PURPOSE:To describe performance measurements, adaptations and time stability over 20 months of a diagnostic MR scanner for integration into MR-guided photon and particle radiotherapy. MATERIAL AND METHODS:For realization of MR-guided photon and particle therapy (MRgRT/MRgPT), a 1.5 T MR scanner was installed at the Heidelberg Ion Beam Therapy Center. To integrate MRI into the treatment process, a flat tabletop and dedicated coil holders for flex coils were used, which prevent deformation of the patient external contour and allow for the use of immobilization tools for reproducible positioning. The signal-to-noise ratio (SNR) was compared for the diagnostic and therapy-specific setup using the flat couch top and flexible coils for the a) head & neck and b) abdominal region as well as for different bandwidths and clinical pulse sequences. Additionally, a quality assurance (QA) protocol with monthly measurements of the ACR phantom and measurement of geometric distortions for a large field-of-view (FOV) was implemented to assess the imaging quality parameters of the device over the course of 20 months. RESULTS:The SNR measurements showed a decreased SNR for the RT-specific as compared to the diagnostic setup of (a) 26% to 34% and (b) 11% to 33%. No significant bandwidth dependency for this ratio was found. The longitudinal assessment of the image quality parameters with the ACR and distortion phantom confirmed the long-term stability of the MRI device. CONCLUSION:A diagnostic MRI was commissioned for use in MR-guided particle therapy. Using a radiotherapy specific setup, a high geometric accuracy and signal homogeneity was obtained after some adaptions and the measured parameters were shown to be stable over a period of 20 months.
Objective. This study investigates the effects of various training protocols on enhancing the precision of MRI-only Pseudo-CT generation for radiation treatment planning and adaptation in head & neck cancer patients. It specifically tackles the challenge of differentiating bone from air, a limitation that frequently results in substantial deviations in the representation of bony structures on Pseudo-CT images. Approach. The study included 25 patients, utilizing pre-treatment MRI-CT image pairs. Five cases were randomly selected for testing, with the remaining 20 used for model training and validation. A 3D U-Net deep learning model was employed, trained on patches of size 643 with an overlap of 323. MRI scans were acquired using the Dixon gradient echo (GRE) technique, and various contrasts were explored to improve Pseudo-CT accuracy, including in-phase, water-only, and combined water-only and fat-only images. Additionally, bone extraction from the fat-only image was integrated as an additional channel to better capture bone structures on Pseudo-CTs. The evaluation involved both image quality and dosimetric metrics. Main results. The generated Pseudo-CTs were compared with their corresponding registered target CTs. The mean absolute error (MAE) and peak signal-to-noise ratio (PSNR) for the base model using combined water-only and fat-only images were 19.20 +/- 5.30 HU and 57.24 +/- 1.44 dB, respectively. Following the integration of an additional channel using a CT-guided bone segmentation, the model's performance improved, achieving MAE and PSNR of 18.32 +/- 5.51 HU and 57.82 +/- 1.31 dB, respectively. The measured results are statistically significant, with a p-value < 0.05. The dosimetric assessment confirmed that radiation treatment planning on Pseudo-CT achieved accuracy comparable to conventional CT. Significance. This study demonstrates improved accuracy in bone representation on Pseudo-CTs achieved through a combination of water-only, fat-only and extracted bone images; thus, enhancing feasibility of MRI-based simulation for radiation treatment planning.
This work presents an experimental dosimetric evaluation of raster-scanning particle beam delivery during simultaneous in-beam magnetic resonance (MR) imaging. Using an open MR scanner at an experimental treatment room, radiochromic film comparisons for protons, helium and carbon ions, each with and without simultaneous in-beam cine MR imaging, yielded 2D gamma pass rates >= 98.8 % for a 3 % / 1.5 mm criterion, and >= 99.9 % for 5 % / 1.5 mm. These results constitute a first experimental confirmation that time varying magnetic fields of MR gradients do not result in clinically relevant additional dose perturbations.
Objective. Magnetic resonance (MR) images free of artefacts are of pivotal importance for MR-guided ion radiotherapy. This study investigates MR image quality for simultaneous irradiation in an experimental setup using phantom imaging as well as in-vivo imaging. Observed artefacts are described within the study and their cause is investigated with the goal to find conclusions and solutions for potential future hybrid devices. Approach. An open MR scanner with a field strength of 0.25 T has been installed in front of an ion beamline. Simultaneous magnetic resonance imaging and irradiation using raster scanning were performed to analyze image quality in dedicated phantoms. Magnetic field measurements were performed to assist the explanation of observed artifacts. In addition, in-vivo images were acquired by operating the magnets for beam scanning without transporting a beam. Main Results. The additional frequency component within the isocenter caused by the fringe field of the horizontal beam scanning magnet correlates with the amplitude and frequency of the scanning magnet steering and can cause ghosting artifacts in the images. These are amplified with high currents and fast operating of the scanning magnet. Applying a real-time capable pulse sequence in-vivo revealed no ghosting artifacts despite a continuously changing current pattern and a clinical treatment plan activation scheme, suggesting that the use of fast imaging is beneficial for the aim of creating high quality in-beam MR images. This result suggests, that the influence of the scanning magnets on the MR acquisition might be of negligible importance and does not need further measures like extensive magnetic shielding of the scanning magnets. Significance. Our study delimited artefacts observed in MR images acquired during simultaneous raster scanning ion beam irradiation. The application of a fast pulse sequence showed no image artefacts and holds the potential that online MR imaging in future hybrid devices might be feasible.
Background Particle therapy makes a noteworthy contribution in the treatment of tumor diseases. In order to be able to irradiate from different angles, usually expensive, complex and large gantries are used. Instead rotating the beam via a gantry, the patient itself might be rotated. Here we present tolerance and compliance of volunteers for a fully-enclosed patient rotation system in a clinical magnetic resonance (MR)-scanner for potential use in MR-guided radiotherapy, conducted within a prospective evaluation study. Method A patient rotation system was used to simulate and perform magnetic resonance imaging (MRI)-examinations with 50 volunteers without an oncological question. For 20 participants, the MR-examination within the bore was simulated by introducing realistic MRI noise, whereas 30 participants received an examination with image acquisition. Initially, body parameters and claustrophobia were assessed. The subjects were then rotated to different angles for simulation (0°, 45°, 90°, 180°) and imaging (0°, 70°, 90°, 110°). At each angle, anxiety and motion sickness were assessed using a 6-item State-Trait-Anxiety-Inventory (STAI-6) and a modified Motion Sickness Assessment Questionnaire (MSAQ). In addition, general areas of discomfort were evaluated. Results Out of 50 subjects, three (6%) subjects terminated the study prematurely. One subject dropped out during simulation due to nausea while rotating to 45°. During imaging, further two subjects dropped out due to shoulder pain from positioning at 90° and 110°, respectively. The average result for claustrophobia (0 = no claustrophobia to 4 = extreme claustrophobia) was none to light claustrophobia (average score: simulation 0.64 ± 0.33, imaging 0.51 ± 0.39). The mean anxiety scores (0% = no anxiety to 100% = maximal anxiety) were 11.04% (simulation) and 15.82% (imaging). Mean motion sickness scores (0% = no motion sickness to 100% = maximal motion sickness) of 3.5% (simulation) and 6.76% (imaging) were obtained across all participants. Conclusion Our study proves the feasibility of horizontal rotation in a fully-enclosed rotation system within an MR-scanner. Anxiety scores were low and motion sickness was only a minor influence. Both anxiety and motion sickness showed no angular dependency. Further optimizations with regard to immobilization in the rotation device may increase subject comfort.
This study investigates the LET-dependence of dose measurements performed with a nanocomposite Fricke gel (NC-FG) upon irradiation with carbon ion beams to address the problem of quenching of gel dosimeters in high-LET particle therapy. The preparation of the NC-FG in a simple gel preparation device was performed for atmospheric and anoxic environmental conditions and two different container materials. Irradiation was performed with carbon ion beams at energies of 133.39MeV/u or 194.87MeV/u, complemented by a modulated 10 mm carbon ion spread-out Bragg peak (SOBP) irradiation. The R1 profiles obtained from the MRI readout were compared to the treatment planning system and a 2D-ionisation chamber array measurement performed for the mono-energetic and SOBP irradiations, respectively. For different dose levels, no difference in the gel response was obtained for the 3D-printed plastic containers, while the glass vials exhibited a linear dose response. Additional use of the glove box changes produced similar results. For both the mono-energetic and the SOBP irradiation, a linear dose response without quenching was observed. For depths ranging up to the Bragg peak position, the mono-energetic profiles deviated by less than ± 15% from the planned dose distribution, excluding the lowest entrance surface dose (ESD). For the SOBP profiles, the deviation from the measured dose distribution was less than ± 10% for depths between 20 mm and 33 mm. This study presents a LET-independent measurement of mono-energetic carbon ion Bragg peaks and, for the first time, a LET-independent measurement of a carbon ion SOBP with the NC-FG prepared in a simple gel preparation device under atmospheric conditions. The NC-FG provides a possible solution for 3D dosimetry in carbon ion radiotherapy.
Modern radiotherapy delivers highly conformal dose distributions to irregularly shaped target volumes while sparing the surrounding normal tissue. Due to the complex planning and delivery techniques, dose verification and validation of the whole treatment workflow by end-to-end tests became much more important and polymer gel dosimeters are one of the few possibilities to capture the delivered dose distribution in 3D. The basic principles and formulations of gel dosimetry and its evaluation methods are described and the available studies validating device-specific geometrical parameters as well as the dose delivery by advanced radiotherapy techniques, such as 3D-CRT/IMRT and stereotactic radiosurgery treatments, the treatment of moving targets, online-adaptive magnetic resonance-guided radiotherapy as well as proton and ion beam treatments, are reviewed. The present status and limitations as well as future challenges of polymer gel dosimetry for the validation of complex radiotherapy techniques are discussed.
Stopping power ratio (SPR) maps are needed for dose deposition calculations and are typically estimated from single energy CT (SECT) in clinical routine. SECT-based SPR conversion leads to large variability due to the one-to-one relationship assumed by the conversion method. Dual-energy CT (DECT) involving the acquisition of two energy spectra captures both material-specific information and tissue characterization which is essential for an accurate SPR map conversion. The goal of this study is to train a U-Net architecture to generate pseudo-SPR map from MRI (Dixon) using a DECT-converted SPR map. The model performance was validated using Head & Neck cohort of 16 patients with paired MRI and SPR maps. The proposed solution achieved a mean absolute error (MAE) and peak-signal-to-noise-ratio (PSNR) of 19.41 ± 8.67 HU and 58.76 ± 2.17 dB respectively for all test cases. From observation, the sequential incorporation of different Dixon MRI images such as fat-suppressed and water-suppressed yielded an accurate pseudo-SPR map which is comparable to its corresponding target SPR map. Furthermore, bone delineation integrated as additional channel to Dixon MRI sequence demonstrated an enhanced bone identification on predicted pseudo-SPR map. As future direction, we would like to extend this approach to a clinical SPR map which will enable dosimetric analysis of clinical target volume (CTV) to be possible in treatment planning application for ion beam therapy.
Background and purpose:Magnetic Resonance Imaging (MRI) is widely used in oncology for tumor staging, treatment response assessment, and radiation therapy (RT) planning. This study proposes a framework for automatic optimization of MRI sequences based on pulse sequence parameter sets (SPS) that are directly applied on the scanner, for application in RT planning.Materials and methods:A phantom with seven in-house fabricated contrasts was used for measurements. The proposed framework employed a derivative-free optimization algorithm to repeatedly update and execute a parametrized sequence on the MR scanner to acquire new data. In each iteration, the mean-square error was calculated based on the clinical application. Two clinically relevant optimization goals were pursued: achieving the same signal and therefore contrast as in a target image, and maximizing the signal difference (contrast) between specified tissue types. The framework was evaluated using two optimization methods: a covariance matrix adaptation evolution strategy (CMA-ES) and a genetic algorithm (GA).Results:The obtained results demonstrated the potential of the proposed framework for automatic optimization of MRI sequences. Both CMA-ES and GA methods showed promising results in achieving the two optimization goals, however, CMA-ES converged much faster as compared to GA.Conclusions:The proposed framework enables for automatic optimization of MRI sequences based on SPS that are directly applied on the scanner and it may be used to enhance the quality of MRI images for dedicated applications in MR-guided RT.
Purpose. Improvements in image-guided radiotherapy (IGRT) enable accurate and precise treatment of moving tumors in the abdomen while simultaneously sparing healthy tissue. However, the lack of validation tools for newly developed MR-guided radiotherapy hybrid devices such as the MR-Linac is an open issue. This study presents a custom developed abdominal phantom with respiratory organ motion and multimodal imaging contrast to perform end-to-end tests for IGRT treatment planning scenarios.Methods. The abdominal phantom contains deformable and anatomically shaped liver and kidney models made of Ni-DTPA and KCl-doped agarose mixtures that can be reproducibly positioned within the phantom. Organ models are wrapped in foil to avoid ion exchange with the surrounding agarose and to provide stable T1 and T2 relaxation times as well as HU numbers. Breathing motion is realized by a diaphragm connected to an actuator that is hydraulically controlled via a programmable logic controller. With this system, artificial and patient-specific breathing patterns can be carried out. In 1.5 T magnetic resonance imaging (MRI), diaphragm, liver and kidney motion was measured and compared to the breathing motion of a healthy male volunteer for different breathing amplitudes including shallow, normal and deep breathing.Results. The constructed abdominal phantom demonstrated organ-equivalent intensity values in CT as well as in MRI. T1-weighted (T1w) and T2-weighted (T2w) relaxation times for 1.5 T and CT numbers were 552.9 ms, 48.2 ms and 48.8 HU (liver) as well as 950.42 ms, 79 ms and 28.2 HU (kidney), respectively. These values were stable for more than six months. Extracted breathing motion from a healthy volunteer revealed a liver to diaphragm motion ratio (LDMR) of 64.4% and a kidney to diaphragm motion ratio (KDMR) of 30.7%. Well-comparable values were obtained for the phantom (LDMR: 65.5%, KDMR: 27.5%).Conclusions. The abdominal phantom demonstrated anthropomorphic T1 and T2 relaxation times as well as HU numbers and physiological motion pattern in MRI and CT. This allows for wide use in the validation of IGRT including MRgRT.
The implementation of new image-guided radiotherapy (IGRT) treatment techniques requires the development of new quality assurance (QA) methods including geometric and dosimetric validation of the applied dose in 3D. Polymer gels (PG) provide a promising tool to perform such tests. However, to be used in a large variety of clinical applications, the PG must be flexibly applicable. In this work, we present a variety of phantoms used in clinical routine to perform both hardware and workflow tests in IGRT. This includes the validation of isocenter accuracy in magnetic resonance (MR)-guided RT (MRgRT) and end-to-end tests of online adaptive treatment techniques for inter- and intra-fraction motion management in IGRT. The phantoms are equipped with one or more PG containers of different materials including 3D printed containers to allow for 3D dosimetry in arbitrarily shaped structures. The proposed measurement techniques and phantoms provide a flexible application and show a clear benefit of PG for 3D dosimetry in combination with end-to-end tests in many clinical QA applications.
Objective. In MR-guided radiotherapy (MRgRT) for prostate cancer treatments inter-fractional anatomy changes such as bladder and rectum fillings may be corrected by an online adaption of the treatment plan. To clinically implement such complex treatment procedures, however, specific end-to-end tests are required that are able to validate the overall accuracy of all treatment steps from pre-treatment imaging to dose delivery. Approach. In this study, an end-to-end test of a fractionated and online adapted MRgRT prostate irradiation was performed using the so-called ADAM-PETer phantom. The phantom was adapted to perform 3D polymer gel (PG) dosimetry in the prostate and rectum. Furthermore, thermoluminescence detectors (TLDs) were placed at the center and on the surface of the prostate for additional dose measurements as well as for an external dose renormalization of the PG. For the end-to-end test, a total of five online adapted irradiations were applied in sequence with different bladder and rectum fillings, respectively. Main results. A good agreement of measured and planned dose was found represented by high γ -index passing rates ( 3 % / 3 mm criterion) of the PG evaluation of 98.9 % in the prostate and 93.7 % in the rectum. TLDs used for PG renormalization at the center of the prostate showed a deviation of − 2.3 % . Significance. The presented end-to-end test, which allows for 3D dose verification in the prostate and rectum, demonstrates the feasibility and accuracy of fractionated and online-adapted prostate irradiations in presence of inter-fractional anatomy changes. Such tests are of high clinical importance for the commissioning of new image-guided treatment procedures such as online adaptive MRgRT.