The first commercially available whole-body photon-counting CT (PCCT) system, cleared by the Food and Drug Administration in 2021, has since been adopted across an expanding range of clinical practice settings. This review article focuses on the clinical applications of PCCT, drawing insights from a carefully selected subset of the most relevant studies among 458 identified peer-reviewed publications (mean journal impact factor: 8.5). It explores the growing use of PCCT across major imaging domains, including cardiac, thoracic, neurovascular, musculoskeletal, abdominal, and pediatric imaging. The article highlights how the core technical innovations of PCCT, including improved spatial and contrast resolution, spectral capabilities, reduced electronic noise, and enhanced dose efficiency, have translated into tangible clinical benefits such as superior image quality, improved diagnostic performance, and reduced radiation dose. This article presents the collective findings within the context of broader clinical adoption. It also covers protocol optimization and emerging evidence on disease management and cost-effectiveness, as well as current workflow challenges. It highlights the progress made in the clinical adoption of PCCT and the remaining evidence gaps, particularly the need for protocol standardization to enable large-scale multicenter studies. © The Author(s) 2026. Published by the Radiological Society of North America under a CC BY 4.0 license. Supplemental material is available for this article.
CMS has adopted a new CT quality measure seeking to discourage excessive radiation dose while preserving image quality. The measure score is expressed as the percentage of qualifying studies that exceed predetermined thresholds, indicating inadequate image quality (based on image noise) or excessive radiation dose. The measure has been incorporated into the major CMS quality-based payment programs, impacting hospitals and clinician payments; measure reporting began in January 2025. After measure development, practitioners identified a spectrum of concerns and impediments, prompting the American Association of Physicists in Medicine to convene a multidisciplinary expert panel to provide further guidance. The panel identified 20 issues and ambiguities in the measure specifications, stemming from metrology concerns, unconventional terminology, and inconsistencies with practice standards or norms; these issues relate to themes of applicability, categories and metrics, informatics, performance expectations, and meta considerations. In this article, the panel presents these issues and ambiguities with associated recommendations to promote the measure's intentions. These recommendations include greater data access (e.g., to the measure's source data and to reporting elements for audit support) and a more holistic treatment of image quality. The panel ultimately urges a shift toward open-source, open-access, consensus-based, and community-owned strategies to ensure CT quality and safety.
Aims:Ejection fraction (EF) and end-systolic volume (ESV) are prognostic markers in cardiovascular disease. While MRI provides accurate assessments, its cost limits widespread use. Non-contrast cardiac CT (NCCT), used for coronary artery disease screening, may offer additional functional information. To evaluate the accuracy of AI-derived ventricular volumes and EF from NCCT compared with contrast cardiac CT (CCT) and MRI. Methods and results:This single center study included 205 patients who underwent cardiac CT for valve planning, divided into retrospective and prospective cohorts. A validated AI algorithm was applied to low-dose NCCT images at end-diastole and end-systole. Right (RV) and left ventricles (LV) volumes and their EFs were compared with CCT and MRI. In the prospective cohort (49 women, 53 men; mean age 73.9 ± 10.3 years), NCCT correlated strongly with CCT for LVEDV (152 mL; -14.2% relative difference; r = 0.91) and LVESV (96 mL; +32.6%; r = 0.84), with similar correlations for RVEDV (163 mL; -8.4%; r = 0.82) and RVESV (121.4 mL; +33.1%; r = 0.85). NCCT predicted LVEF <40% with 98% negative predictive value and 87% accuracy. LVEDV correlated strongly with MRI (n = 16) for CCT (240 mL; +4.2%; r = 0.99) and NCCT (197 mL; -14.3%; r = 0.97), as did LVESV for CCT (115 mL; -5%; r = 0.99) and NCCT (134 mL; +11%; r = 0.97). Conclusion:AI-derived ventricular volumes from NCCT show moderate to strong correlations, but EF is underestimated. The derived EF can be a screening tool to rule out significant ventricular dysfunction.
OBJECTIVE:Different methods can be used to condition imaging systems for clinical use. The purpose of this study was to assess how these methods complement one another in evaluating a system for clinical integration of an emerging technology, photon-counting computed tomography (PCCT), for thoracic imaging. METHODS:Four methods were used to assess a clinical PCCT system (NAEOTOM Alpha; Siemens Healthineers, Forchheim, Germany) across 3 reconstruction kernels (Br40f, Br48f, and Br56f). First, a phantom evaluation was performed using a computed tomography quality control phantom to characterize noise magnitude, spatial resolution, and detectability. Second, clinical images acquired using conventional and PCCT systems were used for a multi-institutional reader study where readers from 2 institutions were asked to rank their preference of images. Third, the clinical images were assessed in terms of in vivo image quality characterization of global noise index and detectability. Fourth, a virtual imaging trial was conducted using a validated simulation platform (DukeSim) that models PCCT and a virtual patient model (XCAT) with embedded lung lesions imaged under differing conditions of respiratory phase and positional displacement. Using known ground truth of the patient model, images were evaluated for quantitative biomarkers of lung intensity histograms and lesion morphology metrics. RESULTS:For the physical phantom study, the Br56f kernel was shown to have the highest resolution despite having the highest noise and lowest detectability. Readers across both institutions preferred the Br56f kernel (71% first rank) with a high interclass correlation (0.990). In vivo assessments found superior detectability for PCCT compared with conventional computed tomography but higher noise and reduced detectability with increased kernel sharpness. For the virtual imaging trial, Br40f was shown to have the best performance for histogram measures, whereas Br56f was shown to have the most precise and accurate morphology metrics. CONCLUSION:The 4 evaluation methods each have their strengths and limitations and bring complementary insight to the evaluation of PCCT. Although no method offers a complete answer, concordant findings between methods offer affirmatory confidence in a decision, whereas discordant ones offer insight for added perspective. Aggregating our findings, we concluded the Br56f kernel best for high-resolution tasks and Br40f for contrast-dependent tasks.
Multi-energy computed tomography (MECT) offers the opportunity for advanced visualization, detection, and quantification of select elements (e.g., iodine) or materials (e.g., fat) beyond the capability of standard single-energy computed tomography (CT). However, the use of MECT requires careful consideration as substantially different hardware and software approaches have been used by manufacturers, including different sets of user-selected or hidden parameters that affect the performance and radiation dose of MECT. Another important consideration when designing MECT protocols is appreciation of the specific tasks being performed; for instance, differentiating between two different materials or quantifying a specific element. For a given task, it is imperative to consider both the radiation dose and task-specific image quality requirements. Development of a quality control (QC) program is essential to ensure the accuracy and reproducibility of these MECT applications. Although standard QC procedures have been well established for conventional single-energy CT, the substantial differences between single-energy CT and MECT in terms of system implementations, imaging protocols, and clinical tasks warrant QC tests specific to MECT. This task group was therefore charged with developing a systematic QC program designed to meet the needs of MECT applications. In this report, we review the various MECT approaches that are commercially available, including information about hardware implementation, MECT image types, image reconstruction, and postprocessing techniques that are unique to MECT. We address the requirements for MECT phantoms, review representative commercial MECT phantoms, and offer guidance regarding homemade MECT phantoms. We discuss the development of MECT protocols, which must be designed carefully with proper consideration of MECT technology, imaging task, and radiation dose. We then outline specific recommended QC tests in terms of general image quality, radiation dose, differentiation and quantification tasks, and diagnostic and therapeutic applications.
Purpose To investigate the ability of kilovolt-independent (hereafter, kV-independent) and tin filter spectral shaping to accurately quantify the coronary artery calcium score (CACS) and radiation dose reductions compared with the standard 120-kV CT protocol. Materials and Methods This prospective, blinded reader study included 201 participants (mean age, 60 years ± 9.8 [SD]; 119 female, 82 male) who underwent standard 120-kV CT and additional kV-independent and tin filter research CT scans from October 2020 to July 2021. Scans were reconstructed using a Qr36f kernel for standard scans and an Sa36f kernel for research scans simulating artificial 120-kV images. CACS, risk categorization, and radiation doses were compared by analyzing data with analysis of variance, Kruskal-Wallis test, Mann-Whitney test, Bland-Altman analysis, Pearson correlations, and κ analysis for agreement. Results There was no evidence of differences in CACS across standard 120-kV, kV-independent, and tin filter scans, with median CACS values of 1 (IQR, 0-48), 0.6 (IQR, 0-58), and 0 (IQR, 0-51), respectively (P = .85). Compared with standard 120-kV scans, kV-independent and tin filter scans showed excellent correlation in CACS values (r = 0.993 and r = 0.999, respectively), with high agreement in CACS risk categorization (κ = 0.95 and κ = 0.93, respectively). Standard 120-kV scans had a mean radiation dose of 2.09 mSv ± 0.84, while kV-independent and tin filter scans reduced it to 1.21 mSv ± 0.85 and 0.26 mSv ± 0.11, cutting doses by 42% and 87%, respectively (P < .001). Conclusion The kV-independent and tin filter research CT acquisition techniques showed excellent agreement and high accuracy in CACS estimation compared with standard 120-kV scans, with large reductions in radiation dose. Keywords: CT, Cardiac, Coronary Arteries, Radiation Safety, Coronary Artery Calcium Score, Radiation Dose Reduction, Low-Dose CT Scan, Tin Filter, kV-Independent Supplemental material is available for this article. © RSNA, 2024.
Performing CT in children comes with unique challenges such as greater degrees of patient motion, smaller and densely packed anatomy, and potential risks of radiation exposure. The technical advancements of photon-counting detector (PCD) CT enable decreased radiation dose and noise, as well as increased spatial and contrast resolution across all ages, compared with conventional energy-integrating detector CT. It is therefore valuable to review the relevant technical aspects and principles specific to protocol development on the new PCD CT platform to realize the potential benefits for this population. The purpose of this article, based on multi-institutional clinical and research experience from pediatric radiologists and medical physicists, is to provide protocol guidance for use of PCD CT in the imaging of pediatric patients.
Photon-counting detector computed tomography (PCD-CT) is the most recent advancement in CT technology and has the potential to change clinical practice. Unlike conventional energy-integrated-detector (EID) that uses a two-step process to convert X-rays into a digital signal, PCD-CT directly converts photon energies into electronic signal. The advantages of PCD-CT over EID-CT are higher spatial resolution, electronic noise reduction, higher contrast-to-noise ratio, improved radiation dose efficiency, and intrinsic spectral imaging. Successful implementation into clinical practice requires adaptations in CT protocols. In this review, we summarize the basic principles of PCD-CT and technical scanning factors followed by a discussion of its clinical benefits in pediatric pulmonary and cardiovascular imaging.
Photon counting CT was recently introduced into clinical practice [Rajendran K, Petersilka M, Henning A, Shanblatt ER, Schmidt B, Flohr TG, Ferrero A, Baffour F, Diehn FE, Yu L, Rajiah P, Fletcher JG, Leng S, McCollough CH. First Clinical Photon-counting Detector CT System: Technical Evaluation. Radiology 2022;303(1):130-138. doi: https://doi.org/10.1148/radiol.212579 ]. Photon counting detectors (PCD) afford better spatial resolution, radiation dose efficiency, and iodine contrast-to-noise than EID-CT [Leng S, Bruesewitz M, Tao S, Rajendran K, Halaweish AF, Campeau NG, Fletcher JG, McCollough CH. Photon-counting Detector CT: System Design and Clinical Applications of an Emerging Technology. Radiographics 2019;39(3):729-743. doi: https://doi.org/10.1148/rg.2019180115 ); (Leng S, Rajendran K, Gong H, Zhou W, Halaweish AF, Henning A, Kappler S, Baer M, Fletcher JG, McCollough CH. 150-mum Spatial Resolution Using Photon-Counting Detector Computed Tomography Technology: Technical Performance and First Patient Images. Invest Radiol 2018;53(11):655-662. doi: https://doi.org/10.1097/RLI.0000000000000488 )(Booij R, van der Werf NR, Dijkshoorn ML, van der Lugt A, van Straten M. Assessment of Iodine Contrast-To-Noise Ratio in Virtual Monoenergetic Images Reconstructed from Dual-Source Energy-Integrating CT and Photon-Counting CT Data. Diagnostics (Basel) 2022;12(6). doi: https://doi.org/10.3390/diagnostics12061467 ); (Sawall S, Klein L, Amato C, Wehrse E, Dorn S, Maier J, Heinze S, Schlemmer HP, Ziener CH, Uhrig M, Kachelriess M. Iodine contrast-to-noise ratio improvement at unit dose and contrast media volume reduction in whole-body photon-counting CT. Eur J Radiol 2020;126:108909. doi: https://doi.org/10.1016/j.ejrad.2020.108909 ] while also maintaining multienergy CT (MECT) capabilities[Flohr T, Petersilka M, Henning A, Ulzheimer S, Ferda J, Schmidt B. Photon-counting CT review. Phys Med 2020;79:126-136. doi: https://doi.org/10.1016/j.ejmp.2020.10.030 ]. This article will review the clinical adoption of PCD-CT including protocol development, clinical applications, clinical integration and workflow considerations. Protocol development is institution specific and involves collaborative decision-making among radiologists, physicists, and technologists. Key PCD clinical applications include radiation exposure reduction, intravenous contrast volume reduction, and improved lesion conspicuity. Patients who would most benefit from these improvements may preferentially be scanned with PCD CT. With numerous available reconstructions, radiologists should be strategic in the series sent to PACS for interpretation and routinely sending spectral series to PACS can facilitate integration with clinical workflow. The Society of Abdominal Radiology PCD Emerging Technology Commission endorsed this article.
Accurate quantification of lung density, in Hounsfield Units (HU), is of high importance to monitor progression of diseases such as emphysema using chest CT imaging. Reproducibility of HU quantification on independent photon counting detector CT (PCD-CT) systems with a focus on lung imaging have not yet been evaluated. We thus aimed to evaluate HU reproducibility on 2 independent PCD-CT systems using a repeatable phantom setup with identical acquisition and image reconstruction settings. A COPDGene phantom comprising densities of air, water and lung was scanned on 2 independent PCCT systems using 3 different radiation exposures, 2 medium-sharpness reconstruction kernels (Br40 and Qr36), with and without iterative reconstruction (levels 0 vs 3). Our results demonstrate that acquisitions performed with full dose (3.2 mGy), half dose (1.6 mGy), and one-eighth dose (0.4 mGy) had minimal influence on HU accuracy (<6 HU) when using Br40 and Qr36 kernels. The level of iterative reconstruction also has a minimal impact (<6 HU) with the same kernels. Between the 2 PCD-CT systems evaluated, reproducible HU quantification was achieved for changes to CTDIvol, iterative reconstruction level and reconstruction kernel.
Photon-counting detector CT (PCD-CT) is a new technology that has multiple diagnostic benefits including increased spatial resolution, iodine signal, and radiation dose efficiency, as well as multi-energy imaging capability, but which also has unique challenges in abdominal imaging. The purpose of this work is to summarize key features, technical parameters, and terms, which are common amongst current abdominopelvic PCD-CT systems and to propose standardized terminology (where none exists). In addition, user-selectable protocol parameters are highlighted to facilitate both scientific evaluation and early clinical adoption. Unique features of PCD-CT systems include photon-counting detectors themselves, energy thresholds and bins, and tube potential considerations for preserved spectral separation. Key parameters for describing different PCD-CT systems are reviewed and explained. While PCD-CT can generate multi-energy images like dual-energy CT, there are new types of images such as threshold images, energy bin images, and special spectral images. The standardized terms and concepts herein build upon prior interdisciplinary consensus and have been endorsed by the newly created Society of Abdominal Radiology Photon-counting CT Emerging Technology Commission.
To determine whether image reconstruction with a higher matrix size improves image quality for lower extremity CTA studies. Raw data from 50 consecutive lower extremity CTA studies acquired on two MDCT scanners (SOMATOM Flash, Force) in patients evaluated for peripheral arterial disease (PAD) were retrospectively collected and reconstructed with standard (512 × 512) and higher resolution (768 × 768, 1024 × 1024) matrix sizes. Five blinded readers reviewed representative transverse images in randomized order (150 total). Readers graded image quality (0 (worst)–100 (best)) for vascular wall definition, image noise, and confidence in stenosis grading. Ten patients’ stenosis scores on CTA images were compared to invasive angiography. Scores were compared using mixed effects linear regression. Reconstructions with 1024 × 1024 matrix were ranked significantly better for wall definition (mean score 72, 95
PURPOSE:To compare liver fat quantification between MRI and photon-counting CT (PCCT). METHOD:A cylindrical phantom with inserts containing six concentrations of oil (0, 10, 20, 30, 50 and 100%) and oil-iodine mixtures (0, 10, 20, 30 and 50% fat +3 mg/mL iodine) was imaged with a PCCT (NAEOTOM Alpha) and a 1.5 T MRI system (MR 450w, IDEAL-IQ sequence), using clinical parameters. An IRB-approved prospective clinical evaluation included 12 obese adult patients with known fatty liver disease (seven women, mean age: 61.5 ± 13 years, mean BMI: 30.3 ± 4.7 kg/m2). Patients underwent a same-day clinical MRI and PCCT of the abdomen. Liver fat fractions were calculated for four segments (I, II, IVa and VII) using in- and opposed-phase on MRI ((Meanin - Meanopp)/2*Meanin) and iodine-fat, tissue decomposition analysis in PCCT (Syngo.Via VB60A). CT and MRI Fat fractions were compared using two-sample t-tests with equal variance. Statistical analysis was performed using RStudio (Version1.4.1717). RESULTS:Phantom results showed no significant differences between the known fat fractions (P = 0.32) or iodine (P = 0.6) in comparison to PCCT-measured concentrations, and no statistically significant difference between known and MRI-measured fat fractions (P = 0.363). In patients, the mean fat signal fraction measured on MRI and PCCT was 13.1 ± 9.9% and 12.0 ± 9.0%, respectively, with an average difference of 1.1 ± 1.9% between the modalities (P = 0.138). CONCLUSION:First experience shows promising accuracy of liver fat fraction quantification for PCCT in obese patients. This method may improve opportunistic screening for CT in the future.
BACKGROUND. Photon-counting detector (PCD) CT has been shown to reduce radiation dose and improve image quality in adult chest CT examinations; its potential impact in pediatric CT is not well documented. OBJECTIVE. The purpose of our study was to compare radiation dose, objective image quality, and subjective image quality of PCD CT and energy-integrating detector (EID) CT in children undergoing high-resolution CT (HRCT) of the chest. METHODS. This retrospective study included 27 children (median age, 3.9 years; 10 girls, 17 boys) who underwent PCD CT between March 1, 2022, and August 31, 2022, and 27 children (median age, 4.0 years; 13 girls, 14 boys) who underwent EID CT between August 1, 2021, and January 31, 2022; all examinations comprised clinically indicated chest HRCT. The patients in the two groups were matched by age and water-equivalent diameter. Radiation dose parameters were recorded. One observer placed ROIs to measure objective parameters (lung attenuation, image noise, and SNR). Two radiologists independently assessed subjective measures (overall image quality and motion artifacts) using 5-point Likert scales (1 = highest quality). Groups were compared. RESULTS. PCD CT, in comparison with EID CT, showed lower median CTDIvol (0.41 vs 0.71 mGy, p < .001), DLP (10.2 vs 13.7 mGy × cm, p = .008), size-specific dose estimate (0.82 vs 1.34 mGy, p < .001), and tube current-exposure time product (48.0 vs 202.0 mAs, p < .001). PCD CT and EID CT showed no significant difference in right upper lobe (RUL) lung attenuation (mean, -793 vs -750 HU; p = .09), right lower lobe (RLL) lung attenuation (mean, -745 vs -716 HU; p = .23), RUL image noise (mean, 55 vs 51 HU; p = .27), RLL image noise (mean, 59 vs 57 HU; p = .48), RUL SNR (mean, -14.9 vs -15.8; p = .89), or RLL SNR (mean, -13.1 vs -13.6; p = .79). PCD CT and EID CT showed no significant difference in median overall image quality for reader 1 (1.0 vs 1.0, p = .28) or reader 2 (1.0 vs 1.0, p = .17) or median motion artifacts for reader 1 (1.0 vs 1.0, p = .07) or reader 2 (1.0 vs 1.0, p = .22). CONCLUSION. PCD CT showed significantly reduced dose levels without a significant difference in objective or subjective image quality compared with EID CT. CLINICAL IMPACT. These data expand understanding of the capabilities of PCD CT and support its routine use in children.
Background Management of large vessel occlusion (LVO) patients after thrombectomy is affected by the presence of intracranial hemorrhage (ICH) on post-procedure imaging. Differentiating contrast staining from hemorrhage on post-procedural imaging has been facilitated by dual-energy computed tomography (DECT), traditionally performed in dedicated computed tomography (CT) scanners with subsequent delays in treatment. We employed a novel method of DECT using the Siemens cone beam CT (DE-CBCT) in the angiography suite to evaluate for post-procedure ICH and contrast extravasation. Methods After endovascular treatment for LVO was performed and before the patient was removed from the operating table, DE-CBCT was performed using the Siemens Q-biplane system, with two separate 20-second CBCT scans at two energy levels: 70 keV (standard) and 125 keV with tin filtration (nonstandard). Post-procedurally, patients also underwent a standard DECT using Siemens SOMATOM Force CT scanner. Two independent reviewers blindly evaluated the DE-CBCT and DECT for hemorrhage and contrast extravasation. Results We successfully performed intra-procedural DE-CBCT in 10 subjects with no technical failure. The images were high-quality and subjectively useful to differentiate contrast from hemorrhage. The one hemorrhage seen on standard DECT was very small and clinically silent. The interrater reliability was 100% for both contrast and hemorrhage detection. Conclusion We demonstrate that intra-procedural DE-CBCT after thrombectomy is feasible and provides clinically meaningful images. There was close agreement between findings on DE-CBCT and standard DECT. Our findings suggest that DE-CBCT could be used in the future to improve stroke thrombectomy patient workflow and to more efficiently guide the postoperative management of these patients.
PURPOSE Better time-resolved imaging of stent grafts in the ascending aorta and arch accounting for cardiac motion is necessary to understand device-related complications and endoleaks. This report describes dynamic time-resolved computed tomographic angiography (d-CTA) and its combination with electrocardiography gating (d-gated CTA) to image stent grafts in the ascending aorta and to characterize endoleaks more clearly. DESCRIPTION d-CTA involves multiple scans acquired at different time points along the contrast enhancement curve. d-Gated CTA involves concomitant electrocardiography gating in a predefined cardiac phase minimizing motioninduced artifacts. EVALUATION This report illustrates the utility of d-CTA and d-gated CTA in 2 clinical cases. d-CTA demonstrated a type 1A endoleak in a patient with an aortic arch aneurysm treated with total arch debranching and a thoracic stent graft. dgated CTA demonstrated a type 1A endoleak in a patient with an ascending aortic pseudoaneurysm treated with aortic cuff placement. CONCLUSIONS Dynamic, cardiac-gated CTA enables time-resolved angiographic imaging of the ascending aorta and arch without any cardiac motion-related artifacts. Such advanced imaging techniques help with better characterization of endoleaks after stent graft deployment in the ascending aorta and arch. (C) 2022 by The Society of Thoracic Surgeons
Despite cognitive and physical declines, it has been suggested that older adults remain able to regulate their emotions effectively. However, whether this is true for all emotion regulation processes has not been established. We hypothesized that cognitive reappraisal, a form of emotion regulation requiring intact cognitive control ability, may be compromised in older age, and that this age difference would be mediated by reduced activation in prefrontal cortex (PFC). Sixteen younger and 15 older adults used gaze-directed reappraisal to increase and decrease emotion in response to unpleasant pictures. This was compared with simply viewing the pictures. Relative to younger adults, older adults were less successful using reappraisal to decrease unpleasant emotion but more successful using reappraisal to increase unpleasant emotion. They also exhibited reduced activation in dorsomedial and left ventrolateral prefrontal cortex. Importantly, activation in these regions differentially mediated the effect of age on emotion. This pattern confirms the importance of cognitive control in reappraising unpleasant situations and suggests that older age may (but does not always) confer effective emotion regulation.
Abstract: Prospective head-to-head comparison of coronary calcium scores between standard computed tomography (CT) and photon-counting CT show no significant differences, while photon-counting CT administers substantially lower radiation dose.