Two niobium elliptical 1.3 GHz superconducting radio frequency (SRF) electron photoinjector cavities were successfully recovered after mechanical inner surface damage. Both cavities had deep imprints in the critical high surface electric field area around the photoelectric cathode position. The lengthy repair procedure, which consists of surface inspection and defect characterization, mechanical polishing and light chemical etching is described in detail. In the process, a new high pressure rinsing (HPR) nozzle system optimized for the special photoinjector geometry was also developed. Subsequent cold RF tests demonstrate complete performance recovery. This is the first time that photoinjector cavities damaged in the high electric-field region could be recovered.
Helmholtz Zentrum Berlin is currently finalizing the construction of the demonstrator Energy Recovery Linac (ERL) bERLinPro [1]. The first part, which will be commissioned, will be the injector consisting of a superconducting RF (SRF) photo-injector (Gun) and a Booster module made up of three two cell SRF cavities. For the latter the 2.3 MeV beam from the gun needs to be accelerated to 6.5 MeV, whereas one Booster cavity will be operated in zero-crossing mode for bunch-shortening. Thus, for the final stage with a 100 mA beam, the twin power couplers of the Booster cavity need to deliver up to 120 kW in travelling continous wave (CW) mode at 1.3 GHz each. To achieve that, a dedicated coupler conditioning setup was installed and commissioned. Here, we will present the first conditioning results with the bERLinPro Booster fundamental power couplers in pulsed and CW regime
Helmholtz-Zentrum Berlin (HZB) is currently constructing a high average current superconducting (SC) ERL as a prototype to demonstrate low normalized beam emittance of 1 mm·mrad at 100 mA and short pulses of about 2 ps. To attain the required beam properties, an SRF based photoinjector system was developed and during the past year underwent RF commissioning and was setup within a dedicated diagnostics beamline called Gunlab to analyze beam dynamics of both, a Copper cathode and a CsK2Sb cathode as well as their quantum efficiency at UV and green light respectively. The medium power prototype a first stage towards the final high power 100 mA design presented here features a 1.4×λ/2 cell SRF cavity with a normal-conducting, high quantum efficiency Cs2KSb cathode, implementing a modified HZDR-style cathode insert. This injector potentially allows for 6 mA beam current and up to 3.5 MeV kinetic energy, limited by the modified twin TTF-III fundamental power couplers. In this contribution, the first RF commissioning results of the photo-injector module will be presented including dark current analysis as well as measured beam properties with an initially installed Copper cathode.
For CW applications of superconducting cavities, obtaining a high quality factor is an important issue: Since the required cryogenic power drops inversely proportional to 0, a higher quality factor of the cavities implies lower investment- and operational costs of the cryo-plant. 0 is limited by BCS-losses and residual losses from impurities, grain boundaries and trapped magnetic flux. In TESLA 9cell cavities typical values of 2⋅10 10 are being achieved at 1.8 K with sufficient magnetic shielding. We have observed a significant increase in the 0 value of up to 50% when subjecting the cavity to an additional cryogenic cooling cycle to intermediate temperatures above T . In a second set of experiment, the flux trapping was monitored by cooling the cavity down to 1.8 K at different ambient magnetic fields and results were compared with theoretical values.
In preparation for the construction of the BESSY-FEL User Facility, BESSY recently completed the installation of the HoBiCaT cryogenic test facility for superconducting RF (SRF) TESLA cavity units (1), including all ancillary devices (helium tank, input coupler, tuner, magnetic shield- ing). It is designed to house two such units in a configura- tion similar to that envisaged for the superconducting CW linac of the BESSY FEL. Commissioning of the facility is now complete and the first TTF-III RF coupler and cavity unit has been tested. In particular, the complete production, cleaning and assembly of the cavity unit was carried out by industry. These tests thus serve as a first step at qualifying industrial partners for series production of such systems, which will be essential for the future construction of SRF based light sources.
In the superconducting driver linac for the BESSY FEL, piezo actuators will be utilized to rapidly counteract the detuning of the cavity resonance caused by nm mechanical oscillations (microphonics). This is of importance to guarantee field stability and lower the power consumption of the RF system for the superconducting cavities. To design a suitablecompensator,mechanicaland electro-mechanical transfer functions, as well as the tuning range of the system under operating conditions have been measured.
In preparation for the construction of the BESSY-FEL User Facility, BESSY recently completed the installation of the HoBiCaT cryogenic test facility for superconducting RF (SRF) TESLA cavity units [1], including all ancillary devices (helium tank, input coupler, tuner, magnetic shielding). It is designed to house two such units in a configuration similar to that envisaged for the superconducting CW linac of the BESSY FEL. Commissioning of the facility is now complete and the first TTF-III RF coupler and cavity unit has been tested. In particular, the complete production, cleaning and assembly of the cavity unit was carried out by industry. These tests thus serve as a first step at qualifying industrial partners for series production of such systems, which will be essential for the future construction of SRF based light sources.