Microphysiological systems (MPS) are designed to recapitulate aspects of tissue/organ physiology in vivo, thereby providing potential value in safety and efficacy assessments of FDA-regulated products and regulatory decision-making. While there have been significant advances in the development, use, and proposals of qualification criteria for human organ MPS, there remains a gap in the development using animal tissues. Animal MPS may be of value in many areas including the study of zoonotic diseases, assessment of the safety and efficacy of animal therapeutics, and possibly reduction of the use of animals in regulatory submissions for animal therapeutics. In addition, the development of MPS from various animal species enables comparison to animal in vivo data. This comparison, while not always critical for all contexts of use, could help gain confidence in the use and application of human MPS data for regulatory decision-making and for the potential identification of species-specific effects. The use of animal MPS is consistent with the replacement, reduction, and refinement (3Rs) principles of animal use by identifying toxic compounds before conducting in vivo studies and identifying the appropriate species for testing.
Integration of native bone into orthopedic devices is a key factor in long-term implant success. The material-tissue interface is generally accepted to consist of a hydroxyapatite layer so bioactive materials that can spontaneously generate this hydroxyapatite layer after implantation may improve patient outcomes. Per the ISO 22317:2014 standard, "Implants for surgery - In vitro evaluation for apatite-forming ability of implant materials," bioactivity performance statements can be assessed by soaking the material in simulated body fluid (SBF) and evaluating the surface for the formation of a hydroxyapatite layer; however, variations in test methods may alter hydroxyapatite formation and result in false-positive assessments. The goal of this study was to identify the effect of SBF formulation on bioactivity assessment. Bioglass® (45S5 and S53P4) and non-bioactive Ti-6Al-4V were exposed to SBF formulations varying in calcium ion and phosphate concentrations as well as supporting ion concentrations. Scanning electron microscopy and X-ray powder diffraction evaluation of the resulting hydroxyapatite layers revealed that SBF enriched with double or quadruple the calcium and phosphate ion concentrations increased hydroxyapatite crystal size and quantity compared to the standard formulation and can induce hydroxyapatite crystallization on surfaces traditionally considered non-bioactive. Altering concentrations of other ions, for example, bicarbonate, changed hydroxyapatite induction time, quantity, and morphology. For studies evaluating the apatite-forming ability of a material to support bioactivity performance statements, test method parameters must be adequately described and controlled. It is unclear if apatite formation after exposure to any of the SBF formulations is representative of an in vivo biological response. The ISO 23317 standard test method should be further developed to provide additional guidance on apatite characterization and interpretation of the results.
Biomaterials with nanoscale topography have been increasingly investigated for medical device applications to improve tissue-material interactions. This study assessed the impact of nanoengineered titanium surface domain sizes on early biological responses that can significantly affect tissue interactions. Nanostructured titanium coatings with distinct nanoscale surface roughness were deposited on quartz crystal microbalance with dissipation (QCM-D) sensors by physical vapor deposition. Physico-chemical characterization was conducted to assess nanoscale surface roughness, nano-topographical morphology, wettability, and atomic composition. The results demonstrated increased projected surface area and hydrophilicity with increasing nanoscale surface roughness. The adsorption properties of albumin and fibrinogen, two major plasma proteins that readily encounter implanted surfaces, on the nanostructured surfaces were measured using QCM-D. Significant differences in the amounts and viscoelastic properties of adsorbed proteins were observed, dependent on the surface roughness, protein type, protein concentration, and protein binding affinity. The impact of protein adsorption on subsequent biological responses was also examined using qualitative and quantitative in vitro evaluation of human platelet adhesion, aggregation, and activation. Qualitative platelet morphology assessment indicated increased platelet activation/aggregation on titanium surfaces with increased roughness. These data suggest that nanoscale differences in titanium surface roughness influence biological responses that may affect implant integration.
Ultrasmall superparamagnetic iron oxide nanoparticles (USPIONs) have been investigated for biomedical applications, including novel contrast agents, magnetic tracers for tumor imaging, targeted drug delivery vehicles, and magneto-mechanical actuators for hyperthermia and thrombolysis. Despite significant progress, recent clinical reports have raised concerns regarding USPION safety related to endothelial cell dysfunction; however, there is limited information on factors contributing to these clinical responses. The influence of USPION surface chemistry on nanoparticle interactions with proteins may impact endothelial cell function leading to adverse responses. Therefore, the goal of this study was to assess the effects of carboxyl-functionalized USPION (CU) or amine-functionalized USPION (AU) (approximately 30 nm diameter) on biological responses in human coronary artery endothelial cells. Increased protein adsorption was observed for AU compared with CU after exposure to serum proteins. Exposure to CU, but not AU, resulted in a concentration-dependent decrease in cell viability and perinuclear accumulation inside cytoplasmic vesicles. Internalization of CU was correlated with endothelial cell functional changes under non-cytotoxic conditions, as evidenced by a marked decreased expression of endothelial-specific adhesion proteins (eg, vascular endothelial-cadherin and platelet endothelial cell adhesion molecule-1) and increased endothelial permeability. Evaluation of downstream signaling indicated endothelial permeability is associated with actin cytoskeleton remodeling, possibly elicited by intracellular events involving reactive oxygen species, calcium ions, and the nanoparticle cellular uptake pathway. This study demonstrated that USPION surface chemistry significantly impacts protein adsorption and endothelial cell uptake, viability, and barrier function. This information will advance the current toxicological profile of USPION and improve development, safety assessment, and clinical outcomes of USPION-enabled medical products.
Lithium phenyl (2,4,6-trimethylbenzoyl) phosphinate (LAP) is a free radical photo-initiator used to initiate free radical chain polymerization upon light exposure, and is combined with gelatin methacryloyl (GelMA) to produce a photopolymer used in bioprinting. The free radicals produced under bioprinting conditions are potentially cytotoxic and mutagenic. Since these photo-generated free radicals are highly-reactive but short-lived, toxicity assessments should be conducted with light exposure. In this study, photorheology determined that 10 min exposure to 9.6 mW/cm2 405 nm light from an LED light source fully crosslinked 10 wt % GelMA with >3.4 mmol/L LAP, conditions that were used for subsequent cytotoxicity and mutagenicity assessments. These conditions were cytotoxic to M-1 mouse kidney collecting duct cells, a cell type susceptible to lithium toxicity. Exposure to ≤17 mmol/L (0.5 wt %) LAP without light was not cytotoxic; however, concurrent exposure to ≥3.4 mmol/L LAP and light was cytotoxic. No condition of LAP and/or light exposure evaluated was mutagenic in bacterial reverse mutation assays using S. typhimurium strains TA98, TA100 and E. coli WP2 uvrA. These data indicate that the combination of LAP and free radicals generated from photo-excited LAP is cytotoxic, but mutagenicity was not observed in bacteria under typical bioprinting conditions.
In this study, lithographic ceramic manufacturing was used to create solid chips out of hydroxyapatite, tricalcium phosphate, zirconia, alumina, and SiAlON ceramic. X-ray powder diffraction of each material confirmed that the chips were crystalline, with little amorphous character that could result from remaining polymeric binder, and were composed entirely out of the ceramic feedstock. Surface morphologies and roughnesses were characterized using atomic force microscopy. Human bone marrow stem cells cultured with osteogenic supplements on each material type expressed alkaline phosphatase levels, an early marker of osteogenic differentiation, on par with cells cultured on a glass control. However, cells cultured on the tricalcium phosphate-containing material expressed lower levels of ALP suggesting that osteoinduction was impaired on this material. Further analyses should be conducted with these materials to identify underlying issues of the combination of material and analysis method.
In this study, the structure, adhesion, and cell viability characteristics of silicon-incorporated diamond-like carbon (Si-DLC) coatings on fused silica substrates were investigated. The effects of argon and oxygen postprocessing plasma treatments on the Si-DLC coatings were also studied. The contact angle results showed that the Si-DLC coatings were more hydrophilic than the uncoated surfaces, and postprocessing plasma treatment increased the hydrophilicity of the Si-DLC coatings. Atomic force microscopy and profilometry confirmed that postprocessing plasma treatment increased the thickness and roughness of the Si-DLC coatings. The results of microscratch testing indicated that the plasma treatments reduced the adhesion of the coatings. The x-ray photoelectron spectroscopy (XPS) showed the presence of carbon, oxygen, and silicon in the Si-DLC coatings before and after the plasma treatments. These results show that the postprocessing plasma treatment significantly reduced the atomic percentage of the carbon in the Si-DLC coatings. XPS also confirmed the presence of carbon in the form of sp3(C-C), sp2(C=C), C-O, and C=O bonds in the Si-DLC coatings; it showed that postprocessing treatments significantly increased the percentage of oxygen in the Si-DLC coatings. Fourier transform infrared spectroscopy (FTIR) analysis showed features associated with C-OH stretching, C-H bending, as well as Si-CH2 and C-H bending in the Si-DLC coating. The XPS and FTIR results confirmed that the plasma treatment caused dissociation of the sp2 and sp3 bonds and formation of C-OH bonds. The contact angle data indicated that postprocessing treatment increased the hydrophilicity of the Si-DLC coating. Similar to the uncoated substrates, L929 cells showed no change in cell viability when cultured on Si-DLC coatings. These results of the study indicate the suitability of Si-DLC coatings as inert coatings for medical and biotechnology applications.
Ultrasmall superparamagnetic iron oxide nanoparticles (USPION) possess reactive surfaces, are metabolized and exhibit unique magnetic properties. These properties are desirable for designing novel theranostic biomedical products; however, toxicity mechanisms of USPION are not completely elucidated. The goal of this study was to investigate cell interactions (uptake and cytotoxicity) of USPION using human coronary artery endothelial cells as a vascular cell model. Polyvinylpirrolidone-coated USPION were characterized: average diameter 17 nm (transmission electron microscopy [TEM]), average hydrodynamic diameter 44 nm (dynamic light scattering) and zeta potential -38.75 mV. Cells were exposed to 0 (control), 25, 50, 100 or 200 μg/mL USPION. Concentration- and time-dependent cytotoxicity were observed after 3-6 hours through 24 hours of exposure using Alamar Blue and Real-Time Cell Electronic Sensing assays. Cell uptake was evaluated by imaging using live-dead confocal microscopy, actin and nuclear fluorescent staining, and TEM. Phase-contrast, confocal microscopy, and TEM imaging showed significant USPION internalization as early as 3 hours after exposure to 25 μg/mL. TEM imaging demonstrated particle internalization in secondary lysosomes with perinuclear localization. Three orthogonal assays were conducted to assess apoptosis. TUNEL staining demonstrated a marked increase in fragmented DNA, a response pathognomonic of apoptosis, after a 4-hour exposure. Cells subjected to agarose gel electrophoresis exhibited degraded DNA 3 hours after exposure. Caspase-3/7 activity increased after a 3-hour exposure. USPION uptake resulted in cytotoxicity involving apoptosis and these results contribute to further mechanistic understanding of the USPION toxicity in vitro in cardiovascular endothelial cells.
Matrix-assisted pulsed laser evaporation (MAPLE) has many benefits over conventional methods (e.g., dip-coating, spin coating, and Langmuir–Blodgett dip-coating) for manufacturing coatings containing pharmacologic agents on medical devices. In particular, the thickness of the coating that is applied to the surface of the medical device can be tightly controlled. In this study, MAPLE was used to deposit rapamycin-polyvinylpyrrolidone (rapamycin-PVP) thin films onto silicon and borosilicate optical glass substrates. Alamar Blue and PicoGreen studies were used to measure the metabolic health and DNA content of L929 mouse fibroblasts as measures of viability and proliferation, respectively. The cells on the MAPLE-deposited rapamycin-PVP surfaces exhibited 70.6% viability and 53.7% proliferation compared to a borosilicate glass control. These data indicate that the antiproliferative properties of rapamycin were maintained after MAPLE deposition.
[This corrects the article DOI: 10.1098/rsfs.2017.0063.].
Gelatin methacryloyl (GelMA) and lithium phenyl-2,4,6-trimethylbenzoylphosphinate (LAP) photoinitiator are commonly used in combination to produce a photosensitive polymer but there are concerns that must be addressed: the presence of unreacted monomer is well known to be cytotoxic, and lithium salts are known to cause acute kidney injury. In this study, acellular 10% GelMA hydrogels cross-linked with different LAP concentrations and cross-linking illumination times were evaluated for their cytotoxicity, photosensitizing potential, and elastic moduli. Alamar Blue and CyQuant Direct Cell viability assays were performed on human primary renal proximal tubule epithelial cells (hRPTECs) exposed to extracts of each formulation. UV exposure during cross-linking was not found to affect extract cytotoxicity in either assay. LAP concentration did not affect extract cytotoxicity as determined by the Alamar Blue assay but reduced hRPTEC viability in the CyQuant Direct cell assay. Photocatalytic activity of formulation extracts toward NADH oxidation was used as a screening method for photosensitizing potential; longer UV exposure durations yielded extracts with less photocatalytic activity. Finally, elastic moduli determined using nanoindentation was found to plateau to approximately 20-25 kPa after exposure to 342 mJ/cm2 at 2.87 mW of UV-A exposure regardless of LAP concentration. LAP at concentrations commonly used in bioprinting (<0.5% w/w) was not found to be cytotoxic although the differences in cytotoxicity evaluation determined from the two viability assays imply cell membrane damage and should be investigated further. Complete cross-linking of all formulations decreased photocatalytic activity while maintaining predictable final elastic moduli.
Sintered tape-cast yttria-stabilized zirconia (YSZ) was evaluated for its elemental composition, crystal structure, and imaged with atomic force microscopy (AFM) and scanning electron microscopy (SEM). Human bone marrow stem cells (hBMSC) were cultured on the ceramic and differentiated into the osteoblast lineage; alkaline phosphatase (ALP) activity was tracked as a differentiation marker. The YSZ was composed of purely tetragonal grains with a median equivalent circular diameter of 283 nm. Zirconium, yttrium, oxygen, and adventitious carbon was detected on the substrate with no other elements in significant quantities detected. YSZ samples had an RMS roughness value of 27 nm, elastic modulus of 206 ± 14 GPa, and hardness of 14 ± 2 GPa. hBMSC were observed to attach and proliferate on the YSZ surfaces and had significantly increased ALP versus the undifferentiated control cultured on glass. This method for producing a YSZ ceramic yields a typical material of this type and supports attachment and differentiation of hBMSC; thus, making it useful as a bone implant material.
Introduction: In vitro toxicology evaluations utilizing human stem cell models represent attractive alternatives to conventional animal models, which are not always predictive of human responses. Silver nanoparticles (AgNP) are a potent antimicrobial for use in orthopedic devices. However, AgNP exposure may alter the behavior of stem cells within the bone marrow. The aim of this study was to determine if differences in cell proliferation, early, and late osteogenic differentiation markers can be detected in osteogenically differentiating human bone marrow mesenchymal stem cells (hBMSC) over a 21-day period at AgNP concentrations that are not considered cytotoxic after 24-hour exposure per ISO 10993-5 cytotoxicity testing guidelines. Materials and Methods: Polyvinylpyrrolidone (PVP)-coated 10 nm AgNP were evaluated for their short-term (24-hour) cytotoxicity to hBMSC using the MTT assay to determine subcytotoxic concentrations for the subsequent long-term study investigating osteogenic differentiation. hBMSC were exposed to 1, 5, or 10 μg/mL AgNP in three different exposure scenarios: single (24-hour), repeated (24-hour at 1, 7, and 14 days), or continuous (21-day) exposure. Alkaline phosphatase (early osteogenic differentiation marker), hydroxyapatite deposition (late marker), and cell proliferation were measured at days 1, 7, 14, and 21. Results: AgNP exposure reduced cell proliferation for all treatments. Neither differentiation marker expression was observed at any timepoint in hBMSC exposed to AgNP at 10 μg/mL for any exposure scenario or in cells exposed to 5 μg/mL in the repeated or continuous exposure scenarios. Conclusions: Differences in proliferation and osteogenic marker expression were detected in the different exposure scenarios at AgNP concentrations identified as subcytotoxic in a 24-hour exposure assay.
This is an update of Goering, P.L., Barber, D.S. (2010). Hepatotoxicity of Copper, Iron, Cadmium, and Arsenic, Comprehensive Toxicology, 2nd edn, vol. 9, pp. 501–526, ISBN 978-0-08-046884-6, 10.1016/B978-0-08-046884-6.01022-8.
Cellular responses are highly influenced by biochemical and biomechanical interactions with the extracellular matrix (ECM). Due to the impact of ECM architecture on cellular responses, significant research has been dedicated towards developing biomaterials that mimic the physiological environment for design of improved medical devices and tissue engineering scaffolds. Surface topographies with microscale and nanoscale features have demonstrated an effect on numerous cellular responses, including cell adhesion, migration, proliferation, gene expression, protein production, and differentiation; however, relationships between biological responses and surface topographies are difficult to establish due to differences in cell types and biomaterial surface properties. Therefore, it is important to optimize implant surface feature characteristics to elicit desirable biological responses for specific applications. The goal of this work was to review studies investigating the effects of microstructured and nanostructured biomaterials on in vitro biological responses through fabrication of microscale and nanoscale surface topographies, physico-chemical characterization of material surface properties, investigation of protein adsorption dynamics, and evaluation of cellular responses in specific biomedical applications.
Aim: The goal of this study was to determine whether bacterial clearance in a rodent model would be impaired upon exposure to gold, silver or silica nanoparticles (NPs). Materials & methods: Mice received weekly injections of NPs followed by a challenge of Listeria monocytogenes (LM). On days 3 and 10 after LM injections, the animals were sacrificed and their tissues were collected for elemental analysis, electron microscopy and LM count determination. Results: The untreated and NP-treated animals cleared LM at the same rate suggesting that bioaccumulation of NPs did not increase the animals' susceptibility to bacterial infection. Conclusion: The data from this study indicate that the bioaccumulation of NPs does not significantly affect the ability to react to a bacterial challenge.
Silver nanoparticles (AgNP) are incorporated into medical devices for their anti-microbial characteristics. The potential exposure and toxicity of AgNPs is unknown due to varying physicochemical particle properties and lack of toxicological data. The aim of this safety assessment is to derive a provisional tolerable intake (pTI) value for AgNPs released from blood-contacting medical devices. A literature review of in vivo studies investigating critical health effects induced from intravenous (i. v.) exposure to AgNPs was evaluated by the Annapolis Accords principles and Toxicological Data Reliability Assessment Tool (ToxRTool). The point of departure (POD) was based on an i. v. 28-day repeated AgNP (20 nm) dose toxicity study reporting an increase in relative spleen weight in rats with a 5% lower confidence bound of the benchmark dose (BMDL05) of 0.14 mg/kg bw/day. The POD was extrapolated to humans by a modifying factor of 1,000 to account for intraspecies variability, interspecies differences and lack of long-term toxicity data. The pTI for long-term i. v. exposure to 20 nm AgNPs released from blood-contacting medical devices was 0.14 μg/kg bw/day. This pTI may not be appropriate for nanoparticles of other physicochemical properties or routes of administration. The methodology is appropriate for deriving pTIs for nanoparticles in general.
Silver nanoparticles (AgNPs) have generated a great deal of interest in the research, consumer product, and medical product communities due to their antimicrobial and anti-biofouling properties. However, in addition to their antimicrobial action, concerns have been expressed about the potential adverse human health effects of AgNPs. In vitro cytotoxicity studies often are used to characterize the biological response to AgNPs and the results of these studies may be used to identify hazards associated with exposure to AgNPs. Various factors, such as nanomaterial size (diameter), surface area, surface charge, redox potential, surface functionalization, and composition play a role in the development of toxicity in in vitro test systems. In addition, the interference of AgNPs with in vitro cytotoxicity assays may result in false negative or false positive results in some in vitro biological tests. The goal of this review is to: 1) summarize the impact of physical-chemical parameters, including size, shape, surface chemistry and aggregate formation on the in vitro cytotoxic effects of AgNPs; and 2) explore the nature of AgNPs interference in in vitro cytotoxicity assays.