Abstract Background Automated radiotherapy treatment planning has benefited from data‐driven approaches; however, achieving consistently high plan quality across patients remains challenging. Dose prediction models provide patient‐specific priors but lack adaptive optimization, whereas large language models (LLMs) offer strong reasoning capabilities but raise concerns regarding stability and safety in clinical use. Purpose To develop and validate a fully automated VMAT treatment planning framework integrating dose prediction and LLM‐driven dynamic optimization, termed the Virtual physicist (VP), and to evaluate its dosimetric performance, plan complexity, and consistency relative to manual and other automated planning strategies. Methods A total of 70 cervical cancer patients previously treated with VMAT were retrospectively collected. The dataset was divided into 50 cases for training, 10 for validation, and 10 for testing. The input data consisted of patients’ planning CT images with contoured planning target volumes (PTVs) and organs at risk (OARs). The outputs included predicted three‐dimensional dose distributions (upper‐, middle‐, and lower‐dose bands) and automatically generated VMAT treatment plans with corresponding dosimetric and plan complexity metrics. The VP framework was implemented in the MOZI treatment planning system via a Python scripting interface. A dose‐band prediction model was used to initialize patient‐specific optimization constraints. During optimization, an LLM iteratively adjusted objectives and weights based on real‐time dosimetric feedback, subject to a rule‐based safety engine enforcing clinical and physical constraints. Plans generated using dose prediction only (DP‐only), LLM only (LLM‐only), and combined dose prediction with LLM (DP + LLM) were compared with clinically delivered manual plans. Results The DP + LLM strategy significantly improved sparing of the bladder and bilateral femoral heads compared with all three other strategies and significantly reduced rectal doses relative to the DP‐only and manual plans ( P < 0.05), while maintaining PTV Dmean, HI, CI, and GI comparable to those of the manual plans ( P > 0.05). For dual‐layer MLC plan complexity, DP + LLM produced a more balanced modulation pattern than manual planning, with lower distal‐layer complexity—significant for d‐C/A and d‐MCS but not d‐BA—and higher proximal‐layer complexity across all three metrics. Compared with DP‐only and LLM‐only plans, DP + LLM showed a consistent trend toward greater complexity in most metrics, with significant differences in several metrics. In addition, the automated strategies generally showed smaller standard deviations in complexity metrics, indicating improved planning consistency. Conclusion Integrating dose prediction with LLM‐driven dynamic optimization enables a robust and fully automated planning workflow, improving OAR sparing and planning consistency without compromising target dose quality, and demonstrates strong potential for clinically applicable intelligent radiotherapy planning.
ABSTRACT Background Diabetes is associated with structural and functional differences in plantar soft tissues, which may be reflected in ultrasound texture patterns. However, existing ultrasound texture studies are limited by single‐scale feature extraction and limited feature‐level interpretability. Purpose To develop an explainable machine learning framework incorporating a wavelet‐enhanced multi‐scale texture feature extraction module (WEMS‐TFE), and to investigate whether heel pad ultrasound texture features differ between patients with diabetes without active foot ulcers and healthy controls. Methods Heel pad ultrasonography was performed in 76 patients with diabetes (without active foot ulcers) and 47 healthy controls. Ultrasound images of the heel pad were analyzed at the microchamber and macrochamber levels. The WEMS‐TFE module was proposed to extract multi‐scale, multi‐directional texture features via two‐dimensional discrete wavelet decomposition combined with the gray‐level co‐occurrence matrix (GLCM). Features with significant between‐group differences were selected and evaluated across seven machine learning classifiers using repeated cross‐validation with participant‐disjoint data partitions. SHapley Additive exPlanations (SHAP) analysis was used to interpret feature contributions in a representative XGBoost model. Results The WEMS‐TFE scheme achieved the highest cross‐model composite performance and robustness among the five evaluated feature extraction schemes. Cross‐classifier importance analysis identified 6 features that recurred across multiple classifiers. Consistently, most of these also ranked among the important features in the XGBoost SHAP analysis, and two representative features showed clear value‐dependent contribution patterns. The identified features therefore reflected group‐associated image‐texture differences, although their associations may be affected by residual demographic confounding. Conclusions The proposed framework, with the WEMS‐TFE module as its core component, enables quantitative characterization of group‐associated differences in heel pad ultrasound texture features. The findings provide imaging‐based evidence of group‐level texture differences in the heel pad and support further investigation of plantar tissue characteristics in diabetes, while acknowledging that these differences may be affected by residual demographic confounding and do not establish diabetes‐specific structural changes or causal tissue mechanisms.
Abstract Background Online adaptive radiotherapy (oART) accounts for anatomical changes by adjusting treatment plans on a daily basis. However, comprehensive plan‐specific quality assurance (QA) is challenging, as pre‐treatment measurements cannot be performed with the patient on the treatment couch. Therefore, an end‐to‐end QA approach, covering imaging, contouring, plan adaptation, dose calculation, and delivery, is essential to ensure accurate and reliable oART. Purpose To develop and evaluate an end‐to‐end QA workflow for oART, incorporating high‐resolution detector‐based 2D dose verification and interchangeable phantom inserts. Methods A novel QA workflow was implemented using the myQA® SRS phantom with a 2D CMOS detector and a 3D‐printed anthropomorphic pelvis insert. A virtually deformed planning CT was generated to simulate anatomical changes and used as input for the adaptive workflow. The process included CBCT acquisition, manual contour adaptation, plan generation, dose delivery, and comparison of measured and calculated dose distributions via Gamma Analysis. Workflow feasibility was tested through repeated measurements. Error detectability was evaluated by altering gantry/collimator angles, monitor units (MU), phantom positioning, and CBCT presets. Confidence limits, calculated following AAPM TG‐119 methodology, were used as plan‐specific thresholds for evaluating Gamma Pass Rates (GPR). Corresponding dose‐volume histogram (DVH) parameters, using D98% for the planning target volume (PTV) and V95% for organs at risk (OARs), were calculated. Results Ethos auto‐contouring did not perform reliably on the phantom geometry, necessitating manual contouring. All workflow repetitions produced high GPR values for 3 %/2 mm, 2 %/2 mm, 3 %/1 mm, and 2 %/1 mm global criteria between measured and calculated dose. Confidence limits served as effective thresholds for identifying plan deviations. Introduced errors, including gantry angle deviations > 3° and collimator angle deviations ≥ 3°, MU variations ≥ 3 %, incorrect CBCT presets, and 3 mm setup shifts, were clearly detectable across all criteria. Smaller deviations, such as 1° angular changes or 1 % MU variation, resulting in minor dosimetric effects residing at or below 1.2 % for the PTV and 5.6 % for OARs, yielded GPR values above the Confidence limit. Conclusions The proposed workflow is feasible, reproducible, and capable of reliably identifying plan‐specific deviations in Ethos oART. High‐resolution 2D measurements and dose comparison provided robust verification of adaptive dose calculation and delivery. While limited by manual contouring and data‐handling constraints inherent to the Ethos platform, this method represents a practical end‐to‐end QA approach for clinical oART implementation.
Abstract Purpose This study compares stereotactic radiosurgery (SRS) treatment plan quality between the recently launched ZAP‐Axon ® Krylov optimizer and the Leksell Gamma Knife ® (LGK) Lightning optimizer for brain metastasis (BM). Methods Thirty ( n = 30) patients who were previously treated with LGK SRS or fractionated SRS were selected and divided into three groups: large post‐operative resection cavities of BM (BM lg, postop ), large intact BM (BM lg, intact ) and small intact BM (BM sm, intact ). Based on our institutional planning guidelines, the 30 clinical cases were replanned using ZAP‐Axon Krylov and LGK Lightning optimizers without manual adjustments. Statistical analysis was performed to compare plan quality metrics (Paddick conformity index [PCI], gradient index [GI], target coverage [TC], prescribed isodose line [Rx IDL], and treatment time/scaled beam‐on‐time [sBOT] [min]) between the two optimizers. Results For the BM lg, postop group, mean values of PCI, GI, TC, Rx IDL, and treatment time/sBOT (min) for Krylov versus Lightning plans were 0.91 versus 0.91, 2.48 versus 2.56, 99.5% versus 99.7%, 51.1% versus 53.7% and 37.4 min versus 36.5 min, respectively. All metrics except for the Rx IDL (%) were not statistically significantly different. For the BM lg, intact group, corresponding values were 0.93 versus 0.93, 2.42 versus 2.57, 99.5% versus 99.7%. 51.5% versus 53.0% and 35.9 min versus 36.3 min. While GI was statistically significantly different ( p <0.05) between the two optimizers, the rest of the metrics were not. For the BM sm, intact group, corresponding values were 0.71 versus 0.64, 3.10 versus 3.26, 99.5% versus 99.5%, 61.9% versus 53.0% and 8.1 min versus 19.8 min. In this group, PCI and treatment time/sBOT were statistically significantly different ( p <0.05), whereas GI and Rx IDL were not. Conclusion Without manual adjustments, ZAP‐Axon Krylov plans were comparable to LGK Lightning plans for large BM lesions, but the Krylov optimizer outperformed the Lightning optimizer for small BM lesions.
Abstract Carbon ion radiotherapy (CIRT) has evolved into an established clinical modality over the past three decades. Owing to its unique physical and biological characteristics, CIRT has demonstrated favorable outcomes for selected malignancies characterized by radioresistance, proximity to critical organs, locally advanced disease requiring safe dose escalation, and recurrent tumors requiring re‐irradiation. This review summarizes the physical and radiobiological rationale for CIRT, the evolution of international clinical practice and the clinical relative biological effectiveness models and dose prescription systems currently used in Asia and Europe. We discuss the differences between the modified microdosimetric kinetic model and Local Effect Model frameworks and their implications for interpreting and applying international clinical experience. We also describe the biological dose calculation framework adopted by Mayo Clinic Florida (MCF) to integrate established international CIRT experience into the first U.S. program. Published estimates of CIRT eligibility and need in the United States are reviewed to provide context for the anticipated U.S. patient population. This population includes many clinically complex disease sites characterized by proximity to critical organs, respiratory motion, anatomical variation, and the potential need for adaptive treatment. These clinical characteristics define important requirements for the first U.S. CIRT program and provide the foundation for the design philosophy and technical implementation described in the companion Part II article.