The international FCC study group published in 2019 a Conceptual Design Report for an electron-positron collider with a centre-of-mass energy from 90 to 365 GeV with a beam currents of up to 1.4 A per beam. The high beam current of this collider create challenging requirements on the injection chain and all aspects of the linac need to be carefully reconsidered and revisited, including the injection time structure. The entire beam dynamics studies for the full linac, damping ring and transfer lines are major activities of the injector complex design. A key point is that any increase of positron production and capture efficiency reduces the cost and complexity of the driver linac,
In this report, we reoptimised the CLIC positron source at all collision energy stages. Simulation, optimisation algorithm and results were all improved compared with previous studies. Two different target schemes were studied and compared in terms of the advantages and disadvantages. The spot size of the injected electron beam was also optimised to achieve a compromise between large positron yields and safe energy deposition. The matching device for the capture of positrons was simulated and optimised with both improved analytic and realistic field maps. Conical aperture and front and rear gaps of the matching device were also considered for the first time. The optimised positron source is expected to have the lowest cost.
In this report, we compared different matching device field profiles for the FCC-ee positron source. The matching device is used to capture positrons with magnetic field. A flux concentrator was designed with a conical inner chamber. A smaller aperture and a larger aperture were studied. An analytic field profile was also studied using an adiabatic formula. The peak field of the analytic profile as well as beam and target parameters was optimised to achieve a maximum positron yield. A safe energy deposition in the target was guaranteed by requiring a constraint on the deposited power and peak energy deposition density.
In this report, we proposed a new simple and efficient algorithm for positron source parameter optimisation, which is based on iterations of scan of free parameters in the simulation. The new algorithm is fast, simple and convincing since the results can be visually drawn and flexibly tuned, and it has an advantage that it can easily handle realistic parametric problems with more than one objective quantities to optimise. The optimisation of the main parameters of the CLIC positron source at the 380 GeV stage is presented as an example to demonstrate how the algorithm works.
The AWAKE Run 1 experiment achieved electron acceleration to 2 GeV using plasma wakefield acceleration driven by 400 GeV, self-modulated proton bunches from the CERN SPS. The Run 2c phase of the experiment aims to build on these results by demonstrating acceleration to ∼10 GeV while preserving the quality of the accelerated electron beam. To realize this, there will be an additional plasma cell, to separate the proton bunch self-modulation and the electron acceleration. A new 150 MeV beamline is required to transport and focus the witness electron beam to a beam size of several microns at the injection point. This specification is designed to preserve the beam emittance during acceleration, also requiring micron-level stability between the driver and witness beams. To facilitate these changes, the Run 1 proton transfer line will be reconfigured to shift the first plasma cell 40 m downstream. The Run 1 electron beamline will be adapted and used to inject electron bunches into the first plasma cell to seed the proton bunch self-modulation. Proposed adjustments to the proton transfer line and studies for the designs of the two electron transfer lines are detailed in this contribution.
The CERN Linear Electron Accelerator for Research (CLEAR) has now finished its second year of operation, providing a testbed for new accelerator technologies and a versatile radiation source. Hosting a varied experimental program, this beamline provides a flexible test facility for users both internal and external to CERN, as well as being an excellent accelerator physics training ground. The energy can be varied between 60 and 220 MeV, bunch length between 1 and 4 ps, bunch charge in the range 10 pC to 2 nC, and number of bunches in the range 1 to 200, at a repetition rate of 0.8 to 10 Hz. The status of the facility with an overview of the recent experimental results is presented.
Proton Beam-Driven Plasma Wakefield Accelerator (PBDPWFA) has been actively investigated at CERN within the AWAKE experiments to study the electron beam acceleration using plasma wake fields of the order of GV/m. In the AWAKE RUN 1 experiments an electron beam with an energy of 19 MeV and a bunch length of 2.2 ps rms has been used for the first demonstration of electron beam acceleration in the plasma wake fields. It has been observed that the energy gain of the electron beam is up to 2 GeV, and electron capture efficiency is few percent. Higher capturing efficiency and emittance preservation could be achieved by making the electron beam short enough to be injected only into the acceleration and focusing phase of the plasma wake fields. The electron accelerator needs to be upgraded for AWAKE RUN 2 experiments to obtain a bunch length less than 100 fs which corresponds to a quarter of the plasma wavelength. Planned electron beam parameters for the AWAKE RUN 2 are a beam charge of 100 pC, and a beam energy larger than 50 MeV. In this paper, we show the electron beam parameters for RUN 2, and the parameters of the transfer line such as Twiss parameters, beam envelope, and emittance.
A new CERN Linear Electron Accelerator for Research (named CLEAR) has been installed as a general-purpose user facility to study novel accelerating techniques, highgradient structures, instrumentation and irradiation experiments. CLEAR is a flexible accelerator that can provide high quality bunched electron beams with a wide range of beam parameters up to an energy of 220 MeV, offering several testing capabilities. Among all the potential applications, novel accelerating techniques, such as plasma acceleration and THz generation are considered. These applications require shorter bunches, down to the 100 fs level. This paper reports on beam dynamics studies and instrumentation tests to establish a bunch length of this order in CLEAR. The short bunches are generated using adiabatic bunching in the first accelerating structure. For bunch length diagnostic, CLEAR is equipped with a streak camera and a transverse deflecting cavity. Alternatively, a phase-scan of the last accelerating structure could be used as well to estimate the bunch length. The experimental results with respect to these different techniques are presented and compared with simulations.
The new Linear Electron Accelerator for Research (CLEAR) facility at CERN started its operation in fall 2017. CLEAR results from the conversion of the CALIFES beam line of the former CLIC Test Facility (CTF3) into a new testbed for general accelerator R&D and component studies for existing and possible future accelerator applications. CLEAR can provide a stable and reliable electron beam from 60 to 220 MeV in single or multi bunch configuration at 1.5 GHz. The experimental program includes studies for high gradient acceleration methods, e.g. for CLIC X-band and plasma technology, prototyping and validation of accelerator components, e.g. for the HL-LHC upgrade, and irradiation test capabilities for characterization of electronic components and for medical applications. An overview of the facility capabilities and a summary of the latest results will be presented.
The positron source of the CLIC has been optimized several years ago for the 3 TeV and 500 GeV c.o.m.-energy stages, and in a recent reoptimization the positron transmission efficiency from the tungsten target to damping ring entrance has been improved by a factor 2.5. Now, since the first stage of CLIC has been proposed to be at 380 GeV, new alternatives to the baseline design have been considered with the aim of improving the machine performance and its overall power efficiency, while possibly reducing the cost. For example, reducing the initial electron beam energy from 5 GeV to 3 GeV. In this paper, we present a start-to-end simulation environment which was setup for the whole positron source optimization. For the very first time a whole simulation including the positron creation in the hybrid tungsten targets, the adiabatic matching device, the pre-injector and the injector linacs has been put in place. First result of the new setup was to confirm of the transmission efficiency of the new improved baseline. Secondly, an ongoing optimization is promising even better results.
The AWAKE experiment aims to demonstrate preservation of injected electron beam quality during acceleration in proton-driven plasma waves. The short bunch duration required to correctly load the wakefield is challenging to meet with the current electron injector system, given the space available to the beamline. An LWFA readily provides short-duration electron beams with sufficient charge from a compact design, and provides a scalable option for future electron acceleration experiments at AWAKE. Simulations of a shock-front injected LWFA demonstrate a 43 TW laser system would be sufficient to produce the required charge over a range of energies beyond 100 MeV. LWFA beams typically have high peak current and large divergence on exiting their native plasmas, and optimisation of bunch parameters before injection into the proton-driven wakefields is required. Compact beam transport solutions are discussed.
In 2016, CLIC implementation working groups have started their reflection on how to finalize the CLIC design work in the different areas of the project, aiming for a technical design and an overall implementation plan for CLIC being available for the next European Strategy Update around 2019. One of the working groups has focused its attention on the Main Linac hardware, which has brought together the different competences of the study with the aim of producing an advanced set of specifications for the design, installation and operation of the CLIC module. As the fundamental unit for the construction of the Main Beam linac, the CLIC module needs to move from the existing prototypes exploring its performance into an advanced and functional unit where the full life cycle of the module is considered. The progress of the working group activity is summarized in this paper, with considerations on the requirements for the design of the next-phase CLIC module.
The drive beam of CLIC requires unusually high peak and average currents which is challenging for the electron source. As an alternative to the thermionic electron gun foreseen in the baseline design, a photoinjector option is under study at CERN using the PHIN photoinjector, which was designed for a bunch charge of 2.3 nC and 1200 ns train length. During operation with nominal train length in 2014, a large pressure increase in the vacuum system, attributed to a heating of the Faraday cup, caused a degradation of the photocathode. To overcome this problem a vacuum window has been installed to separate the Faraday cup from the rest of the vacuum system. In addition the train length has been further increased to 1600 ns to advance the beam parameters towards CLIC requirements. In this paper recent improved photocathode lifetime measurements carried out under these new conditions will be presented and compared with earlier measurements. Furthermore, the utilized Cs2Te cathode has been analyzed with X-ray Photoelectron Spectroscopy (XPS) before and after its usage in PHIN to get a better understanding of photocathode surface deterioration effects, which will also be discussed. 7th International Particle Accelerator Conference, Busan, Korea, 8 13 May 2016 Geneva, Switzerland 12 May 2016 CLIC – Note – 1107 STUDY OF THE PERFORMANCE OF Cs2Te CATHODES IN THE PHIN RF PHOTOINJECTOR USING LONG PULSE TRAINS C. Hessler, E. Chevallay, S. Doebert, V. Fedosseev, F. Friebel, I. Martini, M. Martyanov, H. Neupert, V. Nistor, M. Taborelli, CERN, Geneva, Switzerland Abstract The drive beam of CLIC requires unusually high peak and average currents which is challenging for the electron source. As an alternative to the thermionic electron gun foreseen in the baseline design, a photoinjector option is under study at CERN using the PHIN photoinjector, which was designed for a bunch charge of 2.3 nC and 1200 ns train length. During operation with nominal train length in 2014, a large pressure increase in the vacuum system, attributed to a heating of the Faraday cup, caused a degradation of the photocathode. To overcome this problem a vacuum window has been installed to separate the Faraday cup from the rest of the vacuum system. In addition the train length has been further increased to 1600 ns to advance the beam parameters towards CLIC requirements. In this paper recent improved photocathode lifetime measurements carried out under these new conditions will be presented and compared with earlier measurements. Furthermore, the utilized Cs2Te cathode has been analyzed with X-ray Photoelectron Spectroscopy (XPS) before and after its usage in PHIN to get a better understanding of photocathode surface deterioration effects, which will also be discussed.The drive beam of CLIC requires unusually high peak and average currents which is challenging for the electron source. As an alternative to the thermionic electron gun foreseen in the baseline design, a photoinjector option is under study at CERN using the PHIN photoinjector, which was designed for a bunch charge of 2.3 nC and 1200 ns train length. During operation with nominal train length in 2014, a large pressure increase in the vacuum system, attributed to a heating of the Faraday cup, caused a degradation of the photocathode. To overcome this problem a vacuum window has been installed to separate the Faraday cup from the rest of the vacuum system. In addition the train length has been further increased to 1600 ns to advance the beam parameters towards CLIC requirements. In this paper recent improved photocathode lifetime measurements carried out under these new conditions will be presented and compared with earlier measurements. Furthermore, the utilized Cs2Te cathode has been analyzed with X-ray Photoelectron Spectroscopy (XPS) before and after its usage in PHIN to get a better understanding of photocathode surface deterioration effects, which will also be discussed. INTRODUCTION The future e+ecollider CLIC [1] is based on a novel two-beam acceleration scheme consisting of two main beam linacs and one or two drive beam accelerators. The latter one generates the 12 GHz RF power needed to accelerate the main beam, and requires therefore high peak and average currents. In the baseline design, the drive beam is foreseen to be produced by a thermionic electron gun and a sub-harmonic bunching system [2], which however generates parasitic satellite pulses. These satellite pulses get lost during the acceleration process, which can create radiation issues and will reduce the system power efficiency. A potential solution for these issues could be to use a photoinjector as the drive beam source, which can produce the electron beam with the required time structure for the CLIC beam combination scheme and which eliminates the need of a bunching system, as it was demonstrated at the high-charge photoinjector PHIN [3]. PHIN is currently used to study the feasibility of the photoinjector option for the CLIC drive beam, but originally it was designed for the usage at the CLIC Test Facility 3 (CTF3). As a consequence, its parameter set differs from the CLIC requirements (Table 1) and considerable efforts have been made to improve its parameters in recent years [4] and are still on-going. The CLIC drive beam parameters, but also the PHIN parameters, are challenging for a photoinjector, especially the combination of high bunch charge, long trains and short bunch spacing. This unique parameter set has a strong impact on the photocathode lifetime and operation of PHIN was not always without problems in the past. During operation with the nominal train length e.g. in 2014 a large pressure increase in the vacuum system by one order of magnitude has been observed in conjunction with a short photocathode lifetime of 55 h (Fig. 1). It was assumed that the vacuum deterioration and resulting from that the cathode degradation was caused by a heating of an uncooled Faraday cup. Measures to overcome this problem and to prepare the system for even higher beam intensities and their effect on the photocathode performance are discussed in this paper. Table 1: PHIN and CLIC Design (and Achieved) Parameters