This study compared the shear bond strength (SBS) and micromorphology of composite resin to human dentin after pre-treatment with silica-modified aluminum oxide air abrasion. Forty-six molar teeth were treated with either Scotchbond Multi-Purpose (SCMP) or Clearfil SE Bond (CLSE) adhesive. Buccal surfaces were pre-treated with the CoJet air abrasion system (SB), and lingual surfaces were controls. The adhesion of light-cured resin composite to the treated dentin surface was evaluated with SBS. After debonding, substrate surfaces were examined with an optical microscope for failure analysis. In addition, 15 molar teeth were sectioned and randomly assigned to one of five groups, according to the dentin surface pre-treatment and adhesive type, and examined with high-vacuum scanning electron microscopy/energy dispersive X-rays (SEM/EDS). The type of adhesive had a significant effect on SBS (p = 0.000); CLSE had the highest values. SB did not affect SBS (p = 0.090). SEM/EDS revealed residual aluminum and/or silicon on all dentin surfaces after SB, except for the control. Treatment with 32% phosphoric acid in the SCMP adhesive decreased the amounts of aluminum and silicon compared to SB dentin only, whereas CLSE resulted in similar quantities of aluminum and silicon as air-abraded dentin. The results of this study indicate that CLSE might have a higher bond strength to dentin than SCMP. Pre-treatment with SB does not appear to affect bonding strength.
Journal of Dental EducationVolume 87, Issue 4 p. 427-428 ISSUE INFORMATIONFree Access Journal of Dental Education Volume 87 Number 4/April 2023 First published: 19 April 2023 https://doi.org/10.1002/jdd.12975AboutPDF ToolsRequest permissionExport citationAdd to favoritesTrack citation ShareShare Give accessShare full text accessShare full-text accessPlease review our Terms and Conditions of Use and check box below to share full-text version of article.I have read and accept the Wiley Online Library Terms and Conditions of UseShareable LinkUse the link below to share a full-text version of this article with your friends and colleagues. Learn more.Copy URL Share a linkShare onEmailFacebookTwitterLinkedInRedditWechat No abstract is available for this article. Volume87, Issue4April 2023Pages 427-428 RelatedInformation
INTRODUCTION This in vitro study aims to biomechanically evaluate the influence of medium contamination for example, saliva, blood, chlorhexidine (liquid and gel), and fluoride mouthwash on the biomechanical behavior of implant abutments' screws under static and dynamic loading. METHODS Forty five Ti6Al4V commercial dental implants and abutments were tested in this study. Two main mechanical tests were carried out in the selected media. The first, static, aimed to evaluate the torque loss after the first tightening. The second, dynamic, involved a random cyclic load range between 0 and 200 N to evaluate torque loss due to mastication. In addition, metallographic longitudinal and cross-sections of the abutment-implant apparatus were examined to evaluate the abutment screw-abutment-implant interface. RESULTS The static torque test showed that irrespective of the media, no statistical difference in static torque loss was found prior to dynamic loading. For the dynamic tests, torque-angle evolution analysis during tightening to 30 Ncm and after the spectrum loading, showed the same global mechanical behavior for all media, but the statistical analysis indicated a difference between the groups in reverse torque values (RTV) and in the torque loss due to dynamic loading. The medium groups CHX, CHX-gel, and Fluoride mouthwash, showed a meaningful torque loss due to loading, but the medium groups, control (no medium), blood and saliva showed an opposite trend and required a higher torque to open the abutment screws. The microstructural analysis revealed clear signs of cold-welding/galling, post-dynamic loading in these latter groups. CONCLUSIONS The presence of lubrication/contamination media (CHX mouthwash/CHX-gel/Fluoride mouthwash) reduces the preload generated due to tightening but prevents damage due to galling. The observed reduction of RTV clearly emphasizes the need for frequent abutment screw retightening for implant-supported prosthetic long-term stability.
To compare the three-dimensional accuracy of an open-tray and two snap on impression techniques (with and without connecting the plastic caps of the snap on impression transfers) in a full arch 6-implant model, a reference acrylic resin model of the maxilla with six implants was fabricated. Prominent geometrical triangles, in the palate area, served as reference points for a digital overlap between scans. Three impression transfer techniques were evaluated and compared: open-tray direct impression (DI), snap on impression (SpO), and connected snap on impression (SpOC). Polyether impression material was used to make 30 impressions (n = 10), and the master model and all casts were digitally scanned with a laboratory optical scanner. The obtained 3D data were converted and recorded as STL files, which were imported to a 3D inspection software program. Angular deviations (buccal, occlusal and interproximal planes) between the study casts and the reference model were measured. Data were analyzed using one-way analysis of variance (ANOVA) and Tukey post hoc test, with 0.05 used as the level of significance. The 3D angular deviations from the master model revealed no significant differences between the DI and SpO impression groups, but there were significant differences in the SpOC impression group, particularly in the buccal and occlusal planes. In all groups, the 3D angular deviation between the most distal scan abutments on each side of the model was significantly different from all other areas when compared to the master model. Within the limits of this study, it is possible to conclude that the indirect closed tray snap on impression technique with unconnected plastic caps exhibited the same three-dimensional accuracies as the direct open tray technique. The indirect closed tray snap on impression technique with connected plastic caps was less accurate than either the indirect closed tray snap on impression technique with unconnected plastic caps or the direct open tray technique. In the case of full arch implant supported prostheses, inaccuracies may be expected in the most distal implants for all the three impression techniques evaluated in this study. Further in vitro and in vivo research is required.
OBJECTIVESThe current study aimed to assess criteria validity and test-retest reliability of the modified O'Connor Tweezer Dexterity (O'Connor) and the Purdue Pegboard test (PPT) for use among dental students. Occupational therapists were asked to assess dentist-related skills due to the high percentage of students who failed the dental school exams that year. The O'Connor and the PPT are suitable for these purposes, they aim to evaluate fine motor skills requirements. The original tests were modified for use under indirect visualization conditions (through a mirror) to mimic the typical dentists' work environment.MATERIALS AND METHODSA total of 110 dentists were included in the present study (50 dentists for the O'Connor test and 60 for the PPT). Both tests were conducted twice. Initially, the original version of the tests was followed by the modified versions (through a mirror). For the test-retest reliability assessment, 21 participants (10 participants from the O'Connor group and 11 participants from the PPT group) repeated the evaluation within a 1-week interval using the same settings (original followed by modified versions).RESULTSBoth versions of the O'Connor tests were significantly correlated (r = 0.54, p < 0.01), as were the two PPT versions (r = 0.640, p < 0.01). Significantly test-retest reliability was found for both tests. The interclass correlation ranged between 0.883 and 0.997, p < 0.000.CONCLUSIONThe results confirmed our hypothesis, demonstrating a criteria validity and test-retest reliability assessment of the modified O'Connor and the modified PPT for assessing dentists.
The aim of this study was to assess retrospectively the survival and success rates of monolithic zirconia restorations supported by teeth and implants in bruxer versus non-bruxer patients. Methods: A total of 15 bruxer and 25 non-bruxer patients attended the recall appointment. The bruxer group (mean age of 61.2 ± 13.3 years and follow-up of 58.7 ± 16.8 months) were treated with 331 monolithic zirconia restorations, while the non-bruxer group, with a comparable mean age and follow-up time, were treated with 306 monolithic zirconia restorations. Clinical data were retrieved from the patients’ files. At the recall appointment, all supporting teeth and implants were examined for biological and technical complications, and the restorations were evaluated using modified California Dental Association (CDA) criteria. Data were statistically analyzed using survival analysis methods. A significance level of p < 0.05 was used. A total of 31 versus 27 biologic and technical complications were recorded in the bruxer and non-bruxer groups, respectively. No significant differences were found between the two groups regarding overall complications and survival rate. Regarding the type of complication, a significantly higher rate of veneered porcelain chipping (p = 0.045) was observed in the bruxer group. With regard to biological complications, the only complications that exhibited a borderline, although not significant, difference were three fractured teeth exclusively in the bruxer group (p = 0.051), which were replaced with implant-supported restorations. Within the limitations of this study, we conclude that there were no significant differences in the overall survival and success rates of the monolithic zirconia restorations in bruxer versus non-bruxer patients, although veneered zirconia restorations and single tooth abutments exhibited a higher rate of complications in the bruxer group.
Malpositioned and broken implants are usually fully osseointegrated; hence, their removal, especially from the lower arch, can be very challenging. Implant removal techniques include reverse torque and trephination. Trephination is an invasive technique that can jeopardize vital structures, cause mandibular fatigue fractures, or lead to osteomyelitis. In this study, we aimed to assess the relationship between trephination depth and implant stability by recording implant stability quotient (ISQ) readings at varying trephination depths in vitro. Materials and methods: Forty-eight implants were inserted into dense synthetic polyurethane foam blocks as artificial bone. Primary implant stability was measured with a Penguin resonance frequency analysis (RFA) device. Implants of two designs with a diameter of 3.75 mm and a length of 13 or 8 mm were inserted. Twenty-four internal hexagon (IH) (Seven®) and twenty-four conical connection (CC) implants (C1®; MIS® Implants, Ltd., Misgav, Israel) were used. The primary implant stability was measured with the RFA device. Trephination was performed, and implant stability was recorded at depths of 0, 3, and 6 mm for the 8 mm implants and 0, 3, 6, 8, 10, and 11.5 mm for the 13 mm implants. Results: Linear regression revealed a significant relation between the trephination depth and the ISQ (F (1, 213) = 1113.192, p < 0.001, adjusted r2 = 0.839). The trephination depth significantly predicted the ISQ (β = −5.337, p < 0.001), and the ISQ decreased by −5.33 as the trephination depth increased by 1 mm. Conclusion: Implant stability reduction as measured using an RFA device during trephination may be a valuable guide to achieving safe reverse torque for implant removal. Further studies are needed to evaluate these data in clinical settings.
Aims: To determine if restoration location and/or execution behavior force parameters have an influence on the mechanical properties of bulk-fill composite dental restorations. Methods: Pressure transducers were placed within each quadrant of dental mannequin jaws. Cylindrical molds were placed above the transducers and filled with two bulk-fill composite materials, Filtek and Tetric, by four experienced dentists. Each dentist prepared five specimens per quadrant and material. The total placement time, mean force, number of peak forces (above 25 N), and mean peak(s) force during placement were measured. Then, the stiffness and maximal compressive strength of the specimens were determined while loading the specimens up to failure using a universal loading machine. Results: Placement time was affected by jaw (p < 0.004) and side (p < 0.029), with the shortest time demonstrated for the left side of the mandible. Force exerted during restoration placement was not normally distributed without differences in location (jaw) or material. A higher application force was found on the right side (p < 0.01). The number of peak forces was affected by side (p < 0.03), with less peaks on the left side. No significant differences were found in compressive strength when correlated to restoration location, participant, or material (p = 0.431). The stiffness values of Filtek (3729 ± 228 N/mm) were found to be 15% higher than Tetric (3248 ± 227 N/mm) (p < 0.005). No correlations were found between the compressive strength or stiffness and the amount of force applied during placement. Conclusions: The individual restoration material placement parameters did influence practitioner performance; however, these differences did not affect the mechanical properties of the final restoration.
The aim of the current study was to evaluate the influence of hydrofluoric (HF) acid concentration and conditioning time on the shear bond strength (SBS) of dual cure resin cement to pressed lithium disilicate ceramic compared to treatment with an Etch and Prime self-etching glass-ceramic primer (EP). A total of 100 samples of pressed lithium disilicate (IPS e.max Press, Ivoclar Vivadent) were randomly divided into five groups (n = 20) according to surface treatment: two different concentrations of HF (5% or 9%), for different durations (20 or 90 s), or treatment with EP. Adhesion of light-cured resin cement to the treated surface was tested by the SBS test. The substrate surfaces of the specimen after failures were examined by SEM. Data were analyzed using Weibull distribution. The highest cumulative failure probability of 63.2% of the shear bond strength (η parameter) values was in the 9% HF −90 s group (17.71 MPa), while the lowest values were observed in the 5% HF −20 s group (7.94 MPa). SBS values were not affected significantly by the conditioning time (20 s or 90 s). However, compared to treatment with 5% HF, surface treatment with 9% HF showed a significantly higher η (MPa) as well as β (reliability parameter). Moreover, while compared to 9% HF for 20 s, EP treatment did not differ significantly in SBS values. Examination of the failure mode revealed a mixed mode of failure in all the groups. Within the limits of this study, it is possible to assume that IPS e.max Press surface treatment with 9% HF acid for only 20 s will provide a better bonding strength with resin cement than using 5% HF acid.
Introduction: During a basic prosthetics course, dental students train on plastic teeth for fixed partial dentures (FPD). The complexity of manual skill acquisition and the need for extra training led us to develop a portable tool for home training (PhantHome). The aim of the current study was to assess whether training using the portable tool improves students fine motor skill, spatial perception, and orientation and may predict success in preclinical prosthetics courses. Material and Methods: A total of 42 third year dental students were included in this study. A valid dexterity test (Grooved Pegboard test) and a manual test using the portable tool (PhantHome) were conducted in direct and indirect visions using a mirror at two time points: T0: beginning of study, and T1: after training for one month with the portable tool at home. The students’ manual grades in the portable tool, Grooved test, and final prosthetics course grades were compared. Results: The results showed that indirect tasks were significantly more difficult to perform than direct tasks for PhantHome and Grooved tests at T0 and T1 (p < 0.0005). After practicing with the portable PhantHome tool (T1), the students’ scores of in PhantHome and Grooved tests improved significantly (p < 0.04). A regression analysis showed that students’ motor tasks scored at T0 predicted phantom course success in 86.8% of cases (p = 0.005). Conclusion: There was a positive transfer in learning: PhantHome training led to improved performance on the Grooved tests without further training on these tests. Therefore, training in the PhantHome tool can significantly improve performance in the prosthodontics phantom course. The prediction model predicted success in a prosthodontics course with 86% accuracy.
Accurate assessment of dental student performance during preclinical operative mannequin courses is an essential milestone within the educational process. Training on novel, multicolored 3D-printed teeth resulted in higher performances of the students in comparison to training on standard, monochromatic plastic teeth. However, low reliability of students' grading using standard, monochromatic plastic teeth was reported. The aim of this study was to verify whether the use of 3D multicolored teeth can (1) provide better inter- and intra-examiner reliability, and (2) assess the effect of instructors' experience on their reliability. The novel tooth analogs consisted of digitally planned and 3D-printed plastic teeth containing green, yellow, and red stratifications according to increasing depths of preparation. Thirty-seven dental students performed three Class I preparations on the 3D-printed teeth, and these underwent blind evaluation by two examiners of varied experience at two timepoints. The data were compared with preparations done on conventional (monochromatic) plastic teeth. Results indicated excellent inter-examiner reliability on 3D-printed teeth (0.768 < ICC < 0.929), but only moderate reliability with conventional plastic teeth (0.314 < ICC < 0.672). The examiner having more experience was found to show higher intra-examiner reliability (ICC = 0.716 and 0.612 using 3D-printed teeth and conventional teeth, respectively) than the less experienced examiner (ICC = 0.481 and 0.095 using 3D-printed teeth and conventional teeth, respectively). The novel, multicolored 3D-printed teeth can provide more objective evaluation of cavity preparation compared with conventional plastic teeth.
To retrospectively assess implant and prosthesis survival and success and patient satisfaction in edentulous patients treated with soft-milled cobalt-chromium-ceramic full-arch screw-retained implant-supported prostheses (SCCSIPs) over a mean clinical follow-up period of 4 years. Twenty-one edentulous patients, aged 47–80 years, underwent restoration with 27 SCCSIPs (210 implants, 349 crown units). After definitive prosthesis insertion, patients participated in a yearly dental check-up recall program, including clinical and radiographic examinations. All supporting implants were examined for biological and technical complications, and the restorations were evaluated using modified California Dental Association (CDA) criteria. Life table and Kaplan–Meier survival analyses were performed. Patient satisfaction regarding chewing, esthetics, comfort, and phonetics was evaluated using a visual analog scale (VAS). After a mean of 4 years, two implants (3.8%) failed, with no effect on prosthesis survival. The cumulative survival rate was 98.6% and 100% for implants and prostheses, respectively. The most frequent minor biological complication was soft tissue recession (11%). Porcelain fracture was the only major technical complication (0.6% of crown units), while the only minor technical complication was porcelain chipping (4% of crown units), which required only polishing. Overall, 66.7% of the prostheses were free of technical complications. Patient satisfaction was high to very high. Less satisfaction was noted with comfort due to soft tissue recession and food impaction. Within the limitations of this study, we conclude that the survival and success rates of SCCSIPs in edentulous patients were excellent. SCCSIPs should be considered when planning metal-ceramic implant-supported restorations.
Although three-dimensional (3D) printing technology is increasingly used in dental education, its application regarding the provision of online visual augmented feedback has not been tested. Thus, this study aimed to: (1) develop two generations of multicolored 3D-printed teeth that provide visual augmented feedback for students conducting the cavity preparation process, (2) assess students' clinical performance after training on the 3D models, and (3) acquire student feedback. For the first-generation model, augmented feedback was obtained from five 3D-printed teeth models for five cavity preparation procedures. Each model comprised three layers printed in green, yellow, and red indicating whether preparation was acceptable, limited, or unacceptable, respectively. The study used a crossover design in which the experimental group trained on five multicolored models and 10 standard plastic teeth, and the control group trained on 15 standard plastic teeth. Students gave positive feedback of the methodology but complained about the printed material's hardness. Therefore, a second-generation model was developed: the model's occlusal plane was replaced with a harder printed acrylic material, and the experiment was repeated. During training, instructors provided external terminal feedback only for performance on standard plastic teeth. Manual grades for cavity preparations on standard plastic teeth were compared. No significant differences were found between the control and experimental groups in both generations' models. However, less instructor time was needed, and similar clinical results were obtained after training with both generations. Thus, multicolored 3D-printed teeth models promote self-learning during the process of acquiring manual skills and reduce student dependency on instructors.
The aim of this study was to evaluate the retentive strength of zirconium oxide (yttria-stabilized tetragonal zirconia polycrystals (Y-TZP)) crown-copings treated by combined mechanical and chemical treatments and cemented by four types of self-adhesive resin cements (SARCs) to human prepared teeth, before and after six months of aging in water and thermocycling. A total of 120 molar teeth were mounted, prepared using a standardized protocol and digitally scanned, and Y-TZP copings were produced. Teeth were randomly assigned to four SARC groups. Prior to cementation, the intaglio surfaces of all crowns were sandblasted and then coated with Z-Prime™ Plus (Bisco Dental, Schaumburg, IL, USA). Post cementation, each cement group was subdivided into aged and non-aged groups. After aging, the cemented assemblies were tested for retentive strength using a universal testing machine. Failure analysis was conducted by inspecting all matched debonded surfaces of the teeth and crowns at 3× magnification. Aging treatment did not affect the retentive strength of the Y-TZP crown-copings (p = 0.918). The interaction between cement and aging was statistically significant (p = 0.024). No significant differences in the retentive strengths between the different SARCs were observed pre-aging (p = 0.776), whereas post-aging, Panavia SA (PAN; Kuraray Dental Co Ltd., Osaka, Japan) showed significantly higher strength than RelyX U-200 (RU200; 3M ESPE, Seefeld, Germany). The predominant failure mode was adhesive between the cement and dentin, followed by mixed mode failure.
The rapid advancement of peptide- and amino-acid -based nanotechnology offers new approaches for the development of biomedical materials. The utilization of fluorenylmethyloxycarbonyl (Fmoc)-decorated self-assembling building blocks for antibacterial and anti-inflammatory purposes represents promising advancements in this field. Here, we present the antibacterial capabilities of the nanoassemblies formed by Fmoc-pentafluoro-L-phenylalanine-OH, their substantial effect on bacterial morphology, as well as new methods developed for the functional incorporation of these nanoassemblies within resin-based composites. These amalgamated materials inhibit and hinder bacterial growth and viability and are not cytotoxic toward mammalian cell lines. Importantly, due to the low dosage required to confer antibacterial activity, the integration of the nanoassemblies does not affect their mechanical and optical properties. This approach expands on the growing number of accounts on the intrinsic antibacterial capabilities of self-assembling building blocks and serves as a basis for further design and development of enhanced composite materials for biomedical applications.
OBJECTIVES:Traditionally, the acquisition of manual skills in most dental schools worldwide is based on exercises on plastic teeth placed in a "phantom head simulator". No manual trainings are done at home. Studies revealed that preliminary training of one motoric task leads to significant improvement in performance of the required motoric task that has similar components. Performing tasks indirectly via a dental mirror are complicated for the young dental students. We hypothesized that instructed training of basic skills required in dentistry at home on a tool simulating the phantom laboratory will improve the capabilities of the students and will be reflected by their clinical grades. METHODS:We developed a portable tool PhantHome which is composed of jaws, gingival tissue, rubber cover and a compatible stand. Specific teeth produced by a 3D printer with drills in different directions were placed in both jaws. Students were requested to insert pins by using tweezers and dental mirror according to instructions initiating with easy tasks and continue to ones that are more complicated. 106 first clinical year dental students participated in the study; 65 trained only in the traditional phantom lab (control). 41 trained at home by the PhantHome tool two weeks before and 2 months during the initial stage of phantom lab. The students grades routinely provided in the phantom laboratory at different stages were compared. RESULTS:Students who trained with the portable tool performed better than the control group in the first direct and second indirect preparations (p<0.05). These exams were taken when the PhantHome was available to the students. Then, the tool was returned and the phantom course continued regularly. We believe that this is why no differences between the grades of the groups were observed further on. CONCLUSIONS:Training by the PhantHome improves motor skills and consequently the clinical performances.
Purpose: To assess the clinical performance of the complete rehabilitation of a series of patients with bruxism treated by teeth- and implant-supported veneered and non-veneered zirconia restorations with an increased vertical dimension of occlusion (VDO). Methods: Ten patients with bruxism, aged 62-70 years, were treated with 108 veneered and 142 non-veneered zirconia restorations and attended the recall appointment. The mean observation period was 28.2 (+/- 16.8) months. The patients were identified from records, and clinical details were retrieved from their files. In the recall appointment, the restorations were evaluated using modified California Dental Association (CDA) criteria. The periodontal probing depth, bleeding index, presence of caries and implant survival and success rate were recorded. Results: No biological complications were recorded for any restorations. The success and survival rate of all implants was 100%. The overall mean survival and success rate of all restorations was 99.6%. In the veneered group, the predominant complication was minor veneer chipping (13.9%) on the incisal edge, which required only polishing (grade 1); in the non-veneered group, the predominant failure was open proximal contacts between the implant restoration and adjacent teeth (9%); only one implant restoration needed repair. One restoration was replaced due to a horizontal tooth fracture. Conclusions: Within the limitations of this study, we conclude that the survival and success rate of monolithic zirconia restorations installed in patients with bruxism was excellent, although the veneered zirconia restorations showed a high rate of minor veneer chipping, which required only polishing. (C) 2019 Published by Elsevier Ltd on behalf of Japan Prosthodontic Society.
The static and dynamic load-bearing capacities and failure modes of zirconia crowns screwed to multi-unit abutments (MUAs) with and without a titanium base (T-base) were determined. Thirty-six monolithic zirconia crowns screwed to straight MUAs torqued to laboratory analogs (30 Ncm) were assigned to two groups (n = 18). In group A, the zirconia crowns were screwed directly to the MUAs; in group B, the zirconia crowns were cemented to the T-base and screwed to the MUAs. All specimens were aged in 100% humidity (37 °C) for one month and subjected to thermocycling (20,000 cycles). Afterwards, the specimens underwent static and dynamic loading tests following ISO 14801. The failure modes were evaluated by stereomicroscopy (20×). There was an unequivocally similar trend in the S-N plots of both specimen groups. The load at which the specimens survived 5,000,000 cycles was 250 N for both groups. Group A failed mainly within the metal, and zirconia failure occurred only at a high loading force. Group B exhibited failure within the metal mostly in conjunction with adhesive failure between the zirconia and T-base. Zirconia restoration screwed directly to an MUA is a viable option, but further studies with larger sample sizes are warranted.
Endodontic treatment is often required due to pulp pathology caused by dental caries. Treatment is carried out by cleaning and shaping the tooth canal with endodontic instruments that mechanically remove the inner infected layer of root dentine, followed by filling and sealing the root canal. Roots of endodontically treated teeth are prone to cracks or fractures, with vertical root fracture (VRF) as the most common. VRF tends to occur in a bucco-lingual direction, where dentin thickness is greatest. Epidemiologic studies show that the prevalence of VRF is higher in the maxillary second premolar compared to maxillary incisors. Various parameters influence the occurrence of VRF. Obviously, the mechanical properties of the root dentine and root morphology are factors influencing these pathologies. However, assessing the strength properties of the entire root from isolated small specimens is an approach with major interpretative limitations, due to ultrastructural and anatomical variations [1,2]. Testing the strength of the roots as entire anatomic structure or comparing the strength of different roots types were done by destructive methodologies where teeth were loaded up to failure by compressive forces applied to the root by clinical hand spreaders or via a loading machine [3]. Hydrostatic pressure introducing into root canal to create VRF overcome the stress concentrations resulted by such stiff tools [4]. Finite elements models lack the complexity of inhomogeneous and anisotropic root dentine structure. The aim of this study was to quantify the bursting pressure and circumferential strains developing on root dentine surface during VRF and to relate them to morphologic parameters.