Objective. Electroencephalography (EEG) data is derived by sampling continuous neurological time series signals. In order to prepare EEG signals for machine learning, the signal must be divided into manageable segments. The current naive approach uses arbitrary fixed time slices, which may have limited biological relevance because brain states are not confined to fixed intervals. We investigate whether adaptive segmentation methods are beneficial for machine learning EEG analysis. Approach. We introduce a novel adaptive segmentation method, CTXSEG, that creates variable-length segments based on statistical differences in the EEG data and propose ways to use them with modern machine learning approaches that typically require fixed-length input. We assess CTXSEG using controllable synthetic data generated by our novel signal generator CTXGEN. We validate on a real-world use case by replacing fixed-length segmentation in the preprocessing step of a typical EEG machine learning pipeline for seizure detection, and offer guidance on how application may be extended to other problem domains. Main results. We found that using CTXSEG to prepare EEG data improves seizure detection performance compared to fixed-length approaches when evaluated using a standardized framework, without modifying the machine learning method, and requires fewer segments. Significance. This work demonstrates that adaptive segmentation with CTXSEG can be readily applied to modern machine learning approaches, with potential to improve performance. It is a promising alternative to fixed-length segmentation for signal preprocessing and should be considered as part of the standard preprocessing repertoire in EEG machine learning applications.
Individuals with severe physical disabilities often experience diminished quality of life stemming from limited ability to engage with their surroundings. Brain-Computer Interface (BCI) technology aims to bridge this gap by enabling direct technology interaction. However, current BCI systems require invasive procedures, such as craniotomy or implantation of electrodes through blood vessels, posing significant risks to patients. Sub-scalp electroencephalography (EEG) offers a lower risk alternative. This study investigates the signal quality of sub-scalp EEG recordings from various depths in a sheep model, and compares results with other methods: ECoG and endovascular arrays. A computational model was also constructed to investigate the factors underlying variations in electrode performance. We demonstrate that peg electrodes placed within the sub-scalp space can achieve visual evoked potential signal-to-noise ratios (SNRs) approaching that of ECoG. Endovascular arrays exhibited SNR comparable to electrodes positioned on the periosteum. Furthermore, sub-scalp recordings captured high gamma neural activity, with maximum bandwidth ranging from 120 Hz to 180 Hz depending on electrode depth. These findings support the use of sub-scalp EEG for BCI applications, and provide valuable insights for future sub-scalp electrode design. This data lays the groundwork for human trials, ultimately paving the way for chronic, in-home BCIs that empower individuals with physical disabilities.
Thermo-mechanical fatigue (TMF) is a complex damage mechanism considered to be one of the key issues limiting the service lives of hot section components in a gas turbine engine. Turbine blades and nozzle guide vanes are particularly susceptible to this form of material degradation, which results from the simultaneous cycling of mechanical and thermal loads. In this research, a series of TMF tests were undertaken on a single crystal nickel-based superalloy, CMSX-4 under a variety of phase angles and a thermal cycle of 550-1050 degrees C, to holistically understand the evolving damage mechanisms that can occur under the various loading conditions. The generated data has shown that for the strain ranges tested, fatigue life is significantly affected by the employed phase angle. Furthermore, the length of time that the material is exposed to elevated temperature has a substantial influence on the material's microstructure, and thus, the dominant mode of damage that occurs.
Recent work has shown the ability to record neural behaviour in pre-clinical studies from an endovascular location for over a year. Previous work on stimulating neural tissue from an endovascular location has also shown motor-evoked responses in sheep. However, endovascular stimulation requires high currents and can result in electrode degradation. This study aimed to modify an endovascular electrode to increase its charge injection capacity for efficacious neural stimulation. The platinum endovascular electrode was modified with platinum black and characterised by electrochemical and microscopic techniques. The stability of the electrode coating was assessed after a 7-day continuous stimulation paradigm. Modelling of the neural activating function was performed for central and peripheral neural anatomy with both electrode materials. Platinum black coatings had a substantially larger electroactive area than uncoated platinum. This resulted in increased electrode admittance, charge storage capacity and charge injection capacity while reducing the total impedance at 10 Hz and polarisation voltage. The coated electrode was comparatively more electrochemically stable than uncoated platinum following the 7-day continuous stimulation protocol. Modelling of the neural activating function indicated a substantial increase in the electrode-neuron distance which could be safely stimulated using platinum black coated electrodes. By comparison of electrochemical response with neural modelling, we have demonstrated the feasibility of safe stimulation of neural tissue using an endovascular neural interface, opening the possibility of a new, minimally invasive neural stimulation paradigm.
Objective.There is limited work investigating brain-computer interface (BCI) technology in people with multiple sclerosis (pwMS), a neurodegenerative disorder of the central nervous system. Present work is limited to recordings at the scalp, which may be significantly altered by changes within the cortex due to volume conduction. The recordings obtained from the sensors, therefore, combine disease-related alterations and task-relevant neural signals, as well as signals from other regions of the brain that are not relevant. The current study aims to unmix signals affected by multiple sclerosis (MS) progression and BCI task-relevant signals using estimated source activity to improve classification accuracy.Approach.Data was collected from eight participants with a range of MS severity and ten neurotypical participants. This dataset was used to report the classification accuracy of imagined movements of the hands and feet at the sensor-level and the source-level in the current study.K-means clustering of equivalent current dipoles was conducted to unmix temporally independent signals. The location of these dipoles was compared between MS and control groups and used for classification of imagined movement. Linear discriminant analysis classification was performed at each time-frequency point to highlight differences in frequency band delay.Main Results.Source-level signal acquisition significantly improved decoding accuracy of imagined movement vs rest and movement vs movement classification in pwMS and controls. There was no significant difference found in alpha (7-13 Hz) and beta (13-30 Hz) band classification delay between the neurotypical control and MS group, including imagery of limbs with weakness or paralysis.Significance.This study is the first to demonstrate the advantages of source-level analysis for BCI applications in pwMS. The results highlight the potential for enhanced clinical outcomes and emphasize the need for longitudinal studies to assess the impact of MS progression on BCI performance, which is crucial for effective clinical translation of BCI technology.
Multiple Sclerosis (MS) is a heterogeneous autoimmune-mediated disorder affecting the central nervous system, commonly manifesting as fatigue and progressive limb impairment. This can significantly impact quality of life due to weakness or paralysis in the upper and lower limbs. A Brain-Computer Interface (BCI) aims to restore quality of life through control of an external device, such as a wheelchair. However, the limited BCI research in people with MS is insufficient. The current study aims to expand on the current MS-BCI literature by highlighting the feasibility of decoding MS imagined movement. We collected electroencephalography (EEG) data from eight participants with various symptoms of MS and ten neurotypical control participants. Participants made imagined movements of the hands and feet as directed by a go no-go protocol. Binary regularised linear discriminant analysis was used to classify imagined movement at individual time-frequency points. The frequency bands which provided the maximal accuracy, and the associated latency, were compared. In all MS participants, the classification algorithm achieved above 70% accuracy in at least one imagined movement vs. rest classification and most movement vs. movement classifications. There was no significant difference between classification of limbs with weakness or paralysis to neurotypical controls. Both the MS and control groups possessed decodable information within the alpha (7-13 Hz) and beta (16-30 Hz) bands at similar latency. This study is the first to demonstrate the feasibility of decoding imagined movements in people with MS. As an alternative to the P300 response, motor imagery-based control of a BCI may also be combined with existing motor imagery therapy to supplement MS rehabilitation. These promising results merit further long term BCI studies to investigate the effect of MS progression on classification performance.
Current brain-computer interfaces (BCI) face limitations in signal acquisition. While sub-scalp EEG offers a potential solution, existing devices prioritize chronic seizure monitoring and lack features suited for BCI applications. This work addresses this gap by outlining key specifications for sub-scalp BCI devices, focusing on channel count, sampling rate, power efficiency, and form factor. We present the Set-And-Forget EEG (SAFE) system, a custom-built amplifier and wireless transmitter meeting these criteria. This compact (12x12 mm), six-channel device offers 1024 Hz sampling and Bluetooth Low Energy data transmission. Validation using generated sinusoids and electrocorticography recordings of visual evoked potentials in sheep models demonstrated low noise recording. Future animal studies will assess sub-scalp EEG signal quality for BCI applications. This data lays the groundwork for human trials, ultimately paving the way for chronic, in-home BCIs that empower individuals with physical disabilities.
BACKGROUND:Multiple Sclerosis (MS) can be a severely disabling condition that leads to various neurological symptoms. A Brain-Computer Interface (BCI) may substitute some lost function; however, there is a lack of BCI research in people with MS. Present BCI designs have also overlooked the unique pathological changes associated with MS and have not considered needs of users within their home environments. To progress this research area effectively and efficiently, we aimed to evaluate user needs and assess the feasibility and user-centric requirements of a BCI for people with MS. We hypothesised that (i) people with MS would be interested in adopting BCI technology and (ii) those with reduced independence would prefer a higher-performing invasive BCI. METHODS:We conducted an online survey of people with MS to describe user preferences and establish the initial steps of user-centred design. The survey aimed to understand their interest in BCI applications, bionic applications, device preferences, and development considerations and related these to symptoms and assistance needs. RESULTS:We demonstrated widespread interest for BCI applications in all stages of MS, with a preference for a non-invasive (n = 12) or minimally invasive (n = 15) BCI over carer assistance (n = 6). Descriptive analysis indicated that level of independence did not influence preference towards the higher performing but highly invasive BCI. CONCLUSIONS:The needs of end users reported in this study are crucial for efficient development of BCI systems that can be effectively translated into the home environment. Considering the potential to enhance independence and quality of life for people living with MS, the results emphasise the importance of user-centred design for future advancement of BCIs that account for the unique pathological changes associated with MS.
Objective.Implantable neural interfaces enable recording of high-quality brain signals that can improve our understanding of brain function. This work examined the feasibility of using a minimally invasive endovascular neural interface (ENI) to record interpretable cortical activity from the visual cortex.Approach. A sheep model (n= 5) was used to record and decode visually evoked potentials from the cortex both with an ENI and a subdural electrode grid. Sets of distinct experimental visual stimuli were presented to attempt decoding from the recorded cortical potentials, using perceptual categories of colour, contrast, movement direction orientation, spatial frequency and temporal frequency. Decoding performances are presented as accuracy scores from K-fold cross-validation of a stratified random forest classification model. The study compared the signal quality and decoding performance between the ENI and electrocorticography (ECoG) electrodes.Main results. Recordings from the ENI array resulted in lower decoding performances than the ECoG array, but the classification scores were significantly above chance in the stimuli categories of colour, contrast, direction and temporal frequency. This study is the first report of visually evoked neural activity using a minimally-invasive ENI.Significance. Overall, the results show that implantable macro-electrodes yield sufficient neural signal definition to discern primary visual percepts, using both endo-vascular and intracranial surgical placements.
Download This Paper Open PDF in Browser Add Paper to My Library Share: Permalink Using these links will ensure access to this page indefinitely Copy URL Copy DOI
The endovascular neural interface provides an appealing minimally invasive alternative to invasive brain electrodes for recording and stimulation. However, stents placed in blood vessels have long been known to affect blood flow (haemodynamics) and lead to neointimal growth within the blood vessel. Both the stent elements (struts and electrodes) and blood vessel wall geometries can affect the mechanical environment on the blood vessel wall, which could lead to unfavourable vascular remodelling after stent placement. With increasing applications of stents and stent-like neural interfaces in venous blood vessels in the brain, it is necessary to understand how stents affect blood flow and tissue growth in veins. We explored the haemodynamics of a stent-mounted neural interface in a blood vessel model. Results indicated that blood vessel deformation and tapering caused a substantial change to the lumen geometry and the haemodynamics. The neointimal proliferation was evaluated in sheep implanted with an endovascular neural interface. Analysis showed a negative correlation with the mean Wall Shear Stress pattern. The results presented here indicate that the optimal stent oversizing ratio must be considered to minimise the haemodynamic impact of stenting.
Noninvasive augmented-reality (AR) brain-computer interfaces (BCIs) that use steady-state visually evoked potentials (SSVEPs) typically adopt a fully-autonomous goal-selection framework to control a robot, where automation is used to compensate for the low information transfer rate of the BCI. This scheme improves task performance but users may prefer direct control (DC) of robot motion. To provide users with a balance of autonomous assistance and manual control, we developed a shared control (SC) system for continuous control of robot translation using an SSVEP AR-BCI, which we tested in a 3D reaching task. The SC system used the BCI input and robot sensor data to continuously predict which object the user wanted to reach, generated an assistance signal, and regulated the level of assistance based on prediction confidence. Eighteen healthy participants took part in our study and each completed 24 reaching trials using DC and SC. Compared to DC, SC significantly improved (paired two-tailed t-test, Holm-corrected α<0.05) mean task success rate (p<0.0001, μ=36.1%, 95% CI [25.3%, 46.9%]), normalised reaching trajectory length (p<0.0001, μ=-26.8%, 95% CI [-36.0%, -17.7%]), and participant workload (p=0.02, μ=-11.6, 95% CI [-21.1, -2.0]) measured with the NASA Task Load Index. Therefore, users of SC can control the robot effectively, while experiencing increased agency. Our system can personalise assistive technology by providing users with the ability to select their preferred level of autonomous assistance.
Objective. Electrical stimulation of peripheral nerves has long been a treatment option to restore impaired neural functions that cannot be restored by conventional pharmacological therapies. Endovascular neurostimulation with stent-mounted electrode arrays is a promising and less invasive alternative to traditional implanted electrodes, which typically require invasive implantation surgery. In this study, we investigated the feasibility of endovascular stimulation of the femoral nerve using a stent-mounted electrode array and compared its performance to that of a commercially available pacing catheter. Approach. In acute animal experiments, a pacing catheter was implanted unilaterally in the femoral artery to stimulate the femoral nerve in a bipolar configuration. Electromyogram of the quadriceps and electroneurogram of a distal branch of the femoral nerve were recorded. After retrieval of the pacing catheter, a bipolar stent-mounted electrode array was implanted in the same artery and the recording sessions were repeated. Main Results. Stimulation of the femoral nerve was feasible with the stent-electrode array. Although the threshold stimulus intensities required with the stent-mounted electrode array (at 100-500 mu s increasing pulse width, 2.17 +/- 0.87 mA-1.00 +/- 0.11 mA) were more than two times higher than the pacing catheter electrodes (1.05 +/- 0.48 mA-0.57 +/- 0.28 mA), we demonstrated that, by reducing the stimulus pulse width to 100 mu s, the threshold charge per phase and charge density can be reduced to 0.22 +/- 0.09 mu C and 24.62 +/- 9.81 mu C cm-2, which were below the tissue-damaging limit, as defined by the Shannon criteria. Significance. The present study is the first to report in vivo feasibility and efficiency of peripheral nerve stimulation using an endovascular stent-mounted electrode array.
Objective.Endovascular neuromodulation has attracted substantial interest in recent years as a minimally invasive approach to treat neurological disorders. In this study, we investigated with a computational model the feasibility of stimulating peripheral nerves with an endovascular stent-mounted electrode array.Approach.Anatomically realistic FEM models were constructed for the pudendal and vagal neurovascular bundles. The electromagnetic fields generated from electrical stimuli were computed using Sim4Life NEURON models to predict dynamic axonal responses.Main results.The models predict that the stimulation thresholds of the endovascular stent-electrode array configurations tested are comparable to that of ring electrodes and are dependent on the inter-electrode distance and orientation of the device. Arranging multiple electrodes along the longitudinal axis of the nerve lowers surface charge density without sacrificing axon recruitment, whereas arranging electrodes along the circumference of the blood vessel reduces the risk of misalignment but lowers axon recruitment.Significance.Overall, this study predicts that the endovascular stent-electrode array is a feasible stimulation option for peripheral nerves, and the electrode array can be flexibly optimized to achieve the lowest stimulation threshold.
Minimally invasive intravascular electroencephalography (ivEEG) signals are a promising tool for developing clinically feasible brain-computer interfaces (BCIs) that restore communication and motor functions in paralyzed patients. However, current ivEEG techniques can only record signals from the superior sagittal sinus (SSS), making it challenging to record motor responses related to hand and mouth movements from brain regions distant from the SSS, despite their critical role in BCIs. Here, using micro intravascular electrodes, ivEEGs recorded from the cortical or deep veins of eight pigs could measure cortical activities with greater signal power and better spatial resolution than those recording in the SSS, thus allowing mapping of the sensorimotor and visual functional areas. Additionally, electrical stimulation in the cortical vein between the micro intravascular electrodes induced muscle contractions contralateral to the stimulated area in five anesthetized pigs. These results demonstrate that ivEEG using micro intravascular electrodes is a promising tool for developing BCIs. ### Competing Interest Statement The authors have declared no competing interest.
Brain-computer interfaces (BCI) have the potential to improve the quality of life for persons with paralysis. Sub-scalp EEG provides an alternative BCI signal acquisition method that compromises between the limitations of traditional EEG systems and the risks associated with intracranial electrodes, and has shown promise in long-term seizure monitoring. However, sub-scalp EEG has not yet been assessed for suitability in BCI applications. This study presents a preliminary comparison of visual evoked potentials (VEPs) recorded using sub-scalp and endovascular stent electrodes in a sheep. Sub-scalp electrodes recorded comparable VEP amplitude, signal-to-noise ratio and bandwidth to the stent electrodes.Clinical relevance—This is the first study to report a comparision between sub-scalp and stent electrode array signals. The use of sub-scalp EEG electrodes may aid in the long-term use of brain-computer interfaces.
This work evaluates the feasibility of using a source level Brain-Computer Interface (BCI) for people with Multiple Sclerosis (MS). Data used was previously collected EEG of eight participants (one participant with MS and seven neurotypical participants) who performed imagined movement of the right and left hand. Equivalent current dipole cluster fitting was used to assess related brain activity at the source level and assessed using dipole location and power spectrum analysis. Dipole clusters were resolved within the motor cortices with some notable spatial difference between the MS and control participants. Neural sources that generate motor imagery originated from similar motor areas in the participant with MS compared to the neurotypical participants. Power spectral analysis indicated a reduced level of alpha power in the participant with MS during imagery tasks compared to neurotypical participants. Power in the beta band may be used to distinguish between left and right imagined movement for users with MS in BCI applications.Clinical Relevance— This paper demonstrates the cortical areas activated during imagined BCI-type tasks in a participant with Multiple Sclerosis (MS), and is a proof of concept for translating BCI research to potential users with MS.
This concise paper explores how Design-Based Research (DBR) can practically guide pedagogical innovation through collaborative curriculum design. We illustrate this with four short case studies (vignettes) of DBR implemented in different discipline contexts in higher education. An examination of the common characteristics of these four project designs show how DBR can be practically implemented as a transferable educational design framework. Future work includes deeper analysis and reporting on the longitudinal impact on student learning of these projects in a subsequent full journal paper.
Low decoding accuracy makes brain-computer interface (BCI) control of a robotic arm difficult. Shared control (SC) can overcome limitations of a BCI by leveraging external sensor data and generating commands to assist the user. Our study explored whether reaching targets with a robot end-effector was easier using SC rather than direct control (DC). We simulated a motor imagery BCI using a joystick with noise introduced to explicitly control interface accuracy to be 65% or 79%. Compared to DC, our prediction-based implementation of SC led to a significant reduction in the trajectory length of successful reaches for 4 (3) out of 5 targets using the 65% (79%) accurate interface, with failure rates being equivalent to DC for 2 (1) out of 5 targets. Therefore, this implementation of SC is likely to improve reaching efficiency but at the cost of more failures. Additionally, the NASA Task Load Index results suggest SC reduced user workload.Clinical relevance—Shared control can minimise the impact of BCI decoder errors on robot motion, making robotic arm control using noninvasive BCIs more viable