Background Increased arterial tortuosity has been associated with various cardiovascular complications. However, the extent and role of arterial tortuosity in non-atherosclerotic vascular diseases remain to be fully elucidated. This study aimed to assess arterial tortuosity index (ATI) in patients with non-atherosclerotic vascular diseases and the associated factors. Methods This is a retrospective analysis of patients with non-atherosclerotic vascular diseases referred to the Malformation and Rare Vascular Disease Center at the University Hospital in Lausanne (Switzerland). Computed tomography angiography (CTA) images performed between October 2010 and April 2022 were retrieved and the aortic tortuosity index (ATI) was calculated. Patients were classified based on diagnosis into the following groups: arterial dissection & aneurysm, arteritis & autoimmune disease, hereditary connective tissue diseases, and fibromuscular dysplasia (FMD). Univariate and multivariate logistic regression analysis was used to determine potentially relevant predictors of aortic tortuosity. Results The mean age upon computed tomography angiography (CTA) was 46.8 (standard deviation [SD] 14.6) years and 59.1% of the patients were female. Mean ATI was higher in patients over 60 years old (1.27), in those with arterial aneurysms (mean: 1.11), and in those diagnosed with hypertension (mean: 1.13). When only patients over 60 years old were considered, those diagnosed with connective tissue diseases had the highest ATI. At multivariate regression analysis, increasing age (p < 0.05), presence of arterial aneurysms (p < 0.05), and hypertension (p < 0.05) were independently associated with ATI. Conclusions The ATI may be a promising tool in diagnostic evaluation, cardiovascular risk stratification, medical or surgical management, and prognostic assessment in several non-atherosclerotic vascular conditions. Further studies with longitudinal design and larger cohorts are needed to validate the role of ATI in the full spectrum of vascular diseases.
Erectile dysfunction (ED) is a worldwide health concern and clinical condition for men, leading to high medical costs and imposing significant emotional and psychological burdens on sufferers annually. ED is associated with multiple causes, including psychological factors and organic issues such as arterial insufficiency and venous leakage. Endovascular treatments have emerged as promising options for managing ED, offering minimally invasive procedures that can improve blood flow to the penis and restore erectile function. Different endovascular interventional approaches have been implemented with varying success rates and therapeutic impacts, and efforts continue to optimize these methods (both arterial and venous) for maximum effectiveness and minimal invasiveness. This narrative review aims to provide an overview of endovascular treatments for arterial and venous types of ED, discussing their mechanisms of action, efficacy, safety, and future directions.
(1) Background: The peripherally inserted central catheter (PICC) is commonly used in medicine. The tip position was shown to be a major determinant in PICC function and related complications. Recent advances in ECG guidance might facilitate daily practice. This study aimed to compare two ECG techniques, in terms of their tip-position accuracy, puncture site layout, and signal quality; (2) Methods: This randomized open study (1:1) included 320 participants. One PICC guidance technique used ECG signal transmission with saline (ST); the other technique used a guidewire (WT). Techniques were compared by the distance between the catheter tip and the cavoatrial junction (DCAJ) on chest X-rays, insertion-point hemostasis time, and the extracorporeal catheter length between the hub and the insertion point; (3) Results: The mean DCAJs were significantly different between ST (1.36 cm, 95% CI: 1.22–1.37) and WT (1.12 cm, 95% CI: 0.98–1.25; p = 0.013) groups. When DCAJs were classified as optimal, suboptimal, or inadequate, the difference between techniques had limited clinical impact (p = 0.085). However, the hemostasis time at the puncture site was significantly better with WT (no delay in 82% of patients) compared to ST (no delay in 50% of patients; p < 0.001). Conversely, ST achieved optimal and suboptimal extracorporeal lengths significantly more frequently than WT (100% vs. 66%; p < 0.001); (4) Conclusions: ECG guidance technologies achieved significantly different tip placements, but the difference had minimal clinical impact. Nevertheless, each technique displayed an important drawback at the PICC insertion point: the extracorporeal catheter was significantly longer with WT and the hemostasis delay was significantly longer with ST.
ObjectivesThe percentage of shunt fraction significantly impacts the management of patients with congenital shunts, influencing strategic choices such as surgical or interventional procedures. This study compared the estimated shunt fraction (the ratio of pulmonary-to-systemic flow, Qp/Qs) for quantifying the left-to-right shunt in children with ventricular septal defect (VSD) using heart catheterization, four-dimensional (4D) flow, and two-dimensional (2D) flow magnetic resonance imaging (MRI). The goal was to establish a non-invasive and reliable measurement ratio between pulmonary and systemic blood flow in these patients.MethodsBetween July 2022 and June 2023, patients scheduled to undergo invasive right heart catheterization were included in this study. MRI was performed one hour before the catheterization procedure. The correlation of shunt fraction was assessed between all methods after calculating the Qp/Qs ratio from 2D and 4D flow MRI and catheterization.ResultsA total of 24 patients (aged 3–15 years, eight females) were ultimately included in the study. The Qp/Qs ratios obtained from 4D flow had a robust correlation (correlation coefficient r = 0.962) compared to those obtained during catheterization. Cardiac catheterization recorded the mean shunt fraction at 1.499 ± 0.396, while 4D flow measured it at 1.403 ± 0.344, with no significant difference between the two techniques. Moreover, there was a reasonable correlation (r = 0.894) between 2D flow measurements of Qp/Qs and the results obtained from catheterization, with a mean shunt fraction of 1.326 ± 0.283.Conclusion4D flow MRI has the potential to be a non-invasive method for accurately measuring the left-to-right shunt in children with VSD.
BACKGROUND:Complex coronary artery abnormalities (CAA) are rare findings with no established guideline for their management in asymptomatic patients. CASE SUMMARY:We report the case of a 49-year-old male patient, with no medical history, who was incidentally diagnosed for two congenital complex CAA during for the management of an acute coronary syndrome without ST elevation. The coronary angiogram showed an acute atheromatous occlusion of the right coronary artery (RCA) that was treated by a drug-eluting stent. Transcatheter angiograms as well as the coronary computed tomography (CT) also revealed an ectopic RCA arising from the left cuspid with an inter-arterial course, and a second left anterior descending artery emerging from the RCA with a retro-pulmonary course. The present acute coronary syndrome was not in relation to his congenital disease but with an atheromatous disease. On 48 months of follow-up, the transthoracic echocardiography is normal and the patient remains asymptomatic despite the risk of sudden cardiac death and myocardial infarction. DISCUSSION:This case shows that CAA can be clinically silent for a long period of time without any correction. It highlights that ischemia in patients with CAA is not always due to the congenital disease. As patients seemed to remain at SCD risk despite surgical correction, not correcting the CAA might remain an alternative in asymptomatic adult patients.
This study aimed to evaluate the efficacy of the Chat Generative Pre-trained Transformer (ChatGPT) in guiding the need for invasive coronary angiography (ICA) in high-risk non-ST-elevation (NSTE) acute coronary syndrome (ACS) patients based on both standard clinical data and coronary computed tomography angiography (CCTA) findings. This investigation is a sub-study of a larger prospective multicentric double blinded project where high-risk NSTE-ACS patients underwent CCTA prior to ICA to compare coronary lesion by both modalities. ChatGPT analyzed clinical vignettes containing patient data, electrocardiograms, troponin levels, and CCTA results to determine the necessity of ICA. The AI’s recommendations were then compared to actual ICA findings to assess its decision-making accuracy. In total, 86 patients (age: 62 ± 13 years old, female 27 CCTA : coronary computed tomography angiography; ECG : electrocardiogram; ICA : invasive coronary angiogram; NSTE-ACS : non-ST-elevation acute coronary syndrome.
Objectives: The cavo-atrial junction (CAJ) is the most appropriate central venous catheters CVC tip location to reduce complications. Among chest X-ray (CXR) landmarks for tips assessment, only the pericardial reflection lies in the same plane as the vascular structures. We aimed to evaluate the observer variability to determine tip positioning on CXR, using CT as a gold standard. Methods: We retrospectively analyzed 107 CT scans of patients with port catheters (January-December 2021). The tip to CAJ distance (DCAJ) was measured on both projectional (PJ) and cross-sectional (CS) CT images by 2x 2 observers (within and between evaluations). Observational statistics included paired t-tests, repeatability coefficients (RC), and intraclass correlation coefficients (ICC), with data visualized using Bland-Altman plots. Results: All ICC were >0.9, indicating excellent reliability. The mean difference between observers comparing CS and PJ was 0.13 +/- 0.80 cm (P 1 / 4 .10) with outer 95% confidence limits of 1.92 cm and -2.17 cm and an RC of 1.79 cm. Conclusion: CXR provides a reliable method for CVC tip localization, though assessment variability is +/- 2 cm. Advances in knowledge: CXR assessment of CVC tips shows both intra- and inter-individual variability, due to challenges in identifying the CAJ and catheter tip . While considering the 3 cm anatomical zone around the CAJ acceptable, operators should be aware of the 2 cm variability resulting from CXR assessment. To account for this variability and avoid the risk of positioning the tip beyond 3 cm from the CAJ, operators should reduce the CXR-based acceptable zone to 1 cm around the CAJ, impacting approximately 30% of procedures.
High-risk coronary plaques (HRP) are characterized in clinical radiological imaging by the presence of low plaque attenuation, a napkin-ring sign (NRS), spotty calcifications (SC) and a positive remodeling index (RI). To evaluate if these signs are detectable in postmortem imaging by a multi-phase postmortem CT angiography (MPMCTA), a retrospective study of a series of autopsy well-documented coronary plaques related to sudden cardiac death (SCD) was performed. Then correlations between histological and radiological findings were described. Fourty SCD cases due to acute coronary syndrome based on clinical history and confirmed at autopsy were selected (28 men and 12 women, age 53.3 ± 10.9). The culprit lesion was mainly situated in the proximal segments of coronary arteries, in the right coronary artery in 23 cases (57.5
We read with great interest the review by Wang et al. entitled “Identification Markers of Carotid Vulnerable Plaques: An Update”, recently published in Biomolecules [...]
Hypnosis is useful for diminishing distress during medical procedures. This study investigated the efficacy of virtually augmented self-hypnosis as an adjunctive non-pharmacological method for procedural pain and anxiety relief during endovascular interventions (EVI). We compared an immersive distraction experience (clinicaltrials.gov identifier NCT04561596) featuring virtual reality (VR) using a head-mounted display versus treatment as usual (TAU). Patients followed the “Aqua” module (Oncomfort™) consisting of a scuba dive and breathing exercises. They experienced a self-induced dissociative state similar to clinical hypnosis without direct intervention of a professional. Enrollment followed a 1:1 randomized open study (VR or TAU). Patients’ feelings were evaluated just before and after the procedure, and 3 months following intervention. Anxiety was evaluated using the State Trait Anxiety Inventory (STAI) and pain (sensory, emotional, and memory) with a visual analogue scale (VAS). This study included 100 patients. Mean anxiety (pre-post) was significantly reduced within groups and between groups (difference of 4.2 points, p = 0.016). The percentage of responders to anxiety lowering were 76 and 46
A 64-year-old woman who underwent deceased donor kidney transplantation 15 months earlier was admitted for an increase in serum creatinine. A right flank bruit was noted with otherwise normal whole body examination. Blood tests displayed an acute increase of serum creatinine (204 μmol/l from baseline of 130 μmol/l) in the absence of donor-specific anti–human leukocyte antigen antibodies or significant BK viremia. Urine cultures were negative. An ultrasound reported normal size kidney allograft without hydronephrosis or perirenal collection. Doppler ultrasound revealed a large hilar arteriovenous fistula (AVF) and renal vein stenosis, confirmed by arteriography (Figure 1; Supplementary Figures S1 and S2).
In this paper, a wideband antenna is proposed for ultra-wideband microwave imaging applications. The antenna is comprised of a tapered slot ground, a rectangular slotted patch and four star-shaped parasitic components. The added slotted patch is shown to be effective in improving the bandwidth and gain. The proposed antenna system provides a realized gain of 6 dBi, an efficiency of around 80% on the radiation bandwidth, and a wide impedance bandwidth (S11 < −10 dB) of 6.3 GHz (from 3.8 to 10.1 GHz). This supports a true wideband operation. Furthermore, the fidelity factor for face-to-face (FtF) direction is 91.6%, and for side by side (SbS) is 91.2%. This proves the excellent directionality and less signal distortion of the designed antenna. These high figures establish the potential use of the proposed antenna for imaging. A heterogeneous breast phantom with dielectric characteristics identical to actual breast tissue with the presence of tumors was constructed for experimental validation. An antenna array of the proposed antenna element was situated over an artificial breast to collect reflected and transmitted waves for tumor characterization. Finally, an imaging algorithm was used to process the retrieved data to recreate the image in order to detect the undesirable tumor object inside the breast phantom.
Objectives To evaluate the diagnostic utility of multiphase postmortem CT angiography (PMCTA) to detect plaque enhancement as a surrogate marker of inflammation, using fatal coronary plaques obtained from autopsies following sudden cardiac death. Methods In this retrospective study, we included 35 cases (12 women, 34%; median [IQR] age, 52 [11] years), with autopsy-proven coronary thrombosis, histological examination, and multiphase PMCTA. Two radiologists blinded towards histological findings assessed PMCTA for plaque enhancement of the culprit lesion in consensus. Two forensic pathologists determined the culprit lesion and assessed histological samples in consensus. Cases with concomitant vasa vasorum density increase and intraplaque and periadventital inflammation were considered positive for plaque inflammation. Finally, we correlated radiology and pathology findings. Results All 35 cases had histological evidence of atherosclerotic plaque disruption and thrombosis; 30 (85.7%) had plaque inflammation. Plaque enhancement at multiphase PMCTA was reported in 21 (60%) and resulted in a PPV of 95.2% (77.3–99.2%) and an NPV of 28.6% (17–43.9%). Median histological ratings indicated higher intraplaque inflammation ( p = .024) and vasa vasorum density ( p = .032) in plaques with enhancement. We found no evidence of a difference in adventitial inflammation between CT-negative and CT-positive plaques ( p = .211). Conclusions Plaque enhancement was found in 2/3 of fatal atherothrombotic occlusions at coronary postmortem CT angiography. Furthermore, plaque enhancement correlated with histopathological plaque inflammation and increased vasa vasorum density. Plaque enhancement on multiphase CT angiography could potentially serve as a noninvasive marker of inflammation in high-risk populations. Clinical relevance statement Phenotyping coronary plaque more comprehensively is one of the principal challenges cardiac imaging is facing. Translating our ex vivo findings of CT-based plaque inflammation assessment into clinical studies might help pave the way in defining high-risk plaque better. Key Points • Most thrombosed coronary plaques leading to fatality in our series had histological signs of inflammation. • Multiphase postmortem CT angiography can provide a noninvasive interrogation of plaque inflammation through contrast enhancement. • Atherosclerotic plaque enhancement at multiphase postmortem CT angiography correlated with histopathological signs of plaque inflammation and could potentially serve as an imaging biological marker of plaque vulnerability.
Pelvic venous disorders (PeVD), sometimes referred to as pelvic congestion syndrome (PCS), widely impact affected patients–mainly young women’s quality of life, causing puzzling, uncomfortable symptoms sometimes requiring months or years to get an explanation, while simply remaining undiagnosed in other cases. Because pelvic pain is a non-specific symptom, an appropriate diagnosis requires a careful patient workup, including a correlation between history and non-invasive imaging. Invasive imaging is frequently required to confirm the diagnosis and plan treatment. Current therapeutic approaches principally rely on minimally invasive techniques delivered through endovascular access. However, while comprehensive descriptive classifications such as the symptoms-varices-pathophysiology (SVP) classification exist, universally accepted guidelines regarding therapy to apply for each SVP category are still lacking. This review strongly focuses on PeVD imaging and discusses available therapeutic approaches with regard to pathophysiological mechanisms. It proposes a new classification scheme assisting clinical decision-making about endovascular management to help standardize the link between imaging findings and treatment.
Background: Coronary CT angiography (CCTA) is increasingly used as a non-invasive tool to assess coronary artery disease (CAD). However, CCTA is subject to motion artifacts, potentially limiting its clinical utility. Despite faster (0.35 and 0.28 s/rot) gantry rotation times, low (60–65 bpm) heartbeat is recommended, and the use of β-blockers is often needed. Technological advancements have resulted in the development of faster rotation speeds (0.23 s/rot). However, their added value in patients not premedicated with β-blockers remains unclear. This prospective single-center, two-arm, randomized, controlled trial aims to assess the influence of fast rotation on coronary motion artifacts, diagnostic accuracy of CCTA for CAD, and patient safety. Methods: We will randomize a total of 142 patients aged ≥ 50 scheduled for an aortic stenosis work-up to receive CCTA with either a fast (0.23) or standard (0.28 s/rot) gantry speed. Primary outcome: rate of CCTAs with coronary motion artifacts hindering interpretation. Secondary outcomes: assessable coronary segments rate, diagnostic accuracy against invasive coronary angiography (ICA), motion artifact magnitude per segment, contrast-to-noise ratio (CNR), and patient ionizing radiation dose. The local ethics committee has approved the protocol. Potential significance: FAST-CCT may improve motion artifact reduction and diagnosis quality, thus eliminating the need for rate control and β-blocker administration. Clinicaltrials.gov identifier: NCT05709652.
Coronary-pulmonary artery fistulas (CPAF) are congenital vascular anomalies detected incidentally in most cases. When a significant left-right shunt exists, surgical, or percutaneous treatment is indicated. We describe a challenging case of CPAF closure, by percutaneous approach, in a patient symptomatic for dyspnea and evidence of a significant left-right shunt. A first attempt to close the fistula was performed implanting a vascular plug but it quickly embolized. The plug was successfully retrieved. In a second attempt, we deployed several coils before implanting the vascular plug with total closure of the fistula. The combination of plugs and coils is associated with a higher success rate of closure.
Purpose To evaluate the correlation between whole lung enhancement (WLE) and pulmonary blood volume (PBV) obtained through dual energy computed tomography pulmonary angiography (DECTPA) and echocardiography-derived systolic pulmonary arterial pressure (SPAP). Methods Sixty-eight patients who underwent DECTPA were enrolled in the study after giving informed consent. A transthoracic echocardiography was performed for all the subjects within 48 h of their DECTPA study to measure SPAP. The correlation of the two DECTPA-derived parameters, WLE and PBV, with SPAP was assessed. In addition, the predictive strength of these parameters was compared with that of traditional computed tomography (CT) signs of pulmonary hypertension (PH). Results The SPAP value showed a moderate correlation with main pulmonary artery (MPA) diameter (r = 0.48, P < 0.001), while having a weak correlation with WLE (r = −0.33, P = 0.007), PBV (r = −0.31, P = 0.01) and MPA/ascending aorta (MPA/AA) ratio (r = 0.26, P = 0.03). On regression analysis, MPA diameter (B ± SE: 1.8 ± 0.6, P = 0.004) and WLE (B ± SE: −0.5 ± 0.3, P = 0.042) had significant association with SPAP. In addition, SPAP ≥30 mmHg was related to the right to left ventricular diameter (RV/LV) ratio [OR (CI 95%): 24.39 (1.3–573.2), P = 0.04] and reversely associated with PBV [OR (CI 95%): 0.96 (0.93–0.98), P = 0.005]. Acquired cutoff value of 83% for PBV showed sensitivity and specificity of 73% to identify SPAP ≥30 mmHg [AUC (CI 95%):0.727 (0.588–0.866), P = 0.008]. Conclusions Automated postprocessing calculation of iodine distribution analysis by DECTPA could be considered as an adjunctive tool to investigate for PH.
Noninvasive methods of estimating invasively measured fractional flow reserve (FFRinvasive) are actively being explored, aiming to avoid the use of an invasive pressure wire and the administration of hyperemia‐inducing drugs. Coronary angiography‐derived FFR (FFRangio) has already demonstrated its diagnostic performance in the context of stable coronary artery disease. However, its applicability in the context of non‐ST‐segment elevation myocardial infarction (NSTEMI) has yet to be established. We sought to determine the diagnostic performance of FFRangio exclusively in patients presenting with NSTEMI. We performed a prospective, single‐center, single‐arm, double‐blinded study comparing FFR calculated by FFRangio to FFRinvasive in NSTEMI patients. FFRinvasive was measured in all angiographically intermediate lesions (30%–70% stenosis) and was then compared to FFRangio which was calculated at the same position, by a blinded operator. The primary endpoints were the sensitivity and specificity of FFRangio for predicting FFRinvasive using a cut‐off value of ≤0.80. Among 100 NSTEMI patients who were screened, 46 patients with 60 vessels in total underwent FFRinvasive and were included in the study. The mean value of FFRinvasive was 0.83 ± 0.3 with 22 (36%) being ≤0.80 while the mean FFRangio was 0.82 ± 0.1 with 22 (36%) being ≤0.80. FFRangio exhibited a sensitivity of 95.5%, a specificity of 97.4%, and a diagnostic accuracy of 96.7%. FFRangio can precisely and noninvasively estimate FFRinvasive in acute coronary syndromes and may have a role in guiding treatment decisions related to angiographically intermediate coronary lesions in this context.
Intracavitary electrocardiography is an accurate guidance technique for peripherally inserted central catheters (PICC) tip location that is spreading widely among providers using non x-ray-based facilities. The principle behind this technology relies on the transmission of the electrocardiographic signal at the tip of the catheter and its use as an internal mobile electrode, allowing the system to identify the cavo-atrial junction (CAJ) through internal P-wave amplitude modulations. The gain in popularity of intracavitary electrography and its large diffusion have led manufacturers to offer various devices with heterogeneous properties, among which clinician who place PICCs have to choose. It is therefore important to understand differences between available techniques and devices. The potential impact might not only affect availability and costs but also the clinical impact through advantages and limitations regarding electric signal transmission PICC selection. Current perspectives on intracavitary electrocardiography will also be discussed, to give the reader a global view of the management of electrocardiographically guided PICCs, especially in an environment without x-ray support.