruments for 3D guidance. Methods. The proposed method detects, establishes correspondence of, and localizes orthopaedic devices from a pair of radiographs. Instrument detection uses Mask R-CNN for segmentation and keypoint detection, trained on 4000 cadaveric pelvic radiographs with simulated guidewires. Keypoints on individual images are corresponded using prior calibration of the imaging system to backproject, identify, and rank-order ray intersections. Estimation of 3D instrument tip and direction was evaluated on a cadaveric specimen and patient images from an IRB-approved clinical study. Results. The detection network successfully generalized to cadaver and clinical images, achieving 87% recall and 98% precision. Mean geometric accuracy in estimating instrument tip and direction was (1.9 ± 1.6) mm and (1.8 ± 1.3)°, respectively. Simulation studies demonstrated 1.1 mm median error in 3D tip and 2.3° in 3D direction estimation. Preliminary tests in cadaver and clinical images show the basic feasibility of the overall approach. Conclusions. Experimental studies demonstrate the feasibility and highlight the potential of deep learning for 3D-2D registration of orthopaedic instruments as applied in fixation of pelvic fractures. The approach is compatible with routine orthopaedic workflow, does not require additional equipment (such as surgical trackers), uses common imaging equipment (mobile C-arm fluoroscopy), and does not require vendor-specific device models.
Purpose: A method for fluoroscopic guidance of a robotic assistant is presented for instrument placement in pelvic trauma surgery. The solution uses fluoroscopic images acquired in standard clinical workflow and helps avoid repeat fluoroscopy commonly performed during implant guidance. Approach: Images acquired from a mobile C-arm are used to perform 3D-2D registration of both the patient (via patient CT) and the robot (via CAD model of a surgical instrument attached to its end effector, e.g; a drill guide), guiding the robot to target trajectories defined in the patient CT. The proposed approach avoids C-arm gantry motion, instead manipulating the robot to acquire disparate views of the instrument. Phantom and cadaver studies were performed to determine operating parameters and assess the accuracy of the proposed approach in aligning a standard drill guide instrument. Results: The proposed approach achieved average drill guide tip placement accuracy of 1.57 +/- 0.47 mm and angular alignment of 0.35 +/- 0.32 deg in phantom studies. The errors remained within 2 mm and 1 deg in cadaver experiments, comparable to the margins of errors provided by surgical trackers (but operating without the need for external tracking). Conclusions: By operating at a fixed fluoroscopic perspective and eliminating the need for encoded C-arm gantry movement, the proposed approach simplifies and expedites the registration of image-guided robotic assistants and can be used with simple, non-calibrated, non-encoded, and non-isocentric C-arm systems to accurately guide a robotic device in a manner that is compatible with the surgical workflow. (C) 2021 Society of Photo-Optical Instrumentation Engineers (SPIE)
Purpose: Percutaneous fracture fixation is a challenging procedure that requires accurate interpretation of fluoroscopic images to insert guidewires through narrow bone corridors. We present a guidance system with a video camera mounted onboard the surgical drill to achieve real-time augmentation of the drill trajectory in fluoroscopy and/or CT. Approach: The camera was mounted on the drill and calibrated with respect to the drill axis. Markers identifiable in both video and fluoroscopy are placed about the surgical field and co-registered by feature correspondences. If available, a preoperative CT can also be co-registered by 3D-2D image registration. Real-time guidance is achieved by virtual overlay of the registered drill axis on fluoroscopy or in CT. Performance was evaluated in terms of target registration error (TRE), conformance within clinically relevant pelvic bone corridors, and runtime. Results: Registration of the drill axis to fluoroscopy demonstrated median TRE of 0.9 mm and 2.0 deg when solved with two views (e.g., anteroposterior and lateral) and five markers visible in both video and fluoroscopy-more than sufficient to provide Kirschner wire (K-wire) conformance within common pelvic bone corridors. Registration accuracy was reduced when solved with a single fluoroscopic view ( TRE = 3.4 mm and 2.7 deg) but was also sufficient for K-wire conformance within pelvic bone corridors. Registration was robust with as few as four markers visible within the field of view. Runtime of the initial implementation allowed fluoroscopy overlay and/or 3D CT navigation with freehand manipulation of the drill up to 10 frames / s . Conclusions: A drill-mounted video guidance system was developed to assist with K-wire placement. Overall workflow is compatible with fluoroscopically guided orthopaedic trauma surgery and does not require markers to be placed in preoperative CT. The initial prototype demonstrates accuracy and runtime that could improve the accuracy of K-wire placement, motivating future work for translation to clinical studies.
Purpose: A method and prototype for a fluoroscopically-guided surgical robot is reported for assisting pelvic fracture fixation. The approach extends the compatibility of existing guidance methods with C-arms that are in mainstream use (without prior geometric calibration) using an online calibration of the C-arm geometry automated via registration to patient anatomy. We report the first preclinical studies of this method in cadaver for evaluation of geometric accuracy. Methods: The robot is placed over the patient within the imaging field-of-view and radiographs are acquired as the robot rotates an attached instrument. The radiographs are then used to perform an online geometric calibration via 3D-2D image registration, which solves for the intrinsic and extrinsic parameters of the C-arm imaging system with respect to the patient. The solved projective geometry is then be used to register the robot to the patient and drive the robot to planned trajectories. This method is applied to a robotic system consisting of a drill guide instrument for guidewire placement and evaluated in experiments using a cadaver specimen. Results: Robotic drill guide alignment to trajectories defined in the cadaver pelvis were accurate within 2 mm and 1° (on average) using the calibration-free approach. Conformance of trajectories within bone corridors was confirmed in cadaver by extrapolating the aligned drill guide trajectory into the cadaver pelvis. Conclusion: This study demonstrates the accuracy of image-guided robotic positioning without prior calibration of the Carm gantry, facilitating the use of surgical robots with simpler imaging devices that cannot establish or maintain an offline calibration. Future work includes testing of the system in a clinical setting with trained orthopaedic surgeons and residents.
Pelvic trauma surgical procedures rely heavily on guidance with 2D fluoroscopy views for navigation in complex bone corridors. This "fluoro-hunting" paradigm results in extended radiation exposure and possible suboptimal guidewire placement from limited visualization of the fractures site with overlapped anatomy in 2D fluoroscopy. A novel computer vision-based navigation system for freehand guidewire insertion is proposed. The navigation framework is compatible with the rapid workflow in trauma surgery and bridges the gap between intraoperative fluoroscopy and preoperative CT images. The system uses a drill-mounted camera to detect and track poses of simple multimodality (optical/radiographic) markers for registration of the drill axis to fluoroscopy and, in turn, to CT. Surgical navigation is achieved with real-time display of the drill axis position on fluoroscopy views and, optionally, in 3D on the preoperative CT. The camera was corrected for lens distortion effects and calibrated for 3D pose estimation. Custom marker jigs were constructed to calibrate the drill axis and tooltip with respect to the camera frame. A testing platform for evaluation of the navigation system was developed, including a robotic arm for precise, repeatable, placement of the drill. Experiments were conducted for hand-eye calibration between the drill-mounted camera and the robot using the Park and Martin solver. Experiments using checkerboard calibration demonstrated subpixel accuracy [-0.01 ± 0.23 px] for camera distortion correction. The drill axis was calibrated using a cylindrical model and demonstrated sub-mm accuracy [0.14 ± 0.70 mm] and sub-degree angular deviation.
Purpose. Fracture reduction is a challenging part of orthopaedic pelvic trauma procedures, resulting in poor long-term prognosis if reduction does not accurately restore natural morphology. Manual preoperative planning is performed to obtain target transformations of target bones - a process that is challenging and time-consuming even to experts within the rapid workflow of emergent care and fluoroscopically guided surgery. We report a method for fracture reduction planning using a novel image-based registration framework. Method. An objective function is designed to simultaneously register multi-body bone fragments that are preoperatively segmented via a graph-cut method to a pelvic statistical shape model (SSM) with inter-body collision constraints. An alternating optimization strategy switches between fragments alignment and SSM adaptation to solve for the fragment transformations for fracture reduction planning. The method was examined in a leave-one-out study performed over a pelvic atlas with 40 members with two-body and three-body fractures simulated in the left innominate bone with displacements ranging 0-20 mm and 0 degrees-15 degrees. Result. Experiments showed the feasibility of the registration method in both two-body and three-body fracture cases. The segmentations achieved Dice coefficient of median 0.94 (0.01 interquartile range [IQR]) and root mean square error (RMSE) of 2.93 mm (0.56 mm IQR). In two body fracture cases, fracture reduction planning yielded 3.8 mm (1.6 mm IQR) translational and 2.9 degrees (1.8 degrees IQR) rotational error. Conclusion. The method demonstrated accurate fracture reduction planning within 5 mm and shows promise for future generalization to more complicated fracture cases. The algorithm provides a novel means of planning from preoperative CT images that are already acquired in standard workflow.
Purpose: Metal artifacts remain a challenge for CBCT systems in diagnostic imaging and image-guided surgery, obscuring visualization of metal instruments and surrounding anatomy. We present a method to predict C-arm CBCT orbits that will avoid metal artifacts by acquiring projection data that is least affected by polyenergetic bias. Methods: The metal artifact avoidance (MAA) method operates with a minimum of prior information, is compatible with simple mobile C-arms that are increasingly prevalent in routine use, and is consistent with either 3D filtered backprojection (FBP), more advanced (polyenergetic) model-based image reconstruction (MBIR), and/or metal artifact reduction (MAR) post-processing methods. MAA consists of the following steps: (i) coarse localization of metal objects in the field of view (FOV) via two or more low-dose scout views, coarse backprojection, and segmentation (e.g., with a U-Net); (ii) a simple model-based prediction of metal-induced x-ray spectral shift for all source-detector vertices (gantry rotation and tilt angles) accessible by the imaging system; and (iii) definition of a source-detector orbit that minimizes the view-to-view inconsistency in spectral shift. The method was evaluated in anthropomorphic phantom study emulating pedicle screw placement in spine surgery. Results: Phantom studies confirmed that the MAA method could accurately predict tilt angles that minimize metal artifacts. The proposed U-Net segmentation method was able to localize complex distributions of metal instrumentation (over 70% Dice coefficient) with 6 low-dose scout projections acquired during routine pre-scan collision check. CBCT images acquired at MAA-prescribed tilt angles demonstrated ~50% reduction in “blooming” artifacts (measured as FWHM of the screw shaft). Geometric calibration for tilted orbits at prescribed angular increments with interpolation for intermediate values demonstrated accuracy comparable to non-tilted circular trajectories in terms of the modulation transfer function. Conclusion: The preliminary results demonstrate the ability to predict C-arm orbits that provide projection data with minimal spectral bias from metal instrumentation. Such orbits exhibit strongly reduced metal artifacts, and the projection data are compatible with additional post-processing (metal artifact reduction, MAR) methods to further reduce artifacts and/or reduce noise. Ongoing studies aim to improve the robustness of metal object localization from scout views and investigate additional benefits of non-circular C-arm trajectories.
Metal artifacts present a frequent challenge to cone-beam CT (CBCT) in image-guided surgery, obscuring visualization of metal instruments and adjacent anatomy. Recent advances in mobile C-arm systems have enabled 3D imaging capacity with non-circular orbits. We extend a previously proposed metal artifacts avoidance (MAA) method to reduce the influence of metal artifacts by prospectively defining a non-circular orbit that avoids metal-induced biases in projection domain. Accurate geometric calibration is an important challenge to accurate 3D image reconstruction for such orbits. We investigate the performance of interpolation-based calibration from a library of circular orbits for any non-circular orbit. We apply the method to non-circular scans acquired for MAA, which involves: (i) coarse 3D localization of metal objects via only two scout views using an end-to-end trained neural network; (ii) calculation of the metal-induced x-ray spectral shift for all possible views; and (iii) identification of the non-circular orbit that minimizes the variations in spectral shift. Non-circular orbits with interpolation-based geometric calibration yielded reasonably accurate 3D image reconstruction. The end-to-end neural network accurately localized metal implants with just two scout views even in complex anatomical scenes, improving Dice coefficient by ~42% compared to a more conventional cascade of separately trained U-nets. In a spine phantom with pedicle screw instrumentation, non-circular orbits identified by the MAA method reduced the magnitude of metal "blomming" artifacts (apparent width of the screw shaft) in CBCT reconstructions by ~70%. The proposed imaging and calibration methods present a practical means to improve image quality in mobile C-arm CBCT by identifying non-circular scan protocols that improve sampling and reduce metal-induced biases in the projection data.
Surgical reduction of pelvic dislocation is a challenging procedure with poor long-term prognosis if reduction does not accurately restore natural morphology. The procedure often requires long fluoroscopic exposure times and trial-and-error to achieve accurate reduction. We report a method to automatically compute the target pose of dislocated bones in preoperative CT and provide 3D guidance of reduction using routine 2D fluoroscopy. A pelvic statistical shape model (SSM) and a statistical pose model (SPM) were formed from an atlas of 40 pelvic CT images. Multi-body bone segmentation was achieved by mapping the SSM to a preoperative CT via an active shape model. The target reduction pose for the dislocated bone is estimated by fitting the poses of undislocated bones to the SPM. Intraoperatively, multiple bones are registered to fluoroscopy images via 3D-2D registration to obtain 3D pose estimates from 2D images. The method was examined in three studies: (1) a simulation study of 40 CT images simulating a range of dislocation patterns; (2) a pelvic phantom study with controlled dislocation of the left innominate bone; (3) a clinical case study investigating feasibility in images acquired during pelvic reduction surgery. Experiments investigated the accuracy of registration as a function of initialization error (capture range), image quality (radiation dose and image noise), and field of view (FOV) size. The simulation study achieved target pose estimation with translational error of median 2.3 mm (1.4 mm interquartile range, IQR) and rotational error of 2.1° (1.3° IQR). 3D-2D registration yielded 0.3 mm (0.2 mm IQR) in-plane and 0.3 mm (0.2 mm IQR) out-of-plane translational error, with in-plane capture range of ±50 mm and out-of-plane capture range of ±120 mm. The phantom study demonstrated 3D-2D target registration error of 2.5 mm (1.5 mm IQR), and the method was robust over a large dose range, down to 5 [Formula: see text]Gy/frame (an order of magnitude lower than the nominal fluoroscopic dose). The clinical feasibility study demonstrated accurate registration with both preoperative and intraoperative radiographs, yielding 3.1 mm (1.0 mm IQR) projection distance error with robust performance for FOV ranging from 340 × 340 mm2 to 170 × 170 mm2 (at the image plane). The method demonstrated accurate estimation of the target reduction pose in simulation, phantom, and a clinical feasibility study for a broad range of dislocation patterns, initialization error, dose levels, and FOV size. The system provides a novel means of guidance and assessment of pelvic reduction from routinely acquired preoperative CT and intraoperative fluoroscopy. The method has the potential to reduce radiation dose by minimizing trial-and-error and to improve outcomes by guiding more accurate reduction of joint dislocations.
Microcolumnar CsI:Tl scintillator screens have been the gold standard in X-ray imaging for many years due to their high density, high atomic number, and scintillation efficiency. The structured screens provide an improvement in performance by channeling the light to the detector, improving detection efficiency and spatial resolution. We have taken this concept a step further by laser-machining the CsI:Tl scintillator to provide pixels that match the detector pixels. This allows for still thicker CsI:Tl layers up to 700 μm pixelated with pitch of 100 μm to match CMOS flat panel pixels, thus improving X-ray absorption and resolution. We are investigating the applications of CMOS detectors with pixelated scintillators for imaging of bone microarchitecture on diagnostic Cone Beam CT (CBCT) systems to provide improved quantitative metrics for diagnosis of osteoporosis and osteoarthritis. The scintillator design includes reflective coatings applied to the laser-cut grooves to improve optical isolation between pixels. Such coatings are created by atomic layer deposition (ALD), a unique approach, which permits formation of reflectors over inter-pixel grooves with aspect ratios as high as 140:1. Here we present initial results quantifying performance gains in CMOS detector resolution and their impact on the quality of bone microstructure segmentation. We demonstrate 77% gain in spatial resolution at 2 lp/mm and extension of the limiting resolution from 3 lp/mm to 4.5 lp/mm for the CMOS detector with a pixelated screen compared to a commercial sensor. In a bench-top CBCT study emulating diagnostic systems for orthopedic applications (extremity CBCT), we achieved >0.75 correlations in metrics of trabecular microarchitecture between pixelated CsI:Tl based CBCT and gold-standard micro-CT. The pixelated scintillator is expected to have significant impact for many other applications including mammography and digital radiography, where resolution and dose efficiency (DQE) of the detector are of critical importance.
We assessed interventional radiologists' task-based image quality preferences for two- and three-dimensional images obtained with a complementary metal-oxide semiconductor (CMOS) flat-panel detector versus a hydrogenated amorphous silicon (a-Si:H) flat-panel detector. CMOS and a-Si:H detectors were implemented on identical mobile C-arms to acquire radiographic, fluoroscopic, and cone-beam computed tomography (CBCT) images of cadavers undergoing simulated interventional procedures using low- and high-dose settings. Images from both systems were displayed side by side on calibrated, diagnostic-quality displays, and three interventional radiologists evaluated task performance relevant to each image and ranked their preferences based on visibility of pertinent anatomy and interventional devices. Overall, CMOS images were preferred in fluoroscopy (p = 0.002) and CBCT (p = 0.004), at low-dose settings (p = 0.001), and for tasks associated with high levels of spatial resolution [e.g., fine anatomical details (p = 0.006) and assessment of interventional devices (p = 0.015)]. No significant difference was found for fluoroscopic imaging tasks emphasizing temporal resolution (p = 0.072), for radiography tasks (p = 0.825), when using high-dose settings (p = 0.360), or tasks involving general anatomy (p = 0.174). The image quality preferences are consistent with reported technical advantages of CMOS regarding finer pixel size and reduced electronic noise. (C) 2020 Society of Photo-Optical Instrumentation Engineers (SPIE)
PURPOSE:To characterize the radiation dose and three-dimensional (3D) imaging performance of a recently developed mobile, isocentric C-arm equipped with a flat-panel detector (FPD) for intraoperative cone-beam computed tomography (CBCT) (Cios Spin 3D, Siemens Healthineers) and to identify potential improvements in 3D imaging protocols for pertinent imaging tasks. METHODS:The C-arm features a 30 × 30 cm2 FPD and isocentric gantry with computer-controlled motorization of rotation (0-195°), angulation (±220°), and height (0-45 cm). Geometric calibration was assessed in terms of 9 degrees of freedom of the x-ray source and detector in CBCT scans, and the reproducibility of geometric calibration was evaluated. Standard and custom scan protocols were evaluated, with variation in the number of projections (100-400) and mAs per view (0.05-1.65 mAs). Image reconstruction was based on 3D filtered backprojection using "smooth," "normal," and "sharp" reconstruction filters as well as a custom, two-dimensional 2D isotropic filter. Imaging performance was evaluated in terms of uniformity, gray value correspondence with Hounsfield units (HU), contrast, noise (noise-power spectrum, NPS), spatial resolution (modulation transfer function, MTF), and noise-equivalent quanta (NEQ). Performance tradeoffs among protocols were visualized in anthropomorphic phantoms for various anatomical sites and imaging tasks. RESULTS:Geometric calibration showed a high degree of reproducibility despite ~19 mm gantry flex over a nominal semicircular orbit. The dose for a CBCT scan varied from ~0.8-4.7 mGy for head protocols to ~6-38 mGy for body protocols. The MTF was consistent with sub-mm spatial resolution, with f10 (frequency at which MTF = 10%) equal to 0.64 mm-1 , 1.0 mm-1 , and 1.5 mm-1 for smooth, standard, and sharp filters respectively. Implementation of a custom 2D isotropic filter improved CNR ~ 50-60% for both head and body protocols and provided more isotropic resolution and noise characteristics. The NPS and NEQ quantified the 3D noise performance and provided a guide to protocol selection, confirmed in images of anthropomorphic phantoms. Alternative scan protocols were identified according to body site and task - for example, lower-dose body protocols (<3 mGy) sufficient for visualization of bone structures. CONCLUSION:The studies provided objective assessment of the dose and 3D imaging performance of a new C-arm, offering an important basis for clinical deployment and a benchmark for quality assurance. Modifications to standard 3D imaging protocols were identified that may improve performance or reduce radiation dose for pertinent imaging tasks.