The number of fluoroscopy-guided interventional procedures has increased in recent years due to their significant patient benefits. However, occupational radiation risks for interventionalists remain among the highest in medical practices. Electronic personal dosimeters can measure occupational doses for individual procedures, enabling immediate optimisation actions. An information system that effectively aggregates these records proves to be a powerful tool for this optimisation. Furthermore, implementing alerts to identify abnormal occupational doses is a practical method to improve radiation protection for interventionists. Electronic dosimeters were linked with the X-ray system to record both the occupational and patient doses on a per-procedure basis. The information, stored in a central database, is used to compute dose indicators and trigger alerts that warn operators about specific areas requiring optimisation. The results from the first 9 months of 2024 were analysed, covering 3 interventional cardiology rooms and 2 interventional radiology rooms, with 19 interventionalists (8 cardiologists and 11 radiologists) performing a total of 3373 procedures. The initial alerts were configured on the basis of regulatory dose limits and the third quartile of occupational dose per procedure, as well as the ratio of occupational dose to kerma area product per procedure and the ratio between occupational dose and the C-arm measured dose. These alerts, along with personal dose data and other dosimetry information, are accessible to interventionalists and medical physics experts. This information system provides detailed, structured occupational dose data necessary to implement targeted optimisation measures.
Purpose The European Union Radiation, Education, Staffing & Training (EU-REST) study aimed to assess workforce availability and identify education and training needs related to the medical use of ionising radiation. The study also sought to develop guidelines on staffing and education/training for key professional groups, including Medical Physics Experts (MPEs), responsible for ensuring radiation safety and quality of medical radiation practice across the EU. Methods A survey was conducted to collect data about workforce availability, and education/training across the EU, as well as a literature review encompassing national, European, and international guidelines. Draft guidelines and recommendations were submitted for peer review and stakeholder consultation for assessment and identification of potential barriers to implementation. Results The survey revealed considerable variability in staffing and education/training across the EU, as well as a widespread lack of reliable data. The study highlights the need to reinforce the role of MPE as the qualified professional for advising and taking responsibility in matters related to radiation physics and radiation protection applied to medical exposures. Establishing national workforce registries, harmonising training standards, ensuring professional recognition, and mandating CPD are strategic recommendations for strengthening the MPE profession in response to emerging technological and regulatory demands. These represent essential steps toward a sustainable, competent, and mobile MPEs workforce across Europe. Conclusion The EU-REST project echoes the European Commission’s call for further harmonisation of the MPEs role across Member States, in accordance with the Basic Safety Standards Directive, and provides targeted recommendations to facilitate its consistent implementation throughout the EU.
Purpose Ophthalmic brachytherapy treats eye lesions by stitching plaques containing a radionuclide (e.g. Ru-106) onto the sclera. Compliance with quality assurance standards is crucial, but practical limitations complicate independent source strength measurement in clinical practice. In this article, a new prototype for acceptance testing of Ru-106 plaques is assayed to assess its suitability for a hospital’s medical physics department. Methods and Materials The system designed for Ru-106 plaque assessment, includes a phantom basin fillable with water, a Si-diode for electrons coupled with an electrometer, type-dependent plaque holders and a micrometre gauge. Testing involved the measurement of three plaque types (CCA, CIB, COB) by six medical physics experts and trainees, the assessment of inter and intra-observer variability and the suitability for measurement at the reference point, 2mm. Results Measured absorbed dose rates in water at 2mm from the plaque surface demonstrated compatibility across all testers for the three plaques. Intra and inter-observer variability was minimal (1.0% and 1.3% of the measured value, respectively), confirming system robustness in terms of operator influence. Conclusions The system proves suitable for Ru-106 plaque acceptance testing, ensuring accurate plaque positioning and dose rate verification at 2mm. These findings confirm its potential as a support for compliance with quality assurance standards. These results are subject to the issue of the corresponding calibration certificate for the Si-diode.
The European Union Radiation, Education, Staffing & Training (EU-REST) study was a European Commission-funded, 24-month project that analysed workforce availability, education and training needs to ensure quality and safety aspects of medical applications involving ionising radiation in the EU and developed staffing and education/training guidelines for key professional groups involved in ensuring radiation safety and quality of medical radiation applications in the EU Member States. This article outlines the origin, development, goals and overall structure of the project. CRITICAL RELEVANCE STATEMENT: This article provides a concise overview of the EU-REST project, which analysed the workforce availability of health professionals involved in the use of ionising radiation for diagnostic and therapeutic procedures and the corresponding education and training in radiation protection. KEY POINTS: The aims, professional groups, components, and findings of The European Union Radiation, Education, Staffing & Training (EU-REST) study are described. The limited amount of data and literature on staffing recommendations constituted an important finding of the project. One of the study's recommendations is for each EU Member State to maintain a central registry of professionals involved in ionising radiation as well as on related equipment.
PURPOSE:Dose management systems (DMS) have been introduced in radiological services to facilitate patient radiation dose management and optimization in medical imaging. The purpose of this study was to gather as much information as possible on the technical characteristics of DMS currently available, regarding features that may be considered essential for simply ensuring regulatory compliance or desirable to fully utilize the potential role of DMS in optimization of many aspects of radiological examinations.METHODS:A technical survey was carried out and all DMS developers currently available (both commercial and open source) were contacted and were asked to participate. An extensive questionnaire was prepared and uploaded in the IAEA International Research Integration System (IRIS) online platform which was used for data collection process. Most of the questions (93%) required a "Yes/No" answer, to facilitate an objective analysis of the survey results. Some free text questions and comments' slots were also included, to allow participants to give additional information and clarifications where necessary. Depending on the answer, they were considered either as "Yes" or "No."RESULTS:Given the way that the questions were posed, every positive response indicated that a feature was offered. Thus, the percentage of positive responses was used as a measure of adherence. The percentages of positive answers per section (and sub-section) are presented in graphs and limitations of this type of analysis are discussed in detail.CONCLUSIONS:The results of this survey clearly exhibit that large differences exist between the various DMS developers. Consequently, potential end users of a DMS should carefully determine which of the features available are essential for their needs, prioritize desirable features, but also consider their infrastructure, the level of support required and the budget available before selecting a DMS.
Occupational protection could be improved in interventional radiology. The monthly personal dosimetry cannot alert on some occupational doses with anomalous values for certain procedures. Active electronic personal dosimeters linked wireless to a dose management system (DMS), allow for the measurement of occupational doses per procedure, integrating this information with patient dose indicators and with technical and geometrical conditions of the procedures.We analysed around 3100 occupational dose values for individual procedures collected during the last two years, in an interventional radiology laboratory of a University Hospital and two groups, with patient doses higher than 100 Gy.cm2, and lower than 30 Gy.cm2.An unshielded reference dosimeter located at the C-arm registers the ambient dose equivalent (ADE) per procedure to be compared with the personal dose equivalent (PDE) over the apron. The ratio between both values PDE/ADE is a good indication of occupational protection. Alerts for occupational protection optimisation are suggested.For the full sample, 8.4 % of occupational doses measured over the protective apron of the interventionists were higher than 100 µSv and 3.8 % higher than 200 µSv per procedure. Occupational protection for complex procedures (>100 Gy.cm2) had median values of 46 µSv for PDE and 3.3 % for PDE/ADE. However, for simple procedures, (<30 Gy.cm2) the median values were 10 µSv and 28.4 %. This last percentage is 9 times higher than the value for complex procedures. This lack of protection should be corrected and the need to reduce some occupational doses reinforced in radiation protection training programmes for interventionists.
This study presents the performance of two fast Monte Carlo codes, PENELOPE/penEasyIR and MCGPU-IR in order to assess operator doses in interventional radiology. In particular, it aims to validate the calculations when workers are protected with shielding located between the patient and the operator. The experiments are performed in a calibration laboratory and measurements are gathered using Thermo EPD and Mirion DMC personal active dosemeters. Calculation efficiency of the fast Monte Carlo codes is approximately four orders of magnitude greater than for a standard Monte Carlo code. Satisfactory agreement between measurements and calculations is shown.
Interventional cardiology provides indisputable benefits for patients but uses a substantial amount of ionising radiation. The diagnostic reference level (DRL) is the tool recommended by the International Commission on Radiological Protection to optimise imaging procedures. In this work, a review of studies dealing with radiation dose or recommending DRL values for interventional cardiology since 2010 is presented, providing quantitative and qualitative results. There are many published papers on coronary angiography (CA) and percutaneous coronary intervention. The DRL values compiled for different continental regions are different: the DRL for CA is about 35 Gy cm(2) for Europe and 83 Gy cm(2) for North America. These differences emphasise the need to establish national DRLs considering different social and/or economic factors and the harmonisation of the survey methodology. Surveys with a large amount of data collected with the help of dose management systems provide more reliable information with less chance of statistical bias than those with a small amount of data. The complexity of procedures and improvements in technology are important factors that affect the radiation dose delivered to patients. There is a need for additional data on structural and electrophysiological procedures. The analysis of paediatric procedures is especially difficult because some studies present results split into age bands and others into weight bands. Diagnostic procedures are better described, but there is a great variety of therapeutic procedures with different DRL values (up to a factor of nine) and these require a dedicated review.
Objectives: Radiation dose management systems (DMS) are currently used to help improve radiation protection in medical imaging and interventions. This study presents our experience using a homemade DMS called DOLQA (Dose On-Line for Quality Assurance). Methods: Our DMS is connected to 14 X-ray systems in a university hospital linked to the central data repository of a large network of 16 public hospitals in the Autonomous Community of Madrid, with 6.7 million inhabitants. The system allows us to manage individual patient dose data and groups of procedures with the same clinical indications, and compare them with diagnostic reference levels (DRLs). The system can also help to prioritise optimisation actions. Results: This study includes results of imaging examinations from 2020, with 37,601 procedures and 286,471 radiation events included in the radiation dose structured reports (RDSR), for computed tomography (CT), interventional procedures, positron emission tomography-CT (PET-CT) and mammography. Conclusions: The benefits of the system include: automatic registration and management of patient doses, creation of dose reports for patients, information on recurrent examinations, high dose alerts, and help to define optimisation actions. The system requires the support of medical physicists and implication of radiologists and radiographers. DMSs must undergo periodic quality controls and audit reports must be drawn up and submitted to the hospital’s quality committee. The drawbacks of DMSs include the need for continuous external support (medical physics experts, radiologists, radiographers, technical services of imaging equipment and hospital informatics services) and the need to include data on clinical indication for the imaging procedures. Advances in knowledge: DMS perform automatic management of radiation doses, produces patient dose reports, and registers high dose alerts to suggest optimisation actions. Benefits and limitations are derived from the practical experience in a large university hospital.
It is relevant to estimate the uncertainties in the measurement of eye lens doses from a personal dosimeter over the protective apron without using additional dosimetry near the eyes. Additional dosimetry for interventionists represents a difficulty for routine clinical practice. This study analyses the estimated eye doses from dosimeter values taken at chest level over the apron and their uncertainties. Measurements ofHp(0.07) using optically stimulated luminescence dosimeters located on the chest over the apron and on the glasses (in the inner and outer part of the protection) were taken from ten interventionalists in a university hospital, in the period 2018-2019 during standard clinical practice. For a total sample of 133 interventional procedures included in our study, the ratio between theHp(0.07) on the glasses (left-outer side) and on the chest over the apron had an average of 0.74, with quartiles of 0.47, 0.64, 0.88. Statistically significant differences were found among operators using the U-Mann-Whitney test. The average transmission factor for the glasses was 0.30, with quartiles of 0.21, 0.25, and 0.32. Different complexity in the procedures, in the quality of the scatter radiation and in the individual operational practices, involve a relevant dispersion in the results for lens dose estimations from the over apron dosimeter. Lens doses may be between a 64% and an 88% of the over apron dosimeter values (using median or 3rd quartile). The use of 88% may be a conservative approach.
OBJECTIVES:The International Commission on Radiological Protection recommends managing patient and occupational doses as an integrated approach, for the optimisation of interventional procedures. The conventional passive personal dosimeters only allow one to know the accumulated occupational doses during a certain period of time. This information is not enough to identify if there is a lack of occupational radiation protection during some procedures. This paper describes the use of a dose management system (DMS) allowing patient and occupational doses for individual procedures to be audited.METHODS:The DMS manages patient and occupational doses measured by electronic personal dosimeters. One dosemeter located at the C-arm is used as a reference for scatter radiation. Data have been collected from five interventional rooms. Dosimetry data can be managed for the whole procedure and the different radiation events. Optimisation is done through auditing different sets of parameters for individual procedures: patient dose indicators, occupational dose values, the ratio between occupational doses, and the doses measured by the reference dosemeter at the C-arm, and the ratio between occupational and patient dose values.RESULTS:The managed data correspond to the year 2021, with around 4500 procedures, and 8000 records on occupational exposures. Patient and staff dose data (for 11 cardiologists, 7 radiologists and 8 nurses) were available for 3043 procedures. The DMS allows alerts for patient dose indicators and occupational exposures to be set.CONCLUSIONS:The main advantage of this integrated approach is the capacity to improve radiation safety for patients and workers together, auditing alerts for individual procedures.ADVANCES IN KNOWLEDGE:The management of patient and occupational doses together (measured with electronic personal dosimeters) for individual interventional procedures, using dose management systems, allows alerting optimisation on high-dose values for patients and staff.
Introduction: Extracranial internal carotid artery (ICA) pseudoaneurysms in children, although uncommon, are life threatening. Covered stents are a good alternative treatment, as they avoid the risk of open surgery and preserve the ICA. Until recently, long term outcomes were unknown. Report: A three year old boy was hospitalised with an enlarged swelling on the left side of his neck and severe respiratory distress. He had been treated a month prior for a left deep cervical abscess, with bacteriological culture positive for Staphylococcus aureus. Computed tomography angiography (CTA) revealed a large pseudoaneurysm originating from the left ICA, approximately 2 cm above the bifurcation. A balloon expanded covered stent (Jostent Graftmaster; Abbott Vascular, Redwood City, CA, USA) was deployed via a left femoral approach, after selective angiography, to seal the carotid rupture without incident. Control angiography revealed immediate exclusion of the pseudoaneurysm and patent ICA. The bacteriological culture of the residual haematoma was negative. The child was discharged with full recovery and without neurological sequelae, under platelet anti-aggregation. He has been followed up and has remained asymptomatic for 12 years, with CTA confirmed ICA patency, without deformation or evidence of significant restenosis. Discussion: This is the first report of the long term outcome of a covered stent in a child treated at three years of age, with a 12 year follow up. The good performance of the covered stent in this case reinforces its adoption as a first line option in the treatment of extracranial ICA pseudoaneurysms in children.
Abstract Purpose This study presents a prototype smartphone application for occupational dosimetry in interventional practices based on electronic personal dosimeters to assist in dose monitoring. Methods The prototype receives and records information from the occupational dose report containing the cumulative dose of electronic personal dosimeters worn over the apron at chest level and electronic area dosimeters located on C‐arms (reference dosimeters), for each fluoroscopy‐guided procedure. Using their smartphones, personnel involved in interventional practices can review and compare their occupational records with an investigation level, the dose limits, and their department colleagues (anonymously). The ratio between H p(10) measured by the personal and the reference dosimeters at the C‐arm is presented as an indicator of consistent use of suspended operator shield. Some general results extracted from the first months of use are presented. Results The reference dosimeter located at the C‐arm (without lead protection and acting as an ambient dosimeter) recorded in one of the laboratories 217 mSv during 308 procedures over 5 months, showing an indication of the radiation risk present in an interventional laboratory. The ratio between the personal cumulative dose and the dose at a reference C‐arm dosimeter ranged from 0.2% to 1.67% (a factor of 8.5) for different interventionalists. These differences suggest different protection habits among interventional operators, as well as a target for dose reduction. Conclusions With this system, professionals have easy access to their occupational dosimetry records (including information on the workload) in the setting of their interventional departments, to thereby actively engage in the protection process.
Objectives: In fluoroscopy-guided interventional practices, new dose reduction systems have proved to be efficient in the reduction of patient doses. However, it is not clear whether this reduction in patient dose is proportionally transferred to operators' doses. This work investigates the secondary radiation fields produced by two kinds of interventional cardiology units from the same manufacturer with and without dose reduction systems. Methods: Data collected from a large sample of clinical procedures over a 2-year period (more than 5000 procedures and 340,000 radiation events) and the DICOM radiation dose structured reports were analysed. Results: The average cumulative H-p(10) per procedure measured at the C-arm was similar for the standard and the dose reduction systems (452 vs 476 mu Sv respectively). The events analysis showed that the ratio H-p(10)/KAP at the C-arm was (mean +/- SD) 5 +/- 2, 10 +/- 4, 14 +/- 4 and 14 +/- 6 1.mu Sv.Gy(-1), cm(-2) for the beams with no added filtration, 0.1, 0.4 and 0.9 mm Cu respectively and suggested that the main cause for the increment of the ratio H-p(10)/KAP vs the "standard system" is the use of higher beam filtration in the ''dose reduction" system. Conclusion: Dose reduction systems are beneficial to reduce KAP in patients and their use should be encouraged, but they may not be equally effective to reduce occupational doses. Interventionalists should not overlook their own personal protection when using new technologies with dose reduction systems. Advances in knowledge: Dose reduction technology in interventional systems may increase scatter dose for operators. Personal protection should not be overlooked with dose reduction systems. Advances in knowledge: Dose reduction technology in interventional systems may increase scatter dose for operators. Personal protection should not be overlooked with dose reduction systems.
Aims Several novel low-dose fluoroscopic systems (LDS) developed recently, but real practice information of the net benefit for the patient and professionals is scarce. We evaluated separately patient and operator radiation exposure during percutaneous interventions of chronic total occlusions (CTO). Methods A total of 116 consecutive CTOs were analyzed (60 in LDS and 56 in standard-dose fluoroscopic system [SDS]). Digital dosimetry of patient and occupational (operator and scatter dose) exposure was prospectively recorded. Results Biometrics, demographics, CTO variables, and operators were distributed evenly. Patient radiation exposure was effectively decreased in LDS (dose area product [DAP] by 36%, Air Kerma [AK] by 47%). However, occupational data showed no statistical differences between LDS and SDS. The LDS uses less radiation amount but with higher energy (due to additional filtration) compared to SDS, therefore increasing the scatter dose. When comparing the C-arm scatter dose to the DAP we found higher scatter dose with the LDS (0.0139 mSv/gray (Gy)*cm2 vs. 0.0082 mSv/Gy*cm2,p < .001). This was confirmed in a larger dataset comprising 5,221 coronary procedures. Conclusions LDS was safer for patients reducing DAP and AK compared to SDS. However, occupational doses were not lower and scatter dose higher. Radiological protection measures must be kept maximized even in LDS.
Objective: The International Commission on Radiological Protection (ICRP) has highlighted the large number of medical specialties using fluoroscopy outside imaging departments without programmes of radiation protection (RP) for patients and staff. Vascular surgery is one of these specialties and endovascular aneurysm repair (EVAR) is one of the most challenging procedures requiring RP guidance and optimisation actions. The recent European Directive on Basic Safety Standards requires the use and regular update of diagnostic reference levels (DRL) for interventional procedures. The objective of the study was to know the doses of patients undergoing EVAR with mobile Xray systems and with hybrid rooms (fixed Xray systems), to obtain national DRLs and suggest optimisation actions. Methods: The Spanish Chapter of Endovascular Surgery launched a national survey that involved hospitals for 10 autonomous communities representing the 77% of the Spanish population (46.7 million inhabitants). Patient dose values from mobile Xray systems were available from nine hospitals (sample of 165 EVAR procedures) and data from hybrid rooms, from seven hospitals, with dosimetric data from 123 procedures. The initial national DRLs have been obtained, as the third quartile of the median values from the different centres involved in the survey. Results: The proposed national DRLs are 278 Gy cm(2) for hybrid rooms and 87 Gy cm(2) for mobile Xray systems, and for cumulative air kerma (cumulative AK) at the patient entrance reference point, 1403 mGy for hybrid rooms, and 292 mGy for mobile systems. Conclusion: An audit of patient doses for EVAR procedures to identify optimised imaging protocol strategies is needed. It is also appropriate to evaluate the diagnostic information required for EVAR procedures. The increase by a factor of 3.2 (for kerma area product) and 4.8 (for cumulative AK) in the DRLs needs to be justified when the procedures are performed in the hybrid rooms rather than with mobile Xray systems.
The aim of this study is to propose national diagnostic reference levels (DRL) for updating in the field of interventional cardiology and to include technical details to help plan optimization.Medical physics experts and interventional cardiologists from 14 hospitals provided patient dose indicators from coronary angiography and percutaneous coronary interventions. Information about X-ray system dose settings and image quality was also provided.The dose values from 30,024 procedures and 26 interventional laboratories were recorded. The national DRLs proposed for coronary angiography and percutaneous coronary interventions were respectively 39 and 78 Gy·cm2 for air kerma area product (PKA), 530 and 1300 mGy for air kerma at reference point (Ka,r), 6.7 and 15 min of fluoroscopy time and 760 and 1300 cine images. 36% of the KAP meters required correction factors from 10 to 35%. The dose management systems should allow these corrections to be included automatically. The dose per image in cine in reference conditions differed in a factor of 5.5.Including X-ray system dose settings in the methodology provides an insight into the differences between hospitals. The DRLs proposed for Spain in this work were similar to those proposed in the last European survey. The poor correlation between X-ray systems dose settings and patient dose indicators highlights that other factors such as operation protocols and complexity may have more impact in patient dose indicators, which allows a wide margin for optimization. Dose reduction technology together with appropriate training programs will be determinant in the future reduction of patient dose indicators.
During transcatheter aortic valve implantations (TAVI) and other percutaneous structural procedures, some patients may need close anesthesiological care, thus exposing the anaesthesiologist to x-rays. This work aims to investigate the radiation dose received by anaesthesiologists during these specific procedures in order to improve their radiological protection. Occupational radiation doses were measured prospectively during percutaneous structural procedures in several health professionals using electronic dosimeters worn over the apron at chest level. A sample of 49 procedures were recorded, where the anaesthesiologists' average dose per procedure resulted 13 times higher than that of interventional cardiologists. The average dose per procedure received over the protection apron during TAVIs by the anaesthesiologist was 0.13 mSv, with a maximum value of 0.69 mSv. Taking these figures as a conservative estimation of the eye lens dose, an anaesthesiologist could participate in around 150 procedures before reaching the regulatory annual dose limit for the lens of the eye in Europe (20 mSv). In those clinical procedures where patients need close anesthesiological care, the anaesthesiologists might receive high radiation doses increasing the risk for cataracts and the risk of stochastic radiation effects. The proper use of occupational dosimeters will help identify these situations. It is recommended to use a mobile shielding barrier to reduce radiation exposure to acceptable levels in these situations.