OBJECTIVES:To assess retrospectively whether diffusion-weighted magnetic resonance imaging (DW-MRI) allows physicians to determine the severity of histopathologic findings in biopsies of renal allograft patients with deteriorating renal function.METHODS:Forty consecutive kidney transplant patients underwent DW-MRI and biopsy. Patients were assigned to one group with severe and to another group with normal or mild histopathologic findings. These two groups were compared based on a qualitative DW-MRI assessment (homo-/heterogeneity) and the combination of qualitative and quantitative DW-MRI parameters (ADC, and intravoxel incoherent motion, IVIM, parameters: D, f, D*). Sensitivity, specificity, and accuracy were determined for each parameter.RESULTS:Biopsy findings were severe in 25 patients and normal or mild in 15 patients. Qualitative DW-MRI led to a sensitivity of 44.0% and a specificity of 93.3%. Combined qualitative and quantitative DW-MRI led to an accuracy of 80% for both the minimal ADC (ADCmin) and the minimal perfusion fraction (fmin) with a sensitivity of 84.0% and 92.0% and a specificity of 73.3% and 60.0%, respectively.CONCLUSION:Combined qualitative and quantitative DW-MRI might allow physicians to determine the severity of histopathologic findings in biopsies of a high number of kidney transplant patients.KEY POINTS:• Qualitative DW-MRI is highly specific when predicting the severity of kidney transplant biopsy. • Allografts appearing heterogeneous on ADC are associated with severe histopathologic findings. • Combining qualitative and quantitative DW-MRI parameters improves the classification's sensitivity and accuracy. • Kidney transplant biopsies might be spared by combining qualitative and quantitative DW-MRI.
Prostate imaging and interpretation is based on prostate imaging reporting and data system version 2 (PI-RADS™ v2) providing clinical guidelines for multiparametric magnetic resonance imaging (mpMRI) of the prostate. PI-RADS™ v2 aims to promote global standardisation, to diminish variation in the acquisition, interpretation and reporting of prostate mpMRI examinations and to improve detection, localisation, and risk stratification in patients with suspected cancer in treatment naïve prostate glands. It does not address detection of recurrence, progression during active surveillance and evaluation of other parts of the body.PI-RADS™ v2 improves and standardises communication between radiologists and urologists to detect or exclude the presence of significant prostate cancer with a high likelihood. Findings on mpMRI are assessed on a 5-point category scale based on the probability that a combination of findings on T2-weighted (T2w) sequences, diffusion-weighted MRI (DWI) and dynamic contrast-enhanced MRI (DCE-MRI) correlates with the presence of a clinically significant prostate cancer at a particular location. PI-RADS assessment categories range from 1 to 5 with 5 being most likely to represent clinically significant prostate cancer. The dominant sequence to detect prostate cancer in the peripheral zone is DWI, whereas for tumour detection in the transition zone T2w is the most important sequence. DCE-MRI has been attributed a minor role and only qualitative assessment with presence or absence of focal enhancement is suggested. Up to four suspicious lesions of category 3, 4 and 5 are assigned on a sector map and the index lesion should be identified.
Any information contained in this pdf file is automatically generated from digital material submitted to EPOS by third parties in the form of scientific presentations. References to any names, marks, products, or services of third parties or hypertext links to thirdparty sites or information are provided solely as a convenience to you and do not in any way constitute or imply ECR's endorsement, sponsorship or recommendation of the third party, information, product or service. ECR is not responsible for the content of these pages and does not make any representations regarding the content or accuracy of material in this file. As per copyright regulations, any unauthorised use of the material or parts thereof as well as commercial reproduction or multiple distribution by any traditional or electronically based reproduction/publication method ist strictly prohibited. You agree to defend, indemnify, and hold ECR harmless from and against any and all claims, damages, costs, and expenses, including attorneys' fees, arising from or related to your use of these pages. Please note: Links to movies, ppt slideshows and any other multimedia files are not
BACKGROUND:Despite the increasingly higher spatial and contrast resolution of CT, nodular lesions are prone to be missed on chest CT. Tinted lenses increase visual acuity and contrast sensitivity by filtering short wavelength light of solar and artificial origin.PURPOSE:To test the impact of Gunnar eyewear, image quality (standard versus low dose CT) and nodule location on detectability of lung nodules in CT and to compare their individual influence.MATERIAL AND METHODS:A pre-existing database of CT images of patients with lung nodules >5 mm, scanned with standard does image quality (150 ref mAs/120 kVp) and lower dose/quality (40 ref mAs/120 kVp), was used. Five radiologists read 60 chest CTs twice: once with Gunnar glasses and once without glasses with a 1 month break between. At both read-outs the cases were shown at lower dose or standard dose level to quantify the influence of both variables (eyewear vs. image quality) on nodule sensitivity.RESULTS:The sensitivity of CT for lung nodules increased significantly using Gunnar eyewear for two readers and insignificantly for two other readers. Over all, the mean sensitivity of all radiologist raised significantly from 50% to 53%, using the glasses (P value = 0.034). In contrast, sensitivity for lung nodules was not significantly affected by lowering the image quality from 150 to 40 ref mAs. The average sensitivity was 52% at low dose level, that was even 0.7% higher than at standard dose level (P value = 0.40). The strongest impact on sensitivity had the factors readers and nodule location (lung segments).CONCLUSION:Sensitivity for lung nodules was significantly enhanced by Gunnar eyewear (+3%), while lower image quality (40 ref mAs) had no impact on nodule sensitivity. Not using the glasses had a bigger impact on sensitivity than lowering the image quality.
OBJECTIVES:The aim of this phantom study was to minimize the radiation dose by finding the best combination of low tube current and low voltage that would result in accurate volume measurements when compared to standard CT imaging without significantly decreasing the sensitivity of detecting lung nodules both with and without the assistance of CAD.METHODS:An anthropomorphic chest phantom containing artificial solid and ground glass nodules (GGNs, 5-12 mm) was examined with a 64-row multi-detector CT scanner with three tube currents of 100, 50 and 25 mAs in combination with three tube voltages of 120, 100 and 80 kVp. This resulted in eight different protocols that were then compared to standard CT sensitivity (100 mAs/120 kVp). For each protocol, at least 127 different nodules were scanned in 21-25 phantoms. The nodules were analyzed in two separate sessions by three independent, blinded radiologists and computer-aided detection (CAD) software.RESULTS:The mean sensitivity of the radiologists for identifying solid lung nodules on a standard CT was 89.7% ± 4.9%. The sensitivity was not significantly impaired when the tube and current voltage were lowered at the same time, except at the lowest exposure level of 25 mAs/80 kVp [80.6% ± 4.3% (p = 0.031)]. Compared to the standard CT, the sensitivity for detecting GGNs was significantly lower at all dose levels when the voltage was 80 kVp; this result was independent of the tube current. The CAD significantly increased the radiologists' sensitivity for detecting solid nodules at all dose levels (5-11%). No significant volume measurement errors (VMEs) were documented for the radiologists or the CAD software at any dose level.CONCLUSIONS:Our results suggest a CT protocol with 25 mAs and 100 kVp is optimal for detecting solid and ground glass nodules in lung cancer screening. The use of CAD software is highly recommended at all dose levels.
Objectives: To find the best pairing of first and second reader at highest sensitivity for detecting lung nodules with CT at various dose levels.Materials and methods: An anthropomorphic lung phantom and artificial lung nodules were used to simulate screening CT-examination at standard dose (100 mAs, 120 kVp) and 8 different low dose levels, using 120, 100 and 80 kVp combined with 100, 50 and 25 mAs. At each dose level 40 phantoms were randomly filled with 75 solid and 25 ground glass nodules (5-12 mm). Two radiologists and 3 different computer aided detection softwares (CAD) were paired to find the highest sensitivity.Results: Sensitivities at standard dose were 92%, 90%, 84%, 79% and 73% for reader 1, 2, CAD1, CAD2, CAD3, respectively. Combined sensitivity for human readers 1 and 2 improved to 97%, (p1 = 0.063, p2 = 0.016). Highest sensitivities - between 97% and 99.0% - were achieved by combining any radiologist with any CAD at any dose level. Combining any two CADs, sensitivities between 85% and 88% were significantly lower than for radiologists combined with CAD (p < 0.03).Conclusions: Combination of a human observer with any of the tested CAD systems provide optimal sensitivity for lung nodule detection even at reduced dose at 25 mAs/80 kVp. (C) 2013 Elsevier Ireland Ltd. All rights reserved.
Purpose: Unilateral or bilateral axillary masses in children are often of clinical concern for malignancies. Our review illustrates a normal variant of the axilla mimicking clinically an axillary mass. Methods and Materials: Systematic review of our PACS and RIS with the keyword “axilla” and the modality “ultrasound” in children under 16 years of age from 1.12.2009 until 30.11.2012. 19 axillary ultrasound examinations in 16 patients (7m/9f, age 3 months to 15 years) were included. One patient was examined 2 and one patient 3 times. In 6 patients a prominent muscle was noted overlying the humeral head in an abducted position. The muscle diameter was measured in cm and compared with the contralateral side. In one patient photographs of the axilla were available. Results: In 16 examinations a lymphadenopathy (n=5), abscess formation (n=5), seroma or hematoma (n=1) or lymphangioma (n=1) and no diagnosis (n=1) was found. In 4 patients (25%) a unilateral muscle variant and in 2 patients a bilateral muscle variant (axillary arch muscle) was noted. In one patient a duplication of the muscle was found. In 4 patients the muscle was larger than the contralateral side. Conclusion: An axillary mass in children without other clinical complaints may be related to a normal variant, the axillary arch muscle. Ultrasound is the first modality of choice if imaging is required. Radiologists should be aware of this normal variant since no other workup is necessary in asymptomatic children.
Poster: ECR 2013 / C-1104 / Optimal low-dose levels in screening chest computed-tomography (CT) for minimal patient radiation and unimpaired detection of lung nodules with and without computer assisted detection (CAD) by: Christe1, Z. Szucs-Farkas2, A. Huber1, P. Steiger1, J. Roos3, J. Heverhagen1, L. Ebner1; 1Bern/CH, 2Biel/ Bienne/CH, 3Winterthur/CH
Ein gesundes, korperlich sehr aktives, achtjahriges Madchen wird vom Kinderarzt zugewiesen zur sonografischen Abklarung einer asymptomatischen Schwellung beider Axillae. Zwei Wochen zuvor im Turnunterricht war dem Madchen beim Hockstrecken der Arme erstmals eine Masse in beiden Achseln aufgefallen.