BACKGROUND:Malaria diagnostic testing remains a burden on healthcare systems. Here we present Remoscope, a portable imaging cytometer that scans fresh, unstained whole blood using a custom neural network running on low-cost hardware. Remoscope performs label-free, quantitative, stage-specific detection of Plasmodium falciparum (Pf) by screening up to 2 million red blood cells (RBCs) in 1-12 min, without sample fixation, staining or slide scanning. Low-cost disposable cartridges are used to confine flowing blood to an ultrathin sheet for imaging. METHODS:Performance was benchmarked in vitro by titration of cultured Pf (17.1-710 000 parasites/µl) into whole blood. A study of Remoscope's diagnostic accuracy was evaluated in a cohort of 500 individuals in eastern Uganda, comprising 601 unique clinic visits. Parallel measurements of parasitaemia were performed using Remoscope, quantitative polymerase chain reaction (qPCR) and thick blood smears. RESULTS:Clinically, Remoscope's 10× diluted blood assay had a limit of detection with respect to qPCR of 95.1 parasites/µl, sensitivity of 83%, specificity of 96%, positive predictive value of 91% and negative predictive value of 93%. CONCLUSIONS:Remoscope's speed, accuracy, cost and ease of use address key challenges in malaria diagnosis worldwide. In this pilot study, the diagnostic accuracy approaches that of expert thick smears performed in duplication.
Luminescence is ubiquitous in biology research and medicine. Conceptually simple, the detection of luminescence nonetheless faces technical challenges because relevant signals can exhibit exceptionally low radiant power densities. Although low light detection is well-established in centralized laboratory settings, the cost, size, and environmental requirements of high-performance benchtop luminometers are not compatible with geographically-distributed global health studies or resource-constrained settings. Here we present the design and application of a ~$700 US handheld, battery-powered luminometer with performance on par with high-end benchtop instruments. By pairing robust and inexpensive Silicon Photomultiplier (SiPM) sensors with a low-profile shutter system, our design compensates for sensor non-idealities and thermal drift, achieving a limit of detection of 1.6E-19 moles of firefly luciferase. Using these devices, we performed two pilot cross-sectional serology studies to assess sars-cov-2 antibody levels: a cohort in the United States, as well as a field study in Bangladesh. Results from both studies were consistent with previous work and demonstrate the device's suitability for distributed applications in global health.
Liquid chromatography purification of multiple recombinant proteins, in parallel, could catalyze research and discovery if the processes are fast and approach the robustness of traditional, “one-protein-at-a-time” purification. Here, we report an automated, four channel chromatography platform that we have designed and validated for parallelized protein purification at milligram scales. The device can purify up to four proteins (each with its own single column), has inputs for up to eight buffers or solvents that can be directed to any of the four columns via a network of software-driven valves, and includes an automated fraction collector with ten positions for 1.5 or 5.0 mL collection tubes and four positions for 50 mL collection tubes for each column output. The control software can be accessed either via Python scripting, giving users full access to all steps of the purification process, or via a simple-to-navigate touch screen graphical user interface that does not require knowledge of the command line or any programming language. Using our instrument, we report milligram-scale, parallelized, single-column purification of a panel of mammalian cell expressed coronavirus (SARS-CoV-2, HCoV-229E, HCoV-OC43, HCoV-229E) trimeric Spike and monomeric Receptor Binding Domain (RBD) antigens, and monoclonal antibodies targeting SARS-CoV-2 Spike (S) and Influenza Hemagglutinin (HA). We include a detailed hardware build guide, and have made the controlling software open source, to allow others to build and customize their own protein purifier systems.
BACKGROUND:SARS-CoV-2 rapid antigen tests are an important public health tool. OBJECTIVE:To evaluate field performance of the BinaxNOW rapid antigen test (Abbott) compared with reverse transcriptase polymerase chain reaction (RT-PCR) for detecting infection with the Omicron variant of SARS-CoV-2. DESIGN:Cross-sectional surveillance study. SETTING:Free, walk-up, outdoor, urban community testing and vaccine site led by Unidos en Salud, serving a predominantly Latinx community highly impacted by COVID-19. PARTICIPANTS:Persons seeking COVID-19 testing in January 2022. MEASUREMENTS:Simultaneous BinaxNOW and RT-PCR from nasal, cheek, and throat swabs, including cycle threshold (Ct) measures; a lower Ct value is a surrogate for higher amounts of virus. RESULTS:Among 731 persons tested with nasal swabs, there were 296 (40.5%) positive results on RT-PCR; 98.9% were the Omicron variant. BinaxNOW detected 95.2% (95% CI, 91% to 98%) of persons who tested positive on RT-PCR with a Ct value below 30, 82.1% (CI, 77% to 87%) of those who tested positive on RT-PCR with a Ct value below 35, and 65.2% (CI, 60% to 71%) of all who were positive on RT-PCR. Among 75 persons with simultaneous nasal and cheek swabs, BinaxNOW using a cheek swab failed to detect 91% (20 of 22) of specimens that were positive on BinaxNOW with a nasal swab. Among persons with simultaneous nasal and throat swabs who were positive on RT-PCR with a Ct value below 30, 42 of 49 (85.7%) were detected by nasal BinaxNOW, 23 of 49 (46.9%) by throat BinaxNOW, and 44 of 49 (89.8%) by either. LIMITATION:Participants were a cross-sectional sample from a community-based sentinel surveillance site, precluding study of viral or symptom dynamics. CONCLUSION:BinaxNOW detected persons with high SARS-CoV-2 levels during the Omicron surge, enabling rapid responses to positive test results. Cheek or throat swabs should not replace nasal swabs. As currently recommended, high-risk persons with an initial negative BinaxNOW result should have repeated testing. PRIMARY FUNDING SOURCE:University of California, San Francisco.
In 731 persons seeking COVID-19 testing at a walk-up San Francisco community site in January 2022, simultaneous nasal rapid antigen testing (BinaxNOWTM) and RT-PCR testing was performed. There were 296 (40.5%) positive tests by RT-PCR; 97% of a random sample were the omicron variant. Sensitivity of a single antigen test was 95.2% (95% CI 92-98%); 82.1% (95% CI 77-87%) and 65.2% (95% CI 60-70%) for Ct threshold of < 30, < 35 and no threshold, respectively. A single BinaxNowTM rapid antigen test detected 95% of high viral load omicron cases from nasal specimens. As currently recommended, repeat testing should be done for high- risk persons with an initial negative antigen test result.
Measuring optical density (OD) is a very common technique in biological laboratories to determine the concentration of a substance in solution or of bacteria (or microscopic particles) in suspension. For example, bacterial cultures engineered to produce (express) a protein or compound of interest are a workhorse of modern molecular biology laboratories. Commonly, the expression of the product is triggered (induced) by a chemical signal added to the culture at the proper time in the growth curve of the culture (typically in the middle of the exponential growth phase, at an OD value of ∼0.6). The most common tool for measuring OD is a spectrophotometer. However, most spectrophotometers are sophisticated, non-portable and expensive laboratory instruments, costing tens of thousands of dollars. Even a very low cost spectrophotometer for educational use costs at least US$1,000. Because of the cost, even well resourced labs have only one instrument, which becomes a bottleneck when multiple bacterial cultures need to be monitored simultaneously. The problem is more acute in developing countries, where multiple labs have to share a single spectrophotometer, or there’s no such instrument at all. Having a cheap and simple device to measure OD would enable multiple people in a laboratory to monitor their bacterial cultures independently, even in resource-limited settings. At the same time, a portable OD meter could be useful for field work. Here we present the detailed build instructions and characterization of a very simple OD meter that costs only US$60, and can measure OD values from ∼0.05 to 2.0. Specifications table
Author(s): Crawford, Emily D; Acosta, Irene; Ahyong, Vida; Anderson, Erika C; Arevalo, Shaun; Asarnow, Daniel; Axelrod, Shannon; Ayscue, Patrick; Azimi, Camillia S; Azumaya, Caleigh M; Bachl, Stefanie; Bachmutsky, Iris; Bhaduri, Aparna; Brown, Jeremy Bancroft; Batson, Joshua; Behnert, Astrid; Boileau, Ryan M; Bollam, Saumya R; Bonny, Alain R; Booth, David; Borja, Michael Jerico B; Brown, David; Buie, Bryan; Burnett, Cassandra E; Byrnes, Lauren E; Cabral, Katelyn A; Cabrera, Joana P; Caldera, Saharai; Canales, Gabriela; Castaneda, Gloria R; Chan, Agnes Protacio; Chang, Christopher R; Charles-Orszag, Arthur; Cheung, Carly; Chio, Unseng; Chow, Eric D; Citron, Y Rose; Cohen, Allison; Cohn, Lillian B; Chiu, Charles; Cole, Mitchel A; Conrad, Daniel N; Constantino, Angela; Cote, Andrew; Crayton-Hall, Tre'Jon; Darmanis, Spyros; Detweiler, Angela M; Dial, Rebekah L; Dong, Shen; Duarte, Elias M; Dynerman, David; Egger, Rebecca; Fanton, Alison; Frumm, Stacey M; Fu, Becky Xu Hua; Garcia, Valentina E; Garcia, Julie; Gladkova, Christina; Goldman, Miriam; Gomez-Sjoberg, Rafael; Gordon, M Grace; Grove, James CR; Gupta, Shweta; Haddjeri-Hopkins, Alexis; Hadley, Pierce; Haliburton, John; Hao, Samantha L; Hartoularos, George; Herrera, Nadia; Hilberg, Melissa; Ho, Kit Ying E; Hoppe, Nicholas; Hosseinzadeh, Shayan; Howard, Conor J; Hussmann, Jeffrey A; Hwang, Elizabeth; Ingebrigtsen, Danielle; Jackson, Julia R; Jowhar, Ziad M; Kain, Danielle; Kim, James YS; Kistler, Amy; Kreutzfeld, Oriana; Kulsuptrakul, Jessie; Kung, Andrew F
Microfluidic technologies have been used across diverse disciplines (e.g. high-throughput biological measurement, fluid physics, laboratory fluid manipulation) but widespread adoption has been limited in part due to the lack of openly disseminated resources that enable non-specialist labs to make and operate their own devices. Here, we report the open-source build of a pneumatic setup capable of operating both single and multilayer (Quake-style) microfluidic devices with programmable scripting automation. This setup can operate both simple and complex devices with 48 device valve control inputs and 18 sample inputs, with modular design for easy expansion, at a fraction of the cost of similar commercial solutions. We present a detailed step-by-step guide to building the pneumatic instrumentation, as well as instructions for custom device operation using our software, Geppetto, through an easy-to-use GUI for live on-chip valve actuation and a scripting system for experiment automation. We show robust valve actuation with near real-time software feedback and demonstrate use of the setup for high-throughput biochemical measurements on-chip. This open-source setup will enable specialists and novices alike to run microfluidic devices easily in their own laboratories.
The Sterol Regulatory Element Binding Proteins (SREBPs) are basic-helix-loop-helix transcription regulators that control the expression of sterol biosynthesis genes in higher eukaryotes and some fungi. Surprisingly, SREBPs do not regulate sterol biosynthesis in the ascomycete yeasts (Saccharomycotina) as this role was handed off to an unrelated transcription regulator in this clade. The SREBPs, nonetheless, expanded in fungi such as the ascomycete yeasts Candida spp., raising questions about their role and evolution in these organisms. Here we report that the fungal SREBPs diversified their DNA binding preferences concomitantly with an expansion in function. We establish that several branches of fungal SREBPs preferentially bind non-palindromic DNA sequences, in contrast to the palindromic DNA motifs recognized by most basic-helix-loop-helix proteins (including SREBPs) in higher eukaryotes. Reconstruction and biochemical characterization of the likely ancestor protein suggest that an intrinsic DNA binding promiscuity in the family was resolved by alternative mechanisms in different branches of fungal SREBPs. Furthermore, we show that two SREBPs in the human commensal yeast Candida albicans drive a transcriptional cascade that inhibits a morphological switch under anaerobic conditions. Preventing this morphological transition enhances C. albicans colonization of the mammalian intestine, the fungus' natural niche. Thus, our results illustrate how diversification in DNA binding preferences enabled the functional expansion of a family of eukaryotic transcription regulators.
The Tabula Muris ConsortiumWe have created a compendium of single cell transcriptome data from the model organism Mus musculus comprising more than 100,000 cells from 20 organs and tissues. These data represent a new resource for cell biology, revealing gene expression in poorly characterized cell populations and allowing for direct and controlled comparison of gene expression in cell types shared between tissues, such as T-lymphocytes and endothelial cells from distinct anatomical locations. Two distinct technical approaches were used for most tissues: one approach, microfluidic droplet-based 3’-end counting, enabled the survey of thousands of cells at relatively low coverage, while the other, FACS-based full length transcript analysis, enabled characterization of cell types with high sensitivity and coverage. The cumulative data provide the foundation for an atlas of transcriptomic cell biology.
Sequence libraries that cover all k-mers enable universal, unbiased measurements of binding to both oligonucleotides and peptides. While the number of k-mers grows exponentially in k, space on all experimental platforms is limited. Here, we shrink k-mer library sizes by using joker characters, which represent all characters in the alphabet simultaneously. We present the JokerCAKE (joker covering all k-mers) algorithm for generating a short sequence such that each k-mer appears at least p times with at most one joker character per k-mer. By running our algorithm on a range of parameters and alphabets, we show that JokerCAKE produces near-optimal sequences. Moreover, through comparison with data from hundreds of DNA-protein binding experiments and with new experimental results for both standard and JokerCAKE libraries, we establish that accurate binding scores can be inferred for high-affinity k-mers using JokerCAKE libraries. JokerCAKE libraries allow researchers to search a significantly larger sequence space using the same number of experimental measurements and at the same cost.