Everyday, approximately 800 pregnant women die from preventable causes, with 95% of these deaths occurring in low- and middle-income countries. Adolescent mothers are disproportionally affected. Hypertensive disorders, including eclampsia, contribute to around 20% of direct maternal deaths, many of which are preventable with simple, cost-effective interventions. This study aims to quantify the risk of eclampsia among adolescent mothers in low- and middle-income countries. This secondary analysis used data from three large multi-center studies within the CRADLE programme of work, conducted across ten regions in Sub-Saharan Africa, India, and Haiti. Data on eclampsia and maternal age were prospectively collected from routine sources and active case finding. The incidence rates of eclampsia were calculated, and the relative risk of eclampsia in adolescents were calculated and compared to non-adolescent mothers. Among 601,343 deliveries, 3,098 cases of eclampsia were recorded (0·51%). The incidence of eclampsia varied widely, from 22 per 10,000 deliveries in Zambia to 142 per 10,000 deliveries in Sierra Leone, a 6·5-fold variation. Adolescents accounted for 34% of eclampsia cases (1065/3098). The relative risk of eclampsia in adolescents compared to older mothers ranged from 1·50 (95% CI 1.32 to 1.83) to 3·45 (95% CI 2.71 to 4.41) across sites (p<0.0001). Adolescent mothers in low- and middle- income countries studied faced a significantly higher risk of eclampsia compared to older mothers. The reproducibility of this finding across diverse settings and time periods highlights the vulnerability of adolescent mothers to health inequalities associated with hypertensive disorders. Further research is needed to explore mechanisms underlying eclampsia in this group, independent of the severity of maternal or fetal disease. Developing targeted interventions and strategies to improve maternal and perinatal outcomes in this high-risk group should be a priority.
(Abstracted from Lancet Glob Health 2021;9:e1119–e1128) Hypertension in pregnancy (HIP) has served as a marker for increased risk of adverse pregnancy outcomes, including fetal growth restriction, stillbirth, severe maternal morbidity, and maternal mortality. Traditionally, HIP has been defined as systolic blood pressure (sBP) of ≥140 mm Hg, diastolic BP (dBP) of ≥90 mm Hg, or both.
Objectives: This study aimed to establish a correlation and strengthen the utilization of inflammatory and hematologic ratios in predicting GDM during the first trimester among Filipinos. Methods:A prospective cohort approach with 300 patients enrolled in the study.Initial CBC and 75 g OGTT results were gathered during the 1st trimester.Subsequent 75 g OGTT during their 24-28th week age of gestation were documented and classified according to IADPSG guidelines. Results:The optimal cut off points based on ROC Curve Analysis are 3.29-3.42for NLR and 985.19-1016 for PLR.The sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio and negative likelihood ratio were as follows: 0.38, 0.848, 0, 0.588, 0.542, 1.425 and 0.845 for NLR and 0.82, 0.24, 0.519, 0.571, 1.079 and 0.75 for PLR. Conclusions:A strong correlation was found between NLR and PLR, and the early detection of GDM.Findings of the study suggest that both NLR and PLR can be important markers for GDM screening in the 1st trimester.
Supplemental Digital Content is available in the text. In pregnancy in well-resourced settings, limited data suggest that higher blood pressure (BP) visit-to-visit variability may be associated with adverse pregnancy outcomes. Included were pregnant women in 22 intervention clusters of the CLIP (Community-Level Interventions for Preeclampsia) cluster randomized trials, who had received at least 2 prenatal contacts from a community health worker, including standardized BP measurement. Mixed-effects adjusted logistic regression assessed relationships between pregnancy outcomes and both BP level (median [interquartile range]) and visit-to-visit variability (SD and average real variability [ARV], adjusted for BP level), among all women and those who became hypertensive. The primary outcome was the CLIP composite of maternal and perinatal mortality and morbidity. Among 17 770 pregnancies, higher systolic and diastolic BP levels were associated with increased odds of the composite outcome per 5 mm Hg increase in BP (odds ratio [OR], 1.05 [95% CI, 1.03–1.07] and OR, 1.08 [1.06–1.11], respectively). Higher BP visit-to-visit variability was associated with increased odds, per a SD increase in BP variability measure, of (1) hypertension (systolic: OR, 2.09 [1.98–2.21] for SD and 1.52 [1.45–1.60] for ARV; diastolic: OR, 2.70 [2.54–2.87] for SD and 1.86 [1.76–1.96] for ARV); and (2) the composite outcome (systolic: OR, 1.10 [1.06–1.14] for SD and 1.06 [1.02–1.10] for ARV; diastolic: OR, 1.07 [1.03–1.11] for SD and 1.06 [1.02–1.09] for ARV). In 3 less-developed countries, higher BP level and visit-to-visit variability predicted adverse pregnancy outcomes, providing an opportunity for high-definition medicine.
Objectives: To evaluate community-based health workers' ability to identify cases of hypertension in pregnancy, safely deliver methyldopa and magnesium sulphate and make referrals when appropriate. Study design: This was part of Nigeria Community-Level Interventions for Pre-eclampsia (CLIP) cluster randomized controlled trial (NCT01911494). Community-based Health Workers (CHW) recruited pregnant women from five Local Government Areas (clusters) and used mobile health aid for clinical assessment of pre-eclampsia. Main outcome measures: The primary outcome was the number of adverse events that occurred after the administration of magnesium sulphate and/or methyldopa to pregnant women by CHWs. Findings: Of 8790 women receiving mobile health-guided care, community-based health workers in Nigeria provided 309 women with hypertension (4.2% of delivered women), and safely administered 142 doses of intramuscular magnesium sulphate. Community Heath Extension Workers (CHEWs) and nurses gave fifty-two and sixty-seven doses of intramuscular magnesium sulphate respectively, twenty-three doses were given by other health care workers (midwives, community health officers, health assistants). The high rate of administration by nurses can be explained by turf protection as well as their seniority within the health system. Also, CHEWs and nurses gave 124 doses of oral methyldopa and 126 urgent referrals were completed. There were no complications related to administration of treatment or referral.
Background Obstetric haemorrhage is the leading cause of maternal death worldwide, 99% of which occur in low and middle income countries. The majority of deaths and adverse events are associated with delays in identifying compromise and escalating care. Management of severely compromised pregnant women may require transfer to tertiary centres for specialised treatment, therefore early recognition is vital for efficient management. The CRADLE vital signs alert device accurately measures blood pressure and heart rate, calculates the shock index (heart rate divided by systolic blood pressure) and alerts the user to compromise through a traffic light system reflecting previously validated shock index thresholds. Methods This is a planned secondary analysis of data from the CRADLE-3 trial from ten clusters across Africa, India and Haiti where the device and training package were randomly introduced. Referral data were prospectively collected for a 4-week period before, and a 4-week period 3 months after implementation. Referrals from primary or secondary care facilities to higher level care for any cause were recorded. The denominator was the number of women seen for maternity care in these facilities. Results Between April 1 2016 and Nov 30th, 2017 536,223 women attended maternity care facilities. Overall, 3.7% ( n = 2784/74,828) of women seen in peripheral maternity facilities were referred to higher level care in the control period compared to 4.4% ( n = 3212/73,371) in the intervention period (OR 0.89; 0.39–2.05) (data for nine sites that were able to collect denominator). Of these 0.29% ( n = 212) pre-intervention and 0.16% ( n = 120) post-intervention were referred to higher-level facilities for maternal haemorrhage. Although overall referrals did not significantly reduce there was a significant reduction in referrals for obstetric haemorrhage (OR 0.56 (0.39–0.65) following introduction of the device with homogeneity (i-squared 26.1) between sites. There was no increase in any bleeding-related morbidity (maternal death or emergency hysterectomy). Conclusions Referrals for obstetric haemorrhage reduced following implementation of the CRADLE Vital Signs Alert Device, occurring without an increase in maternal death or emergency hysterectomy. This demonstrates the potential benefit of shock index in management pathways for obstetric haemorrhage and targeting limited resources in low- middle- income settings. Trial registration This study is registered with the ISRCTN registry, number ISRCTN41244132 (02/02/2016).
•CHWs in Ogun state, Nigeria safely administered MgSO4 and/methyldopa without any adverse events.•High level of acceptance among women who were recommended methyldopa (89·2%) for severe hypertension.•The rate of acceptance for MgSO4 was similarly high (88·3%).•CHWs, if properly trained, can safely and appropriately administer MgSO4 and methyldopa to women with pre-eclampsia.
BACKGROUNDRegular blood pressure (BP) measurement is crucial for the diagnosis and management of hypertensive disorders in pregnancy, such as pre-eclampsia. BP can be measured in various settings, such as conventional clinics or self-measurement at home, and with different techniques, such as using auscultatory or automated BP devices. It is important to understand the impact of different settings and techniques of BP measurement on important outcomes for pregnant women.OBJECTIVESTo assess the effects of setting and technique of BP measurement for diagnosing hypertensive disorders in pregnancy on subsequent maternal and perinatal outcomes, women's quality of life, or use of health service resources.SEARCH METHODSWe searched Cochrane Pregnancy and Childbirth's Trials Register, ClinicalTrials.gov, the WHO International Clinical Trials Registry Platform (ICTRP) on 22 April 2020, and reference lists of retrieved studies.SELECTION CRITERIARandomised controlled trials (RCTs) involving pregnant women, using validated BP devices in different settings or using different techniques.DATA COLLECTION AND ANALYSISTwo authors independently extracted data, assessed risk of bias, and used the GRADE approach to assess the certainty of the evidence.MAIN RESULTSOf the 21 identified studies, we included three, and excluded 11; seven were ongoing. Of the three included RCTs (536,607 women), one was a cluster-RCT, with a substantially higher number of participants (536,233 deliveries) than the other two trials, but did not provide data for most of our outcomes. We generally judged the included studies at low risk of bias, however, the certainty of the evidence was low, due to indirectness and imprecision. Meta-analysis was not possible because each study investigated a different comparison. None of the included studies reported our primary outcome of systolic BP greater than or equal to 150 mmHg. None of the studies reported any of these important secondary outcomes: antenatal hospital admissions, neonatal unit length of stay, or neonatal endotracheal intubation and use of mechanical ventilation. Setting of BP measurement: self-measurement versus conventional clinic measurement (one study, 154 women) There were no maternal deaths in either the self-monitoring group or the usual care group. The study did not report perinatal mortality. Self-monitoring may lead to slightly more diagnoses of pre-eclampsia compared with usual care (risk ratio (RR) 1.49, 95% confidence interval (CI) 0.87 to 2.54; 154 women; 1 study; low-certainty evidence) but the wide 95% CI is consistent with possible benefit and possible harm. Self-monitoring may have little to no effect on the likelihood of induction of labour compared with usual care (RR 1.09, 95% CI 0.82 to 1.45; 154 women; 1 study; low-certainty evidence). We are uncertain if self-monitoring BP has any effect on maternal admission to intensive care (RR 1.54, 95% CI 0.06 to 37.25; 154 women; 1 study; low-certainty evidence), stillbirth (RR 2.57, 95% CI 0.13 to 52.63; 154 women; 1 study; low-certainty evidence), neonatal death (RR 1.54, 95% CI 0.06 to 37.25; 154 women; 1 study; low-certainty evidence) or preterm birth (RR 1.15, 95% CI 0.37 to 3.55; 154 women; 1 study; low-certainty evidence), compared with usual care because the certainty of evidence is low and the 95% CI is consistent with appreciable harms and appreciable benefits. Self-monitoring may lead to slightly more neonatal unit admissions compared with usual care (RR 1.53, 95% CI 0.65 to 3.62; 154 women; 1 study; low-certainty evidence) but the wide 95% CI includes the possibility of slightly fewer admissions with self-monitoring. Technique of BP measurement: Korotkoff phase IV (K4, muffling sound) versus Korotkoff phase V (K5, disappearance of sound) to represent diastolic BP (one study, 220 women) There were no maternal deaths in either the K4 or K5 group. There may be little to no difference in the diagnosis of pre-eclampsia between using K4 or K5 for diastolic BP (RR 1.16; 95% CI 0.89 to 1.49; 1 study; 220 women; low-certainty evidence), since the wide 95% CI includes the possibility of more diagnoses with K4. We are uncertain if there is a difference in perinatal mortality between the groups because the quality of evidence is low and the 95% CI is consistent with appreciable harm and appreciable benefit (RR 1.14, 95% CI 0.16 to 7.92; 1 study, 220 women; low-certainty evidence). The trial did not report data on maternal admission to intensive care, induction of labour, stillbirth, neonatal death, preterm birth, or neonatal unit admissions. Technique of BP measurement: CRADLE intervention (CRADLE device, a semi-automated BP monitor with additional features, and an education package) versus usual care (one study, 536,233 deliveries) There may be little to no difference between the use of the CRADLE device and usual care in the number of maternal deaths (adjusted RR 0.80, 95% CI 0.30 to 2.11; 536,233 women; 1 study; low-certainty evidence), but the 95% CI is consistent with appreciable harm and appreciable benefit. The trial did not report pre-eclampsia, induction of labour, perinatal mortality, preterm birth, or neonatal unit admissions. Maternal admission to intensive care and perinatal outcomes (stillbirths and neonatal deaths) were only collected for a small proportion of the women, identified by an outcome not by baseline characteristics, thereby breaking the random allocation. Therefore, any differences between the groups could not be attributed to the intervention, and we did not extract data for these outcomes.AUTHORS' CONCLUSIONSThe benefit, if any, of self-monitoring BP in hypertensive pregnancies remains uncertain, as the evidence is limited to one feasibility study. Current practice of using K5 to measure diastolic BP is supported for women with pregnancy hypertension. The benefit, if any, of using the CRADLE device to measure BP in pregnancy remains uncertain, due to the limitations and instability of the trial study design.
Objectives: To reduce all-cause maternal and perinatal mortality and major morbidity through Lady Health Worker (LHW)-facilitated community engagement and early diagnosis, stabilization and referral of women with preeclampsia, an important contributor to adverse maternal and perinatal outcomes given delays in early detection and initial management. Study design: In the Pakistan Community-Level Interventions for Pre-eclampsia (CLIP) cluster randomized controlled trial (NCT01911494), LHWs engaged the community, recruited pregnant women from 20 union councils (clusters), undertook mobile health-guided clinical assessment for preeclampsia, and referral to facilities after stabilization. Main outcome measures: The primary outcome was a composite of maternal, fetal and newborn mortality and major morbidity. Findings: We recruited 39,446 women in intervention (N = 20,264) and control clusters (N = 19,182) with minimal loss to follow-up (3.7% vs. 4.5%, respectively). The primary outcome did not differ between intervention (26.6%) and control (21.9%) clusters (adjusted odds ratio, aOR, 1.20 [95% confidence interval 0.84-1.72]; p = 0.31). There was reduction in stillbirths (0.89 [0.81-0.99]; p = 0.03), but no impact on maternal death (1.08 [0.69, 1.71]; p = 0.74) or morbidity (1.12 [0.57, 2.16]; p = 0.77); early (0.95 [0.82-1.09]; p = 0.46) or late neonatal deaths (1.23 [0.97-1.55]; p = 0.09); or neonatal morbidity (1.22 [0.77, 1.96]; p = 0.40). Improvements in outcome rates were observed with 4-7 (p = 0.015) and >= 8 (p < 0.001) (vs. 0) CLIP contacts. Interpretation: The CLIP intervention was well accepted by the community and implemented by LHWs. Lack of effects on adverse outcomes could relate to quality care for mothers with pre-eclampsia in health facilities. Future strategies for community outreach must also be accompanied by health facility strengthening.
(Acta Obstet Gynecol Scand. 2019;98:1178–1186) Almost half of annual maternal deaths can be attributed to postpartum hemorrhage (PPH), maternal sepsis, and abortion complications. Most of these deaths are avoidable with early identification of hemodynamic compromise, but many care providers lack the adequate training to respond properly to abnormal blood pressure (BP) and heart rate (HR) measurements. The ratio of HR to systolic BP, called the shock index (SI), is believed to be an early indicator of life-threatening adverse outcomes; SI has predicted medical events more consistently than other vital signs in PPH retrospective cohorts. While experts have proposed the use of SI measurement thresholds as early warning signs, more research is needed in PPH and maternal sepsis populations. These investigators conducted their study to determine whether SI can consistently predict adverse outcomes in PPH and maternal sepsis cases, and also observe if previously determined SI thresholds are adequate.
Preeclampsia is a common cause of acute kidney injury (AKI) in low- and middle-income countries, but AKI incidence in preeclampsia, its risk factors, and renal outcomes are unknown. A prospective observational multicenter study of women admitted with preeclampsia in South Africa was conducted. Creatinine concentrations were extracted from national laboratory databases for women with maximum creatinine of ≥90 μmol/L (≥1.02 mg/dL). Renal injury and recovery were defined by Kidney Disease Improving Global Outcomes creatinine criteria. Predefined risk factors, maternal outcomes, and neonatal outcomes were compared between AKI stages. Of 1547 women admitted with preeclampsia 237 (15.3%) met AKI criteria: 6.9% (n=107) stage 1, 4.3% (n=67) stage 2, and 4.1% (n=63) stage 3. There was a higher risk of maternal death (n=7; relative risk, 4.3; 95% CI, 1.6–11.4) and stillbirth (n=80; relative risk, 2.2; 95% CI, 1.8–2.8) in women with AKI compared with those without. Perinatal mortality was also increased (89 of 240; 37.1%). Hypertension in a previous pregnancy was the strongest predictor of AKI stage 2 or 3 (odds ratio, 2.24; 95% CI, 1.21–4.17). Renal recovery rate reduced with increasing AKI stage. A third of surviving women (76 of 230 [33.0%]) had not recovered baseline renal function by discharge. Approximately half (39 of 76; 51.3%) of these women had no further creatinine testing post-discharge. In summary, AKI was common in women with preeclampsia and had high rates of associated maternal and perinatal mortality. Only two-thirds of women had confirmed renal recovery. History of a previous hypertensive pregnancy was an important risk factor.
Preeclampsia is a common cause of acute kidney injury (AKI) in low- and middle-income countries, but AKI incidence in preeclampsia, its risk factors, and renal outcomes are unknown. A prospective observational multicenter study of women admitted with preeclampsia in South Africa was conducted. Creatinine concentrations were extracted from national laboratory databases for women with maximum creatinine of ≥90 μmol/L (≥1.02 mg/dL). Renal injury and recovery were defined by Kidney Disease Improving Global Outcomes creatinine criteria. Predefined risk factors, maternal outcomes, and neonatal outcomes were compared between AKI stages. Of 1547 women admitted with preeclampsia 237 (15.3%) met AKI criteria: 6.9% (n=107) stage 1, 4.3% (n=67) stage 2, and 4.1% (n=63) stage 3. There was a higher risk of maternal death (n=7; relative risk, 4.3; 95% CI, 1.6-11.4) and stillbirth (n=80; relative risk, 2.2; 95% CI, 1.8-2.8) in women with AKI compared with those without. Perinatal mortality was also increased (89 of 240; 37.1%). Hypertension in a previous pregnancy was the strongest predictor of AKI stage 2 or 3 (odds ratio, 2.24; 95% CI, 1.21-4.17). Renal recovery rate reduced with increasing AKI stage. A third of surviving women (76 of 230 [33.0%]) had not recovered baseline renal function by discharge. Approximately half (39 of 76; 51.3%) of these women had no further creatinine testing post-discharge. In summary, AKI was common in women with preeclampsia and had high rates of associated maternal and perinatal mortality. Only two-thirds of women had confirmed renal recovery. History of a previous hypertensive pregnancy was an important risk factor.
Background In 2015, an estimated 303 000 women died in pregnancy and childbirth. Obstetric haemorrhage, sepsis, and hypertensive disorders of pregnancy account for more than 50% of maternal deaths worldwide. There are effective treatments for these pregnancy complications, but they require early detection by measurement of vital signs and timely administration to save lives. The primary aim of this trial was to determine whether implementation of the CRADLE Vital Sign Alert and an education package into community and facility maternity care in low-resource settings could reduce a composite of all-cause maternal mortality or major morbidity (eclampsia and hysterectomy). Methods We did a pragmatic, stepped-wedge, cluster-randomised controlled trial in ten clusters across Africa, India, and Haiti, introducing the device into routine maternity care. Each cluster contained at least one secondary or tertiary hospital and their main referral facilities. Clusters crossed over from existing routine care to the CRADLE intervention in one of nine steps at 2-monthly intervals, with CRADLE devices replacing existing equipment at the randomly allocated timepoint. A computer-generated randomly allocated sequence determined the order in which the clusters received the intervention. Because of the nature of the intervention, this trial was not masked. Data were gathered monthly, with 20 time periods of 1 month. The primary composite outcome was at least one of eclampsia, emergency hysterectomy, and maternal death. This study is registered with the ISRCTN registry, number ISRCTN41244132. Findings Between April 1, 2016, and Nov 30, 2017, among 536 223 deliveries, the primary outcome occurred in 4067 women, with 998 maternal deaths, 2692 eclampsia cases, and 681 hysterectomies. There was an 8% decrease in the primary outcome from 79.4 per 10 000 deliveries pre-intervention to 72.8 per 10 000 deliveries post-intervention (odds ratio [OR] 0.92, 95% CI 0.86-0.97; p=0.0056). After planned adjustments for variation in event rates between and within clusters over time, the unexpected degree of variability meant we were unable to judge the benefit or harms of the intervention (OR 1.22, 95% CI 0.73-2.06; p=0.45). Interpretation There was an absolute 8% reduction in primary outcome during the trial, with no change in resources or staffing, but this reduction could not be directly attributed to the intervention due to variability. We encountered unanticipated methodological challenges with this trial design, which can provide valuable learning for future research and inform the trial design of future international stepped-wedge trials. Copyright (C) 2019 The Author(s). Published by Elsevier Ltd.
BackgroundIn 2015, approximately 42,000 women died as a result of hypertensive disorders of pregnancy worldwide; over 99% of these deaths occurred in low- and middle-income countries. The aim of this paper is to describe the incidence and characteristics of eclampsia and related complications from hypertensive disorders of pregnancy across 10 low- and middle-income geographical regions in 8 countries, in relation to magnesium sulfate availability.Methods and findingsThis is a secondary analysis of a stepped-wedge cluster randomised controlled trial undertaken in sub-Saharan Africa, India, and Haiti. This trial implemented a novel vital sign device and training package in routine maternity care with the aim of reducing a composite outcome of maternal mortality and morbidity. Institutional-level consent was obtained, and all women presenting for maternity care were eligible for inclusion. Data on eclampsia, stroke, admission to intensive care with a hypertensive disorder of pregnancy, and maternal death from a hypertensive disorder of pregnancy were prospectively collected from routine data sources and active case finding, together with data on perinatal outcomes in women with these outcomes. In 536,233 deliveries between 1 April 2016 and 30 November 2017, there were 2,692 women with eclampsia (0.5%). In total 6.9% (n = 186; 3.47/10,000 deliveries) of women with eclampsia died, and a further 51 died from other complications of hypertensive disorders of pregnancy (0.95/10,000). After planned adjustments, the implementation of the CRADLE intervention was not associated with any significant change in the rates of eclampsia, stroke, or maternal death or intensive care admission with a hypertensive disorder of pregnancy. Nearly 1 in 5 (17.9%) women with eclampsia, stroke, or a hypertensive disorder of pregnancy causing intensive care admission or maternal death experienced a stillbirth or neonatal death. A third of eclampsia cases (33.2%; n = 894) occurred in women under 20 years of age, 60.0% in women aged 20-34 years (n = 1,616), and 6.8% (n = 182) in women aged 35 years or over. Rates of eclampsia varied approximately 7-fold between sites (range 19.6/10,000 in Zambia Centre 1 to 142.0/10,000 in Sierra Leone). Over half (55.1%) of first eclamptic fits occurred in a health-care facility, with the remainder in the community. Place of first fit varied substantially between sites (from 5.9% in the central referral facility in Sierra Leone to 85% in Uganda Centre 2). On average, magnesium sulfate was available in 74.7% of facilities (range 25% in Haiti to 100% in Sierra Leone and Zimbabwe). There was no detectable association between magnesium sulfate availability and the rate of eclampsia across sites (p = 0.12). This analysis may have been influenced by the selection of predominantly urban and peri-urban settings, and by collection of only monthly data on availability of magnesium sulfate, and is limited by the lack of demographic data in the population of women delivering in the trial areas.ConclusionsThe large variation in eclampsia and maternal and neonatal fatality from hypertensive disorders of pregnancy between countries emphasises that inequality and inequity persist in healthcare for women with hypertensive disorders of pregnancy. Alongside the growing interest in improving community detection and health education for these disorders, efforts to improve quality of care within healthcare facilities are key. Strategies to prevent eclampsia should be informed by local data.Trial registrationISRCTN: 41244132.
Shock index (SI) is a predictor of hemodynamic compromise in obstetric patients. The SI threshold for action is not well understood. We aimed to evaluate SI thresholds as predictors of outcomes in obstetric patients. We undertook a prospective cohort study at three South African hospitals of women with postpartum hemorrhage (n = 283) or maternal sepsis (n = 126) . The “first” and “worst” SI following diagnosis were recorded. SI was compared with conventional vital signs as predictors of outcomes. The performance of SI <.9, SI .9-1.69 and SI ≥1.7 to predict outcomes (maternal death; Critical Care Unit admission; major procedure; hysterectomy) and hemorrhage-specific outcomes (lowest hemoglobin <70 g/l; blood transfusion ≥4 IU) were evaluated. “First” SI was one of two best performing vital signs for every outcome in postpartum hemorrhage and sepsis. In hemorrhage, risk of all outcomes increased with increasing “first” SI; for blood transfusion ≥4 IU odds ratio was 4.24 (95% confidence interval 1.25-14.36) for SI ≥1.7 vs SI .9-1.69. In sepsis, risk of all outcomes increased with increasing “worst” SI. Sensitivity, specificity, positive and negative predictive values of “first” SI <.9 vs SI ≥.9 for maternal death were 100.0%, 55.2%, 4.6% and 100.0%, respectively, in hemorrhage and 80.0%, 50.4%, 12.3% and 96.7%, respectively, in sepsis. The shock index was a consistent predictor of outcomes compared with conventional vital signs in postpartum hemorrhage and sepsis. SI <.9 performed well as a rule-out test and SI .9-1.69 and SI ≥1.7 indicated increased risk of all outcomes in both cohorts. These thresholds may alert to the need for urgent intervention and prevent maternal deaths.
The CRADLE-3 trial is a stepped-wedge randomised controlled trial aiming to reduce maternal mortality and morbidity by implementing a novel vital sign device (CRADLE Vital Sign Alert) and training package into routine maternity care in 10 low-income sites. The MRC Guidance on complex interventions proposes that interventions and implementation strategies be shaped by early phase piloting and development work. We present the findings of a three-month mixed-methodology feasibility study for this trial, describe how this was informed by the MRC guidance and the study design was refined.
Background: Vital signs measurement can identify pregnant and postpartum women who require urgent treatment or referral. In low-resource settings, healthcare workers have limited access to accurate vital signs measuring devices suitable for their environment and training. The CRADLE Vital Signs Alert (VSA) is a novel device measuring blood pressure and pulse that is accurate in pregnancy and designed for low-resource settings. Its traffic light early warning system alerts healthcare workers to the need for escalation of care for women with hypertension, haemorrhage or sepsis. This study evaluated the usability and acceptability of the CRADLE VSA device. Methods: Evaluation was conducted in community and primary care settings in India, Mozambique and Nigeria and tertiary hospitals in South Africa. Purposeful sampling was used to convene 155 interviews and six focus groups with healthcare workers using the device (n = 205) and pregnant women and their family members (n = 41). Interviews and focus groups were conducted in the local language and audio-recorded, transcribed and translated into English for analysis. Thematic analysis was undertaken using an a priori thematic framework, as well as an inductive approach. Results: Most healthcare workers perceived the CRADLE device to be easy to use and accurate. The traffic lights early warning system was unanimously reported positively, giving healthcare workers confidence with decision-making and a sense of professionalism. However, a minority in South Africa described manual inflation as tiring, particularly when measuring vital signs in obese and hypertensive women (n = 4) and a few South African healthcare workers distrusted the device's accuracy (n = 7). Unanimously, pregnant women liked the CRADLE device. The traffic light early warning system gave women and their families a better understanding of the importance of vital signs in pregnancy and during the postpartum period. Conclusion: The CRADLE device was well accepted by healthcare workers from a range of countries and levels of facility, including those with no previous vital signs measurement experience. The device motivated women to attend primary care and encouraged them to accept treatment and referral.