GipsyX/RTGx is the Jet Propulsion Laboratory?s (JPL) next generation software package for positioning, navigation, timing, and Earth science using measurements from three geodetic techniques: Global Navigation Satellite Systems (GNSS), Satellite Laser Ranging (SLR), and Doppler Orbitography and Radiopositioning Integrated by Satellite (DORIS); with Very Long Baseline Interferometry (VLBI) under development. The software facilitates combined estimation of geodetic and geophysical parameters using a Kalman filter approach on real or simulated data in both post -processing and in real-time. The estimated parameters include station coordinates and velocities, satellite orbits and clocks, Earth orientation, ionospheric and tropospheric delays. The software is also capable of full realiza- tion of a dynamic terrestrial reference through analysis and combination of time series of ground station coordinates. Applying lessons learned from its predecessors, GIPSY -OASIS and Real Time GIPSY (RTG), GipsyX/RTGx was re -designed from the ground up to offer improved precision, accuracy, usability, and operational flexibility. We present some key aspects of its new archi- tecture, and describe some of its major applications, including Real-time orbit determination and ephemeris predictions in the U.S. Air Force Next Generation GPS Operational Control Segment (OCX), as well as in JPL?s Global Differential GPS (GDGPS) System, sup- porting User Range Error (URE) of <5 cm RMS; precision post -processing GNSS orbit determination, including JPL?s contributions to the International GNSS Service (IGS) with URE in the 2 cm RMS range; Precise point positioning (PPP) with ambiguity resolution, both statically and kinematically, for geodetic applications with 2 mm horizontal, and 6.5 mm vertical repeatability for static positioning; Operational orbit and clock determination for Low Earth Orbiting (LEO) satellites, such as NASA?s Gravity Recovery and Climate Experiment (GRACE) mission with GRACE relative clock alignment at the 20 ps level; calibration of radio occultation data from LEO satellites for weather forecasting and climate studies; Satellite Laser Ranging (SLR) to GNSS and LEO satellites, DORIS-based and multi -technique orbit determination for LEO; production of terrestrial reference frames and Earth rotation parameters in support of JPL?s contribution to the International Terrestrial Reference Frame (ITRF). (c) 2020 COSPAR. Published by Elsevier Ltd. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
There has been growing interest in recent years in the use of homogeneously reprocessed ground-based GNSS, VLBI, and DORIS measurements for climate applications. Existing datasets are reviewed and the sensitivity of tropospheric estimates to the processing details is discussed. The uncertainty in the derived IWV estimates and linear trends is around 1 kg m−2 RMS and ± 0.3 kg m−2 per decade, respectively. Standardized methods for ZTD outlier detection and IWV conversion are proposed. The homogeneity of final time series is limited however by changes in the stations equipment and environment. Various homogenization algorithms have been evaluated based on a synthetic benchmark dataset. The uncertainty of trends estimated from the homogenized times series is estimated to ±0.5 kg m−2 per decade. Reprocessed GNSS IWV data are analysed along with satellites data, reanalyses and global and regional climate model simulations. A selection of global and regional reprocessed GNSS datasets and ERA-interim reanalysis are made available through the GOP-TropDB tropospheric database and online service. A new tropo SINEX format, providing new features and simplifications, was developed and it is going to be adopted by all the IAG services.
To support precise orbit determination of the altimetry missions, the International DORIS Service (IDS) regularly estimates the DPOD (DORIS terrestrial reference frame for Precise Orbit Determination) solution which includes mean positions and velocities of all the DORIS stations. This solution is aligned to the current realization of the International Terrestrial Reference Frame (ITRF) and so, can be seen as a DORIS extension of the ITRF. In 2016, moving to the IDS Combination Center, the DPOD construction scheme changed. The new DPOD solution is produced from a DORIS cumulative position and velocity solution. We present the new methodology used to compute DPOD2014 and its validation procedure. In order to present geophysical applications and interpretations of these results, we show two examples: (1) the Gorkha earthquake (M7.8 - April 2015) generates a 3-D mis-positioning of nearly 55 mm of the EVEB DORIS station at the Everest base camp 90 km from the epicenter. (2) Applying the results the DPOD2014 realization, we show that the most recent vertical velocity of Thule, Greenland is similar to that observed between 2006 and 2010, indicating further ongoing ice mass loss in the Thule region of northwest Greenland. (C) 2018 COSPAR. Published by Elsevier Ltd. All rights reserved.
G. Moreaux,1 F.G. Lemoine,2 D.F. Argus,3 A. Santamarı́a-Gómez,4,5 P. Willis,6,7 L. Soudarin,1 M. Gravelle4 and P. Ferrage8 1Collecte Localisation Satellites, 8-10 rue Hermès, Parc Technologique du Canal, F-31520 Ramonville Saint-Agne, France. E-mail: gmoreaux@cls.fr 2NASA, Goddard Space Flight Center, Code 698, Greenbelt, MD 20771, USA 3Jet Propulsion Laboratory, California Institute of Technology, Pasadena, CA 91109, USA 4LIENSS, Université de La Rochelle-CNRS, 2 rue Olympe de Gouge, La Rochelle, France 5School of Land and Food, University of Tasmania, Hobart, Australia 6Institut National de l’Information Géographique et Forestière, Direction de la Recherche et de l’Enseignement, Marne-la-vallée, France 7Institut de Physique du Globe de Paris, UMR7154, Gravimétrie et géodésie spatiale, Université Paris Diderot, Sorbonne Paris Cité, Paris, France 8Centre National d’Etudes Spatiales, 18 avenue Edouard Belin, F-31401 Toulouse Cedex 9, France
We analyzed time series of daily DORIS and GPS station coordinate estimates derived from Precise Point Positioning (PPP). The DORIS coordinates were estimated using Jason-2 precise orbits based on GPS data only, implying that the station positions from the two techniques are expressed in the same GPS-based terrestrial reference frame. Comparisons of 3-D vectors of such co-located stations show systematic biases in position around South America when compared to local geodetic ties. We conclude that these results could be explained by a sensitivity of the Jason-2/DORIS oscillator to radiation when the satellite passes over the South Atlantic Anomaly (SAA). The effect for Jason-2 manifests mainly as an offset in station coordinates, though there is also evidence of a drift at the start of the mission thatdiminishes in time. This contrasts with the experience on Jason-1, wherein large, persistent drifts were observed for stations in this same (SAA) region. The spurious drift is much (∼90%) smaller for Jason-2, which may be attributable to the steps taken prior to launch to harden the oscillator. Analysis of DORIS Doppler residuals may indicate some small degradation after 2009 for these stations.
In the context of the 2014 realization of the International Terrestrial Reference Frame, the International DORIS (Doppler Orbitography Radiopositioning Integrated by Satellite) Service (IDS) has delivered to the IERS a set of 1140 weekly SINEX files including station coordinates and Earth orientation parameters, covering the time period from 1993.0 to 2015.0. From this set of weekly SINEX files, the IDS combination centre estimated a cumulative DORIS position and velocity solution to obtain mean horizontal and vertical motion of 160 stations at 71 DORIS sites. The main objective of this study is to validate the velocities of the DORIS sites by comparison with external models or time-series. Horizontal velocities are compared with two recent global plate models (GEODVEL 2010 and NNR-MORVEL56). Prior to the comparisons, DORIS horizontal velocities were corrected for Global Isostatic Adjustment from the ICE-6G (VM5a) model. For more than half of the sites, the DORIS horizontal velocities differ from the global plate models by less than 2-3 mm yr(-1). For five of the sites (Arequipa, Dionysos/Gavdos, Manila and Santiago) with horizontal velocity differences with respect to these models larger than 10 mm yr(-1), comparisons with GNSS estimates show the veracity of the DORIS motions. Vertical motions from the DORIS cumulative solution are compared with the vertical velocities derived from the latest GPS cumulative solution over the time span 1995.0-2014.0 from the University of La Rochelle solution at 31 co-located DORIS-GPS sites. These two sets of vertical velocities show a correlation coefficient of 0.83. Vertical differences are larger than 2 mm yr-1 at 23 percent of the sites. At Thule, the disagreement is explained by fine-tuned DORIS discontinuities in line with the mass variations of outlet glaciers. Furthermore, the time evolution of the vertical time-series from the DORIS station in Thule show similar trends to the GRACE equivalent water height.
The atmospheric parameters, zenith delays and gradients, obtained by the DORIS, GPS, VLBI, and numerical weather models, ECMWF and NCEP, are compared at five DORIS co-located sites during the 15days of the CONT14 campaign from 2014-05-06 until 2014-05-20. Further examined are two different solutions of GPS, VLBI and NCEP: for GPS, a network solution comparable to the TIGA reprocessing analysis strategy and a precise point positioning solution, for VLBI, a least squares and a Kalman filtered and smoothed solution, and for NCEP two spatial resolutions, 0.5° and 1.0°, are tested. The different positions of the antenna reference points at co-location sites affect the atmospheric parameters and have to be considered prior to the comparison. We assess and discuss these differences, tropospheric ties, by comparing ray-traced atmospheric parameters obtained at the positions of the various antenna reference points. While ray-traced ZHD and ZWD at the co-located antennas significantly differ, the ray-traced gradients show only very small differences. Weather events can introduce larger disagreement between atmospheric parameters obtained at co-location sites. The various weather model solutions in general agree very well in providing tropospheric ties. The atmospheric parameters are compared using statistical methods, such as the mean difference and standard deviations with repect to a weighted mean value. While GPS and VLBI atmospheric parameters agree very well in general, the DORIS observations are in several cases not dense enough to achieve a comparable level of agreement. The estimated zenith delays from DORIS, however, are competitive with the other space geodetic techniques. If the DORIS observation geometry is insufficient for the estimation of an atmospheric gradient, less than three satellites observed during the definition interval, the DORIS atmospheric parameters degrade and show small quasi-periodic variations that correlate with the number of observations and in particular with the number of satellites. An increase in the DORIS constellation concerning more satellites and in general more observations is very likely to significantly improve the quality of DORIS derived atmospheric parameters. For the first time we tested a 6h sampling of the DORIS gradients. Where the observations are sufficiently dense, the increased sampling results in an improvement of the agreement of the DORIS gradients with the other solutions.
While accuracy of tracking station coordinates is of key importance for Precise Orbit Determination (POD) for altimeter satellites, reliability and operationality are also of great concern. In particular, while recent ITRF realizations should be the most accurate at the time of their computation, they cannot be directly used by the POD groups for operational consideration for several reasons such as new stations appearing in the network or new discontinuities affecting station coordinates. For POD purposes, we computed a new DORIS terrestrial frame called DPOD2008 derived from ITRF2008 (as previously done by DPOD2005 with regards to ITRF2005). In a first step, we will present the method used to validate the past ITRF2008 using more recent DORIS data and to derive new station positions and velocities, when needed. In particular, discontinuities in DORIS station positions and/or velocities are discussed. To derive new DORIS station coordinates, we used recent DORIS weekly time series of coordinates, recent GPS relevant time series at co-located sites and also dedicated GPS campaigns performed by IGN when installing new DORIS beacons. DPOD2008 also contains additional metadata that are useful when processing DORIS data, for example, periods during which DORIS data should not be used or at least for which data should be downweighted. In several cases, a physical explanation can be found for such temporary antenna instability. We then demonstrate improvements seen when using different reference frames, such as the original ITRF2008 solution, for precise orbit determination of altimeter satellites TOPEX/Poseidon and Jason-2 over selected periods spanning 1993-2013.
The International DORIS Service (IDS) was created in 2003 under the umbrella of the International Association of Geodesy (IAG) to foster scientific research related to the French DORIS tracking system and to deliver scientific products, mostly related to the International Earth rotation and Reference systems Service (IERS). We first present some general background related to the DORIS system (current and planned satellites, current tracking network and expected evolution) and to the general IDS organization (from Data Centers, Analysis Centers and Combination Center). Then, we discuss some of the steps recently taken to prepare the IDS submission to ITRF2013 (combined weekly time series based on individual solutions from several Analysis Centers). In particular, recent results obtained from the Analysis Centers and the Combination Center show that improvements can still be made when updating physical models of some DORIS satellites, such as Envisat, Cryosat-2 or Jason-2. The DORIS contribution to ITRF2013 should also benefit from the larger number of ground observations collected by the last generation of DGXX receivers (first instrument being onboard Jason-2 satellite). In particular for polar motion, sub-milliarcsecond accuracy seems now to be achievable. Weekly station positioning internal consistency also seems to be improved with a larger DORIS constellation.
In preparation of the 2014 realization of the International Terrestrial Reference Frame (ITRF2014), the International DORIS Service delivered to the International Earth Rotation and Reference Systems Service a set of 1140 weekly solution files including station coordinates and Earth orientation parameters, covering the time period from 1993.0 to 2015.0. The data come from eleven DORIS satellites: TOPEX/Poseidon, SPOT2, SPOT3, SPOT4, SPOT5, Envisat, Jason-1, Jason-2, Cryosat-2, Saral and HY-2A. In their processing, the six analysis centers which contributed to the DORIS combined solution used the latest time variable gravity models and estimated DORIS ground beacon frequency variations. Furthermore, all the analysis centers but one excepted included in their processing phase center variations for ground antennas. The main objective of this study is to present the combination process and to analyze the impact of the new modeling on the performance of the new combined solution. Comparisons with the IDS contribution to ITRF2008 show that (i) the application of the DORIS ground phase center variations in the data processing shifts the combined scale upward by nearly 7–11mm and (ii) thanks to estimation of DORIS ground beacon frequency variations, the new combined solution no longer shows any scale discontinuity in early 2002 and does not present unexplained vertical discontinuities in any station position time series. However, analysis of the new series with respect to ITRF2008 exhibits a scale increase late 2011 which is not yet explained. A new DORIS Terrestrial Reference Frame was computed to evaluate the intrinsic quality of the new combined solution. That evaluation shows that the addition of data from the new missions equipped with the latest generation of DORIS receiver (Jason-2, Cryosat-2, HY-2A, Saral), results in an internal position consistency of 10mm or better after mid-2008.
In the frame of the celebration of the 150th birthday of the International Association of Geodesy (IAG), this contribution is devoted to the period 1917–1959, starting at the move of the IAG Central Bureau from Potsdam to Paris, up to the occurrence of space technology. Among important aspects, the evolution of international cooperation is presented, with crucial geopolitical aspects (mostly around World Wars I and II) as well as drastic technological innovations. A particular important issue is the creation of the International Union of Geodesy and Geophysics (IUGG) and the inclusion of IAG. The evolution of the IAG structure and organization is presented, as well as its links with other scientific entities.
For the first time a high-quality, consistent, global, long-term data set of zenith tropospheric delay (ZTD) and precipitable water (PW) is produced from Doppler orbitography radiopositioning integrated by satellite (DORIS) measurements at 81 sites. The data set was screened using a two-level procedure. First, postprocessing information is used to apply range checks and outlier checks to ZTD and formal error estimates. Second, outliers are detected by comparing DORIS ZTD with European Centre for Medium-Range Weather Forecasts reanalysis (ERA-Interim) data. These procedures reject 3% and 1% of the data, respectively. A linear drift is evidenced in the screened DORIS ZTD data compared to ERA-Interim and Global Positioning System (GPS) data, which potentially results from biases introduced by the progressive replacement of Alcatel antennas with Starec antennas. The DORIS PW is homogenized by applying a bias correction computed form comparison with ERA-Interim data each time station equipment is changed. The homogenized DORIS data are in excellent agreement with GPS data (correlation of 0.98 and standard deviation of differences of 1.5 kg m(-2)) and with ERA-Interim and satellite PW data (correlation > 0.95 and standard deviation of differences < 2.7 kg m(-2)). The agreement with radiosonde data is less good. Preliminary results of water vapor trends and variability are shown for 31 sites with more than 10 years of data. Good consistency is found between DORIS PW trends and ERA-Interimtrends, which demonstrates the high potential of the DORIS PW data set for climate monitoring and model verification. The final DORIS PW data set is freely available in the supporting information.