Aims Studies of remote monitoring (RM) in heart failure (HF) speculate that patients with atrial fibrillation (AF) derive the greatest benefit. We compared the impact of RM vs. usual care on clinical outcomes for patients with and without AF enrolled in the Remote Management of Heart Failure Using Implanted Electronic Devices (REM-HF) trial. Methods and results Rhythm status was available for 1561 patients (94.6%). Three categories were defined based on total AF duration during the first year of follow-up: (i) no AF (n = 1211, 77.6%), (ii) paroxysmal AF (>= 6 min to <= 7 days; n = 92, 5.9%), and (iii) persistent/permanent AF (>7 days; n = 258, 16.5%). Clinical activity, mortality, and hospitalisation rates were compared between treatment strategies for each group. RM resulted in a greater volume of clinical activity in patients with any AF, vs. no AF, with the highest per-patient intervention required for patients with persistent/permanent AF. During 2.8 +/- 0.8 years of follow-up, RM was not associated with a reduction in all-cause or cardiovascular mortality for patients with AF. However, in patients with persistent/permanent AF, RM conferred an increased risk of recurrent cardiovascular [hazard ratio (HR) 1.40, 95% confidence interval (CI) 1.06-1.85, P = 0.018] and HF-related (HR 2.05, 95% CI 1.14-3.69, P = 0.016) hospitalisations. Conclusion In patients with HF and a cardiac implanted electronic device, RM generated greater clinical activity for patients with AF, with no associated reduction in mortality, and conversely, greater risk of cardiovascular hospitalisation amongst patients with persistent/permanent AF. RM strategies may vary in their capability to guide HF management; modified approaches may be needed to improve outcomes for HF patients with AF.
Background: Cardiac implanted electronic devices (CIEDs) can detect short durations of previously unrecognised atrial fibrillation (AF). The prognostic significance of device-detected subclinical AF, in the context of contemporary heart failure (HF) therapy, is unclear. Methods: Amongst patients enrolled in the Remote Monitoring in HF with implanted devices (REM-HF) trial, three categories were defined based on total AF duration in the first year of follow-up: no AF, subclinical AF (>= 6 min to <= 24 h), and AF >24 h. All-cause mortality, stroke, and cardiovascular hospitalisation were assessed. Results: 1561 patients (94.6%) had rhythm data: 71 (4.6%) had subclinical AF (median of 4 episodes, total duration 3.1 h) and 279 (17.9%) had AF >24 h. During 2.8 +/- 0.8 years' follow-up, 39 (2.5%) patients had a stroke. Stroke rate was highest amongst patients with subclinical AF (2.0 per 100-person years) versus no AF or AF >24 h (0.8 and 1.0 per 100-person years, respectively). In the overall cohort, AF >24 h was not an independent predictor of stroke. However, amongst patients with no history of AF (n= 932), new-onset subclinical AF conferred a three-fold higher stroke risk (adjusted HR 3.35, 95%CI 1.15-9.77, p = 0.027). AF >24 h was associated with more frequent emergency cardiovascular hospitalisation (adjusted HR 1.46, 95%CI 1.19-1.79, p < 0.0005). Neither AF classification was associated with mortality. Conclusions: In patients with HF and a CIED, subclinical AF was infrequent but, as a new finding, was associated with an increased risk of stroke. Anticoagulation remains an important consideration in this population, particularly when the clinical profile indicates a high stroke risk. (c) 2020 Published by Elsevier B.V.
INTRODUCTION:It has been suggested that sudden cardiac death (SCD) contributes around 50% of cardiovascular and 27% of all-cause mortality in hemodialysis patients. The true burden of arrhythmias and arrhythmic deaths in this population, however, remains poorly characterised. Cardio Renal Arrhythmia Study in Hemodialysis (CRASH-ILR) is a prospective, implantable loop recorder single centre study of 30 established hemodialysis patients and one of the first to provide long-term ambulatory ECG monitoring.METHODS:30 patients (60% male) aged 68±12 years receiving hemodialysis for 45±40 months with varied etiology (diabetes 37%, hypertension 23%) and left ventricular ejection fraction (LVEF) 55±8% received a Reveal XT implantable loop recorder (Medtronic, USA) between August 2011 and October 2014. ECG data from loop recorders were transmitted at each hemodialysis session using a remote monitoring system. Primary outcome was SCD or implantation of a (tachy or bradyarrhythmia controlling) device and secondary outcome, the development of arrhythmia necessitating medical intervention.RESULTS:During 379,512 hours of continuous ECG monitoring (mean 12,648±9,024 hours/patient), there were 8 deaths-2 SCD and 6 due to generalised deterioration/sepsis. 5 (20%) patients had a primary outcome event (2 SCD, 3 pacemaker implantations for bradyarrhythmia). 10 (33%) patients reached an arrhythmic primary or secondary end point. Median event free survival for any arrhythmia was 2.6 years (95% confidence intervals 1.6-3.6 years).CONCLUSIONS:The findings confirm the high mortality rate seen in hemodialysis populations and contrary to initial expectations, bradyarrhythmias emerged as a common and potentially significant arrhythmic event.