Discharge of contaminated ground water may serve as a primary and on-going source of contamination to surface water. A field investigation was conducted at a Superfund site in Massachusetts, USA to define the locus of contaminant flux and support source identification for arsenic contamination in a pond abutting a closed landfill. Subsurface hydrology and ground-water chemistry were evaluated in the aquifer between the landfill and the pond during the period 2005–2009 employing a network of wells to delineate the spatial and temporal variability in subsurface conditions. These observations were compared with concurrent measures of ground-water seepage and surface water chemistry within a shallow cove that had a historical visual record of hydrous ferric oxide precipitation along with elevated arsenic concentrations in shallow sediments. Barium, presumably derived from materials disposed in the landfill, served as an indicator of leachate-impacted ground water discharging into the cove. Evaluation of the spatial distributions of seepage flux and the concentrations of barium, calcium, and ammonium-nitrogen indicated that the identified plume primarily discharged into the central portion of the cove. Comparison of the spatial distribution of chemical signatures at depth within the water column demonstrated that direct discharge of leachate-impacted ground water was the source of highest arsenic concentrations observed within the cove. These observations demonstrate that restoration of the impacted surface water body will necessitate control of leachate-impacted ground water that continues to discharge into the cove.
The Indiana Harbor Canal (IHC) is a waterway extensively polluted with heavy metals and petroleum. Since there are limited disposal options for the petroleum-contaminated sediments (PCSs) of the canal, the environmental impact of IHC dewatered sediment when used as partial replacement of the aggregate used in hot mix asphalt (HMA) for road construction was investigated. In order to assess the long term migration of the target contaminants into the environment, the TCLP, SPLP, and a Constant pH leaching test were applied to a HMA mixture containing 10% of dewatered PCS, a conventional HMA, and the dewatered PCS. None of the heavy metals significantly leached from any of the tested materials in any of the conducted tests. Despite the presence of PAHs in the PCS, these were not found in any of the leachate samples. Finally, among the measured VOCs, only acetone and 2-butanone were found to leach from the asphalt mixtures and the sediment in the Constant pH experiment. It was concluded that it may be environmentally safe to replace the aggregates of the HMA used in road construction in the studied proportions with dewatered PCS based upon leaching levels as compared to TCLP regulated levels. This could be a viable, beneficial use option for the PCS, and therefore, for the canal remediation.
An odor study was performed at a biosolids application demonstration site using several different gas collection devices and analytical methods to determine changes in air concentration of several organic and inorganic compounds associated with biosolids application over various time periods. Various organic and inorganic odorants were detected at 1 5 m above the ground surface within the biosolids application zone area immediately after application They then decreased to non-detectable levels within 196 h after application, consistent with other biosolids application studies. Air samples collected from flux chambers installed within the application zone contained detectable concentrations of various organic odorants immediately after biosolids application. The concentrations of these odorants may have been influenced by the increased temperature within the flux chambers, and the change in concentration of these odorants over time was affected by the various sample analysis method. Airborne concentrations of ammonia and hydrogen sulfide rapidly decreased within 4 h after biosolids application, and they further decreased to non-detectable levels within 196 h after application. The highest measurements for both ammonia and hydrogen sulfide did not approach any health criterion or guidance levels for these compounds. The effects of the specific biosolids process and management variables on odor generation were not studied
A conceptual approach of a novel application of in-situ thermal processes that would either use a steam injection process or a steam/surfactant injection process was considered to remediate petroleum contaminated sediment residing in an abandoned canal. Laboratory tests were con-ducted in an attempt to volatilize or mobilize contaminants of concern (selected polycyclic aro-matic hydrocarbons [PAHs]) from the contaminated sediment into a phase that could be physically removed. The processes were operated above ambient temperature and pressure in an attempt to increase the removal of the contaminants of concern from the sediment. The ability of both the steam injection process and the steam/surfactant process to remove PAHs from the sediment was considered ineffective; as only two of the seventeen selected PAHs (naphthalene and C1 naph-thalene) were associated with a percentage mass reduction greater than 34% for both treatments (four trials). The steam/surfactant injection process generally resulted in higher reductions than the steam injection process, but had larger variances within the two trials using the treatment type. This preliminary evaluation suggests that steam-based injection processes for removing petroleum contamination from this canal sediment, using the surfactants selected, equipment set-up, and operating conditions studied, would be considered ineffective. (C) 2010 Wiley Periodicals, Inc.*