Background & objectives: India targets malaria elimination by 2030 in a phased manner, so malaria's assured diagnosis is crucial. Introduction of rapid diagnostic kits in India in 2010 has revolutionized malaria surveillance. The storage temperature of rapid diagnostic tests (RDTs), kit components and handling in transportations impact the results of RDTs. Therefore, quality assurance (QA) is required before it reaches end-users. The Indian Council of Medical Research-National Institute of Malaria Research (ICMR-NIMR) has a World Health Organization (WHO) recognized lot-testing laboratory facility to assure the quality of RDTs. Methods: The ICMR-NIMR receives RDTs from different manufacturing companies as well as various agencies such as National and State Programmes and Central Medical Services Society. The WHO standard protocol is followed to conduct all the tests, including long-term and post-dispatch testing. Results: A total of 323 lots tested during January 2014-March 2021 were received from different agencies. Amongst them, 299 lots passed the quality of test and 24 failed. In long-term testing, 179 lots were tested and only nine failed. A total of 7741 RDTs were received from end-users for post-dispatch testing of which 7540 qualified the QA test with a score of 97.4 per cent. Interpretation & conclusions: RDTs received for quality testing showed compliance with QA evaluation of malaria RDTs based on the protocol recommended by the WHO. However, continuous monitoring of the quality of RDTs is required under QA programme. Quality-assured RDTs have a major role, especially in areas where low parasitaemia of parasites persists.
Psyllaephagus malloticolae Rawat & Kumar sp. nov. a parasitoid of Trioza malloticola (Crawford) (Hemiptera, Psylloidea, Triozidae) causing galls on leaves of the Kamala tree, Mallotus philippensis Muell, 1865 is described from India. An updated key to all the known allied species of Psyllaephagus Ashmead from India is also provided. The new species comes close to P. garuga Sudhir & Singh, 2011 but differs from it in having Funicular V the longest segment, mid-tibial spur longer than basitarsus, and the exserted ovipositor sheath.
In the present work, coefficient of volume expansion is estimated using ultrasonic velocity and density of 8CB, 8CB + 0.5% ZnO, 8CB + 2.0% ZnO and 8CB + 5.0% ZnO mixtures in the temperature range of 283.15K-318.15K. The coefficient of volume expansion is used to evaluate numerous thermo-acoustic parameters viz; Moelwyn-Hughes parameter (C-1), Beyer's nonlinear parameter (B/A), reduced volume (V*), reduced bulk modulus (B*), isochoric acoustical parameter (Delta), fractional free volume (f), repulsive exponent (n), isobaric (Gamma), isochoric (Gamma ''), and isothermal (Gamma ') Gruneisen parameters, Anderson-Gruneisen parameter (delta) and Sharma's constant (S-0). Present study reveals that Sharma constant can be treated as molecular constant for 8CB and ZnO dispersed 8CB mixtures. A relationship between Delta approximately equal to B* +0.1 and C-1 approximately equal to delta +1 has been established for all the samples under investigation. The effect of increase of ZnO NPs concentration on the intermolecular interactions has been explained in terms of temperature variation of thermo-acoustical parameters.
Background: Recent studies have documented Pfhrp2/3 gene deletion globally as one of the biological threats in the fight against malaria. For malaria diagnosis, PfHRP2 based RDTs are most widely used in India, and performance of these RDTs are affected by deleted Pfhrp2/3 gene in Plasmodium falciparum. This study was planned to confirm Pfhrp2/3 gene deletion incidences and genetic variation in PfHRP2-based RDT positive with P.falciparum malaria cases from India.Methodology: Confirmed positive samples by PfHRP2-based RDTs as P. falciparum (n = 240) from six different endemic regions of India were validated by PCR to assure the actual infection. Two hundred forty samples qualified for DNA intactness by single-copy genes were subjected to amplification for the Pfhrp2/3 gene and its neighbouring gene (downstream and upstream) by PCR genotyping. Genetic variation in samples was analysed post-sequencing using Mega X software. Statistical analysis was performed to validate the genetic variation using Mann-Whitney Test.Results: RDT target region of Pfhrp2 gene (exon2) was found deleted in a single sample with presence of the Pfhrp3 exon2. Complete gene deletion of 4.2% was observed in the Pfhrp3 gene. Partial gene deletion was recorded for both pfhrp2 gene (exon2-0.4%, upstream 25.8% and downstream -9.1%) and Pfhrp3 gene (exon2-18.75%, upstream - 22.08% and downstream 13.3%). Eleven new unique types of amino acid repeat sequence and earlier reported amino acid repeat type was found in the Pfhrp2 gene, prompting high genetic variation.Conclusions: This study suggests that parasites lacking Pfhrp2/3 gene and its neighbouring gene (downstream and upstream) are present in malaria endemic areas of India, resulting in false positive results by RDT. Systematic countrywide monitoring for malaria control and elimination of malaria is warranted in this regard.
Dengue and chikungunya viruses are arthropod borne virus spread through common vector instigating infection in human. There has been an increased recognition that more attention needs to be paid to similar sympotoms caused by both of the virus as they spread in the same region at same time. It warrants need of cost effective, user friendly and rapid multiplex diagnostic technique which could simultaneously diagnose and identify between two virus diseases in resource poor setting. A magnetic multiplex loop mediated isothermal amplification (MM LAMP) technique was developed by coupling multiplex LAMP with magnetic particle-based naked eye visualization to overcome the shortcoming of simultaneous detection of both diseases. In recent years this technology has emerged as a particularly attractive candidate as amplification reaction process completes within 45 min. The first step involves multiplexing biotin and digoxigenin coated dengue and chikungunya primers respectively in LAMP reaction followed by precipitation of the amplified DNA with polyethylene glycol (PEG) buffer and finally clumping with streptavidin and anti-digoxigenin coated magnetic particle for virus discrimination and naked eye visualization. The DNA detection limit of MM LAMP visualization was 51.65 ng/mu l which is comparable to the electrophoresis base UV light visualization. The results showed potential superiority over standard methods polymerase chain reaction (PCR). This current advancement empowers multiplex LAMP utility in resource limited setting without using any of the florescent dyes, turbidimeter, or the sophisticated quantitative PCR machine etc which restrict multiplex LAMP technique to laboratorial use only. We have proposed a novel method without such limitations. This technique has potential as a point of care technique for simultaneous detection of two diseases.
Isothermal techniques with lateral flow detection have emerged as a point of care (POC) technique for malaria, a major parasitic disease in tropical countries such as India. Plasmodium falciparum and Plasmodium vivax are the two most prevalent malaria species found in the country. An advanced multiplex loop-mediated isothermal amplification (mLAMP) combined with a lateral flow dipstick (LFD) technique was developed for the swift and accurate detection of P. falciparum and P. vivax, overcoming the challenges of the existing RDTs (rapid diagnostic tests). A single set of LAMP primers with a biotinylated backward inner primer (BIP primer) was used for DNA amplification of both malaria species in a single tube. The amplified DNA was hybridized with fluorescein isothiocyanate (FITC) and digoxigenin-labelled DNA probes, having a complemented sequence for the P. falciparum and P. vivax genomes, respectively. A colour band appeared on two separate LFDs for P. falciparum and P. vivax upon running the hybridized solution over them. In total, 39 clinical samples were collected from ICMR-NIMR, New Delhi. Melting curve analysis, with cross primers for both species, was used to ascertain specificity, and the sensitivity was equated with a polymerase chain reaction (PCR). The results were visualized on the LFD for both species within 60 min. We found 100% sensitivity and specificity, when compared with a traditional PCR. Melting curve analysis of mLAMP revealed the lowest detection limit of 0.15 pg/μL from sample genomic DNA. The mLAMP-LFD assays could be a potential point of care (POC) tool for early diagnosis in non-laboratory conditions, with the convenience of a reduced assay time and the simple interpretation of results.
Dengue virus infects millions of the people globally each year and its diagnosis remains a challenge. Conventionally used diagnostic methods are complex and time consuming. LAMP technique is a potential alternative for diagnosis of dengue virus. The benefits of LAMP are its ease and ability, as it does not require an expensive equipment and results are effortlessly visualized by the naked eye. However, it does not aid as point of care technique owing to need of contamination free area, deep freezer for chemical storage and primer self amplification. Each small modification in LAMP method bring it towards an ideal point of care technique. An advanced lyophilized loop mediated isothermal amplification (L-LAMP) was developed in which the dye was dried on the cap and reaction reagents was lyophilized at the bottom of the tube to overcome the common hurdles of LAMP technique. The technique was able to diagnose disease within 35 min with 4U of Bst polymerase. The least concentration of dye required was 1000×. Result given by the seminested reverse transcriptase polymerase chain reaction (RT-PCR) and L-LAMP with enzyme linked immuno sorbent assay (ELISA) were compared using Chi square test. The L-LAMP showed 100 % specificity and 92 % sensitivity with respect ELISA and was found better than RT-PCR which showed 100 % specificity and 88 % sensitivity. There was no cross reactivity of primers with other disease like malaria caused by Plasmodium falciparum and P. vivax and with viral disease chikungunya. L-LAMP has dynamic potential as point of care technique.
BACKGROUND:Available DNA isolation methods for Plasmodium involve numerous processing steps, adding to the cost and conferring risk of contamination. Here we devise a simple and cost-effective method for direct extraction of Plasmodium DNA from dried filter paper spot (DBS), appropriate for resource-limited setups. METHODS:The protocol involves simple freezing and thawing of DBS, neither involves any purification step nor any chemical reagent. The method was assessed in terms of DNA quantity, PCR detection sensitivity, time requirement, cost effectiveness, labor intensiveness and degree of shearing. The reliability of this method was confirmed by comparing it with other in use methods for Plasmodium DNA isolation. RESULTS:Pure DNA was obtained with this method, as exemplified by the absorbance ratio (260nm /280nm) of 1.2. The protocol produced digestible, PCR-grade genomic DNA, also found to be suitable for sequencing. DNA isolated remained stable and retained its integrity after storage for one month at 4 °C. CONCLUSION:Our process substantiated as efficient, reproducible, simple, fast, and inexpensive. Development of this optimized freeze-thaw based DNA extraction method for malaria parasite may provide a valuable tool for molecular analysis in resource-limited setups. This is the first report of DNA extraction from DBS of Plasmodium utilizing freeze-thaw.
A Field study was conducted at Modipurma, Meerut (India) to determine the effectiveness of nine insecticides and biorational viz., thiamethoxam 25 WDG, imidacloprid 17.8 SL, dimetoate 30 EC, nuvaluron 10 EC, spinosad 45 SC, neemrin 1500 ppm, NSKE, Metarhizium anisopliae 2x109 CFU and Beauveria bassiana 2x109 CFU against mustard aphid, Lipaphis erysimi Kalt. The observations were recorded at 3, 7 and 10 days after spraying of insecticides. The results revealed that thiamethoxam 25 WDG was the most effective among the nine insecticides and biorational showing the minimum numbers of L. erysimi Kalt followed by imidacloprid 17.8 SL and Beauveria bassiana 2x109 CFU was recorded maximum population.