A new frequency-stepped Doppler backscattering (DBS) system has been integrated into a real-time steerable electron cyclotron heating launcher system to simultaneously probe local background turbulence (f < 10 MHz) and high-frequency (20-550 MHz) density fluctuations in the DIII-D tokamak. The launcher allows for 2D steering (horizontally and vertically) over wide angular ranges to optimize probe location and wavenumber response. The vertical steering can be optimized during a discharge in real time. The new DBS system employs a programmable frequency synthesizer with adjustable dwell time as a source to launch either O or X-mode polarized millimeter waves. This system can step in real-time over the entire E-band frequency range (60-90 GHz). This combination of capabilities allows for the diagnosis of the complex internal spatial structure of high power (>200 kW) helicon waves (476 MHz) injected from an external antenna during helicon current drive experiments in DIII-D. Broadband density fluctuations around the helicon frequency are observed during real-time scans of measurement location and wavenumber during these experiments. Analysis indicates that these broadband high-frequency fluctuations are a result of backscattering of the DBS millimeter-wave probe beam from plasma turbulence modulated by the helicon wave. It is observed that background turbulence is effectively locally "tagged" with the helicon wave electric field, forming images of the turbulent spectrum in the overall density fluctuation spectrum that appear as high-frequency sidebands of the turbulence. These observations of background turbulence and high-frequency fluctuations open up the possibility of monitoring local helicon wave amplitude by comparing the high-frequency signal amplitude to the simultaneously measured background turbulence. In combination with the real-time measurement location and wavenumber scanning capabilities (offered by real-time frequency-stepping and steering), this allows rapid determination of the spatial distribution of the helicon wave power during steady-state plasma operation. In the long term, such measurements may be used to validate predictive modeling (GENRAY [Smirnov and Harvey, Bull. Am. Phys. Soc. 40, 1837 (1995)] or AORSA [Lau et al., Nucl. Fusion 58 066004 (2018)]) of helicon current drive in DIII-D plasmas.
Validated and accurate edge profiles (temperature, density, etc.) are vitally important to the Mega Ampere Spherical Tokamak Upgrade (MAST-U) divertor and confinement effort. Density profile reflectometry has the potential to significantly add to the measurement capabilities currently available on MAST-U (e.g., Thomson scattering and Langmuir probes). This work presents the diagnostic requirements, problems, and solutions facing profile reflectometry in spherical tokamaks and MAST-U in particular. Requirements include density measurements near zero electron density in the scrape off layer region, coverage for a broad range of MAST-U plasma parameters, high time (≤10 microseconds) and spatial resolutions (≤1 cm), reliability, and identification of the plasma start frequency.
A set of new millimeter-wave diagnostics will deliver unique measurement capabilities for National Spherical Torus Experiment-Upgrade to address a variety of plasma instabilities believed to be important in determining thermal and particle transport, such as micro-tearing, global Alfven eigenmodes, kinetic ballooning, trapped electron, and electron temperature gradient modes. These diagnostics include a new integrated intermediate-k Doppler backscattering (DBS) and cross-polarization scattering (CPS) system (four channels, 82.5-87 GHz) to measure density and magnetic fluctuations, respectively. The system can access reasonably large normalized wavenumbers k(theta)rho(s) ranging from <= 0.5 to 15 (where ion sound gyroradius rho(s) = 1 cm and k(theta) is the binormal density turbulence wavenumber). The system addresses the challenges for making useful DBS/CPS measurements with a remote control of launch polarization (X- or O-mode), probed wavenumber, polarization match of the launch beam with the edge magnetic field pitch angle, and beam steering of the launched beam for wave-vector alignment. In addition, a low-k DBS system consisting of eight fixed frequencies (34-52 GHz) and four tunable frequencies (55-75 GHz) for low-k density turbulence and fast ion physics will be located at a nearby port location. The combined systems cover the near LCFS and pedestal regions (34-52 GHz), the pedestal or mid-radius (50-75 GHz), and core plasmas (82.5-87 GHz).
We present the design and laboratory tests for a new Q-band frequency tunable Doppler backscattering (DBS) system suitable for probing poloidal wavenumber kñ = 6–8 cm−1 density fluctuations and their flow velocities in the pedestal and scape-off layer (SOL) of the DIII-D tokamak. This system will provide new measurements in the increasingly important and under-diagnosed far pedestal and SOL plasma regions. These results are important for experimental transport studies and necessary for the validation of transport models, both of which are important to fusion energy research. The use of a single tunable frequency reduces the complexity and potential failure points as compared to a multichannel system. This new system utilizes a 33–50 GHz tunable source and will be integrated into the current V-band DBS in DIII-D using a broadband Q- and V-band multiplexer. A full-scale mockup of the quasi-optical system was used to test and optimize the performance. These tests include beam profile measurements at different distances (and angles) from a paraboloidal focusing and steering mirror. The measurements cover the full frequency range 33–75 GHz of the integrated/combined Q–V band DBS system and target a large radial coverage of the low-field side of the plasma from ρ = 1.1 to ρ = 0.5, where ρ is the normalized flux surface radial coordinate.
The fixed-frequency and frequency-modulated continuous-wave (FM-CW) reflectometers on LTX-beta (Lithium Tokamak eXperiment-beta) have been configured to use the same transmission lines and antenna arrays for coincident views of the core and edge plasma. The fixed-frequency channels (13.1-20.5 and 20-40 GHz, tunable between discharges) provide time-resolved measurements of density fluctuations, while the FM-CW channels (13.1-20.2 and 19.5-33.5 GHz) measure the density profile and fluctuations, with high spatial resolution and a sampling rate determined by the frequency sweep interval (5 mu s). Data from both reflectometers are synchronously acquired to simultaneously leverage the wide bandwidth and high spatial resolution of the respective systems. Experiments showed that mutual crosstalk interference is momentary and does not diminish the capability of either system. Spectral analysis indicated broad power spectra (several hundreds of kHz) and suggests that the signals from the FM-CW system are consistent with under-sampled fixed-frequency signals. Radial correlations were explored using data from the two reflectometers, as well as from the FM-CW system alone. The core channels showed high levels of agreement between these two comparisons, suggesting that the data from the reflectometers are interchangeable for statistical estimates. For the edge channels, comparisons using data from the FM-CW reflectometer alone showed significant decorrelation due to time lag caused by the finite frequency up-sweep duration. Alternatively, this effect is eliminated when cross-correlating data from the different reflectometers. These results highlight the advantages of operating the fixed-frequency and FM-CW reflectometers in this manner, where the combined system can overcome the limitations of each separate system.
A novel quadrature Doppler Backscattering (DBS) system has been developed and optimized for the E-band (60-90 GHz) frequency range using either O-mode or X-mode polarization in DIII-D plasmas. In general, DBS measures the amplitude of density fluctuations and their velocity in the lab frame. The system can simultaneously monitor both low-frequency turbulence (f < 10 MHz) and radiofrequency plasma density fluctuations over a selectable frequency range (20-500 MHz). Detection of high-frequency fluctuations has been demonstrated for low harmonics of the ion cyclotron frequency (e.g., 2fci ∼ 23 MHz) and externally driven high-frequency helicon waves (f = 476 MHz) using an adjustable frequency down conversion system. Importantly, this extends the application of DBS to a high-frequency spectral domain while maintaining important turbulence and flow measurement capabilities. This unique system has low phase noise, good temporal resolution (sub-millisecond), and excellent wavenumber coverage (kθ ∼ 1-20 cm-1 and kr ≲ 30 cm-1). As a demonstration, localized internal DIII-D plasma measurements are presented from turbulence (f ≤ 5 MHz), Alfvenic waves (f ∼ 6.5 MHz), ion cyclotron waves (f ≥ 20 MHz), as well as fluctuations around 476 MHz driven by an external high-power 476 MHz helicon wave antenna. In the future, helicon measurements will be used to validate GENRAY and AORSA modeling tools for prediction of helicon wave propagation, absorption, and current drive location for the newly installed helicon current drive system on DIII-D.
The high density fluctuation poloidal wavenumber, kθ (kθ > 8 cm-1, kθρs > 5, ρs is the ion gyro radius using the ion sound velocity), measurement capability of a new Doppler backscattering (DBS) system at the DIII-D tokamak has been experimentally evaluated. In DBS, wavenumber (k) matching becomes more important at higher wavenumbers, owing to the exponential dependence of the measured signal loss factor on wave vector mismatch. Wave vector matching allows for the Bragg scattering condition to be satisfied, which minimizes the signal loss at higher k's. In the previous DBS system, without toroidal wave vector matching, the measured DBS signal-to-noise ratio at higher kθ (>8 cm-1) is substantially reduced, making it difficult to measure higher kθ turbulence. The new DBS system has been optimized to access higher wavenumber, kθ ≤ 20 cm-1, density turbulence measurement. The optimization hardware addresses fluctuation wave vector matching using toroidal steering of the launch mirror to produce a backscattered signal with improved intensity. The probe's sensitivity to high-k density fluctuations has been increased by approximately an order of magnitude compared to the old system that has been in use at DIII-D. Note that typical measurement locations are above or below the tokamak midplane on the low field side with normalized radial ranges of 0.5-1.0. The new DBS probe system with the toroidal matching of fluctuation wave vectors is thought to be critical to understanding high-k turbulent transport in fusion-relevant research at DIII-D.
A new Doppler backscattering (DBS) system has been installed and tested on the MAST-U spherical tokamak. It utilizes eight simultaneous fixed frequency probe beams (32.5, 35, 37.5, 40, 42.5, 45, 47.5, and 50 GHz). These frequencies provide a range of radial positions from the edge plasma to the core depending on plasma conditions. The system utilizes a combination of novel features to provide remote control of the probed density wavenumber, the launched polarization (X vs O-mode), and the angle of the launched DBS to match the magnetic field pitch angle. The range of accessible density turbulence wavenumbers (kθ) is reasonably large with normalized wavenumbers kθρs ranging from ≤0.5 to 9 (ion sound gyroradius ρs = 1 cm). This wavenumber range is relevant to a variety of instabilities believed to be important in establishing plasma transport (e.g., ion temperature gradient, trapped electron, electron temperature gradient, micro-tearing, kinetic ballooning modes). The system is specifically designed to address the requirement of density fluctuation wavevector alignment which can significantly reduce the SNR if not accounted for.
DIII-D research is addressing critical challenges in preparation for ITER and the next generation of fusion devices through focusing on plasma physics fundamentals that underpin key fusion goals, understanding the interaction of disparate core and boundary plasma physics, and developing integrated scenarios for achieving high performance fusion regimes. Fundamental investigations into fusion energy science find that anomalous dissipation of runaway electrons (RE) that arise following a disruption is likely due to interactions with RE-driven kinetic instabilities, some of which have been directly observed, opening a new avenue for RE energy dissipation using naturally excited waves. Dimensionless parameter scaling of intrinsic rotation and gyrokinetic simulations give a predicted ITER rotation profile with significant turbulence stabilization. Coherence imaging spectroscopy confirms near sonic flow throughout the divertor towards the target, which may account for the convection-dominated parallel heat flux. Core-boundary integration studies show that the small angle slot divertor achieves detachment at lower density and extends plasma cooling across the divertor target plate, which is essential for controlling heat flux and erosion. The Super H-mode regime has been extended to high plasma current (2.0 MA) and density to achieve very high pedestal pressures (similar to 30 kPa) and stored energy (3.2 MJ) with H-98y2 approximate to 1.6-2.4. In scenario work, the ITER baseline Q = 10 scenario with zero injected torque is found to have a fusion gain metric beta(TE) independent of current between q(95) = 2.8-3.7, and a lower limit of pedestal rotation for RMP ELM suppression has been found. In the wide pedestal QH-mode regime that exhibits improved performance and no ELMs, the start-up counter torque has been eliminated so that the entire discharge uses approximate to 0 injected torque and the operating space is more ITER-relevant. Finally, the high-beta(N) (<= 3.8) hybrid scenario has been extended to the high-density levels necessary for radiating divertor operation, achieving similar to 40% divertor heat flux reduction using either argon or neon with P-tot up to 15 MW.
Real-time phase calibration of the ITER profile reflectometer is essential due to the long plasma duration and expected waveguide path length changes during a discharge. Progress has been recently made in addressing this issue by employing a phase calibration technique on DIII-D that monitors calibration variations that occur during each plasma discharge. By installing a thin free-standing metallic wire (1 mm diameter) near the end of the overmoded waveguide transmission system (oriented perpendicular to the waveguide axis), the round-trip phase shift from the wire is detected simultaneously with the plasma phase shifts. Variations in the reflectometer round trip path length (∼26 m) are then calculated after each DIII-D plasma discharge, allowing the calibration phase to be accurately monitored and updated. The round-trip reflectometer path length is observed to vary by ∼3 mm (root mean square value) during a typical DIII-D discharge. Using the variations in calibration phase, the density profile measurement accuracy can be improved. Since the wire retro-reflected power is ∼0.01 of the plasma signal, minimal effect is observed on the reflected signal from the plasma. Importantly, through a suitable choice in wire diameter, the calibration signal can be made approximately independent of the V-band reflectometer launch polarization. This is particularly important on DIII-D since orthogonal X- and O-mode polarized beams are coupled into the same transmission waveguide and launch antenna.
The λ ≈ 1 mm (f = 288 GHz) interferometer for the Lithium Tokamak Experiment-β (LTX-β) will use a chirped-frequency source and a centerstack-mounted retro-reflector mirror to provide electron line density measurements along a single radial chord at the midplane. The interferometer is unique in the use of a single source (narrow-band chirped-frequency interferometry) and a single beam splitter for separating and recombining the probe and reference beams. The current work provides a documentation of the interferometry hardware and evaluates the capabilities of the system as a far-forward collective scattering diagnostic. As such, the current optical setup is estimated to have a detection range of 0.4 ≲ k ⊥ ≲ 1.7 cm-1, while an improved layout will extend the upper k ⊥ limit to ∼3 cm-1. Measurements with the diagnostic on LTX are presented, showing interferometry results and scattered signal data. These diagnostics are expected to provide routine measurements on LTX-β for high frequency coherent density oscillations (e.g., Alfvénic modes during neutral beam injection) as well as for broadband turbulence.
Simulations and laboratory tests are used to design and optimize a quasi-optical system for cross-polarization scattering (CPS) measurements of magnetic turbulence on the DIII-D tokamak. The CPS technique uses a process where magnetic turbulence scatters electromagnetic radiation into the perpendicular polarization enabling a local measurement of the perturbing magnetic fluctuations. This is a challenging measurement that addresses the contribution of magnetic turbulence to anomalous thermal transport in fusion research relevant plasmas. The goal of the new quasi-optical design is to demonstrate the full spatial and wavenumber capabilities of the CPS diagnostic. The approach used consists of independently controlled and in vacuo aiming systems for the probe and scattered beams (55-75 GHz).
A new eight-channel correlation electron cyclotron emission diagnostic has recently been installed on the DIII-D tokamak to study both turbulent and coherent electron temperature fluctuations under various plasma conditions and locations. This unique system is designed to cover a broad range of operation space on DIII-D (1.6-2.1 T, detection frequency: 72-108 GHz) via four remotely selected local oscillators (80, 88, 96, and 104 GHz). Eight radial locations are measured simultaneously in a single discharge covering as much as half the minor radius. In this paper, we present design details of the quasi-optical system, the receiver, as well as representative data illustrating operation of the system.