Context Few meta-analyses on incidence of endocrine immune-related adverse effects (eirAEs) have been published and many trials have been published since. Objective We performed a comprehensive meta-analysis with updated literature to assess risk and incidence of eirAEs of any grade and grade 3 to 5 by immune checkpoint inhibitor (ICI) monotherapy or combination therapy in solid tumors. Methods An electronic search using PubMed/Medline, Embase, and the Cochrane Library was performed. Randomized controlled studies (RCTs) assessing eirAEs under ICI monotherapy or ICI combination therapy were selected. Stata software (v17) was used for statistical analyses and risk of bias was evaluated using Review Manager version 5.3. Results A total of 69 RCTs with 80 independent reports, involving 42 886 patients, were included in the study. Meta-analysis revealed the following pooled estimates for risk ratio and incidence, respectively: for any grade hypothyroidism 7.81 (95% CI, 5.68-10.74, P < .0001) and 7.64% (95% CI, 6.23-9.17, P < .0001); significantly increased also for hyperthyroidism, hypophysitis/hypopituitarism, and adrenal insufficiency; and for insulin-dependent diabetes mellitus 1.52 (95% CI, 1.07-2.18, P = .02), and 0.087% (95% CI, 0.019-0.189, P = .0006), respectively. Meta-regression showed that combination of ICIs (nivolumab plus ipilimumab; durvalumab plus tremelimumab) is an independent risk factor for any grade hypophysitis/hypopituitarism, and that ICI agent is an independent factor of risk for adrenal insufficiency, but that cancer type is not an independent risk factor for eirAEs. Conclusion We showed that risk, independent from cancer type, and incidence of eirAEs are substantially increased with ICI therapy. Combination of ICIs increases risk for eirAEs, especially for hypophysitis/hypopituitarism.
BACKGROUND:To examine the applicability of the "taller than wide" (ttw) criterium for risk assessment of thyroid nodules (TNs) in primary/secondary care units and the role of thyroid scintigraphy therein. METHODS:German bicenter study performed in a setting of primary/secondary care. Patient recruitment and analysis in center A was conducted in a prospective manner. In center B, patient data were retrieved from a database that was originally generated by prospective data collection. TNs were assessed by ultrasound and thyroid scans, mostly fine needle biopsy and occasionally surgery and others. In center A, only patients who presented for the first time were included. The inclusion criterion was any TN ≥ 10 mm that had at least the following two sonographic risk features: solidity and a ttw shape. In center B, consecutive patients who had at least ttw and hypofunctioning nodules ≥ 10 mm were retrieved from the above-mentioned database. The risk of malignancy was determined according to a mixed reference standard and compared with literature data. RESULTS:In center A, 223 patients with 259 TNs were included into the study. For further analysis, 200 nodules with a reference standard were available. The overall malignancy rate was 2.5% (upper limit of the 95% CI: 5.1%). After the exclusion of scintigraphically hyperfunctioning nodules, the malignancy rate increased slightly to 2.8% (upper limit of the 95% CI: 5.7%). Malignant nodules exhibited sonographic risk features additional to solidity and ttw shape more often than benign ones. In addition to the exclusion of hyperfunctioning nodules, when considering only nodules without additional US risk features, i.e., exclusively solid and ttw-nodules, the malignancy rate decreased to 0.9% (upper limit 95% CI: 3.7%). In center B, from 58 patients, 58 ttw and hypofunctioning TNs on thyroid scans with a reference standard were available. Malignant nodules from center B were always solid and hypoechoic. The overall malignancy rate of hypofunctioning and ttw nodules was 21%, with the lower limit of the 95% CI (one-sided) being 12%. CONCLUSIONS:In primary/secondary care units, the lowest TIRADS categories for indicating FNB, e.g., applying one out of five sonographic risk features, may not be appropriate owing to the much lower a priori malignancy risk in TNs compared to tertiary/quaternary care units. Even the combination of two sonographic risk features, "solidity" and "ttw", may only be appropriate in a limited fashion. In contrast, the preselection of TNs according to hypofunctioning findings on thyroid scans clearly warranted FNB, even when applying only one sonographic risk criterion ("ttw"). For this reason, thyroid scans in TNs may not only be indicated to rule out hyperfunctioning nodules from FNB but also to rule in hypofunctioning ones.
Abstract Purpose To evaluate the recommendations for or against fine needle biopsy (FNB) of hypofunctioning thyroid nodules (TNs) using of five different Ultrasound (US) -based risk stratification systems (RSSs). Methods German multicenter study with 563 TNs (≥ 10 mm) in 534 patients who underwent thyroid US and surgery. All TNs were evaluated with ACR TI-RADS, EU-TIRADS, ATA, K-TIRADS 2016 and modified K-TIRADS 2021. A correct recommendation was defined as: malignant TN with recommendation for FNB (appropriate) or benign TN without recommendation for FNB (avoided). An incorrect recommendation was defined as: malignant TN without recommendation for FNB (missed) or benign TN with recommendation for FNB (unnecessary). Results ACR TI-RADS demonstrated the highest rate of correct (42.3 %) and lowest rate of incorrect recommendations (57.7 %). The other RRSs showed similar results for correct (26.5 %–35.7 %) and incorrect (64.3 %–73.5 %) recommendations. ACR TI-RADS demonstrated the lowest rate of unnecessary (73.4 %) and the highest rate of appropriate (26.6 %) FNB recommendation. For other RSSs, the rates of unnecessary and appropriate FNB were between 75.2 %–77.1 % and 22.9 %–24.8 %. The lowest rate of missed FNB (14.7 %) and the highest rate of avoided FNB (85.3 %) was found for ACR TI-RADS. For the other RSSs, the rates of missed and avoided FNB were between 17.8 %–26.9 % and 73.1 %–82.2 %. When the size cutoff was disregarded, an increase of correct recommendations and a decrease of incorrect recommendations was observed for all RSSs. Conclusion The RSSs vary in their ability to correctly recommend for or against FNB. An understanding of the impact of nodule size cutoffs seems necessary for the future of TIRADS.
Thyroglobulin (Tg) is an iodinated glycoprotein, which is normally stored in the follicular colloid of the thyroid, being a substrate for thyroid hormone production. Since it is produced by well-differentiated thyroid cells, it is considered a reliable tumor marker for patients with differentiated thyroid carcinoma (DTC) during their follow-up after total thyroidectomy and radioiodine ablation. It is used to monitor residual disease and to detect recurrent disease. After total thyroid ablation, unstimulated highly sensitive Tg measurements are sufficiently accurate to avoid exogenous or endogenous thyrotropin (TSH) stimulation and provide accurate diagnostic and prognostic information in the great majority of DTC patients. Adopting sophisticated statistical analysis, i.e., decision tree models, the use of Tg before radioiodine theranostic administration was demonstrated to be useful in refining conventional, pathology-based risk stratification and providing personalized adjuvant or therapeutic radioiodine administrations. The follow-up of DTC patients aims to promptly identify patients with residual or recurrent disease following primary treatment. Our review paper covers the diagnostic, theranostic and prognostic value of thyroglobulin in DTC patients.
Purpose: To evaluate the impact of video sequences (cine-loops) on the interobserver agreement (IOA) using risk stratification systems (RSSs) for thyroid nodules (TNs). Methods: Twenty TNs were randomly selected from a large database and evaluated by twelve experienced observers using five different RSSs (Kwak-, ACR-, EU-, Korean-TIRADS, ATA Guidelines). In the first step, the evaluation was conducted based on static ultrasound (US) images in two planes (“static”). Six months later, these cases were reevaluated by the same observers using video sequences in two planes (“cine-loops”). Fleiss’ kappa (κ) was calculated for the IOA analyses. Results: IOA on static was moderate with κ values of 0.46, 0.42, 0.40, 0.45, and 0.38 for the Kwak-, ACR-, EU-, Korean-TIRADS, and ATA Guidelines, respectively, while the IOA on cine-loops was fair with κ values of 0.41, 0.38, 0.37, 0.36, and 0.34 for the Kwak-, ACR-, EU-, Korean-TIRADS, and ATA Guidelines, respectively. The overall IOA was superior in static images versus cine-loops (p = 0.024). Among other findings, the subgroup analyses (related to age, gender, US certificates, number of thyroid US per week, and RSSs experience) particularly showed that the experience of the observers in using RSSs had a significant influence on the IOA. Conclusions: The overall IOA (all twelve observers and all five RSSs) was superior on static US images in comparison to cine-loops. Furthermore, the overall IOA of the five US features revealed superior κ values of the static images over cine-loops. However, this impact was significantly lower when the observers were highly experienced in the use of US RSSs of TNs.
Objective: The management of thyroid nodules with indeterminate cytology (ITN) is still a challenge. To evaluate the performance of commercial molecular tests for ITN, we performed this comprehensive meta-analysis. Methods: We performed an electronic search using PubMed/Medline, Embase, and the Cochrane Library. Studies assessing the diagnostic accuracy of Afirma gene expression classifier (GEC), Afirma gene sequencing classifier (GSC), ThyroSeq v2 (TSv2), or ThyroSeq v3 (TSv3) in patients with ITN (only Bethesda category III or IV) were selected; Statistical analyses were performed by using Stata. Results: Seventy-one samples (GEC, n = 38; GSC, n = 16; TSv2, n = 9; TSv3, n = 8) in 53 studies, involving 6490 fine needle aspirations (FNAs) with ITN cytology with molecular diagnostics (GEC, GSC, TSv2, or TSv3), were included in the study. The meta-analysis showed the following pooled estimates: sensitivity 0.95 (95% CI: 0.94–0.97), specificity 0.35 (0.28–0.43), positive likelihood ratio (LR+) 1.5 (1.3–1.6), and negative likelihood ratio (LR−) 0.13 (0.09–0.19), with the best performance for TSv3 (area under the ROC curve 0.95 (0.93–0.96), followed by TSv2 (0.90 (0.87–0.92)), GSC (0.86 (0.82–0.88)), and GEC (0.82 (0.78–0.85)); the best rule-out property was observed for GSC (LR−, 0.07 (0.02–0.19)), followed by TSv3 (0.11 (0.05–0.24)) and GEC (0.16 (0.10–0.28), and the best rule-in was observed for TSv2 (LR+, 2,9 (1.4–4.6)), followed by GSC (1.9 (1.6–2.4)). A meta-regression analysis revealed that study design, Bethesda category, and type of molecular test were independent factors. Conclusion: We showed that in patients with ITN, TSv3 has the best molecular diagnostic performance, followed by TSv2, GSC, and GEC. As regards rule-out malignancy, GSC, and rule-in, TSV2 is superior to other tests.
BACKGROUND:We provide an update on calcitonin (Ctn) screening for the early detection of medullary thyroid carcinoma (MTC) and present the results of a large single-center analysis evaluating sex-specific cut-off-levels and long-term courses.METHODS:A total of 12,984 consecutive adult patients (20.1% male and 79.9% female) with thyroid nodules who had undergone routine Ctn measurement were retrospectively analyzed. Patients with confirmed suspicious Ctn values were referred for surgery.RESULTS:Ctn measurements were elevated in 207 (1.6%) patients, with values below twice the sex-specific reference limit in 82% of these cases. Further clarification was possible in 124/207 cases, of which MTC could be ruled out in 108 cases. Histopathological assessment confirmed MTC in 16/12,984 patients.CONCLUSIONS:Our extrapolated MTC prevalence of 0.14% is significantly lower than that described in early international screening studies. The stimulation test can usually be dispensable when using a decision-making concept based on sex-specific basal Ctn cut-off values. Ctn screening is recommended even in patients with very small thyroid nodules. High quality standards in pre-analytics, laboratory measurements, and the interpretation of data must be ensured, as well as close interdisciplinary cooperation between medical disciplines.
Objective:Recurrence of differentiated thyroid cancer (DTC) is associated with reduced quality of life, and therefore, early identification of patients at risk is urgently needed.Here we investigated the predictive power of various cut-off values of single stimulated thyroglobulin (s-Tg) and single highly sensitive measured, unstimulated thyroglobulin (u-hsTg) measurements close to the end of primary therapy for recurrence-free survival (RFS) in long-term follow-up (>10 years) of patients with DTC. Methods:In DTC patients with adjuvant radioiodine therapy, we assessed retrospectively u-hsTg (6 ± 3 months before s-Tg measurement) and s-Tg measurements (≤24 months after last radioiodine therapy). Positive predictive (PPV)/negative predictive values (NPV) of various cut-off values (s-Tg: 0.5/1.0 ng/mL; u-hsTg: 0.09/0.2 ng/mL) for patient outcomes as well as additional factors associated with disease development were analyzed. Results:In total, 175 patients were retrospectively reviewed (tumor recurrence: n = 14/complete remission: n = 161). Examined cut-off values for s-Tg and u-hsTg showed significant predictive power for RFS (log-rank: all P < 0.001). NPV/PPV for s-Tg were 98.6%/36.4%, respectively (0.5 ng/mL cut-off) and 96.7%/42.9%, respectively (1.0 ng/mL cut-off); those for u-hsTg were 97.3%/35.7%, respectively (0.09 ng/mL cut-off) and 95.2%/85.7%, respectively (0.2 ng/mL cut-off). U-hsTg (P < 0.001) and patient age (P < 0.05) were significantly associated with tumor recurrence. One-third of patients with tumor recurrence in the course initially showed undetectable u-hsTg after completion of primary therapy. Conclusion:With >10 years of follow-up, both s-Tg and u-hsTg have a comparably high predictive power for RFS, while only u-hsTg was significantly associated with a recurrence event.Serial u-hsTg measurements seem warranted since patients with tumor recurrence during follow-up may have an undetectable tumor marker at baseline.
Autoimmune thyroid diseases (AITDs) include a wide spectrum of thyroid diseases affecting more commonly women than men. The most frequent forms are Graves' Disease (GD) and Hashimoto's thyroiditis / Autoimmune Thyroiditis (AIT), but there are also other immunogenic destructive forms of thyroiditis, that is, silent and postpartum thyroiditis. In the last decade, AITDs and other inflammatory thyroid diseases related to anti-tumor molecular drugs are more frequently seen due to the widespread use of tyrosine kinase inhibitors (TKIs) and immune checkpoint inhibitors (ICPIs). Autoimmune thyroiditis related to SARS-CoV-2 infection has been a novel entity in recent years. Graves' Disease and AIT may shift from hyperthyroidism to hypothyroidism, which may complicate the differential diagnosis and further treatment strategy. Moreover, all AITDs may manifest with thyrotoxicosis (a clinical condition marked with high serum levels of thyroid hormones) which has to be distinguished from hyperthyroidism (increased thyroid hormone production and secretion as a result of hyperfunctioning thyroid gland) due to different therapeutic approaches. Nuclear medicine techniques, such as radioiodine uptake (RAIU) and thyroid scintigraphy, using 99mTc- pertechnetate (Na[99mTc]TcO4) or 123-Iodine (Na[123I]I), have a crucial role in the differential diagnosis. Measurement of thyroid antibodies, e.g. thyroid peroxidase antibodies (TPO) and thyrotropin receptor antibodies (TRAb), as well as thyroid ultrasound, are complementary methods in the evaluation of thyroid disorders.
OBJECTIVE Thyroglobulin measurement is the cornerstone of modern management of differentiated thyroid cancer, with clinical decisions on treatment and follow-up based on the results of such measurements. However, numerous factors need to be considered regarding measurement with and interpretation of thyroglobulin assay results. DESIGN The present document provides an integrated update to the 2013 and 2014 separate clinical position papers of our group on these issues. METHODS Issues concerning analytical and clinical aspects of highly-sensitive thyroglobulin measurement will be reviewed and discussed based on an extensive analysis of the available literature. RESULTS Thyroglobulin measurement remains a highly complex process with many pitfalls and major sources of interference, especially anti-thyroglobulin antibodies, need to be assessed, considered and, when necessary, dealt with appropriately. CONCLUSIONS Our expert consensus group formulated 53 practical, graded recommendations for guidance on highly-sensitive thyroglobulin and TgAb in laboratory and clinical practice, especially valuable where current guidelines do not offer sufficient guidance.
Background. Differentiated thyroid carcinoma (DTC) is characterized by an excellent prognosis with a 10-year survival rate > 90%. However, when DTC develops in a metastatic form, it has been shown to significantly impact patient survival and quality of life. Although I-131 has been shown to be an effective therapy in patients with metastatic DTC, whether its efficacy after recombinant human TSH (rhTSH) is comparable to endogenous TSH stimulation by thyroid hormone deprivation (THW) is still debated. Our present study was prompted to compare clinical results obtained in metastatic DTC by I-131 administered after rhTSH and THW stimulation protocols, respectively. Methods. A systematic search on PubMed, Web of Science, and Scopus was performed from January to February 2023. Pooled risk ratios with 95% CI were determined for evaluating the initial response after to I-131 therapy after preparation with rhTSH or THW and the disease progression. To track the accumulation of evidence and reduce type I errors because of small data, a cumulative meta-analysis was performed. A sensitivity analysis was also performed to examine the impact of individual studies on overall prevalence results. Results. Ten studies were included with a total of 1929 patients pre-treated with rhTSH (n = 953) and THW (n = 976), respectively. The cumulative data of our systematic review and meta-analysis showed an increase in the risk ratio over the years without any change in favour of a pre-treatment or the other on the effectiveness of I-131 therapy of metastatic DTC. Conclusions. Our data suggest that pretreatment with rhTSH or THW has no significant impact on the effectiveness of I-131 therapy for metastatic DTC. This implies that concerns about the use of one or the other pretreatment should be deferred to clinical evaluations made considering patient characteristics and reduction in side effects.
An accurate postoperative assessment is pivotal to inform postoperative 131I treatment in patients with differentiated thyroid cancer (DTC). We developed a predictive model for post-treatment whole-body scintigraphy (PT-WBS) results (as a proxy for persistent disease) by adopting a decision tree model. Age, sex, histology, T stage, N stage, risk classes, remnant estimation, TSH, and Tg were identified as potential predictors and were put into regression algorithm (conditional inference tree, ctree) to develop a risk stratification model for predicting the presence of metastases in PT-WBS. The lymph node (N) stage identified a partition of the population into two subgroups (N-positive vs N-negative). Among N-positive patients, a Tg value > 23.3 ng/mL conferred a 83
Purpose: (i) To examine the criterion taller-than-wide (TTW) for the sonographic assessment of thyroid nodules in areas of iodine deficiency in terms of frequency, anatomical distribution within the thyroid gland and risk of malignancy. (ii) To develop a model for nodule growth in the thyroid gland. Methods: German multicenter study consisting of two parts. In the prospective part, thyroid nodules were sonographically measured in all three dimensions, location within the thyroid gland and contact to a protrusion-like formation (horn) in the dorsal position of thyroid gland was noted. In addition, further sonographic features such as the composition, echogenity, margins and calcifications were investigated. All nodules from the prospective part were assessed for malignancy as part of clinical routine at the decision of the treating physician adhering to institutionally based algorithms. In the retrospective part, only nodules with fine needle aspiration and/or histology were included. The risk of malignancy in TTW nodules was determined by correlating them with cyotological and histological results. Results: Prospective part: out of 441 consecutively evaluated thyroid nodules, 6 were found to be malignant (1.4%, 95% CI 0.6–2.7%). Among the 74 TTW nodules (17%), 1 was malignant (1%, 95% CI 0–4%). TTW nodules were more often located in the dorsal half of the thyroid than non-TTW nodules (factor 2.3, p = 0.01, 95% CI 2.1–2.5) and more often located in close proximity to a horn than non-TTW nodules (factor 3.0, p = 0.01, 95% CI 2.4–3.8). Retrospective part: out of 1315 histologically and/or cytologically confirmed thyroid nodules, 163 TTW nodules were retrieved and retrospectively analyzed. A TTW nodule was 1.7 times more often benign when it was dorsal (95% CI 1.1–2.5) and 2.5 times more often benign when it was associated with a horn (95% CI 1.2–5.3). The overall probability of malignancy for TTW nodules was 38% (95% CI 30–46%) in this highly preselected patient group. Conclusion: TTW nodules are common in iodine deficient areas. They are often located in the dorsal half of the thyroid gland and are frequently associated with a dorsal protrusion-like formation (horn) of the thyroid. Obviously, the shape of benign nodules follows distinct anatomical preconditions within the thyroid gland. The frequency of TTW nodules and their predominant benignity can be explained by a pole concept of goiter growth. The difference between the low malignancy risk of TTW nodules found on a prospective basis and the high risk found retrospectively may be the result of a positive preselection in the latter.
Aim Thyroid scintigraphy enables the depiction of the functional status of thyroid nodules (TNs) with both, 99mTc-pertechnetate and 123Iodine. The functional status is relevant for diagnostic procedures for the differentiation of benign and malignant TNs. The aim of this study was to examine the current frequencies of hyper-, hypo- and isofunctioning TNs in Germany and to estimate the risk of malignancy with regard to functional status. Methods In 11 study centers, a minimum of 100 nodules per center were consecutively enrolled between July 2019 and April 2020. Inclusion criteria were: newly diagnosed nodule, nodule’ size of 10 mm or more, thyroid scintigraphy. Exclusion criteria were: completely cystic TNs, patients with prior radioiodine therapy or thyroid surgery. The risk of malignancy was estimated for hyper- and hypofunctioning TNs. Results Overall, 849 patients (72 % women) with 1262 TNs were included. Patients’ age ranged from 18 to 90 years. Most TNs were hypofunctioning (n=535, 42%) followed by isofunctioning TNs (n=488, 39%) and hyperfunctioning TNs (n=239, 19%). When only TNs with a maximum size of 2 cm or more were considered the rate of hyperfunctioning and hypofunctioning TNs increased (to 27% and 49%) while isofunctioning TNs decreased. Only one of all hyperfunctioning TNs was malignant. In hypofunctioning nodules, the malignancy rate was estimated at 10%. Conclusion In Germany, the proportion of hyperfunctioning TNs is approximately 20% and increases in larger TNs to up to 27%. Due to the low risk of malignancy in hyperfunctioning TNs, no further procedures to rule out malignancy are necessary. The risk of malignancy of hypofunctioning TNs is significantly higher. Thus, a thyroid scintigraphy is a useful diagnostic tool in Germany.
Ziel/Aim 99mTc-MIBI wird zur Dignitätsabklärung von hypofunktionellen Schilddrüsenknoten eingesetzt. Dabei ist der hohe negative prädiktive Wert entscheidend, umgekehrt führt die niedrige Spezifität zu falsch-positiven Befunden. Für die Befundbeurteilung werden unterschiedliche Kriterien eingesetzt (visuelle Beurteilung, ggf. SPECT oder frühem MIBI-Uptake im Vgl. zur Spätaufnahme oder semiquantitativen Verfahren wie dem Washout-Index). Ziel dieser Studie war es, den diagnostischen Ablauf, die Akquisitionsparameter und die Befundbeurteilung auf europ. Ebene zu erfassen.
Ziel/Aim Ultraschall Risikostratifizierungssysteme (URSS) erlauben eine Malignitätsabschätzung von Schilddrüsenknoten und helfen bei der Entscheidungsfindung im diagnostischen Algorithmus. Daten aus (ehemaligen) Iodmangelgebieten zur diagnostischen Performance liegen jedoch nur unzureichend vor. Ziel der Studie war es, die diagnostische Performance von Kwak-, EU-, ACR- und Korean-TIRADS sowie der ATA-Klassifikation in Deutschland zu untersuchen.
Ziel/Aim Ermittlung der Verteilung szintigraphisch hyperfunktioneller („heißer; h“), hypofunktioneller („kalter; k“) und indifferenter („i“) Schilddrüsenknoten sowie der Malignitätsrate „h“ und „k“ Knoten in Deutschland, um den – in den letzten Jahren international kritisch hinterfragten – Stellenwert der Schilddrüsenszintigraphie im Abklärungsalgorithmus von Schilddrüsenknoten zu eruieren, da es hierzu keine aktuellen nationalen Daten gibt.
99mTc-MIBI (MIBI) imaging is able to exclude malignancy of hypofunctioning thyroid nodules (TNs) with high probability but false positive results are frequent due to low specificity. Therefore, pre-test selection of appropriate TNs is crucial. For image evaluation visual and semiquantitative methods (Washout index, WOInd) are used. Aim of this study was to evaluate the diagnostic performance of MIBI imaging in hypofunctioning TNs with indeterminate fine-needle aspiration cytology results in a multicentric European setting. Patients with hypofunctioning TNs, EU-TIRADS 4 or 5, Bethesda III/IV and MIBI imaging were included. For visual evaluation the intensity of MIBI uptake in the TN was compared to normal thyroid tissue. 358 patients with 365 TNs (n = 68 malignant) were included. Planar imaging (SPECT) showed a sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of 96% (94%), 21% (22%), 22% (15%), 96% (96%), and 35% (32%). The WOInd (38.9% of all cases, optimal cutoff: −19%) showed a sens 100% (spec 89%, PPV 82%, NPV 100%, ACC 93%). For hypofunctioning TNs at intermediate or high risk with indeterminate cytology, a MIBI negative result on visual evaluation is an effective tool to rule-out thyroid malignancy. The semi-quantitative method could considerably improve overall diagnostic performance of MIBI imaging.
Objective: In patients with differentiated thyroid cancer (DTC), recurrenc es may occur in up to 20% and may have a fatal outcome in 10% of cases. Thyr oglobulin doubling time (Tg-DT) values may contribute to predict response to treat ment and disease recurrence in DTC patients. This study aimed to address the fol lowing questions: (1) Are Tg-DT values indicative of response to treatments in patients w ith DTC (i.e. ’treatment monitoring’)?; (2) Is Tg-DT predictive of 2-[18F]fluoro-2-deoxy-d-glucose (2-[18F]FDG) PET/CT in patients with DTC?; (3) Are Tg-DT values predictive o f DTC prognosis (i.e. ‘prediction’)? Design: Systematic review and meta-analysis. Methods: Methodology was registered in the PROSPERO database (CRD420212 57947). A systematic search was carried out in PubMed, Web Of Science, and Scopus from June to August 2021 without time and language restrictions. Results: Eleven studies were included for a total of 1421 patients. Positive association between Tg-DT < 1 year and recurrence or disease progression wa s observed. Tg-DT was found to be related with (2-[18F]FDG) PET/CT results in pat ients with DTC. The area under the curve was 0.86 (95% CI: 0.83–0.89), sensitivity was 0 .84 (0.64;0.94), specificity was 0.71 (0.35; 0.92), DOR was 13.1 (3.1; 55.0), LR+ was 2.9 (1 .0; 8.1), LR− was 0.22 (0.1; 0.5). For patients with Tg-DT < 1 year ( n = 247), the survival risk ratio was 2.09 (95% CI: 1.49; 2.94). Conclusions: Tg-DT values are valuable in predicting response to treatment and disease recurrence in patients with DTC, as well as their overall survi val. In addition, Tg-DT significantly increases the detection rate of 2-[18F]-FDG PET/CT.