BACKGROUND:Arthroscopic rotator cuff repair (aRCR) has shown similar midterm functional results and retear rates as open/mini-open rotator cuff repair (oRCR). A pooled analysis of long-term results of both techniques is yet missing.PURPOSE:To evaluate the long-term results of aRCR and oRCR for full-thickness rotator cuff tears.STUDY DESIGN:Systematic review; Level of evidence, 4.METHODS:The systematic review followed the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines. The CENTRAL (Cochrane), MEDLINE (PubMed), and Embase databases were searched for studies that reported on long-term clinical and radiographic outcomes of full-thickness aRCR and oRCR with a minimum follow-up of 9 years.RESULTS:Eleven studies were included: 5 studies on aRCR and 6 studies on oRCR. Studies were based on 550 shoulders (539 patients) with a mean patient age of 56.3 years (range, 25-77). After a mean follow-up of 14.0 years (range, 9-20), the mean preoperative absolute Constant score (CS) and American Shoulder and Elbow Surgeons (ASES) shoulder score were significantly improved postoperatively (CS, 44 to 78 points; ASES, 52% to 91%; both comparisons, P < .001). The retear rate was 41% (141 of 342 shoulders) without a significant difference between groups (aRCR, 43%; oRCR, 39%) (P = .364). A retear was associated with significantly reduced CS as compared with a healed repair (P = .004). No significant differences were found in postoperative functional scores, complications, and retear rates after failed cuff repairs between the arthroscopic and open/mini-open repair groups.CONCLUSION:Pooled analysis of arthroscopic and open rotator cuff repairs demonstrated sustained improvement in long-term shoulder scores and pain with a substantial retear rate in both groups, which was associated with inferior shoulder function. There were no significant differences in long-term functional outcomes, retear rates, and complications. Both surgical techniques may be used on the basis of factors such as patient or surgeon preference and cost. Further studies using a more robust randomized controlled trial or larger cohort design are recommended to ascertain whether one surgical repair technique is superior to the other.REGISTRATION:CRD42020180448 (PROSPERO).
BACKGROUND:Extracortical single-button (SB) inlay repair is a commonly used distal biceps tendon technique. However, complications (eg, neurovascular injury) and nonanatomic repairs have led to the development of intracortical fixation techniques.PURPOSE:To compare the biomechanical stability of extracortical SB repair with an anatomic intracortical double-button (DB) repair technique.STUDY DESIGN:Controlled laboratory study.METHODS:The distal biceps tendon was transected in 18 cadaveric elbows from 9 donors. One elbow of each donor was randomly assigned to the extracortical SB or anatomic DB group. Both groups were cyclically loaded with 60 N over 1000 cycles between 90° of flexion and full extension. The elbow was then fixed in 90° of flexion and the repair construct loaded to failure. Gap formation and construct stiffness during cyclic loading and ultimate load to failure were analyzed.RESULTS:When compared with the extracortical SB technique after 1000 cycles, the anatomic DB technique showed significantly less gap formation (mean ± SD, 2.7 ± 0.8 vs 1.5 ± 0.9 mm; P = .017) and significantly more construct stiffness (87.4 ± 32.7 vs 119.9 ± 31.6 N/mm; P = .023). Ultimate load to failure was not significantly different between the groups (277 ± 93 vs 285 ± 135 N; P = .859). The failure mode in the anatomic DB group was significantly different from that of the extracortical SB technique (P = .002) and was due to fracture avulsion of the cortical button in 7 of 9 specimens (vs none in the SB group).CONCLUSION:Our study shows that the intracortical DB technique produces equivalent or superior biomechanical performance to that of the SB technique. The DB technique may offer a clinically viable alternative to the SB repair technique.CLINICAL RELEVANCE:This study suggests, at worst, an equivalent and, at best, a superior biomechanical performance of intracortical anatomic DB footprint repair at the time of surgery. However, the mode of failure suggests that this technique should not be used in patients with poor bone quality.
Hypothesis: Simple transverse or short oblique olecranon fractures without articular comminution are classified as Mayo type HA fractures and are typically treated with a tension band wire construct. Because of the high reoperation rates, frequently because of prominent hardware, all-suture tension band constructs have been introduced. It was the purpose to compare the biomechanical performance of conventional tension band wire fixation with a new all-suture tension band tape fixation for simple olecranon fractures. Methods: Mayo type HA olecranon fractures were created in 20 cadaveric elbows from 10 donors. One elbow of each donor was randomly assigned to the tension band wire technique (group TBW) or tension band tape (Arthrex, 1.3-mm SutureTape) technique (group TBT). Both groups were cyclically loaded with 500 N over 500 cycles, after which a uniaxial displacement was performed to evaluate load to failure. Data were analyzed for gap formation after cyclic loading, construct stiffness, and ultimate load to failure, where failure was defined as fracture gap formation greater than 4.0 mm. Results: There was no significant difference in gap formation after 500 cycles between the TBW (1.8 mm +/- 1.3 mm) and the TBT (1.9 mm +/- 1.1 mm) groups (P = .854). The TBT showed a tendency toward greater construct stiffness compared with the TBW construct (mean difference: 142 Mum; P = .053). Ultimate load to failure was not significantly different comparing both groups (TBW: 1138 N +/- 1286 N vs. TBT: 1126 N +/- 272 N; P = .928). In both groups, all repairs failed because of >4.0-mm gap formation at the fracture site and none because of tension band construct breakage. Conclusions: Our study shows that the TBT technique produces equivalent or superior biomechanical performance to the TBW for simple olecranon fractures. The TBT approach reduces the risk of hardware prominence and as a result mitigates against the need for hardware removal. The TBT technique offers a clinically viable alternative to TBW. (C) 2022 Journal of Shoulder and Elbow Surgery Board of Trustees. All rights reserved.
Background: Acromial and scapular spine fractures after reverse total shoulder arthroplasty (RTSA) can be devastating complications leading to substantial functional impairments. The purpose of this study was to review factors associated with increased acromial and scapular spine strain after RTSA from a biomechanical standpoint. Methods: A systematic review of the literature was conducted based on PRISMA guidelines. PubMed, Embase, OVID Medline, and CENTRAL databases were searched and strict inclusion and exclusion criteria were applied. Each article was assessed using the modified Downs and Black checklist to appraise the quality of included studies. Study selection, extraction of data, and assessment of methodological quality were carried out independently by two of the authors. Only biomechanical studies were considered. Results: Six biomechanical studies evaluated factors associated with increased acromial and scapular spine strain and stress. Significant increases in acromial and scapular spine strain were found with increasing lateralization of the glenosphere in four of the included studies. In two studies, glenosphere inferiorization consistently reduced acromial strain. The results concerning humeral lateralization were variable between four studies. Humeral component neck-shaft angle had no significant effect on acromial strain as analysed in one study. One study showed that scapular spine strain was significantly increased with a more posteriorly oriented acromion (55° vs. 43°; p < 0.001). Another study showed that the transection of the coracoacromial ligament increased scapular spine strain in all abduction angles (p < 0.05). Conclusions: Glenoid lateralization was consistently associated with increased acromial and scapular spine strain, whereas inferiorization of the glenosphere reduced strain in the biomechanical studies analysed in this systematic review. Humeral-sided lateralization may increase or decrease acromial or scapular spine strain. Independent of different design parameters, the transection of the coracoacromial ligament resulted in significantly increased strains and scapular spine strains were also increased when the acromion was more posteriorly oriented. The results found in this systematic review of biomechanical in-silico and in-vitro studies may help in the surgical planning of RTSA to mitigate complications associated with acromion and scapular spine fracture.
Neer Type-IIB lateral clavicle fractures are inherently unstable fractures with associated disruption of the coracoclavicular (CC) ligaments. A novel plating technique using a superior lateral locking plate with antero-posterior (AP) locking screws, resulting in orthogonal fixation in the lateral fragment has been designed to enhance stability. The purpose of this study was to biomechanically compare three different clavicle plating constructs.24 fresh-frozen cadaveric shoulders were randomised into three groups (n=8 specimens). Group 1: lateral locking plate only (Medartis Aptus Superior Lateral Plate); Group 2: lateral locking plate with CC stabilisation (Nr. 2 FiberWire); and Group 3: lateral locking plate with two AP locking screws stabilising the lateral fragment. Data was analysed for gap formation after cyclic loading, construct stiffness and ultimate load to failure, defined by a marked decrease in the load displacement curve.After 500 cycles, there was no statistically significant difference between the three groups in gap-formation (p = 0.179). Ultimate load to failure was significantly higher in Group 3 compared to Group 1 (286N vs. 167N; p = 0.022), but not to Group 2 (286N vs. 246N; p = 0.604). There were no statistically significant differences in stiffness (Group 1: 504N/mm; Group 2: 564N/mm; Group 3: 512N/mm; p = 0.712). Peri-implant fracture was the primary mode of failure for all three groups, with Group 3 demonstrating the lowest rate of peri-implant fractures (Group 1: 6/8; Group 2: 7/8, Group 3: 4/8; p = 0.243).The lateral locking plate with orthogonal AP locking screw fixation in the lateral fragment demonstrated the greatest ultimate failure load, followed by the lateral locking plate with CC stabilization. The use of orthogonal screw fixation in the distal fragment may negate against the need for CC stabilization in these types of fractures, thus minimizing surgical dissection around the coracoid and potential complications.
Reverse total shoulder arthroplasty (RTSA) is increasingly used for the treatment of complex proximal humerus fractures and fracture sequelae. In 2021, half a dozen models of fracture stems are commercially available, reflecting its growing utility for fracture management. Prosthesis designs, bone grafting and tuberosity fixation techniques have evolved to allow better and more reliable fixation of tuberosities and bony ingrowth. Patients with anatomical tuberosity healing not only have an increased range of active anterior elevation and external rotation, but also experience fewer complications and longer prosthesis survival. This review provides an overview of recent evidence on basic and fracture-specific RTSA design features as well as tuberosity fixation techniques that can influence tuberosity healing.
PURPOSE:Distinguishing between enchondromas and low-grade (grade 1) chondrosarcomas can be challenging. The aim of this study was to investigate the role of Thallium-201 scintigraphy and Technetium-99 m pentavalent dimercaptosuccinic acid (Tc-99 m DMSA (V)) in the diagnosis and grading of chondrosarcomas.METHODS:232 consecutive patients with pathologically proven cartilaginous tumours between the years 2000 and 2018 were evaluated. We included 197 patients (101 males and 96 females; median age 50 years; range 15-86 years) who underwent Thallium-201(n = 193) and/or Tc-99 m DMSA (V) scanning (n = 67). Increased uptake was defined as uptake greater than background. The reference standard was the histopathological assessment based on a grading system (grade 1-3). Data was analysed using multivariate modelling.RESULTS:There were 46 patients with enchondromas and 151 with chondrosarcomas. Of those, 64 (enchondroma n = 21, chondrosarcoma n = 43) underwent both Thallium-201 and Tc-99 m DMSA (V). Thallium-201 uptake had 7.92 times greater odds of grade 1 chondrosarcomas than enchondromas. Thallium-201 uptake was significantly associated with the odds of a higher grade chondrosarcoma (grade 2-3). DMSA (V) positivity was associated with 4.75 times the odds of a chondrosarcoma diagnosis over enchondroma (p = 0.024). DMSA (V) uptake revealed no association with chondrosarcoma grading.CONCLUSION:Low-grade chondrosarcomas continue to pose a diagnostic dilemma. Thallium-201 scans may identify malignancy in benign appearing tumours as well as differentiate between low-grade and high-grade chondrosarcomas in said malignancies. DMSA (V) may be useful in distinguishing between benign and malignant entities as a whole.