Objective The aim of this work was the development of an augmented reality system including the functionality of conventional surgical navigation systems.Methods An application software for the Augmented Reality System HoloLens 2 from Microsoft was developed. It detects the position of the patient as well as position of surgical instruments in real time and displays it within the two-dimensional (2D) magnetic resonance imaging or computed tomography (CT) images. The surgical pointer instrument, including a pattern that is recognized by the HoloLens 2 sensors, was created with three-dimensional (3D) printing. The technical concept was demonstrated at a cadaver skull to identify anatomical landmarks.Results With the help of the HoloLens 2 and its sensors, the real-time position of the surgical pointer instrument could be shown. The position of the 3D-printed pointer with colored pattern could be recognized within 2D-CT images when stationary and in motion at a cadaver skull. Feasibility could be demonstrated for the clinical application of transsphenoidal pituitary surgery.Conclusion The HoloLens 2 has a high potential for use as a surgical navigation system. With subsequent studies, a further accuracy evaluation will be performed receiving valid data for comparison with conventional surgical navigation systems. In addition to transsphenoidal pituitary surgery, it could be also applied for other surgical disciplines.
Background: Brain biopsy is required for the accurate specification and further diagnosis of intracranial findings. The conventional stereotactic frames are used clinically for biopsies and offer the highest possible precision. Unfortunately, they come with some insurmountable technical and logistical limitations. The aim of the present work is to determine the clinical precision in the needle biopsy of the human brain using a new patient-specific stereotactic navigation device based on 3D printing. Methods: MRI data sets of human cadaver heads were used to plan 32 intracranial virtual biopsy targets located in different brain regions. Based on these data, 16 individualized stereotactic frames were 3D-printed. After the intraoperative application of the stereotactic device to the cadaver’s head, the actual needle position was verified by postoperative CT. Results: Thirty-two brain areas were successfully biopsied. The target point accuracy was 1.05 ± 0.63 mm, which represents the difference between the planned and real target points. The largest target point deviation was in the coronal plane at 0.60 mm; the smallest was in the transverse plane (0.45 mm). Conclusions: Three-dimensional-printed, personalized stereotactic frames or platforms are an alternative to the commonly used frame-based and frameless stereotactic systems. They are particularly advantageous in terms of accuracy, reduced medical imaging, and significantly simplified intraoperative handling.
The use of stereotactic frames is a common practice in neurosurgical interventions such as brain biopsy and deep brain stimulation. However, conventional stereotactic frames have been shown to require modification and adaptation regarding patient and surgeon comfort as well as the increasing demand for individualized medical treatment. To meet these requirements for carrying out state-of-the-art neurosurgery, a 3D print-based, patient-specific stereotactic system was developed and examined for technical accuracy. Sixteen patient-specific frames, each with two target points, were additively manufactured from PA12 using the Multi Jet Fusion process. The 32 target points aim to maximize the variability of biopsy targets and depths for tissue sample retrieval in the brain. Following manufacturing, the frames were measured three-dimensionally using an optical scanner. The frames underwent an autoclave sterilization process prior to rescanning. The scan-generated models were compared with the planned CAD models and the deviation of the planned target points in the XY-plane, Z-direction and in the resulting direction were determined. Significantly lower (p < 0.01) deviations were observed when comparing CAD vs. print and print vs. sterile in the Z-direction (0.17 mm and 0.06 mm, respectively) than in the XY-plane (0.46 mm and 0.16 mm, respectively). The resulting target point deviation (0.51 mm) and the XY-plane (0.46 mm) are significantly higher (p < 0.01) in the CAD vs. print comparison than in the print vs. sterile comparison (0.18 mm and 0.16 mm, respectively). On average, the results from the 32 target positions examined exceeded the clinically required accuracy for a brain biopsy (2 mm) by more than four times. The patient-specific stereotaxic frames meet the requirements of modern neurosurgical navigation and make no compromises when it comes to accuracy. In addition, the material is suitable for autoclave sterilization due to resistance to distortion.
Restoration of mobility of the elbow after post-traumatic elbow stiffening due to osteophytes is often a problem. The anatomical structures were segmented within the CT-scan. Afterwards, the Multi Jet Fusion 3D-printing was applied to create the model made of biocompatible and steam-sterilizable plastic. Preoperative simulation of osteophyte resection at the 3D-model was performed as well as the direct comparison with the patient anatomy intraoperatively. The patient-specific was very helpful for the preoperative simulation of the resection of elbow osteophytes. The 3D anatomical representation improved the preoperative plan its implementation. A high degree of fidelity was found between the 3D Printed Anatomical representation and the actual joint pathology. Arthrolysis of complex post-traumatic bony changes is an important indication for the use of 3D models for preoperative planning. Due to the use of 3D printing and software simulation, accurate resection planning is feasible and residual bony stiffening can be avoided. 3D printing models can lead to an improvement in surgical quality.
Optical neuronavigation systems using infrared light to create a virtual reality image of the brain allow the surgeon to track instruments in real time. Due to the high vulnerability of the brain, neurosurgical interventions must be performed with a high precision. The aim of the experimental cadaveric study was to determine the application accuracy of a frameless optical neuronavigation system as guide for craniotomies by determining the target point deviation of predefined target points at the skull surface in the area of access to the cerebrum, cerebellum and the pituitary fossa. On each of the five canine cadaver heads ten target points were marked in a preoperative computed tomography (CT) scan. These target points were found on the cadaver skulls using the optical neuronavigation system. Then a small drill hole (1.5 mm) was drilled at these points. Subsequently, another CT scan was made. Both CT data sets were fused into the neuronavigation software, and the actual target point coordinates were identified. The target point deviation was determined as the difference between the planned and drilled target point coordinates. The calculated deviation was compared between two observers. The analysis of the target point accuracies of all dogs in both observers taken together showed a median target point deviation of 1.57 mm (range: 0.42 to 5.14 mm). No significant differences were found between the observers or the different areas of target regions. The application accuracy of the described system is similar to the accuracy of other optical neuronavigation systems previously described in veterinary medicine, in which mean values of 1.79 to 4.3 mm and median target point deviations of 0.79 to 3.53 mm were determined.
Introduction Individuals with Parkinsonian disorders often face limited access to specialized physiotherapy and movement training due to staff shortages and increasing disease incidence, resulting in a rapid decline in mobility and feelings of despair. Addressing these challenges requires allocating adequate resources and implementing specialized training programs to ensure comprehensive care and support. Regarding these problems, a computer software was invented that might serve as an additional home-based extension to conventional physiotherapy. Methods The trial took place in a rehabilitation center where every patient received equivalent treatment apart from the training program that was set up to be investigated over 3 weeks. Seventy four Patients were included and randomized between two intervention and one control group. Intervention group 1 (IG1) trained with the computer-based system two times a week while Intervention group 2 (IG2) received five training sessions a week. Using the markerless Microsoft Kinect® camera, participants controlled a digital avatar with their own body movements. UPDRS-III and Clinical measurements were performed before and after the three-week period. Results Patients in all groups improved in UPDRS-III pre and post intervention whereas reduction rates were higher for IG1 (−10.89%) and IG2 (−14.04%) than for CG (−7.74%). Differences between the groups were not significant (value of ps CG/IG1 0.225, CG/IG2 0.347). Growth rates for the arm abduction angle were significantly higher in IG1 (11.6%) and IG2 (9.97%) than in CG (1.87%) (value of ps CG/IG1 0.006 and CG/IG2 0.018), as was the 5-steps-distance (CG 10.86% vs. IG1 24.5% vs. UG2 26.22%, value of ps CG/IG1 0.011 and CG/IG2 0.031). Discussion The study shows the beneficial effects of computer-based training and substantiates the assumption of a similar impact in a home-based setting. The utilized software is feasible for such interventions and meets with the patient’s approval. Group dynamics seem to have an additional supporting effect for the aspired objective of improving mobility and should be seen as an essential aspect of video games in therapy.
Three-dimensional (3D) printing techniques for patient-individual medicine has found its way into veterinary neurosurgery. Because of the high accuracy of 3D printed specific neurosurgical navigation devices, it seems to be a safe and reliable option to use patient-individual constructions for sampling brain tissue. Due to the complexity and vulnerability of the brain a particularly precise and safe procedure is required. In a recent cadaver study a better accuracy for the 3D printed MRI-based patient individual stereotactic brain biopsy device for dogs is determined compared to the accuracies of other biopsy systems which are currently used in veterinary medicine. This case report describes the clinical use of this 3D printed MRI-based patient individual brain biopsy device for brain sampling in three dogs. The system was characterized by a simple handling. Furthermore, it was an effective and reliable tool to gain diagnostic brain biopsy samples in dogs with no significant side effects.
Abstract Background Brain biopsy of intracranial lesions is often necessary to determine specific therapy. The cost of the currently used stereotactic rigid frame and optical tracking systems for brain biopsy in dogs is often prohibitive or accuracy is not sufficient for all types of lesion. Objectives To evaluate the application accuracy of an inexpensive magnetic resonance imaging‐based personalized, 3D printed brain biopsy device. Animals Twenty‐two dog heads from cadavers were separated into 2 groups according to body weight (<15 kg, >20 kg). Methods Experimental study. Two target points in each cadaver head were used (target point 1: caudate nucleus, target point 2: piriform lobe). Comparison between groups was performed using the independent Student's t test or the nonparametric Mann‐Whitney U Test. Results The total median target point deviation was 0.83 mm (range 0.09‐2.76 mm). The separate median target point deviations for target points 1 and 2 in all dogs were 0.57 mm (range: 0.09‐1.25 mm) and 0.85 mm (range: 0.14‐2.76 mm), respectively. Conclusion and Clinical Importance This magnetic resonance imaging‐based 3D printed stereotactic brain biopsy device achieved an application accuracy that was better than the accuracy of most brain biopsy systems that are currently used in veterinary medicine. The device can be applied to every size and shape of skull and allows precise positioning of brain biopsy needles in dogs.
Background: Periprosthetic fractures (PPF) of the femur close to the hip joint have serious consequences for most geriatric affected patients. In principle, apart from the highly uncommon conservative therapy, there are two therapeutic options. On the one hand, the prosthesis-preserving treatment by means of osteosynthesis using plates and/or cerclages in general is available. On the other hand, a (partial) change of the prosthesis with optionally additive osteosynthesis or a proximal femoral replacement can be performed because of prosthesis loosening or non-reconstructable comminuted fractures as well as most cemented stem variations. The aim of this retrospective study is the analysis of periprosthetic proximal femoral fractures in the presence of a total hip arthroplasty (THA). The outcome of the operated patients is to be investigated depending on the type of care (osteosynthesis with prosthesis preservation vs. prosthesis change). Material and methods: In a retrospective case analysis, 80 patients with THA and PPF were included. They were divided into two groups. Group I represents the osteosynthetic treatment to preserve the implanted THA (n=42). Group II (n=38) includes those patients who were treated by a change of their endoprosthesis with or without additional osteosynthesis. Specifics of all patients, like gender, age at fracture, interval between fracture and implantation, length of in-patient stay, body mass index, osteoporosis, corticomedullary index and complications such as infections, re-fracture, loosening, material failure or other complications, were recorded and compared. Furthermore, the patients were re-examined by a questionnaire and the score according to Merle d'Aubigné and Postel. Results: In group I the mean follow-up time was 48.5±23 months (4 years) whereas group II amounted 32.5±24.5 months (2.7 years) (p=0.029). Besides, there were significant differences in age (81± 11 years vs. 76±10 years, p=0.047) and length of in-patient stay (14.5±8.6 days vs. 18.0±16.7 days, p=0.014). According to the score of Merle d'Aubigné and Postel, there were significantly better values for the pain in group II with comparable values for mobility and walking ability. Conclusion: The treatment of periprosthetic proximal fractures of the femur is dependent on the classification (Vancouver and Johannsen) and in particular on the prosthetic anchoring as well as the extent of the comminution zone. Older patients and patients with osteoporosis are more frequently treated with an endoprosthesis revision. Patients, who have been treated with an osteosynthesis for preserving their endoprosthesis, showed a shorter length of in-patient stay and fewer complications than people with replacement surgery. In contrast to that, patients with prosthesis revision had better outcomes concerning the score of Merle d'Aubigné and Postel.
The treatment of intracranial lesions requires a precise diagnosis with subsequent identification of an adequate therapeutic approach. Stereotactic tumor biopsy may be considered the safest neurosurgical procedure in terms of anticipated results and potential surgical complications. The aim of the present paper was to demonstrate a new method of stereotactic biopsy, based on a patient-specific 3D printed platform in dogs. The system was tested on two canine cadavers, a small (Shih Tzu) and a large (Labrador) breed. Imaginary biopsy targets were defined in a superficial (caudate nucleus) and a deep (piriform lobe) position. Based on 3 Tesla MRI, individualized stereotactic platforms were designed using a semi-automatic approach, and manufactured additively using ABS M30. A pre- and intra-operative CT was performed to compare the planned vs. the realized needle position for precision analyses of the procedure. The target points varied with a precision between 0.09 mm and 0.48 mm. Manufacturing time required 480 to 700 min per platform. The presented patient-specific stereotactic system seems a suitable instrument for application in small animal neurosurgery. In particular, the implementation of relevant stereotactic data may help performing the procedure in rapid sequence and with higher precision than currently-used systems. Required adjustments and adaptions to the respective anatomical conditions are omitted and make the procedure reliable and safe.
Background The importance of the vitamin D homeostasis in infections is already known. However, its significance in periprosthetic infections (PPIs) after total hip arthroplasty and total knee arthroplasty is largely unexplored. The aim of the study is to precisely analyze the vitamin D balance in patients with PPIs after total hip arthroplasty and total knee arthroplasty. Here, cases with primary endoprosthesis implants and aseptic loosening are used as comparison groups. Materials and methods In this prospective matched-pair analysis, patients with PPI at the hip and knee joints were included in the study group (SG). The control groups (CGs) consisted of patients with primary implants (CG I) and who underwent replacement surgery due to aseptic loosening (CG II). In addition to 25 OH vitamin D3 and calcium, bone mineral and protein parameters were determined. An osteoporosis-specific questionnaire was collected. Results There are no significant differences in the 25 OH-vitamin D levels between the SG (17.9±8.9) and both CGs (CG I: 16.8±6.90; CG II: 19.7±7.90). However, compared with the SG, significantly higher levels of calcium (Ca) and bone-specific alkaline phosphatase were found in both CGs in comparison with the SG. Significantly lower values concerning the protein balance in PPI were conspicuous. Acute PPI showed a significant reduction in 25 OH vitamin D3 compared with chronic infections (8.3±5.98 vs 21.6±8.40, P=0.002). Calcium and protein balance were also significantly reduced in acute PPIs. Conclusion Acute PPIs of the hip and knee joints show a significantly reduced calcium and 25 OH vitamin D3 levels as well as lowered proteins (albumin and total protein) compared with chronic infections as well as primary endoprostheses and aseptic replacement operations. Substitution of vitamin D3 and calcium with simultaneous adaptation of the protein balance is recommended in all PPIs, especially in the acute PPI.
Objectives The cervical part of the vagus nerve (CVN) has become an important target for stimulation therapy to treat epilepsy and psychiatric conditions. For this purpose, the CVN is visualized in the carotid sheath, assuming it to be localized dorsomedially between the carotid artery (CA) and the internal jugular vein (JV). The aim of our morphological study was therefore to revisit the CVN relationships to the CA and JV, hypothesizing it to have common variations to this classical textbook anatomy. Materials and Methods Positional relations of the CVN, CA and JV were investigated in the carotid sheath of 35 cadavers at the C3 to C6 level. Positional relations of the CVN, CA and JV were documented on the basis of a 3 × 3 chart. Results Eighteen different arrangements of the CVN, CA and JV were observed. The typical topographic relationship of the CVN dorsomedially between the CA and JV was only found in 42% of all cases. The CVN was located dorsally or (dorso-)laterally to the CA in 80% and dorsally or (dorso-)medially of the JV in 96% of all cases. Conclusions Classical textbook anatomy of the CVN is only present in a minority of cases. Positional variations in contrast to textbook anatomy are considerably more frequent than previously described, which might be a hypothetical morphological explanation for the lack of efficacy or side effects of CVN stimulation. Furthermore, the position of the CVN relative to the internal jugular vein is more consistent than to the CA.
The subthalamic nucleus (STN) is a main target structure of deep brain stimulation (DBS) in idiopathic Parkinson's disease. Nevertheless, there is an ongoing discussion regarding human STN volumes and neuron count, which could potentially have an impact on STN-DBS. Moreover, a suspected functional subdivision forms the basis of the tripartite hypothesis, which has not yet been morphologically substantiated. In this study, it was aimed to investigate the human STN by means of combined magnetic resonance imaging (MRI) and stereology. STN volumes were obtained from 14 individuals (ranging from 65 to 96 years, 25 hemispheres) in 3 T MRI and in luxol-stained histology slices. Neuron number and cell densities were investigated stereologically over the entire STN and in pre-defined subregions in anti-human neuronal protein HuC/D-stained slices. STN volumes measured with MRI were smaller than in stereology but appeared to be highly consistent, measuring on average 99 ± 6 mm3 (MRI) and 132 ± 20 mm3 (stereology). The neuron count was 431,088 ± 72,172. Both STN volumes and cell count decreased age-dependently. Neuron density was different for the dorsal, medial and ventral subregion with significantly higher values ventrally than dorsally. Small variations in STN volumes in both MRI and stereology contradict previous findings of large variations in STN size. Age-dependent decreases in STN volumes and neuron numbers might influence the efficacy of STN-DBS in a geriatric population. Though the study is limited in sample size, site-dependent differences for the STN subregions form a morphological basis for the tripartite theory. Hum Brain Mapp 38:909-922, 2017. © 2016 Wiley Periodicals, Inc.
Introduction Though xenogeneic acellular scaffolds are frequently used for surgical reconstruction, knowledge of their mechanical properties is lacking. This study compared the mechanical, histological and ultrastructural properties of various native and acellular specimens. Materials and Methods Porcine esophagi, ureters and skin were tested mechanically in a native or acellular condition, focusing on the elastic modulus, ultimate tensile stress and maximum strain. The testing protocol for soft tissues was standardized, including the adaption of the tissue’s water content and partial plastination to minimize material slippage as well as templates for normed sample dimensions and precise cross-section measurements. The native and acellular tissues were compared at the microscopic and ultrastructural level with a focus on type I collagens. Results Increased elastic modulus and ultimate tensile stress values were quantified in acellular esophagi and ureters compared to the native condition. In contrast, these values were strongly decreased in the skin after acellularization. Acellularization-related decreases in maximum strain were found in all tissues. Type I collagens were well-preserved in these samples; however, clotting and a loss of cross-linking type I collagens was observed ultrastructurally. Elastins and fibronectins were preserved in the esophagi and ureters. A loss of the epidermal layer and decreased fibronectin content was present in the skin. Discussion Acellularization induces changes in the tensile properties of soft tissues. Some of these changes appear to be organ specific. Loss of cross-linking type I collagen may indicate increased mechanical strength due to decreasing transverse forces acting upon the scaffolds, whereas fibronectin loss may be related to decreased load-bearing capacity. Potentially, the alterations in tissue mechanics are linked to organ function and to the interplay of cells and the extracellular matrix, which is different in hollow organs when compared to skin.
Introduction: Acellular scaffolds are frequently used for the surgical repair of ligaments and tendons. Even though data on the macro-mechanical properties related to the acellularization process exist, corresponding data on the nano-structural properties are still lacking. Such data would help identify target proteins of the formed extracellular matrix that are chemically altered by the acellularization. In this study we examined the altered structure by comparing molecular properties of collagens from native and acellular iliotibial tract samples to the macroscopic stress strain behavior of tract samples.Material and methods: Matched pairs of five human iliotibial tract samples were obtained from five donors (mean age 28.2 +/- 4.7 years). One of each pair was acellularized using 1 vol% sodium dodecyl sulfate (SDS) for 7 days. C-13 magic angle spinning nuclear magnetic resonance spectroscopy (C-13 CP MAS NMR) was utilized to compare the collagen overall secondary structure and internal dynamics of collagen-typical amino acid proteins. The resulting data was compared to age-matched stress strain data of tract samples obtained in an uniaxial tensile setup and histologically.Results: Typical and nearly identical collagen C-13 CP MAS NMR spectra were found in the tract samples before and after acellularization with SDS. The characteristic collagen backbone remained intact in the native and acellular samples. Collagen molecular composition was largely unaltered in both conditions. Furthermore, a similar dynamic behavior was found for the amino acids Hyp gamma, Pro alpha/Hyp alpha, Ala alpha, Gly alpha and Ala beta. These minute alterations in the collagens' molecular properties related to acellularization with SDS were in line with the similarly minute changes in the macro-mechanical tensile behavior, such as the elastic modulus and ultimate stress. Histology showed intact type I collagens, minute amounts of elastins before and after acellularization and evidence for acellularization-induced reductions of proteoglycans.Discussion: Nano-structural properties of collagens are minutely affected by SDS treatment for acellularization, indicated by the molecular composition and dynamics. The lacking acellularization-related changes in the molecular structure properties of collagens in iliotibial tract samples are in line with the small alterations in their macro-mechanical tensile behavior. Though the given setup approaches soft tissue mechanics from both scaling extremes of mechanical testing, further structural analyzes are needed in a larger sample size to substantiate these findings. (C) 2016 Elsevier Ltd. All rights reserved.
Introduction: Hip joint stability is maintained by the surrounding ligaments, muscles, and the atmospheric pressure exerted via these structures. It is unclear whether the ligaments are capable of preventing dislocation solely due to their tensile properties, and to what extent they undergo age-related changes. This study aimed to obtain stress-strain data of the hip ligaments over a large age range.Methods: Stress-strain data of the iliofemoral (IL), ischiofemoral (IS) and pubofemoral ligament (PF) were obtained from cadavers ranging between 14 and 93 years using a highly standardized setting. Maximum strains were compared to the distances required for dislocation.Results: Elastic modulus was 24.4 (IL), 22.4 (IS) and 24.9 N/mm(2) (PF) respectively. Maximum strain was 84.5%, 86.1%, 72.4% and ultimate stress 10.0, 7.7 and 65 N/mm(2) for the II, IS and PF respectively. None of these values varied significantly between ligaments or sides. The IS' elastic modulus was higher and maximum strain lower in males. Lower elastic moduli of the PF and higher maximum strains for the IS and PF were revealed in the >= 55 compared to the <55 population. Maximum strain exceeded the dislocation distance of the IS without external hip joint rotation in females, and of the IS and cranial IL under extemal rotation in both genders.Discussion: Tensile and failure load properties of the hip joint ligaments are largely variable. The IS and PF change age-dependently. Though the hip ligaments contribute to hip stability, the IS and cranial IL may not prevent dislocation due to their elasticity. (C) 2016 Elsevier Ltd. All rights reserved.
Introduction The sacroiliac joint (SIJ) is a common source of low back pain. However, clinical and functional signs and symptoms correlating with SIJ pain are widely unknown. Pelvic belts are routinely applied to treat SIJ pain but without sound evidence of their pain-relieving effects. This case-control study compares clinical and functional data of SIJ patients and healthy control subjects and evaluates belt effects on SIJ pain. Methods 17 SIJ patients and 17 healthy controls were included in this prospective study. The short-form 36 survey and the numerical rating scale were used to characterize health-related quality of life in patients in a six-week follow-up and the pain-reducing effects of pelvic belts. Electromyography data were obtained from the gluteus maximus, biceps femoris, rectus femoris and medial vastus. Alterations of muscle activity, variability and gait patterns were compared in patients and controls along with the belts’ effects in a dynamic setting when walking. Results Significant improvements were observed in the short-form 36 survey of the SIJ patients, especially in the physical health subscores. Minor declines were also observed in the numerical rating scale on pain. Belt-related changes of muscle activity and variability were similar in patients and controls with one exception: the rectus femoris activity decreased significantly in patients with belt application when walking. Further belt effects include improved cadence and gait velocity in patients and controls. Conclusions Pelvic belts improve health-related quality of life and are potentially attributed to decreased SIJ-related pain. Belt effects include decreased rectus femoris activity in patients and improved postural steadiness during locomotion. Pelvic belts may therefore be considered as a cost-effective and low-risk treatment of SIJ pain. Trial Registration ClinicalTrials.gov NCT02027038
Intraosseous infusion is recommended if peripheral venous access fails for cardiopulmonary resuscitation or other medical emergencies. The aim of this study, using body donors, was to compare a semi-automatic (EZ-IO®) device at two insertion sites and a sternal intraosseous infusion device (FASTR™).Twenty-seven medical students being inexperienced first-time users were randomized into three groups using EZ-IO and FASTR. The following data were evaluated: attempts required for successful placement, insertion time and flow rates with and without external pressure to the infusion.The first-pass insertion success of the EZ-IO tibia, EZ-IO humerus and FASTR was 91%, 77%, and 95%, respectively. Insertion times (MW ± SD) did not show significant differences with 17 ± 7 (EZ-IO tibia) vs. 29 ± 42 (EZ-IO humerus) vs. 33 ± 21 (FASTR), respectively. One-minute flow rates using external pressures between 0 mmHg and 300 mmHg ranged between 27 ± 5 to 69 ± 54 ml/min (EZ-IO tibia), 16 ± 3 to 60 ± 44 ml/min (EZ-IO humerus) and 53 ± 2 to 112 ± 47 ml/min (FASTR), respectively. Concerning pressure-related increases in flow rates, negligible correlations were found for the EZ-IO tibia in all time frames (c = 0.107-0.366; p ≤ 0.013), moderate positive correlations were found for the EZ-IO humerus after 5 minutes (c = 0.489; p = 0.021) and strong positive correlations were found for the FASTR in all time frames (c = 0.63-0.80; p ≤ 0.007). Post-hoc statistical power was 0.62 with the given sample size.The experiments with first-time users applying EZ-IO and FASTR in body donors indicate that both devices may be effective intraosseous infusion devices, likely suitable for fluid resuscitation using a pressure bag. Variations in flow rate may limit their reliability. Larger sample sizes will prospectively be required to substantiate our findings.