On 7 March 2006, a mobile, ground-based, vertical pointing, elastic lidar system made a North-South transect through the Mexico City basin. Column averaged, aerosol size distribution (ASD) measurements were made on the ground concurrently with the lidar measurements. The ASD ground measurements allowed calculation of the column averaged mass extinction efficiency (MEE) for the lidar system (1064 nm). The value of column averaged MEE was combined with spatially resolved lidar extinction coefficients to produce total aerosol mass concentration estimates with the resolution of the lidar (1.5 m vertical spatial and 1 s temporal). Airborne ASD measurements from DOE G-1 aircraft made later in the day on 7 March 2006, allowed the evaluation of the assumptions of constant ASD with height and time used for estimating the column averaged MEE.The results showed that the aerosol loading within the basin is about twice what is observed outside of the basin. The total aerosol base concentrations observed in the basin are of the order of 200 μg/m3 and the base levels outside are of the order of 100 μg/m3. The local heavy traffic events can introduce aerosol levels near the ground as high as 900 μg/m3.The article presents the methodology for estimating aerosol mass concentration from mobile, ground-based lidar measurements in combination with aerosol size distribution measurements. An uncertainty analysis of the methodology is also presented.
Response to the General Comments: We appreciate the effort from the reviewer. The scientific purpose of the study was twofold. First, it answered the question of what was the spatial distribution of aerosols in Mexico City and the southern vicinity in the morning of March 7th, 2006. Second, it demonstrated a truly unique measurement approach involving a mobile lidar and aerosol size distribution measurements, which when com-
A significant scale gap between radar and in situ measurements of rainfall using rain gauges and disdrometers indicates a pressing need for improved knowledge of rainfall variability at the spatial scales below those of today's operational radar rainfall products, that is, similar to 1-4 km. Lidar technology has the potential to fulfill this need, but there has been inconsistency in the literature pertaining to quantitative observations of rain using lidar. Several publications have stated that light scattering properties of raindrops could not be correlated with rain rates, while other papers have demonstrated the existence of such relationships. This note provides empirical evidence in support of the latter claim.The authors conducted a simple experiment using a near-horizontal-pointing elastic lidar to observe rain in Iowa City, Iowa, in the fall of 2005. The lidar signal was used to estimate rainfall quantities that were subsequently compared with independent estimates of the same quantities obtained from an optical disdrometer that was placed about 370 m from the lidar, similar to 10 m below the lidar beam. To perform the conversion from the raw lidar signal, the authors used an optical geometry-based procedure to estimate optical extinction data. A theoretical relationship between extinction coefficients and rain rates was derived based on a theoretical drop size distribution. The parameters of the relationship were found through a best-fit procedure using lidar and disdrometer data. The results show that the lidar-derived rain rates correspond to those obtained from the optical disdrometer with a root-mean-square difference of 55%.The authors conclude that although a great deal remains to be done to improve the inversion algorithm, lidar measurements of rain are possible and warrant further studies. Lidars deployed in conjunction with disdrometers can provide high spatial (<5 m) and temporal (<1 min disdrometer, similar to 1s lidar) resolution data over a relatively long distance for rainfall measurements (1-2 km in the case of the University of Iowa lidar).