This case describes the use of high-flow oxygen delivered via nasal prongs in the management of an adult patient with severe undifferentiated respiratory failure for the purposes of prolonged air medical transfer.
ABSTRACT:Traumatic peripheral nerve injuries are at high risk of neuropathic pain for which novel effective therapies are urgently needed. Preclinical models of neuropathic pain typically involve irreversible ligation and/or nerve transection (neurotmesis). However, translation of findings to the clinic has so far been unsuccessful, raising questions on injury model validity and clinically relevance. Traumatic nerve injuries seen in the clinic commonly result in axonotmesis (ie, crush), yet the neuropathic phenotype of "painful" nerve crush injuries remains poorly understood. We report the neuropathology and sensory symptoms of a focal nerve crush injury using custom-modified hemostats resulting in either complete ("full") or incomplete ("partial") axonotmesis in adult mice. Assays of thermal and mechanically evoked pain-like behavior were paralleled by transmission electron microscopy, immunohistochemistry, and anatomical tracing of the peripheral nerve. In both crush models, motor function was equally affected early after injury; by contrast, partial crush of the nerve resulted in the early return of pinprick sensitivity, followed by a transient thermal and chronic tactile hypersensitivity of the affected hind paw, which was not observed after a full crush injury. The partially crushed nerve was characterized by the sparing of small-diameter myelinated axons and intraepidermal nerve fibers, fewer dorsal root ganglia expressing the injury marker activating transcription factor 3, and lower serum levels of neurofilament light chain. By day 30, axons showed signs of reduced myelin thickness. In summary, the escape of small-diameter axons from Wallerian degeneration is likely a determinant of chronic pain pathophysiology distinct from the general response to complete nerve injury.
Standardisation of animal handling procedures for a wide range of preclinical imaging scanners will improve imaging performance and reproducibility of scientific data. Whilst there has been significant effort in defining how well scanners should operate and how in vivo experimentation should be practised, there is little detail on how to achieve optimal scanner performance with best practices in animal welfare. Here, we describe a system-agnostic, adaptable and extensible animal support cradle system for cardio-respiratory-synchronised, and other, multi-modal imaging of small animals. The animal support cradle can be adapted on a per application basis and features integrated tubing for anaesthetic and tracer delivery, an electrically driven rectal temperature maintenance system and respiratory and cardiac monitoring. Through a combination of careful material and device selection, we have described an approach that allows animals to be transferred whilst under general anaesthesia between any of the tomographic scanners we currently or have previously operated. The set-up is minimally invasive, cheap and easy to implement and for multi-modal, multi-vendor imaging of small animals.
The development of image-guided small animal irradiators represents a significant improvement over standard irradiators by enabling preclinical studies to mimic radiotherapy in humans. The ability to deliver tightly collimated targeted beams, in conjunction with gantry or animal couch rotation, has the potential to maximize tumor dose while sparing normal tissues. However, the current commercial platforms do not incorporate respiratory gating, which is required for accurate and precise targeting in organs subject to respiration related motions that may be up to the order of 5 mm in mice. Therefore, a new treatment head assembly for the Xstrahl Small Animal Radiation Research Platform (SARRP) has been designed. This includes a fast X-ray shutter subsystem, a motorized beam hardening filter assembly, an integrated transmission ionization chamber to monitor beam delivery, a kinematically positioned removable beam collimator and a targeting laser exiting the center of the beam collimator. The X-ray shutter not only minimizes timing errors but also allows beam gating during imaging and treatment, with irradiation only taking place during the breathing cycle when tissue movement is minimal. The breathing related movement is monitored by measuring, using a synchronous detector/lock-in amplifier that processes diffuse reflectance light from a modulated light source. After thresholding of the resulting signal, delays are added around the inhalation/exhalation phases, enabling the "no movement" period to be isolated and to open the X-ray shutter. Irradiation can either be performed for a predetermined time of X-ray exposure, or through integration of a current from the transmission monitor ionization chamber (corrected locally for air density variations). The ability to successfully deliver respiratory-gated X-ray irradiations has been demonstrated by comparing movies obtained using planar X-ray imaging with and without respiratory gating, in addition to comparing dose profiles observed from a collimated beam on EBT3 radiochromic film mounted on the animal's chest. Altogether, the development of respiratory-gated irradiation facilitates improved dose delivery during animal movement and constitutes an important new tool for preclinical radiation studies. This approach is particularly well suited for irradiation of orthotopic tumors or other targets within the chest and abdomen where breathing related movement is significant.
We describe a microscopy design methodology and details of microscopes built to this open' design approach. These demonstrate the first implementation of time-domain fluorescence microscopy in a flexible automated platform with the ability to ease the transition of this and other advanced microscopy techniques from development to use in routine biology applications. This approach allows easy expansion and modification of the platform capabilities, as it moves away from the use of a commercial, monolithic, microscope body to small, commercial off-the-shelf and custom made modular components. Drawings and diagrams of our microscopes have been made available under an open license for noncommercial use at http://users.ox.ac.uk/atdgroup. Several automated high-content fluorescence microscope implementations have been constructed with this design framework and optimized for specific applications with multiwell plates and tissue microarrays. In particular, three platforms incorporate time-domain FLIM via time-correlated single photon counting in an automated fashion. We also present data from experiments performed on these platforms highlighting their automated wide-field and laser scanning capabilities designed for high-content microscopy. Devices using these designs also form radiation-beam end-stations' at Oxford and Surrey Universities, showing the versatility and extendibility of this approach.