Background: Medico-legal conflicts arise when it is difficult to prove the cause of nosocomial infections. Aim: To report an outbreak of patient-to-patient transmission of hepatitis C virus (HCV) through the repeated use of a multi-dose saline flask during the rinsing of central venous catheters. Methods: Blood samples were taken from each patient for the comparative analysis of their HCV RNA strains. No samples were available for one patient who died before the investigation started. Despite the known lability of HCV RNA, the body was exhumed four months after burial and postmortem samples were collected. HCV RNA was extracted successfully from liver and spleen samples. Genotyping of all the HCV strains was performed by sequence analysis of the 5'NC untranslated region, the E1 core conserved region and the E1/E2 hypervariable region. Findings: Forensic investigators retraced the route used by two ward nurses, when saline catheter flushes were given to 14 patients with each nurse administering to seven patients. The comparative phylogenetic analysis of all case strains identified the deceased patient as the source of contamination to five patients. Conclusions: This study highlights the value of sequence analysis as a tool for solving medico-legal conflicts. The High Court of Justice found that a health worker's re-use of a contaminated needle resulted in the nosocomial transmission of HCV. (C) 2019 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.
The risk of progressive multifocal leukoencephalopathy (PML) in patients treated with natalizumab for multiple sclerosis (MS) is a serious concern. The presence of anti-JC virus antibodies is a risk factor for PML development, but 2.5 % of the patients result falsely-negative, while the prognostic relevance of testing JCV-DNA in biological fluids of treated patients is debated. Aim of this work was to evaluate the utility of testing JCV-DNA, together with anti-JCV antibodies, in biological samples of treated patients as a tool for PML risk stratification. 126 subjects from 5 MS Centers in Italy were included in the study. We performed a cross-sectional study in 63 patients testing JCV-DNA in blood, peripheral blood cells and urine. We longitudinally assessed the presence of JCV-DNA in a cohort of 33 subjects, one of which developed PML. We could test retrospectively serum samples from another PML case occurred during natalizumab therapy. Anti-JCV antibodies and urinary JCV-DNA were both tested in 73 patients. No changes in JCV-DNA status occurred during natalizumab treatment. The subject who developed PML in the longitudinal cohort had detectable JCV-DNA in urine at all time-points while serum or blood from both PML patients were always negative before the onset of disease and, in one case, after. Four subjects with JCV-DNA in urine and undetectable anti-JCV antibodies were retested for anti-JCV antibodies and three out of four resulted positive. In conclusion, testing JCV-DNA in urine is complementary to testing anti-JCV antibodies in identifying patients at risk of PML.
Quantification of p24 antigen is still very important for HIV management, especially for diagnosis of perinatal human immunodeficiency virus type 1 infection. In 1998, M. Giacomini and O. E. Varnier developed a software (Quanti-Kin© Detection System) for p24 quantification, but over the years some problems have arisen. So a new version, with a user friendly interface developed on the web, has been published. Quanti-Kin© Web has introduced some benefits: algorithms for calculation are improved, the maximum error (Delta %) has been reduced from 1364,37 to 103,38, results of experiments can be collected worldwide and patients’ privacy is respected.
This is the first case of documented treatment failure of JCV nephritis, despite a reduction of immunosuppressive agents and the use of antiviral therapy. We consistently detected high levels of JCV viremia, which correlated with the progressive deterioration of the graft and caused the final loss of the kidney, suggesting that JCV plays an etiological role in the onset of severe nephropathy in kidney transplant patients.
Awarding the Nobel prize in physiology or medicine to Francoise Barre-Sinoussi and Luc Montagnier for the discovery of HIV-1, the causative agent of AIDS ([1][1]), is timely given the harm that the virus continues to inflict on the people of the world. While these awardees fully deserve the award
Cunninghamella bertholletiae infection occurs most frequently in neutropenic patients affected by haematological malignancies, is associated with an unfavourable outcome. We report a case of rhino-mastoidal fungal infection in a leukaemic patient. Bioptical tissue cultures yield the isolation of a mould with typical properties of Cunninghamella species. Liposomal amphotericin B (L-Amb) therapy combined with surgical intervention brought the lesion to recovery. Nevertheless, the patient died 14 days after bone marrow transplantation (BMT) from bacterial sepsis. Mastoiditis was documented at CT-scan. The conditioning regimen probably caused the reactivation of the Cunninghamella infection that led to the patient's fatal outcome; fungal hyphae were detected after autopsy of brain and lung tissue.
Follow-up of chronically infected HCV patients is the primary clinical goal in therapy administration. In the absence of an HCV vaccine, the timely monitoring of HCV viral load combined with the information of the viral genotype could contribute to patient disease management. A LightCycler Real Time RT-PCR assay was developed and optimized allowing rapid and accurate quantification of HCV RNA over an extended dynamic range using a single human reference standard. A total of 5,096 plasma samples, collected over almost 5 years, were tested and HCV RNA was quantified in 2,435 samples with levels ranging from 5.7x10(1) to 2.52x10(9) IU/ml. The precision and reproducibility of the test are documented by various inter-assay parameters of the reference standard obtained in 409 RT-PCR runs. This Real Time RT-PCR protocol uses the LightCycler cDNA amplicons for direct sequence analysis and reduces the sequencing time to approximately 3 hours. Nearly all HCV genotypes were identified. Viral sequences showed a similarity level close to 100%, independently from the viral load, while the LightCycler melting temperature analysis did not correlate with HCV genotypes. All this makes the LightCycler Real Time RT-PCR protocol a suitable tool for the diagnosis and monitoring of HCV infections.
We describe a case of primary cutaneous Absidia corymbifera infection in an AIDS patient with renal complications. The Sensititre YeastOne panel was adopted to determine antifungal susceptibility and liposomial amphotericin B was used which initially produced a significant clinical response.
ABSTRACT Human immunodeficiency virus (HIV) RNA testing is the gold standard for monitoring antiretroviral therapy in HIV-infected patients. However, equipment and reagent costs preclude widespread use of the assay in resource-limited settings. The Perkin-Elmer Ultrasensitive p24 assay and the Cavidi Exavir Load assay both offer potentially simpler, less costly technologies for monitoring viral load. These assays were compared to the Roche Amplicor HIV-1 Monitor Test, v1.5, using panels of clinical samples (subtype B) from HIV-positive subjects and HIV-spiked samples (subtypes A, C, D, CRF_01AE, CRF_02AG, and F). The Ultrasensitive p24 assay detected 100% of the spiked samples with virus loads of >250,000copies/ml and 61% of the clinical samples with virus loads of 219 to 288,850 copies/ml. Detection rates were improved substantially if an external lysis buffer was added to the procedure. The Cavidi assay detected 54 to 100% of spiked samples with virus loads >10,000 copies/ml and 68% of the clinical samples. These detection rates were also greatly improved with a newly implemented version of this kit. Coefficients of variation demonstrate good reproducibility for each of these kits. The results from the Cavidi v1.0, Cavidi v2.0, and Perkin-Elmer, and the Perkin-Elmer Plus external buffers all correlated well with the results from the Roche Monitor Test ( r = 0.83 to 0.96, r = 0.84 to 0.99, r = 0.58 to 0.67, and r = 0.59 to 0.95, respectively). Thus, the use of these two assays for monitoring patients, together with less-frequent confirmation testing, offers a feasible alternative to frequent HIV RNA testing in resource-limited settings.
ABSTRACT An inexpensive enzyme-linked immunosorbent assay method for human immunodeficiency virus type 1 quantitation, ultrasensitive p24 antigen assay (Up24), was compared with RNA viral load assay (VL). Up24 had 100% sensitivity of detection at a viral load of ≥30,000, with sensitivity of 46.4% at a viral load of <30,000 (232 specimens from 65 seropositive subjects). The assay was highly reproducible, with excellent correlation between duplicates and among three laboratories.
ABSTRACT Covert human immunodeficiency virus (HIV) replication was ongoing during the first 3 years of aviremia in 22 patients, as determined by detection of DNA containing two long terminal repeats (2LTR DNA). Although total HIV DNA was detected in 60 2LTR DNA-negative samples, the absence of 2LTR DNA in 90% of patients following 7 to 8 years of highly active antiretroviral therapy suggests suppression of cryptic viral replication.
Highly active antiretroviral therapy (HAART) induces a persistent reduction of the plasmatic viremia, contributing to decrease mortality and morbidity of infected people with human immunodeficiency virus (HIV). Thus, viral load (VL) is the reference method to evaluate therapy effectiveness. However, even in the presence of efficient HAART viral eradication was yet not achieved. In this study, we analyzed the presence of total HIV DNA (T-HIV DNA), non-integrated DNA with 2LTR (2LTR-HIV DNA) and HIV RNA in a group of 55 HIV-positive subjects from Rosario City, with different clinical stages, with and without HAART. All markers were evaluated by PCR assays optimized in our laboratory that included colorimetric detection in microplate. HIV RNA clinical sensitivity was compared with a reference test, bDNA, resulting in 74% and 64% respectively, with an 85% of agreement. Thus, our HIV RNA assay could be used to monitor patients under HAART and at risk of infection. The 2LTR-HIV DNA was 54% positive although it was absent in patients with high VL. This marker was considered a labile product therefore its presence was associated with recent infection. However, current evidences question its stability. Thus, its clinical significance should be reconsidered. The absence of 2LTR-HIV DNA in patients with detectable VL may relate to the heterogeneity of the sequence used for its detection. T-HIV DNA was present in 100% of the samples and could be a relevant remission marker when therapies that effectively eradicate the infection became available.
Epigallocatechin-3-gallate (EGCG), one of the components of green tea, has been suggested to have antiviral activity. To determine the effects of EGCG on HIV infection, peripheral blood lymphocytes were incubated with either LAI/IIIB or Bal HIV strains and increasing concentrations of EGCG. EGCG strongly inhibited the replication of both virus strains as determined by reverse transcriptase and p24 assays on the cell supernatants.
HIV infected patients are considered a sort of reservoir having different genetically distinct viral variants (quasispecies), that evolve from the starting virus inoculum. Frequently, during replication, HIV can generate nucleotide differences in the new viral population; such genetic changes may be uninfluential in viral "fitness" (replication capacity) or give the virus some advantages under a selective pressure, due to immune response or drug treatment. The use of potent combination therapy for the treatment of HIV infections has certainly improved the "quality of life" for patients, decreasing the viral load in the plasma (HIV RNA). In our study, we investigated whether detection of drug resistance-related mutations was possible in circulating PBMCs, which represent a sort of genetic archive of viral drug resistances, when the levels of viral RNA were reduced to below 400 or 50 copies/ml, since, generally, plasma samples with more than 1,000 copies/ml of HIV RNA are needed to generate some results. The study was successfully performed sequencing proviral HIV DNA in PBMCs from 32 samples belonging to 25 patients, using a new modified protocol, that showed a good reproduciblity and very interesting data, also in patients with low or without circulating HIV RNA levels.