Background: Decreased galactocerebrosidase (GALC) enzyme activity is causative for Krabbe disease, a lysosomal storage disorder with devastating neurodegenerative consequences. Quantitative fluorimetric assays for GALC activity in isolated blood and skin cells have been described; however, no such assay has been described using dried blood spot (DBS) specimens. Methods: GALC enzyme activity was measured quantitatively using fluorescence from a novel glycosidic substrate: carboxy derived from 6-hexadecanoylamino-4-methylumbelliferone. GALC activity was demonstrated on newborn DBS specimens, known Krabbe disease patient specimens, proficiency testing and quality control samples. Results: We present data on characterization of the novel substrate and assay, including pH optimization and enzyme kinetics using a fluorimetric profile. Single and multi-day precision analyses revealed tight analytical measurements with %CV ranging from 5.2% to 14.1%. GALC enzyme activity was linear over the range of 0.31 - 12.04 mu mol/l/h with a limit of detection of 0.066 mu mol/1/h. Our results with this assay show a clear discrimination between GALC activities in samples from Krabbe disease patients versus presumed normal newborn samples. Conclusions: A fluorimetric assay for GALC enzyme activity measurement on dried blood spot specimens is feasible. Improvements to the assay including novel substrate design, increased substrate concentration and removal of sodium chloride maximize the specificity of the assay and minimize interference from beta-galactosidase.
A biomarker is an indicator or molecular signature that is observed in normal bodily biological processes or disease conditions. Biomarkers exist in various forms, such as proteins, peptides, antibodies, cells, metabolites, hormones, lipids, and enzymes. Developing sensitive methods for the detection of diseases at an earlier stage via these structures is essential in terms of better treatment options. Therefore, researchers have recently become interested in designing nanosensors by integrating nano-scale materials with optical, mechanical, electrical, and magnetic sensors. The use of nanostructures, such as nanotubes, nanofibers, quantum dots, and nanowires, contributes to the development of cheaper, faster, and smaller sensors, which increase sensitivity as well as enhance the detection limit and response time. This chapter examines the contributions of nanotechnology in detecting and determining biomarkers and the significance of this process in the diagnosis and treatment of diseases. Moreover, the methods of biomarker detection are analyzed via different studies as presented in the literature.
INTRODUCTION:Digital microfluidics (DMF) is an emerging technology with the appropriate metrics for application to newborn and high-risk screening for inherited metabolic disease and other conditions that benefit from early treatment. Areas covered: This review traces the development of electrowetting-based DMF technology toward the fulfillment of its promise to provide an inexpensive platform to conduct enzymatic assays and targeted biomarker assays at the bedside. The high-throughput DMF platform, referred to as SEEKER®, was recently authorized by the United States Food and Drug Administration to screen newborns for four lysosomal storage disorders (LSDs) and is deployed in newborn screening programs in the United States. The development of reagents and methods for LSD screening and results from screening centers are reviewed. Preliminary results from a more compact DMF device, to perform disease-specific test panels from small volumes of blood, are also reviewed. Literature for this review was sourced using principal author and subject searches in PubMed. Expert commentary: Newborn screening is a vital and highly successful public health program. DMF technology adds value to the current testing platforms that will benefit apparently healthy newborns with underlying genetic disorders and infants at-risk for conditions that present with symptoms in the newborn period.
Current laboratory methods for comprehensive thrombophilia status require large blood volumes and long turn-around times. We demonstrate the feasibility of performing thrombophilia panel testing of enzymatic functional assays on a microfluidic cartridge using low sample volume.Functional assays for Antithrombin III, Protein C, Factor VIII, and plasminogen were adapted on the digital microfluidic platform by developing novel fluorogenic substrates and establishing on-cartridge fluorescence (360/460 nm) detection. Cartridge vs. microtiter plate results were compared using samples obtained from pediatric patients. Linear regression and Bland-Altman plots were used to establish correlations. Results were not significantly different when performed on-cartridge compared to microtiter plates. Importantly, the sample volume required is significantly lower for all on-cartridge compared to microtiter plate assays (25 μL vs. 2 ml).This study demonstrates the feasibility of thrombophilia panel testing with high-fidelity using small plasma volume. The efficacy of this near-patient technology in clinical settings needs further investigation.
The liver is a major site of lipoprotein synthesis and metabolism. Liver manifestations of chronic visceral ASMD include hepatomegaly, fibrosis, elevated liver enzymes and a pro-atherogenic lipid profile. Measurements of sphingomyelin (SM) levels in liver biopsies and lyso-SM in plasma were used as pharmacodynamic biomarkers. Five adult patients with chronic visceral ASMD were enrolled in a 26-week phase 1b trial of enzyme replacement therapy (ERT) with olipudase alfa (NCT01722526) followed by an ongoing long-term extension study (NCT02004704). We compare the changes in hepatic SM levels, plasma lyso-SM, and lipoprotein profiles after 42 months of treatment. Progressive clearance of histologic SM storage was observed throughout the trial, along with similar reductions in plasma lyso-SM. Improvements in liver enzymes were observed at 6 months and remained stable at 42 months. Progressive reductions from baseline in pro-atherogenic lipid profiles (total cholesterol, LDL-C, VLDL-C, triglycerides) were observed at month 6 and 42. Conversely, there were progressive increases in anti-atherogenic markers, HDL-C and apolipoprotein A-I, with HDL-C increases up to 200% over baseline levels after 42 months of treatment. These data demonstrate that hepatic clearance of SM during olipudase alfa treatment over 42 months is associated with overall improvements in the lipid profiles of ASMD patients. The clinical relevance of these findings needs to be determined in the future, but we speculate that these improvements may reduce the risk for liver cirrhosis and cardiovascular disease.Trial registration: Clintrials.gov trial registration # NCT01722526
BACKGROUND Newborn screening for lysosomal storage diseases (LSDs) has been gaining considerable interest owing to the availability of enzyme replacement therapies. We present a digital microfluidic platform to perform rapid, multiplexed enzymatic analysis of acid α-glucosidase (GAA) and acid α-galactosidase to screen for Pompe and Fabry disorders. The results were compared with those obtained using standard fluorometric methods. METHODS We performed bench-based, fluorometric enzymatic analysis on 60 deidentified newborn dried blood spots (DBSs), plus 10 Pompe-affected and 11 Fabry-affected samples, at Duke Biochemical Genetics Laboratory using a 3-mm punch for each assay and an incubation time of 20 h. We used a digital microfluidic platform to automate fluorometric enzymatic assays at Advanced Liquid Logic Inc. using extract from a single punch for both assays, with an incubation time of 6 h. Assays were also performed with an incubation time of 1 h. RESULTS Assay results were generally comparable, although mean enzymatic activity for GAA using microfluidics was approximately 3 times higher than that obtained using bench-based methods, which could be attributed to higher substrate concentration. Clear separation was observed between the normal and affected samples at both 6- and 1-h incubation times using digital microfluidics. CONCLUSIONS A digital microfluidic platform compared favorably with a clinical reference laboratory to perform enzymatic analysis in DBSs for Pompe and Fabry disorders. This platform presents a new technology for a newborn screening laboratory to screen LSDs by fully automating all the liquid-handling operations in an inexpensive system, providing rapid results.
A new method is presented for quantifying proteomic and metabolomic profile data by liquid chromatography-mass spectrometry (LC-MS) with electrospray ionization. This biotechnology provides differential expression measurements and enables the discovery of biological markers (biomarkers). Work presented here uses human serum but is applicable to any fluid or tissue. The approach relies on linearity of signal versus molecular concentration and reproducibility of sample processing. There is no use of isotopic labeling or chemically similar standard materials. Linear standard curves are reported for a variety of compounds introduced into human serum. As a measure of analytical reproducibility for proteome and metabolome sampling, median coefficients of variation of 25.7 and 23.8%, respectively, were determined for approximately 3400 molecular ions (not counting their numerous isotopes) from 25 independently processed human serum samples, corresponding to a total of 85000 individual molecular ion measurements.