Background: The role of the "debrief" to address issues related to patient safety and systematic flaws in care is frequently overlooked. In our study, we interview surgical leaders who have developed successful strategies of debriefing within a comprehensive program of quality improvement. Methods: Semi-structured interviews of four implementation leaders were performed. The observations, beliefs and strategies of surgical leaders are compared and contrasted. Common themes are identified related to program success and failure. Quality and safety researchers performed, coded and categorized the interviews and coordinated the analysis and interpretation of the results. The authors from the four institutions aided in interpretation and framing of the results. Results: The debriefing programs evaluated were part of comprehensive quality improvement projects. Seven high-level themes and 24 subthemes were identified from the interviews. Themes related to leadership included early engagement, visible ongoing commitment and enforcement. Success appeared to depend upon meaningful and early debriefing feedback. The culture of safety that promoted success included a commitment to open and fair communication and continuous improvement. There were many challenges to the success of debriefing programs. The loss of institutional commitment of resources and personnel was the instigating factor behind the collapse of the program at Michigan. Other areas of potential failure included communication issues and loss of early and meaningful feedback. Conclusions: Leaders of four surgical systems with strong debriefing programs report success using debriefing to improve system performance. These findings are consistent with previously published studies. Success requires commitment of resources, and leadership engagement. The greatest gains may be best achieved by programs that provide meaningful debriefing feedback in an atmosphere dedicated to open communication.
PURPOSE:In 2010, a new study published by the National Lung Screening Trial showed a 20% reduction in mortality for those patients screened with low-dose computed topography (CT) versus x-ray. Recently, the Centers of Medicare and Medicaid have agreed to cover this service for those patients who meet the screening criteria. We compare the outcomes and costs associated with developing and implementing a lung cancer screening program.MATERIALS AND METHODS:One thousand sixty-five patients were screened from January 2014 to December 2014. These patients were screened on a low-dose CT screening protocol throughout Beaumont Health System. The American College of Radiology Lung Imaging Reporting and Data System (Lung-RADS) were used to assign the score for each patient. Screening eligibility criteria were based on the National Comprehensive Cancer Network guidelines. Downstream activity and revenue was determined after initial low-dose CT screening.RESULTS:At 1 year, 20 patients (1.6%) were diagnosed with lung cancer and another 15 patients were diagnosed with another form of cancer after screening. The median age, packs per day, and pack years smoked for all patients was 63, 1.0, and 39.0 years, respectively. Lung-RADS scores for all patients was 18% (1), 24.1% (2), 6.3% (3), and 5.4% (4). The net revenue for all activity after screening was $3.2 million.CONCLUSIONS:The establishment of a low-dose CT lung cancer screening program improved the ability to screen patients as demonstrated by the number of patients screened and those diagnosed with a malignancy. These findings were also consistent with the findings from the National Lung Screening Trial study.
Objective.To evaluate the impact of a multifaceted intervention on compliance with evidence-based therapies and ventilator-associated pneumonia (VAP) rates.Design.Collaborative cohort before-after study.Setting.Intensive care units (ICUs) predominantly in Michigan.Interventions.We implemented a multifaceted intervention to improve compliance with 5 evidence-based recommendations for mechanically ventilated patients and to prevent VAP. A standardized CDC definition of VAP was used and maintained at each site, and data on the number of VAPs and ventilator-days were obtained from the hospital's infection preventionists. Baseline data were reported and postimplementation data were reported for 30 months. VAP rates (in cases per 1,000 ventilator-days) were calculated as the proportion of ventilator-days per quarter in which patients received all 5 therapies in the ventilator care bundle. Two interventions to improve safety culture and communication were implemented first.Results.One hundred twelve ICUs reporting 3,228 ICU-months and 550,800 ventilator-days were included. The overall median VAP rate decreased from 5.5 cases (mean, 6.9 cases) per 1,000 ventilator-days at baseline to 0 cases (mean, 3.4 cases) at 16–18 months after implementation (P < .001) and 0 cases (mean, 2.4 cases) at 28-30 months after implementation (P < .001). Compared to baseline, VAP rates decreased during all observation periods, with incidence rate ratios of 0.51 (95% confidence interval, 0.41–0.64) at 16–18 months after implementation and 0.29 (95% confidence interval, 0.24–0.34) at 28–30 months after implementation. Compliance with evidence-based therapies increased from 32% at baseline to 75% at 16–18 months after implementation (P < .001) and 84% at 28–30 months after implementation (P < .001).Conclusions.A multifaceted intervention was associated with an increased use of evidence-based therapies and a substantial (up to 71%) and sustained (up to 2.5 years) decrease in VAP rates.
Objectives To evaluate the extent to which intensive care units participating in the initial Keystone ICU project sustained reductions in rates of catheter related bloodstream infections.Design Collaborative cohort study to implement and evaluate interventions to improve patients' safety.Setting Intensive care units predominantly in Michigan, USA.Intervention Conceptual model aimed at improving clinicians' use of five evidence based recommendations to reduce rates of catheter related bloodstream infections rates, with measurement and feedback of infection rates. During the sustainability period, intensive care unit teams were instructed to integrate this intervention into staff orientation, collect monthly data from hospital infection control staff, and report infection rates to appropriate stakeholders.Main outcome measures Quarterly rate of catheter related bloodstream infections per 1000 catheter days during the sustainability period (19-36 months after implementation of the intervention).Results Ninety (87%) of the original 103 intensive care units participated, reporting 1532 intensive care unit months of data and 300 310 catheter days during the sustainability period. The mean and median rates of catheter related bloodstream infection decreased from 7.7 and 2.7 (interquartile range 0.6-4.8) at baseline to 1.3 and 0 (0-2.4) at 16-18 months and to 1.1 and 0 (0.0-1.2) at 34-36 months post-implementation. Multilevel regression analysis showed that incidence rate ratios decreased from 0.68 (95% confidence interval 0.53 to 0.88) at 0-3 months to 0.38 (0.26 to 0.56) at 16-18 months and 0.34 (0.24-0.48) at 34-36 months post-implementation. During the sustainability period, the mean bloodstream infection rate did not significantly change from the initial 18 month post-implementation period (-1%, 95% confidence interval -9% to 7%).Conclusions The reduced rates of catheter related bloodstream infection achieved in the initial 18 month post-implementation period were sustained for an additional 18 months as participating intensive care units integrated the intervention into practice. Broad use of this intervention with achievement of similar results could substantially reduce the morbidity and costs associated with catheter related bloodstream infections.
Purpose: The aim of this study was to describe the design and lessons learned from implementing a large-scale patient safety collaborative and the impact of an intervention on teamwork climate in intensive care units (ICUs) across the state of Michigan.Materials and Methods: This study used a collaborative model for improvement involving researchers from the Johns Hopkins University and Michigan Health and Hospital Association. A quality improvement team in each ICU collected and submitted baseline data and implemented quality improvement interventions. Primary outcome measures were improvements in safety culture scores using the Teamwork Climate Scale of the Safety Attitudes Questionnaire (SAQ); 99 ICUs provided baseline SAQ data. Baseline performance for adherence to evidence-based interventions for ventilated patients is also reported. The intervention to improve safety culture was the comprehensive unit-based safety program. The r(wg) statistic measures the extent to which there is a group consensus.Results: Overall response rate for the baseline SAQ was 72%. Statistical tests confirmed that teamwork climate scores provided a valid measure of teamwork climate consensus among caregivers in an ICU, mean r(wg) was 0.840 (SD = 0.07). Teamwork climate varied significantly among ICUs at baseline (F-98, (5325) = 5.90, P <.001), ranging from 16% to 92% of caregivers in an ICU reporting good teamwork climate. A subset of 72 ICUs repeated the culture assessment in 2005, and a 2-tailed paired samples t test showed that teamwork climate improved from 2004 to 2005, t(71) = -2.921, P <.005. Adherence to using evidence-based interventions ranged from a mean of 25% for maintaining glucose at 110 mg/dL or less to 89% for stress ulcer prophylaxis.Conclusion: This study describes the first statewide effort to improve patient safety in ICUs. The use of the comprehensive unit-based safety program was associated with significant improvements in safety culture. This collaborative may serve as a model to implement feasible and methodologically rigorous methods to improve and sustain patient safety on a larger scale. (C) 2008 Elsevier Inc. All rights reserved.
BACKGROUND Catheter-related bloodstream infections occurring in the intensive care unit (ICU) are common, costly, and potentially lethal. METHODS We conducted a collaborative cohort study predominantly in ICUs in Michigan. An evidence-based intervention was used to reduce the incidence of catheter-related bloodstream infections. Multilevel Poisson regression modeling was used to compare infection rates before, during, and up to 18 months after implementation of the study intervention. Rates of infection per 1000 catheter-days were measured at 3-month intervals, according to the guidelines of the National Nosocomial Infections Surveillance System. RESULTS A total of 108 ICUs agreed to participate in the study, and 103 reported data. The analysis included 1981 ICU-months of data and 375,757 catheter-days. The median rate of catheter-related bloodstream infection per 1000 catheter-days decreased from 2.7 infections at baseline to 0 at 3 months after implementation of the study intervention (P< or =0.002), and the mean rate per 1000 catheter-days decreased from 7.7 at baseline to 1.4 at 16 to 18 months of follow-up (P<0.002). The regression model showed a significant decrease in infection rates from baseline, with incidence-rate ratios continuously decreasing from 0.62 (95% confidence interval [CI], 0.47 to 0.81) at 0 to 3 months after implementation of the intervention to 0.34 (95% CI, 0.23 to 0.50) at 16 to 18 months. CONCLUSIONS An evidence-based intervention resulted in a large and sustained reduction (up to 66%) in rates of catheter-related bloodstream infection that was maintained throughout the 18-month study period.