Established methods for the determination of burnup in nuclear fuels commonly rely on the measurement of 148Nd in the spent fuel in concert with known fission product yields to determine the atom percent of fissions in the fuel. This isotope of neodymium is used for various reasons, including chemical and radioactive stability, ease of measurement, and low rates of formation and destruction due to neutron flux apart from fission. However, careful calculation of effective cumulative fission yields and correction factors for (n,gamma) capture reactions allows for additional stable and long-lived isotopes of neodymium to be used to provide additional independent measurements of burnup, reducing statistical uncertainty. This method was developed and successfully applied to measure the burnup of compacts from the Advanced Gas Reactor (AGR) Fuel Development and Qualification Program. The mean burnup measured using 143Nd, 145Nd, 146Nd, 148Nd, and 150Nd was statistically observed to be the same as that measured using 148Nd alone, but the statistical uncertainty in the measurement was reduced by a factor of 2, providing a tighter confidence interval in the final results.
In this work, experimental results leading to flowsheet design are presented showing how a calixarene-crown ether based solvent-extraction process can meet the challenge of cesium removal from nuclear tank wastes stored at the US Department of Energy Hanford site. Cleanup of legacy Cold War nuclear waste stored in underground tanks represents one of the greatest environmental challenges facing the US Department of Energy in terms of risk, cost, and effectiveness of applicable science and technology. Planning for the cleanup at the Hanford Site calls for the removal of the radioactive fission product 137Cs from its alkaline salt waste, including the use of modular processes that can be deployed near the tank farms. To meet the resulting need for extremely high selectivity, the Next-Generation Caustic-Side Solvent Extraction (NG-CSSX) process employing a calix[4]arene-crown ether in modified kerosene has been adapted to remove sub-millimolar cesium in competition with molar sodium and potassium in a high-nitrate alkaline matrix. Potassium loading in the solvent was determined in extraction, scrubbing, and stripping, leading to an empirical model closely approximating cesium distribution ratios for a variety of Hanford waste types. Process chemistry has been developed based on this molecular-recognition approach, focusing on the competitive effect of potassium loading and the mitigating process modifications needed, including extending the scrub section. The result is a modular flowsheet design that can achieve cesium decontamination factors well in excess of 15,000 even for the worst-case Hanford waste.
Here we present the application of a novel analytical approach for high-speed evaluation of burn-up in spent nuclear fuel. This automated online separation–direct analysis method, which simultaneously measures the isotopic compositions and concentrations of Nd, Pu, and U using isotope dilution-inductively coupled plasma mass spectrometry, enables the determination of burnup in as little as 4.5 h per sample with expanded uncertainties as low as 1.2% using as little as 1µg of fuel. We compare the determined burn-up values, sample requirements, and analysis times with an ultra-high precision, in-house developed, methodology which employs multiple analytical techniques to measure the isotopic compositions and concentrations of Nd, Pu, and U yielding burn-up values with expanded uncertainties as low as 0.49% at the 95% confidence level, the lowest reported to date.
Conditions have been identified in which phenolic aldoximes and ketoximes of the types used in commercial solvent extraction processes can be doubly deprotonated and generate polynuclear Cu complexes with lower extractant:Cu molar ratios than those found in commercial operations. Electrospray mass spectrometry has provided an insight into the solution speciation in extraction experiments and has identified conditions to allow isolation and characterization of polynuclear Cu-complexes. Elevation of pH is effective in enhancing the formation of trinuclear complexes containing planar {Cu3-μ3-O}4+ or {Cu3-μ3-OH}5+ units. DFT calculations suggest that such trinuclear complexes are more stable than other polynuclear species. Solid structures of complexes formed by a salicylaldoxime with a piperidino substituent ortho to the phenolic OH group (L9H2) contain two trinuclear units in a supramolecular assembly, {[Cu3OH(L9H)3(ClO4)](ClO4)} 2, formed by H-bonding between the central {Cu3-μ3-OH}5+ units and oxygen atoms in the ligands of an adjacent complex. Whilst the lower ligand:Cu molar ratios provide more efficient Cu-loading in solvent extraction processes, the requirement to raise the pH of the aqueous phase to achieve this will make it impractical in most commercial operations because extraction will be accompanied by the precipitation (as oxyhydroxides) of Fe(III) which is present in significant quantities in feed solutions generated by acid leaching of most Cu ores.
This review was conducted by a collaboration of national laboratory and private sector participants with significant industrial experience, including some heavy lifting and deep diving from Clarus Consulting, LLC., all intended to achieve an objective, independent, and practical perspective. The report provides recommendations, descriptions of the evaluation methods, and the source references for the data used. To build confidence required for endorsement of the Code, this review was conducted as a verification and validation of the above Code contents. The objective of verification is to ensure that the Code is free of error – direct or implied; contains the information needed for its use, including proper coverage of the Code-specified materials for the intended application, and completeness and adequacy of references to other portions of the Code. The objective of validation is to authenticate that the Code tabulations and graphs represent design inputs consistent with what are determined using rules and methods specified by the Code. The authentication process used data that were assembled and/or generated independent of Code development, while the methods of analysis followed Code-specified methods where appropriate. The designated portions for this review cover the five alloys codified for high temperature reactor applications in Division 5, i.e. 316 SS, 304 SS, 800H, 2¼Cr-1Mo, and 9Cr-1Mo-V, regarding their general requirements, permitted specifications and design stress intensity values for pressure-retaining applications, deterioration in service, fatigue acceptance test, permissible weld materials, tensile and yield strength, expected minimum stress-to-rupture values (including for Alloy 718), weld stress rupture factors, permissible materials for bolting use, and restricted specifications in certain service applications. Additionally, stress intensity values for bolting materials including 316 SS, 304 SS and alloy 718 were reviewed. Analysis and discussion are also provided on contents outside of these designated Code portions where it was deemed relevant and necessary to develop a technically sound understanding of issues relating to the designated portions. Due to unavailability of sufficient test data on welds during the review period, the weld stress rupture factors in Tables HBB-I-10.14A to E, which cover a total of ten tables for the five alloys welded with twenty-eight different weld metals (some with similar properties), have been deferred to a future review effort. The review identified mainly two types of issues. The first type includes instances where the Code is found factually incomplete or incorrect, such as obsolete materials specifications listings, missing tabulation of stresses for bolting. Changes to the Code are recommended in these cases. The second type of issue includes instances where the Code tabulations and graphs are found to be less conservative than the review analysis results. In these cases, recommendations are made for further review and consideration where the difference in conservatism exceeds 10%, which is our threshold for questioning technical adequacy, meriting a risk assessment by the Nuclear Regulatory Commission and/or reactor designers. It is noted that this effort has been executed using all available data and established methods of analysis, including methods and criteria specified and used by the Code. As such, the findings that are presented in quantitative detail, in a format for convenient comparison with the Code, and with identification of where further review is recommended, should provide a sound technical basis for decisions about quantifying the implications of the reduced design margins and technical adequacy/inadequacy to form a basis for conditioning specific Code tabulation values on endorsement. Recommendations for specific changes to the Code, however, entail design conservatism considerations beyond the scope of this review effort, and are not made in this report.
Abstract Two plutonium oxides were prepared as unique reference materials for measurement of actinide elements present as trace constituents. Each reference material unit is approximately 200 mg of PuO2 powder in a quartz glass bottle. Characterized attributes of the oxides included mass fractions of plutonium, americium, neptunium, and uranium. Isotope-amount ratios were also determined for plutonium and uranium, but neptunium and americium were observed to be monoisotopic 237Np and 241Am. Measurements for characterization and verification of the attributes show that plutonium and trace actinides are homogeneous with the exception of limited heterogeneity for uranium, primarily observed for the 238U isotope. Model purification ages calculated from measured americium and uranium attribute values are consistent with material histories and indicate that these impurities are predominantly due to the decay of plutonium isotopes.
Direct isotope ratio analysis of solid uranium particulates on cotton swipes was achieved using a solution-based microextraction technique, coupled to a quadrupole inductively coupled plasma - mass spectrometer (ICP-MS). This microextraction-ICP-MS methodology provides rapid isotopic analysis which could be applicable to nuclear safeguards measurements. Particulates of uranyl nitrate hexahydrate (UO2(NO3)2·6H2O) and uranyl fluoride (UO2F2) ranging from 6 μm to 40 μm in length were transferred to cotton swipes with a particle manipulator. The microextraction probe then delivers a 5% nitric acid (HNO3) solvent onto the swipe surface to extract the uranium species. The extracted sample is then delivered to the ICP-MS for isotopic determination. The majority of uranium signal (∼99% and ∼94% for UO2(NO3)2·6H2O and UO2F2, respectively) was detected in the first 15 s extraction, while subsequent extractions on the same location had low or no U signal, suggesting near complete removal of the solid uranium compounds from the swipe surface. Ten samples (for each of the uranium compounds), were analyzed for their isotopic composition. For UO2(NO3)2·6H2O, the determined isotope ratios resulted in a % relative difference (% RD) from the referenced isotope ratios of 0.97, 1.0, and 7.3% for 234U/238U, 235U/238U, and 236U/238U, respectively. The % RD of the UO2F2 isotope ratios were 1.9 and 0.60% for 234U/238U and 235U/238U, respectively. The preliminary limits of detection were determined to be 0.002, 0.4, and 60 pg for 234U, 235U and 238U, respectively This work demonstrates that microextraction ICP-MS is a rapid and sensitive method that could directly determine uranium isotope ratios of UO2(NO3)2·6H2O and UO2F2 particulates on cotton swipes.
have been calibrated to match the measured data. The new public-domain, free-to-use tool will help the US industry design their AC units using the new refrigerants and shorten the learning curve.
Presented here is a novel automated method for determining the trace element composition of bulk thorium by inductively coupled plasma–optical emission spectroscopy (ICP-OES). ICP-OES is a universal approach for measuring the trace elemental impurities present in actinide-rich materials; however, due to the emission rich spectrum of the actinide, a separation from the trace elements is warranted for spectrochemical analysis. Here, AG MP-1 ion exchange resin was utilized for retention of the Th matrix, while allowing the trace element impurities to be separated prior to subsequent analysis using ICP-OES. After demonstrating the separation on traditional gravity-driven columns, the methodology was transitioned to an automated platform for comparison. This automated platform utilizes syringe-driven sample and solvent flow and can collect the trace element and thorium fractions in separate locations. While reducing the sample size (500 µL, 1.5 mg of Th), maintaining the overall separation efficiency (recoveries >95%), and illustrating the sample throughput ability (n = 10+), this automated methodology could be readily adopted to nuclear facilities in which the determination of trace elemental impurities in Th samples is warranted.
The ability to directly measure uranium isotope ratios on environmental swipes has been achieved through a solution-based microextraction process and represents a significant advancement toward the development of a rapid method to analyze international nuclear safeguard samples. Here, a microextraction probe is lowered and sealed onto the swipe surface, and analytes within the sampling site (∼8 mm2) are dissolved and extracted into a flowing solvent of 2% nitric acid (HNO3). The mobilized species are subsequently directed into an inductively coupled plasma-mass spectrometer (ICP-MS) for accurate and precise isotope ratio determination. This work highlights the novelty of the sampling mechanism, particularly with the direct coupling of the microextraction probe to the ICP-MS and measurement of uranium isotope ratios. The preliminary method detection limit for the microextraction-ICP-MS method, utilizing a quadrupole-based MS, was determined to be ∼50 pg of 238U. Additionally, precise and accurate isotope ratio measurements were achieved on uranium reference materials for both the major (235U/238U) and minor (234U/238U and 236U/238U) ratios. While the present work is focused on directly measuring uranium isotopic systems on swipe surfaces for nuclear safeguards and verification applications, the benefits would extend across many applications in which direct solid sampling is sought for elemental and isotopic analysis.
This study demonstrates a method for determining the isotopic composition of low-level (sub-pg) plutonium (Pu) directly from a cotton swipe.
The determination of trace elements, particularly rare earth elements, in uranium ore concentrates (UOCs) is important as the pattern can be indictive ore characteristics. Presented here is a methodology for accurately quantifying rare earth elements (REE) in UOCs. To improve the measurement uncertainty, isotope dilution mass spectrometry (IDMS) was utilized over other quantification techniques such as external calibration or standard addition. The isotopic determinations were measured by inductively coupled plasma-mass spectrometry (ICP-MS). To obtain high-fidelity isotopic measurements, separation of the REE from the uranium matrix was achieved by high-performance ion chromatography (HPIC), reducing the isobaric interferences. After separation, the target analytes were analyzed in two different modalities. For high precision analysis, the separated analytes were collected and measured by ICP-MS in an "offline" fashion. For a rapid approach, the separated analytes were sent directly into an ICP-MS for "online" analysis. These methods have been demonstrated to accurately quantify the REE content in a well-characterized UOC sample.
Analysis of irradiated material shortly after irradiation can be non-trivial due to highly radioactive activation and fission isotopes increasing dead time in gamma-ray detection systems, often requiring a “cooling-period” between receipt of a sample and the subsequent analysis. A direct separation–detection method has been developed combining ion chromatography and inductively coupled mass spectrometry for rapid, low-level analysis of fission products; it cannot, however, detect certain short-lived species below the detection limit of the system. Here we report the implementation of an inline gamma-ray detector, which was added post-separation, pre-analysis, to test the quality and utility of elementally-isolated gamma-ray spectroscopy.
This appendix documents the status of the ORNL Phase 1 DE activities related to fission gas sample analysis, fuel burnup analysis, and fuel isotopic analysis of selected sister specimens in Phase 1 of the sister rod test program.