Background Fatigue, impaired sleep quality and daytime sleepiness, common in neurodegenerative and immune-mediated diseases, are debilitating and have serious societal and economic implications. Currently, measurement of these symptoms largely relies on self-reported questionnaires, which are burdensome for patients and lack sensitivity, granularity and reliability. Methods Building on a preceding feasibility study and qualification advice of the European Medicines Agency, the Clinical Observational Study of the European project Identifying Digital Endpoints to Assess FAtigue, Sleep and acTivities of daily living in Neurodegenerative disorders and Immune-mediated inflammatory diseases (IDEA-FAST) investigates the relationship between digital and clinical parameters of the target concepts of fatigue, reduced sleep quality and daytime sleepiness. Results Between 2022 and 2025, 2000 people are being recruited at 24 European sites – 500 with Parkinson's disease, 500 with inflammatory bowel disease, 200 with each of the following diseases: Huntington's disease, rheumatoid arthritis, systemic lupus erythematosus, primary Sjögren's syndrome and 200 healthy volunteers. Participants are followed over a 24-week period with four visits, each including a 1-week assessment phase at home using CE-certified digital health (including active and passive) technologies. The latter collect information on physical activity, physiology, cognition as well as social interaction and behaviour as core dimensions of the target concepts. Conclusion This study will help to develop reliable, valid and efficient digital endpoints of fatigue, impaired sleep quality and daytime sleepiness for use in future clinical studies and trials.
BackgroundMobile health (mHealth) apps are useful tools for research and disease management. However, implementation of mHealth apps is lacking in many areas. While mHealth apps offer various advantages to researchers and patients, their effectiveness depends on their actual use. Barriers to using mHealth apps are often due to human factors such as usability or technology acceptance. Although prior studies have examined the acceptance of mHealth apps in patient treatment, the key factors driving or hindering the use of mHealth apps in research remain unclear. ObjectiveThis study explores user perceptions of 2 mHealth apps in the setting of an observational technology evaluation study using the unified theory of acceptance and use of technology. We aim to evaluate the technology acceptance of these specific apps and to investigate challenges in choosing suitable mHealth apps in research. The apps were intended for data collection; no effect on health was expected. MethodsPatients with chronic diseases as well as healthy participants used a symptom tracking app and a cognitive test app over the course of 4 weeks within the feasibility study of the project “Identifying Digital Endpoints to Assess Fatigue, Sleep and Activities of Daily Living in Neurodegenerative Disorders and Immune-Mediated Inflammatory Diseases.” Thereafter, 61 qualitative interviews were conducted, recorded, and transcribed. A qualitative content analysis using the unified theory of acceptance and use of technology was performed. ResultsAn important aspect of motivation for participants was feedback on their health data and performance in the cognitive tests. Effort played a significant role in app use. Patients rated the apps as easy to use and quick. Using the app multiple times per day at fixed times was perceived as disruptive. Participants preferred using their own phone. Social influence as well as facilitating conditions played a lesser role in intention to use the apps. Data security was no concern for most participants. They stressed the importance of good relations with the study team. ConclusionsIn choosing suitable apps, one size will certainly not fit all. For medical research, pretesting of all materials with the potential users is of utmost importance. If the positive effects of the app on users’ health are not immediately apparent, other factors may motivate use, for example, feedback, gamification, adjustable functions, applicability on all smartphone operating systems, and good relations to the study team.
Fatigue, sleep, or disturbances in daily activities are common symptoms among patients with neurodegenerative disorders (NDD) and immune-mediated inflammatory diseases (IMID). The current assessment of such symptoms is usually conducted using patient reported outcomes (PROs) based on standardized questionnaires that patients usually complete every few months. This assessment protocol has raised some concerns, due to its propensity to exhibit biases derived from its subjectivity nature, or the low sensibility to changes, which may lead to a failure when trying to capture variability over time. In this work, we explore the use of smartphone data, which can serve as a proxy for how patients interact with their devices, to provide an effective, reliable, and objective assessment of the symptoms mentioned above. Our study comprises data from 137 participants belonging to 6 different disease groups, plus a healthy control group. We conducted statistical analysis based on repeated measures correlation, in which we analyze the correlation between screen-time and app-usage features with scores obtained from the PROs collected from the participants using a smartphone application.
BackgroundFatigue and sleep disturbances are highly prevalent in neurodegenerative diseases (NDDs) and immune-mediated inflammatory diseases (IMIDs). Conventional patient-reported outcomes (PROs) are subjective and prone to recall bias; Digital health technologies and wearable sleep trackers offer objective, continuous monitoring of sleep and physiology at home.ObjectiveThis study evaluated the feasibility of using consumer- and research- grade sleep trackers to predict next-day physical and mental fatigue and daytime sleepiness in individuals with NDDs and IMIDs as an exploratory analysis, and examined whether machine-learning models could identify preliminary sleep features to inform future fatigue monitoring research in chronic disease populations.MethodsThe IDEA-FAST feasibility study enrolled 134 participants (42 healthy adults, 39 NDD, 53 IMID) across four European centres. Over 3,062 nights, participants wore three sleep trackers (BedSensor, ZKONE, DREEM 2) and completed daily fatigue and sleepiness PROs at home. A polysomnography sub-study (n=28) validated tracker performance. Machine learning models using physiological and sleep-architecture features were evaluated with leave-one-subject-out cross-validation.ResultsSleep trackers showed moderate PSG agreement. Models demonstrated preliminary discriminative capacity for next-day physical fatigue in healthy adults (AUC = 0.75), driven mainly by respiratory rate and REM sleep duration. In NDD, physical fatigue AUC reached 0.62 under enriched training, with REM latency and deep sleep as key features. Mental fatigue prediction reached AUC = 0.66 in healthy adults; daytime sleepiness AUC = 0.66 in NDD. Findings should be interpreted as exploratory, as outcome binarisation using a global threshold may conflate between-person disease-group differences with within-person symptom variation.ConclusionsWearable sleep trackers show feasibility for objective home-based sleep monitoring, with preliminary evidence supporting sleep physiology as a candidate predictor of next-day physical fatigue in healthy adults. Predictive performance in chronic disease cohorts remains limited, underscoring the need for larger, multimodal studies to establish disease-specific digital fatigue endpoints.
This analysis evaluates the feasibility and psychometric properties of daily digital cognitive assessments (DCAs) delivered on smartphones using data from the large, international Identifying Digital Endpoints to Assess FAtigue, Sleep and acTivities of daily living in Neurodegenerative disorders and Immune-mediated inflammatory diseases (IDEA-FAST) study. The data we analyse were collected from patients with neurodegenerative diseases (NDDs) and immune-mediated inflammatory diseases (IMIDs), and healthy controls (a subset who participated in all phases of the study, total N=977) in their own homes. These data were obtained alongside data from other devices that monitored physiology, kinematics, and sleep quality. Following a baseline visit, participants were remotely monitored via three scheduled daily sessions for 6-7 days in each of 4 active assessment phases (APs). APs were separated by 6-week intervals. Daily schedules comprised a morning psychomotor vigilance task (PVT) with eDiary, afternoon session (eDiary only), and an evening digit symbol substitution task (DSST) with eDiary. We evaluated session coverage using logistic mixed effects, test-retest reliability using ICCs, disease impacts on performance using linear mixed effect ANCOVA, and familiarisation using linear mixed effects. Overall coverage was 67.5% for the PVT and 77.0% for the DSST, with no significant differences between the healthy volunteers and disease cohorts. Coverage varied significantly by time-of-day (Evening > Morning > Afternoon), and improved with age, with an interaction revealing session time-of-day affected older participants less, all p < .001. Coverage was highest in AP 1 and reduced in subsequent APs. AP-day effects on coverage interacted significantly with AP, with a modest decline over AP 1, and the pattern reversed in APs 2-4. Baseline reliability was good (> .70) for both PVT mean reaction time and DSST total correct across all cohorts, and the movement-based measure from the DSST ranged [.55, .75], with lower values in the Parkinson’s Disease and Primary Sjögren’s Syndrome cohorts. Both tasks showed significant cohort effects, with performance in IMID cohorts intermediate between healthy controls and NDD. Longitudinal analysis revealed significant familiarisation effects in DSST. This was greatest in healthy controls, with significant attenuation of these effects in disease cohorts. No effect of familiarisation was seen in the PVT. Collectively, these results support the usefulness of at-home cognitive assessment on smartphones. Brief measures of cognition can be captured remotely in disease as well as controls with good adherence and sensitivity to distinguish known patient groups from healthy controls. ### Competing Interest Statement The authors have declared no competing interest. ### Clinical Protocols ### Funding Statement The authors disclosed receipt of the following financial support for the research, authorship and/or publication of this article: This work was supported by the Innovative Medicines Initiative (Grant No. 853981). ### Author Declarations I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained. Yes The details of the IRB/oversight body that provided approval or exemption for the research described are given below: This study received ethical approval from the Ethics Committee at the sponsor's site (Medical Faculty of Kiel University) on 26 April 2022 (D 616/21). I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals. Yes I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance). Yes I have followed all appropriate research reporting guidelines, such as any relevant EQUATOR Network research reporting checklist(s) and other pertinent material, if applicable. Yes All data produced in the present study are available upon reasonable request to the authors
Fatigue is prevalent in immune-mediated inflammatory and neurodegenerative diseases, yet its assessment relies largely on patient-reported outcomes, which capture perception but not fluctuations over time. Wearable sensors, like inertial measurement units (IMUs), offer a way to monitor daily activities and evaluate functional capacity. This study investigates the relationship between sit-to-stand and stand-to-sit transitions and self-reported physical and mental fatigue in participants with Parkinson’s, Huntington’s, rheumatoid arthritis, systemic lupus erythematosus, primary Sjögren’s syndrome and inflammatory bowel disease. Over 4 weeks, participants wore an IMU and reported fatigue levels four times daily. Using mixed-effects models, associations were identified between fatigue and specific kinematic features, such as 5th and 95th percentiles of sit-to-stand performance, suggesting that fatigue alters the control and effort of movement. These kinematic features show promise as indicators for fatigue in these patient populations.
We propose the addition of usability validation to the extended V3 framework, now “V3+”, and describe a pragmatic approach to ensuring that sensor-based digital health technologies can be used optimally at scale by diverse users. Alongside the original V3 components (verification; analytical validation; clinical validation), usability validation will ensure user-centricity of digital measurement tools, paving the way for more inclusive, reliable, and trustworthy digital measures within clinical research and clinical care.
Background Fatigue is a prevalent and debilitating symptom in many chronic conditions, including immune-mediated inflammatory diseases (IMIDs) and neurodegenerative diseases (NDDs). Fatigue often fluctuates significantly within and between days, yet traditional patient-reported outcomes (PROs) typically rely on recall periods of a week or more, potentially missing these short-term variations. The development of digital tools, such as electronic diaries (eDiaries), offers a unique opportunity to collect granular, real-time data. However, the feasibility, adherence, and comparability of eDiary-based assessments to established PROs require further investigation. Objective This study aimed to evaluate the feasibility and acceptability of using a high-frequency eDiary to capture intraday variability in fatigue and to compare eDiary data with scores obtained from the Functional Assessment of Chronic Illness Therapy-Fatigue (FACIT-F), a validated weekly recall PRO. Methods Data were collected from 159 participants enrolled in the IDEA-FAST (Identifying Digital Endpoints to Assess Fatigue, Sleep and Activities in Daily Living in Neurodegenerative Disorders and Immune-Mediated Inflammatory Diseases) feasibility study; a 4-week prospective observational study conducted at 4 European centers. Participants included individuals with NDDs (n=39), IMIDs (n=78), and healthy volunteers (n=42). Participants used an eDiary to report their physical and mental fatigue levels up to 4 times daily on a 7-point Likert scale (0=low and 6=high). Adherence was calculated as the proportion of completed eDiary entries relative to the total expected entries. Correlations between averaged eDiary scores and weekly FACIT-F scores were analyzed. Results Adherence to the eDiary protocol was 5505/8880 (61.99%) overall, varying by cohort, with the highest adherence (1117/1200, 93.07%) observed in the primary Sjögren syndrome cohort and the lowest adherence in the Parkinson disease (410/960, 42.7%) and Huntington disease (320/720, 44.4%) cohorts. The average adherence was 430/1680 (43.45%) in the NDD cohorts and 3367/4560 (73.84%) in the IMID cohorts. Fatigue levels showed clear diurnal variation, with significantly higher fatigue reported in the evening compared to the morning (P<.001). A moderate correlation (Spearman=0.46, P<.001) was observed between eDiary fatigue scores and FACIT-F scores, with stronger cohort-specific associations for certain FACIT-F items. These results indicate that eDiaries provide complementary insights to weekly PROs by capturing intraday fluctuations in fatigue. Conclusions This study demonstrates the feasibility, acceptability, and validity of using high-frequency eDiaries to assess fatigue in chronic conditions. By effectively detecting intra- and interday fatigue variations, eDiaries complement traditional PROs such as FACIT-F, offering a more nuanced understanding of fatigue patterns. Future research should explore optimized eDiary protocols to balance participant burden with data granularity.
Hot flashes are a common side effect of androgen deprivation therapy in metastatic castration-sensitive prostate cancer (mCSPC). As part of the LIBERTAS trial evaluating an androgen-deprivation (ADT)-sparing maintenance regimen in mCSPC patients, novel exploratory endpoints of sleep quality and physical activity levels are being developed as objective and quantifiable proxies for hot flash burden. Actigraphy devices were given to study participants to capture data on sleep and physical activity. A workflow designed to increase participant wear of actigraphy devices was implemented three months into the study. After workflow deployment, the daily mean, variability, and long-term trend of adherence to wearing actigraphy device improved significantly and substantially. LIBERTAS participants wore an actigraphy device nearly 22 hours a day on average for over 12 months after workflow deployment, compared to less than 19 hours daily prior. In sensitivity analyses with wear thresholds of 18 and 22 hours, 86
Mobile health apps are useful tools for research and disease management. However, implementation of mHealth apps is lacking in many areas. While mHealth apps offer various advantages to researchers and patients, their effectiveness depends on its actual use by the intended population. Barriers to the adoption of mHealth apps often stem from human factors such as usability or technology acceptance. This study explores user perceptions of two mHealth apps in the setting of an observational technology evaluation study with the goal to investigate technology acceptance as a barrier to the implementation of mHealth apps in research. Patients with chronic diseases as well as healthy participants used a symptom and activity e-diary (SAD) and a Cognitive Test App (CTA) over the course of four weeks within the IDEA-FAST Feasibility study. Thereafter, 61 qualitative interviews were conducted, recorded and transcribed. A qualitative content analysis using the Unified Theory of Acceptance and Use of Technology (UTAUT) was performed. As the apps did not directly impact the participants’ health, motivation and adherence to schedule were issues with actual use. Some users perceived the SAD as a burden, while others enjoyed tracking their symptoms. The three tests of the CTA differed in popularity. While one test was described as repetitive, another was perceived as too hard and frustrated users. An important aspect of motivation for participants was feedback on their data and performance. While using the apps was quick, the fixed periods of use were more problematic, as they could lead to conflicts with a user’s daily life. Participants preferred using their own phone. The support provided by written instructions and the study team was sufficient for most participants. Participants stressed the importance of good relations with the study team. In choosing suitable applications, one size will certainly not fit all. For medical research, pre-testing of all materials with the potential users is of utmost importance. When an app seemingly does not provide direct impact on the users’ health, other factors can motivate usage, e.g. feedback, gamification, adjustable functions, applicability on all smartphone operating systems and good relations to the study team.
Wearables with photoplethysmography (PPG) sensors are being increasingly used in clinical research as a non-invasive, inexpensive method for remote monitoring of physiological health. Ensuring the accuracy and reliability of PPG-derived measurements is critical, as inaccuracies can impact research findings and clinical decisions. This paper systematically compares heart rate (HR) and heart rate variability (HRV) measures from PPG against an electrocardiogram (ECG) monitor in free-living settings. Two devices with PPG and one device with an ECG sensor were worn by 25 healthy volunteers for 10 days. PPG-derived HR and HRV showed reasonable accuracy and reliability, particularly during sleep, with mean absolute error < 1 beat for HR and 6–15 ms for HRV. The relative error of HRV estimated from PPG varied with activity type and was higher than during the resting state by 14–51%. The accuracy of HR/HRV was impacted by the proportion of usable data, body posture, and epoch length. The multi-scale peak and trough detection algorithm demonstrated superior performance in detecting beats from PPG signals, with an F1 score of 89% during sleep. The study demonstrates the trade-offs of utilizing PPG measurements for remote monitoring in daily life and identifies optimal use conditions by recommending enhancements.
Background Many individuals with neurodegenerative (NDD) and immune-mediated inflammatory disorders (IMID) experience debilitating fatigue. Currently, assessments of fatigue rely on patient reported outcomes (PROs), which are subjective and prone to recall biases. Wearable devices, however, provide objective and reliable estimates of gait, an essential component of health, and may present objective evidence of fatigue. This study explored the relationships between gait characteristics derived from an inertial measurement unit (IMU) and patient-reported fatigue in the IDEA-FAST feasibility study. Methods Participants with IMIDs and NDDs (Parkinson's disease (PD), Huntington's disease (HD), rheumatoid arthritis (RA), systemic lupus erythematosus (SLE), primary Sjogren’s syndrome (PSS), and inflammatory bowel disease (IBD)) wore a lower-back IMU continuously for up to 10 days at home. Concurrently, participants completed PROs (physical fatigue (PF) and mental fatigue (MF)) up to four times a day. Macro (volume, variability, pattern, and acceleration vector magnitude) and micro (pace, rhythm, variability, asymmetry, and postural control) gait characteristics were extracted from the accelerometer data. The associations of these measures with the PROs were evaluated using a generalised linear mixed-effects model (GLMM) and binary classification with machine learning. Results Data were recorded from 72 participants: PD = 13, HD = 9, RA = 12, SLE = 9, PSS = 14, IBD = 15. For the GLMM, the variability of the non-walking bouts length (in seconds) with PF returned the highest conditional R2, 0.165, and with MF the highest marginal R2, 0.0018. For the machine learning classifiers, the highest accuracy of the current analysis was returned by the micro gait characteristics with an intrasubject cross validation method and MF as 56.90% (precision = 43.9%, recall = 51.4%). Overall, the acceleration vector magnitude, bout length variation, postural control, and gait rhythm were the most interesting characteristics for future analysis. Conclusions Counterintuitively, the outcomes indicate that there is a weak relationship between typical gait measures and abnormal fatigue. However, factors such as the COVID-19 pandemic may have impacted gait behaviours. Therefore, further investigations with a larger cohort are required to fully understand the relationship between gait and abnormal fatigue.
Fatigue is a complex, multi-faceted phenomenon that is particularly common in immune-mediated inflammatory disease and neurodegenerative disease cohorts. Clinical assessment of fatigue relies heavily on patient-reported outcomes (PROs), that provide only the perception aspect of fatigue and poorly capture fluctuations over time. The use of wearable sensors, e.g., inertial measurement units, overcome these drawbacks, by allowing for the assessment of capacity and performance aspects of health through continuous monitoring of daily life activities. However, the relation between daily life activities that are prerequisite for functional independence, such as sit-to-stand and stand-to-sit transitions, and fatigue, is not well established, thus this study aims to quantify the association between kinematic features of sit-to-stand and stand-to-sit transitions and self-reported physical and mental fatigue. Study participants wore an IMU on the lower back for four consecutive weeks, and continued their daily life activities as usual, thereby reporting their physical and mental fatigue four times per day on a 7-point Likert scale via a smartphone application. Sit-to-stand and stand-to-sit transitions were detected using a validated algorithm, and kinematic features were derived from those transitions. The association between the kinematic features and PROs were researched using mixed effects models, with fatigue modelled as the independent variable and the median, 95th and 5th percentiles of the kinematic features from a 2-hour aggregation window centred around the time of administration of a PRO. The results suggested 5th and 95th percentiles of selected kinematic features were associated with fatigue across different disease cohorts. Furthermore, it was hypothesised that with more fatigue standing up is performed with more effort that is needed, whereas with more physical fatigue sitting down is performed with less control of the body movement, i.e., people drop down on their chair or sofa. In conclusion, this study showed the potential of selected kinematic features of sit-to-stand and stand-to-sit movements as intermediate clinical endpoints to reflect aspects of fatigue.
AbstractBackgroundIncreasing adoption of sensor-based digital health technologies (sDHTs) in recent years has cast light on the many challenges in implementing these tools into clinical trials and patient care at scale across diverse patient populations; however, the methodological approaches taken towards sDHT usability evaluation have varied markedly.ObjectiveTo elucidate the current landscape of studies reporting data related to sDHT human factors, human-centered design, and/or usability.MethodsWe conducted a systematic scoping review of studies published between 2013 and 2023 and indexed in PubMed, in which data related to sDHT human factors, human-centered design, and/or usability were reported. Following a systematic screening process, we extracted the study design; participant sample; the sDHT(s) used; the method(s) of data capture; and the type(s) of usability-related data captured.ResultsOur literature search returned 442 papers, of which 85 were found to be eligible and 83 were available for data extraction and not under embargo. In total, 164 sDHTs were evaluated; 141 were wearable tools while the remaining 23 were ambient tools. The majority of studies (n=55; 66%) reported summative evaluations of final-design sDHTs. Almost all studies (n=82; 98%) captured data from targeted end-users, but only 18 (22%) captured data from additional users such as carepartners or clinicians. User satisfaction and ease of use were evaluated for >80% of sDHTs; however, learnability, eficiency, and memorability were reported for only 11 (13%), 4 (5%), and 2 sDHTs (2%), respectively. Fourteen sDHTs (17%) were evaluated according to the extent to which users were able to understand the clinical data or other information presented to them (understandability) and/or the actions or tasks they should complete in response (actionability). Notable gaps in reporting included the absence of a sample size rationale (reported for 25% of all studies and 31% of summative studies) and incomplete sociodemographic descriptive data (complete age, sex/gender, and race/ethnicity reported for 17% of studies).ConclusionsBased on our findings, we suggest four actionable recommendations for future studies that will help to advance the implementation of sDHTs: 1) Consider in-depth assessment of technology usability beyond user satisfaction and ease of use; 2) Expand recruitment to include important user groups such as clinicians and carepartners; 3) Report the rationale for key study design considerations including the sample size; and 4) Provide rich descriptive statistics regarding the study sample to allow a complete understanding of generalizability to other patient populations and contexts of use.
Remote inflammation monitoring with digital health technologies (DHTs) would provide valuable information for both clinical research and care. Controlled perturbations of the immune system may reveal physiological signatures which could be used to develop a digital biomarker of inflammatory state. In this study, molecular and physiological profiling was performed following an in vivo lipopolysaccharide (LPS) challenge to develop a digital biomarker of inflammation. Ten healthy volunteers received an intravenous LPS challenge and were monitored for 24 h using the VitalConnect VitalPatch (VitalPatch). VitalPatch measurements included heart rate (HR), heart rate variability (HRV), respiratory rate (RR), and skin temperature (TEMP). Conventional episodic inpatient vital signs and serum proteins were measured pre- and post-LPS challenge. The VitalPatch provided vital signs that were comparable to conventional methods for assessing HR, RR, and TEMP. A pronounced increase was observed in HR, RR, and TEMP as well as a decrease in HRV 1-4 h post-LPS challenge. The ordering of participants by magnitude of inflammatory cytokine response 2 h post-LPS challenge was consistent with ordering of participants by change from baseline in vital signs when measured by VitalPatch (r = 0.73) but not when measured by conventional methods (r = -0.04). A machine learning model trained on VitalPatch data predicted change from baseline in inflammatory protein response (R-2 = 0.67). DHTs, such as VitalPatch, can improve upon existing episodic measurements of vital signs by enabling continuous sensing and have the potential for future use as tools to remotely monitor inflammation.
Background Increasing adoption of sensor-based digital health technologies (sDHTs) in recent years has cast light on the many challenges in implementing these tools into clinical trials and patient care at scale across diverse patient populations; however, the methodological approaches taken toward sDHT usability evaluation have varied markedly. Objective This review aims to explore the current landscape of studies reporting data related to sDHT human factors, human-centered design, and usability, to inform our concurrent work on developing an evaluation framework for sDHT usability. Methods We conducted a scoping review of studies published between 2013 and 2023 and indexed in PubMed, in which data related to sDHT human factors, human-centered design, and usability were reported. Following a systematic screening process, we extracted the study design, participant sample, the sDHT or sDHTs used, the methods of data capture, and the types of usability-related data captured. Results Our literature search returned 442 papers, of which 85 papers were found to be eligible and 83 papers were available for data extraction and not under embargo. In total, 164 sDHTs were evaluated; 141 (86%) sDHTs were wearable tools while the remaining 23 (14%) sDHTs were ambient tools. The majority of studies (55/83, 66%) reported summative evaluations of final-design sDHTs. Almost all studies (82/83, 99%) captured data from targeted end users, but only 18 (22%) out of 83 studies captured data from additional users such as care partners or clinicians. User satisfaction and ease of use were evaluated for 83% (136/164) and 91% (150/164) of sDHTs, respectively; however, learnability, efficiency, and memorability were reported for only 11 (7%), 4 (2%), and 2 (1%) out of 164 sDHTs, respectively. A total of 14 (9%) out of 164 sDHTs were evaluated according to the extent to which users were able to understand the clinical data or other information presented to them (understandability) or the actions or tasks they should complete in response (actionability). Notable gaps in reporting included the absence of a sample size rationale (reported for 21/83, 25% of all studies and 17/55, 31% of summative studies) and incomplete sociodemographic descriptive data (complete age, sex/gender, and race/ethnicity reported for 14/83, 17% of studies). Conclusions Based on our findings, we suggest four actionable recommendations for future studies that will help to advance the implementation of sDHTs: (1) consider an in-depth assessment of technology usability beyond user satisfaction and ease of use, (2) expand recruitment to include important user groups such as clinicians and care partners, (3) report the rationale for key study design considerations including the sample size, and (4) provide rich descriptive statistics regarding the study sample to allow a complete understanding of generalizability to other patient populations and contexts of use.
Current assessments of fatigue and sleepiness rely on patient reported outcomes (PROs), which are subjective and prone to recall bias. The current study investigated the use of gait variability in the "real world" to identify patient fatigue and daytime sleepiness. Inertial measurement units were worn on the lower backs of 159 participants (117 with six different immune and neurodegenerative disorders and 42 healthy controls) for up to 20 days, whom completed regular PROs. To address walking bouts that were short and sparse, four feature groups were considered: sequence-independent variability (SIV), sequence-dependant variability (SDV), padded SDV (PSDV), and typical gait variability (TGV) measures. These gait variability measures were extracted from step, stride, stance, and swing time, step length, and step velocity. These different approaches were compared using correlations and four machine learning classifiers to separate low/high fatigue and sleepiness.Most balanced accuracies were above 50%, the highest was 57.04% from TGV measures. The strongest correlation was 0.262 from an SDV feature against sleepiness. Overall, TGV measures had lower correlations and classification accuracies.Identifying fatigue or sleepiness from gait variability is extremely complex and requires more investigation with a larger data set, but these measures have shown performances that could contribute to a larger feature set.Clinical relevance— Gait variability has been repeatedly used to assess fatigue in the lab. The current study, however, explores gait variability for fatigue and daytime sleepiness in real-world scenarios with multiple gait-impacted disorders.
Nikolay Chumerin合作论文数K.U.Leuven29