Near real-time measurements of carbonaceous aerosols were performed in fine aerosols for a 10-day period during winter at a suburban site of Paris (France). These measurements were performed using an OCEC Sunset Field instrument for elemental carbon (EC) and organic carbon (OC); a Particle-Into-Liquid-Sampler coupled with a Total Organic Carbon (PILS-TOC) instrument for water-soluble OC (WSOC); and a 7-lambda aethalometer for absorption. A successful comparison was performed with filter sampling performed in parallel for EC, OC, and WSOC, providing further confidence on the results obtained by the online analyzers. A modified version of the aethalometer model was used to derive hourly concentrations of 3 organic aerosol (OA) sources: fossil fuel, wood burning, and secondary. This source apportionment was validated for primary OA (fossil fuel, wood burning) using time-resolved measurements of specific tracers (including levoglucosan, water-soluble potassium and methanol for wood burning) and showed that secondary organic aerosols (SOA) were the most abundant OA species during our study. Water-soluble properties of these different OA sources were investigated from the reconstruction of experimentally determined water-soluble/insoluble OC. About 23% of WSOC was found to be of a secondary (photochemical) origin. A large fraction of SOA was assigned as water-insoluble and could originate from semi-volatile primary OA from wood burning and/or anthropogenic emissions. These results have been obtained at a typical suburban site in France and may be then representative of a larger European area. They bring new light on the commonly accepted idea that SOA is mainly water-soluble.
Environmental context Volatile organic compounds are key compounds in atmospheric chemistry as precursors of ozone and secondary organic aerosols. To determine their impact at a megacity scale, a first important step is to characterise their sources. We present an estimate of volatile organic compound sources in Paris based on a combination of measurements and model results. The data suggest that the current emission inventory strongly overestimates the volatile organic compounds emitted from solvent industries, and thus needs to be corrected. Abstract A positive matrix factorisation model has been used for the determination of volatile organic compound (VOC) source contributions in Paris during an intensive campaign (May–June 2007). The major sources were traffic-related emissions (vehicle exhaust, 22% of the total mixing ratio of the measured VOCs, and fuel evaporation, 17%), with the remaining emissions from remote industrial sources (35%), natural gas and background (13%), local sources (7%), biogenic and fuel evaporation (5%) and wood-burning (2%). It was noted that the remote industrial contribution was highly dependent on the air-mass origin. During the period of oceanic influences (when only local and regional pollution was observed), this source made a relatively low contribution (<15%), whereas the source contribution linked to traffic was high (54%). During the period of continental influences (when additional continental pollution was observed), remote industrial sources played a dominant role, contributing up to 50% of measured VOCs. Finally, the positive matrix factorisation results obtained during the oceanic air mass-influenced period were compared with the local emission inventory. This comparison suggests that the VOC emission from solvent industries might be overestimated in the inventory, consistent with findings in other European cities.
Environmental context Megacities are huge hotspots of pollutants that have an impact on atmospheric composition on local to larger scales. This study presents for the first time detailed results of measurements of volatile organic compounds in Paris and shows that, whereas non-methane hydrocarbons are mainly of local and regional origin associated with traffic emissions, a significant part of oxygenated volatile organic compounds originates from continental import. This highlights the importance of measuring volatile organic compounds instead of non-methane hydrocarbons alone in source classification studies. Abstract High-time-resolution measurements of volatile organic compounds (VOCs) were performed in the Paris city centre in spring 2007. The studied region was influenced mainly by air masses of two origins: (1) from the Atlantic Ocean, and (2) from north-eastern Europe. Although the baseline levels (i.e. those not influenced by local emissions) of non-methane hydrocarbons (NMHC) and CO were only slightly impacted by changes in the air-mass origin, oxygenated compounds such as acetone and methanol showed much higher baseline levels in continentally influenced air masses. This suggests that NMHC and CO mixing ratios were mainly influenced by local-to-regional-scale sources whereas oxygenated compounds had a more significant continental-scale contribution. This highlights the importance of measuring VOCs instead of NMHC alone in source classification studies. The period of Atlantic air influence was used to characterise local pollution, which was dominated by traffic-related emissions, although traffic represents the source of only one third of total VOCs emissions in the local inventory. In addition to traffic-related sources, additional sources were identified; in particular, emissions from dry-cleaning activities were identified by the use of a specific tracer (i.e. tetrachloroethylene).
Volatile Organic Compounds and PM 2.5 aerosols fast measurements were performed during an intensive campaign in Paris (May-June 2007) within the framework of the French ANR-AEROCV project. Volatile organic compounds were measured in-situ every 30 minutes with GF-FID and every 5 minutes with a PTR-MS. The Positive Matrix Factorization (PMF) model was applied to the VOC dataset in order to determine the number of influencing sources and source profiles were identified by using known literature profiles and by the help of measured tracers (carbon monoxide, aerosols. . . ).
Near real time measurements of carbonaceous aerosols were performed in the fine mode (aerodynamic diameter, A.D. < 2.5μm) during the winter 2009 at a suburban site of Paris (France). Elemental carbon (EC) and organic carbon (OC) were determined semi-continuously every hour using a Sunset Field instrument; absorption measurements were performed every 5 min using a seven wavelength aethalometer; and water soluble organic carbon (WSOC) was determined every 4 min using a particle-into-liquid-sampler (PILS) connected with a total organic carbon (TOC) analyzer. Filter sampling was performed in parallel and showed very good agreements for EC, OC, and WSOC with on-line analyzers.