Background The purpose of this study is to compare a new temporary triple-lumen catheter (TLC) for dialysis that has a third lumen devoted to fluid and medication administration or blood sampling with a marketed dual-lumen catheter (DLC). Methods Four hundred eighty-five patients referred for acute hemodialysis or apheresis were randomly assigned to either a TLC or DLC in a multicenter, prospective, randomized trial. Results: Analysis of blood flow rates was completed on 464 patients (228 patients, DLC; 236 patients, TLC) with a total of 1,681 hemodialysis (808 treatments, DLC; 873 treatments, TLC) and 82 apheresis treatments (37 treatments, DLC; 45 treatments, TLC). During hemodialysis, a median achieved flow rate (AFR) of 267 mL/min was realized for both groups (P = 0.58). During apheresis, a median AFR of 72.5 mL/min (range, 50 to 150 mL/min) was achieved in the DLC group, and 87 mL/min (range, 60 to 150 mL/min), in the TLC group (P = 0.14). Three hundred ninety-three patients (193 patients, DLC; 200 patients, TLC) had blood and catheter tip cultures performed on removal, and catheter-related bloodstream infection (CRBSI) status was determined. Thirty-one patients (7.9%) had a CRBSI: 16 patients (8.3%), DLC; and 15 patients (7.5%), TLC (P = 0.77). Incidence densities of CRBSI were 12.4/1,000 DLC-days and 10.2/1,000 TLC-days (P = 0.59). The CRBSI incidence of 18.2/1,000 catheter-days for femoral sites was significantly greater than the 7/1,000 catheter-days for jugular sites (P = 0.02) and 6.6/1,000 catheter-days for combined jugular and subclavian sites (P = 0.01). In multivariate analysis, antibiotic use was the only factor related to CRBSI (odds ratio, 0.30; 95% confidence interval, 0.12 to 0.76). There were no statistically significant differences in rates of other complications between the 2 catheters. Conclusion: Results show that the new TLC is similar to the marketed DLC.
Internal jugular vein cannulation has become the preferred approach for temporary hemodialysis catheter placement following reports of an increased incidence of subclavian vein stenosis due to subclavian vein catheterization. Internal jugular vein catheterization is associated with a high rate of successful catheter placement. However, significant complications such as internal carotid artery (ICA) puncture, pneumothorax, vessel erosion, thrombosis, airway obstruction and infection can occur. The most common complication is ICA puncture. More recently a few cases of thyrocervical trunk pseudoaneurysm and fistula following internal jugular vein and subclavian vein catheterization attempts have been reported. Patients with renal failure who are on hemodialysis may have to undergo multiple catheter placements and vascular access interventions. This, along with their comorbid conditions, increases the risk of such complications. Here we report a patient on hemodialysis who developed transverse cervical artery pseudoaneurysm following an attempted right internal jugular vein catheterization. We report this case because of its rarity, to raise awareness of such a complication and to discuss different treatment options, in particular endovascular coil occlusion. A review of relevant literature is also presented.
therapy 53 Adverse events 455 -reactions 455 AIDS 332 Allograft rupture 71 Alloimmune hemolysis 473 Ammonium chloride 74 Amyloidosis 68 Anemia 27, 89 Angiotensin II 373 Angiotensin-converting enzyme inhibitors 149, 268 Anion gap 369 Ankle-arm blood pressure index 107 Anticardiolipin antibodies 351 Antilactoferrin antibody 57 Antineutrophil cytoplasmic antibody 57 Antiretroviral therapy 332 Aorto-iliac atherosclerosis 487 Arterial blood gas values 319 Aspergillus 329 AST-120 232 Atheroembolization 263 Atherosclerosis 107, 487 Axillo-femoral bypass 487 Basement membrane 175 Behçet disease 68, 217 Bidialysis 429 Big men 429 Bioelectrical impedance analysis 311 Biological markers 48 Blood pressure 193 Body mass index 169 Bone markers 283 -turnover