ABSTRACT In this study, we report the isomerization of an aspartic acid residue in the complementarity-determining region (CDR) of crizanlizumab as a major degradation pathway. The succinimide intermediate and iso-aspartic acid degradation products were successfully isolated by ion exchange chromatography for characterization. The isomerization site was identified at a DG motif in the CDR by peptide mapping. The biological characterization of the isolated variants showed that the succinimide variant exhibited a loss in target binding and biological activity compared to the aspartic acid and iso-aspartic acid variants of the molecule. The influence of pH on this isomerization reaction was investigated using capillary zone electrophoresis. Below pH 6.3, the succinimide formation was predominant, whereas at pH values above 6.3, iso-aspartic acid was formed and the initial amounts of succinimide dropped to levels even lower than those observed in the starting material. Importantly, while the succinimide accumulated at long-term storage conditions of 2 to 8°C at pH values below 6.3, a complete hydrolysis of succinimide was observed at physiological conditions (pH 7.4, 37°C), resulting in full recovery of the biological activity. In this study, we demonstrate that the critical quality attribute succinimide with reduced potency has little or no impact on the efficacy of crizanlizumab due to the full recovery of the biological activity within a few hours under physiological conditions.
In the present study, the application of a liquid chromatography high-resolution mass spectrometry (LC-HRMS) analytical assay for the quantitative analysis of a recombinant human immunoglobulin G1 (hIgG1) in rat serum is reported using three generic peptides GPSVFPLAPSSK (GPS), TTPPVLDSDGSFFLYSK (TTP), and VVSVLTVLHQDWLNGK (VVS). Moreover, the deamidation site of a fourth peptide FNWYVDGVEVHNAK (FNW) was identified and further excluded from the assay evaluation due to the inaccuracy of the quantitative results. The rat serum samples were spiked with a fully labeled hIgG1 as internal standard (ISTD). The digestion with trypsin was performed onto the pellet prior to peptide analysis by LC-HRMS using a quadrupole time of flight (QTOF) mass analyzer operating in selected reaction monitoring (SRM) mode with enhanced duty cycles (EDC). The assay linearity for the three investigated peptides was established for a hIgG1 (hIgG1A) from 1.00 to 1000 μg mL−1 with a mean coefficient of determination (R 2) higher than 0.9868. The inter-day accuracy and precision obtained in rat serum over 3 days were ≤11.4 and ≤10.5 %, respectively. Short-term stability on the auto-sampler at 6 °C for 30 h, at RT for 48 h, and a 100-fold dilution factor were demonstrated. In addition, QC samples prepared in cynomolgus monkey serum and measured with the present method met the acceptance criteria of ±20.0 and ≤20.0 % for all three peptides regarding accuracy and precision, respectively. The LC-HRMS method was applied to the analysis of samples from five individual cynomolgus monkeys dosed with a second hIgG1 (hIgG1B) and consistent data were obtained compared to the LC-MS/MS method (conventional triple quadrupole (QqQ) mass analyzer operating in SRM). The present data demonstrate that LC-HRMS can be used for the quantitative analysis of hIgG1 in both species and that quantification is not only limited to classical QqQ instruments.
An increasing demand of new analytical methods is associated with the growing number of biotherapeutic programs being prosecuted in the pharmaceutical industry. Whilst immunoassay has been the standard method for decades, a great interest in assays based on liquid chromatography tandem mass spectrometry (LC-MS/MS) is evolving. In this present work, the development of a generic method for the quantitative analysis of therapeutic proteins based on human immunoglobulin G (hIgG) in rat serum is reported. The method is based on four generic peptides GPSVFPLAPSSK (GPS), TTPPVLDSDGSFFLYSK (TTP), VVSVLTVLHQDWLNGK (VVS) and FNWYVDGVEVHNAK (FNW) originating from different parts of the fraction crystallizable (Fc) region of a reference hIgG1 (hIgG1A). A trsrptic pellet digestion of rat serum spiked with hIgG1A and a stable isotope labeled protein (hIgG1B) used as internal standard (ISTD) was applied prior LC-MS/MS analysis. The upper limit of quantification was at 1000 mu g/mL The lower limit of quantitation was for GPS, TTP and VVS at 1.00 mu g/ml. whereas for FNW at 5.00 mu g/mL. Accuracy and precision data met acceptance over three days. The presented method was further successfully applied to the quantitative analysis of other hlgGls (hIgG1C and hIgG1D) and hIgG4-based therapeutic proteins on spiked quality control (QC) samples in monkey and rat serum using calibration standards (Cs) prepared with hIgG1A in rat serum. In order to extend the applicability of our generic approach, a bispecific-bivalent hlgG1 (bb-hIgG1) and two lysine conjugated antibody-drug conjugates (ADC1 and ADC2) were incorporated as well. The observed values on spiked QC samples in monkey serum were satisfactory with GPS for the determination of bb-hIgG1 whereas the FNW and UP peptides were suitable for the ADCs. Moreover, comparable mean concentration-time profiles were obtained from monkeys previously dosed intravenously with ADC2 measured against Cs samples prepared either with hIgG1A in rat serum (presented approach) or with the actual ADC2 in monkey serum (conventional approach). The results of this study highlight the great flexibility of our newly developed generic approach and that the choice of the surrogate peptide still remains critical when dealing with different matrix types or modalities. (C) 2016 Elsevier B.V. All rights reserved.
A sensitive and specific method was developed and validated for the quantitation of maytansinoid (DM1) in human serum using on-line solid phase extraction (SPE)-liquid chromatography-tandem mass spectrometry (LC-MS/MS). Because DM1 contains a free thiol moiety, likely to readily dimerize or react with other thiol-containing molecules in serum, samples were pre-treated with a reducing agent [tris (2-carboxyethyl) phosphine] (TCEP) and further blocked with N-ethylmaleimide (NEM). The resulting samples were diluted with acetonitrile prior to the on-line solid phase extraction (SPE) on a C-18 cartridge. A C-18 (150 x 4.6 mm ID 3 mu m particle size) column was used for chromatographic separation with a 10.0 min HPLC gradient and DM1-NEM was detected in the selected reaction monitoring mode of a triple quadrupole mass spectrometer. DM1 concentrations were back-calculated from DM1-NEM amount found in the human serum samples. The quantitation range of the method was 0.200-200 ng/mL when using 0.25 mL serum. Within-run day precisions (n = 6) were 0.9-4.4% and between-run day (3 days runs; n = 18) precisions 2.5-5.6%. Method biases were between 3.5-14.5% across the whole calibration range. DM1-NEM exhibited sufficiently stability under all relevant analytical conditions and no DM1 losses from the ADC were observed. Finally, the assay was used for DM1 determination in human serum concentration after the intravenous administration of an investigational antibody drug conjugate (ADC) containing DM1 as payload. (C) 2015 Elsevier B.V. All rights reserved.
A series of new deoxyamodiaquine-based compounds was synthesized via the modified TMSN3-Ugi multi-component reaction and evaluated in vitro for antiplasmodial activity. The most potent compounds, 6b, 6c and 6j, showed IC50 values in the range of 6–77 nM against chloroquine-resistant K1- and W2-strains of Plasmodium falciparum. In vitro ADME characterization of frontrunner compounds 6b and 6c indicates that these two compounds are rapidly metabolized and have a high clearance rate in human and rat liver microsomes. This result correlated well with an in vivo pharmacokinetics study, which showed low bioavailability of 6c in rats. Tentative metabolite identification was determined by LC–MS and suggested metabolic lability of groups attached to the tertiary nitrogen. Preliminary studies on 6b and 6c suggested strong inhibitory activity against the major CYP450 enzymes. In silico docking studies were used to rationalize strong inhibition of CYP3A4 by 6c. Full characterization and biological evaluation of the metabolites is currently underway in our laboratories.
A new class of 4-aminoquinolines was synthesized and evaluated in vitro for antiplasmodial activity against both the chloroquine-sensitive (3D7) and -resistant (K1 and W2) strains. The most active compounds 3c-3e had acceptable cytotoxicity but showed strong inhibition toward a panel of cytochrome P450 enzymes in vitro. Pharmacokinetic studies on 3d and 3e in mice showed that they had moderate half-life (4-6 h) and low oral bioavailability. The front runner compound 3d exhibited moderate inhibition of the malaria parasite on P. berghei infected mice following oral administration (5 mg/kg), achieving reduction of parasitemia population by 47% on day 7.
An ultra-fast, reliable and sensitive analytical method enabling high-throughput quantitative analysis of pharmaceutical compounds in human plasma is described. The quantitative work was performed on one of our compound currently under clinical trial by employing a deuterated internal standard (IS). Plasma samples were treated on solid phase micro-extraction (SPME) plates prior their analysis by laser diode thermal desorption and atmospheric pressure chemical ionization coupled to tandem mass spectrometry (LDTD/APCI-MS/MS) in positive mode. The sample analysis run time was 10s as compared to the 7min obtained for the validated LC–MS/MS method. The limit of quantification (LOQ) of the method was estimated at 1ng/mL. The calibration graphs were linear with a regression coefficient R2>0.997. The data of the partial validation show that LDTD/APCI-MS/MS assay was highly reproducible and selective. In addition, the deviations for intra and inter assay accuracy and precision data were within 15% at all quality control levels. The LDTD/APCI-MS/MS method was successfully applied to the analysis of clinical samples and the data obtained were consistent with those found with a validated LC–MS/MS assay. This work demonstrates that LDTD/APCI-MS/MS could be used for the ultra-fast and reliable quantitative analysis of pharmaceutical compounds in human plasma without using the separation step commonly associated with the LC–MS/MS assay.
A LC–MS/MS method was developed and validated for determination of nucleoside analog (NA) in rat plasma. The method run time was 6min and the limit of quantification (LOQ) was estimated at 100pg/mL. The extraction procedure consisted on plasma samples protein precipitation with an acetonitrile solution which contained the stable isotope labeled internal standard (IS). Chromatography was performed on a newly developed C16 column (150mm×4.6mm, 5μm) in order to avoid the use ion pair salts. The samples were eluted at 0.8mL/min with a gradient of mobile phase made of water and acetonitrile both acidified with 0.5% acetic acid and 0.025% trifluoroacetic acid (TFA). A tandem mass spectrometer was used as a detector for quantitative analysis. Intra-run and inter-run precision and accuracy within ±15% were achieved during a 3-run validation for quality control samples at four concentration levels in rat plasma, over a concentration ranging between 0.1 and 1000ng/mL. The data indicate that our LC–MS/MS assay is an effective method for the pharmacokinetics study of NA in rat plasma.
Although LC-MS methods are increasingly used for the absolute quantification of proteins, the lack of appropriate internal standard (IS) hinders the development of rapid and standardized analytical methods for both in vitro and in vivo studies. Here, we have developed a novel method for the absolute quantification of a therapeutic protein, which is monoclonal antibody (mAb). The method combines liquid chromatography tandem mass spectrometry (LC-MS/MS) and protein cleavage isotope dilution mass spectrometry with the isotope-labeled mAb as IS. The latter was identical to the analyzed mAb with the exception that each threonine contains four (13)C atoms and one (15)N atom. Serum samples were spiked with IS prior to the overnight trypsin digestion and subsequent sample cleanup. Sample extracts were analyzed on a C18 ACE column (150 mm x 4.6 mm) using an LC gradient time of 11 min. Endogenous mAb concentrations were determined by calculating the peak height ratio of its signature peptide to the corresponding isotope-labeled peptide. The linear dynamic range was established between 5.00 and 1000 microg/mL mAb with accuracy and precision within +/-15% at all concentrations and below +/-20% at the LLOQ (lower limit of quantification). The overall method recovery in terms of mAb was 14%. The losses due to sample preparation (digestion and purification) were 72% from which about 32% was due to the first step of the method, the sample digestion. This huge loss during sample preparation strongly emphasizes the necessity to employ an IS right from the beginning. Our method was successfully applied to the mAb quantification in marmoset serum study samples, and the precision obtained on duplicate samples was, in most cases, below 20%. The comparison with enzyme-linked immunosorbent assay (ELISA) showed higher exposure in terms of AUC and Cmax with the LC-MS/MS method. Possible reasons for this discrepancy are discussed in this study. The results of this study indicate that our LC-MS/MS method is a simple, rapid, and precise approach for the therapeutic mAb quantification to support preclinical and clinical studies.
Analytical Chemistry is a peer-reviewed research journal that explores the latest concepts in analytical measurements and the best new ways to increase accuracy, selectivity, sensitivity, and reproducibility.