RATIONALE:High costs and student numbers can often hinder implementation of mass spectrometry (MS) in the undergraduate teaching laboratory, often with technicians running samples on students' behalf, and the implementation of MS only in discrete or isolated experiments. This study explores the use of atmospheric solids analysis probe MS (ASAP-MS) as a relatively low-cost, benchtop instrument, and its potential for application as a 'bolt-on' to existing undergraduate organic chemistry experiments. METHODS:Thirteen products synthesised in undergraduate laboratory experiments were analysed by ASAP-MS, along with their starting materials. Analysis was carried out with a Waters RADIAN ASAP mass spectrometer, at four different cone voltages simultaneously to provide fragmentation information. RESULTS:Out of the 13 undergraduate experiments, ASAP-MS was shown to be complementary in 11 of these, either through simple analysis of the precursor ion or by a more complex analysis of the fragments. CONCLUSIONS:ASAP-MS provided spectra that both complement and enhance intended learning outcomes in existing organic chemistry experiments, showing its versatility as a bolt-on technique. Moving forward, ASAP-MS will be integrated into the University of Surrey's undergraduate teaching laboratory.
The utilization of ambient ionization (AI) techniques for mass spectrometry (MS) has significantly grown due to their ability to facilitate rapid and direct sample analysis with minimal sample preparation. This study investigates the performance of various AI techniques, including atmospheric solids analysis probe (ASAP), thermal desorption corona discharge (TDCD), direct analysis in real time (DART), and paper spray coupled to a Waters QDa mass spectrometer. The focus is on evaluating the linearity, repeatability, and limit of detection (LOD) of these techniques across a range of analytes, including amino acids, drugs, and explosives. The results show that each AI technique exhibits distinct advantages and limitations. ASAP and DART cover high concentration ranges, which may make them suitable for semiquantitative analysis. TDCD demonstrates exceptional linearity and repeatability for most analytes, while paper spray offers surprising LODs despite its complex setup (between 80 and 400 pg for most analytes). The comparison with electrospray ionization (ESI) as a standard method shows that ambient ionization techniques can achieve competitive LODs for various compounds such as PETN (80 pg ESI vs 100 pg ASAP), TNT (9 pg ESI vs 4 pg ASAP), and RDX (4 pg ESI vs 10 pg ASAP). This study underscores the importance of selecting the appropriate ambient ionization technique based on the specific analytical requirements. This comprehensive evaluation contributes valuable insights into the selection and optimization of AI techniques for diverse analytical applications.
Ambient ionization (AI) is a rapidly growing field in mass spectrometry (MS). It allows for the direct analysis of samples without any sample preparation, making it a promising technique for the detection of explosives. Previous studies have shown that AI can be used to detect a variety of explosives, but the exact gas-phase reactions that occur during ionization are not fully understood. This is further complicated by differences in mass spectrometers and individual experimental set ups between researchers. This study investigated the gas-phase ion reactions of five different explosives using a variety of AI techniques coupled to a Waters QDa mass spectrometer to identify selective ions for explosive detection and identification based on the applied ambient ionization technique. The results showed that the choice of the ion source can have a significant impact on the number of ions observed. This can affect the sensitivity and selectivity of the data produced. The findings of this study provide new insights into the gas-phase ion reactions of explosives and could lead to the development of more sensitive and selective AI-based methods for their detection.
The ability to determine the purity (% controlled compound) of drug-of-abuse samples is necessary for public health and law enforcement. Here, we describe the assessment of atmospheric solids analysis probe (ASAP) for the rapid determination of drug purity for a set of formulated pharmaceuticals, chosen due to their availability, uncontrolled status and consistency. Paracetamol and loratadine were used as models of high and low purity compounds being ~90% and ~10% active ingredient, respectively. Individual tablets were ground up and diluted in an internal standard solution. The resulting samples were analysed by ASAP coupled to a Waters QDa mass spectrometer followed by confirmatory testing by liquid chromatography-tandem mass spectrometry (LC-MS/MS). The inclusion of a non-matched internal standard (quinine) improved linearity and repeatability of drug analysis by ASAP-MS. Levels of drug purity using formulated pharmaceutical tablets were found to be highly comparable with results produced by the 'gold standard' LC-MS/MS technique. Rapid determination of drug purity is therefore possible with ASAP-MS for highly concentrated samples with minimal sample preparation. It may be possible to use this deployable system to determine drug purity outside of a laboratory setting.
Rationale Direct analysis in real time is typically performed using helium as the ionisation gas for the detection of analytes by mass spectrometry (MS). Nitrogen and argon are found with abundance in the air and provide a cheaper and greener alternative to the use of helium as ionisation gas. This study explores the use of helium, nitrogen and argon as ionisation gas for the detection of organic compounds. Methods Four illicit drugs, two amino acids and five explosives were chosen as target analytes to understand selectivity, sensitivity and linearity when helium, nitrogen or argon was used as the ionisation gas with the direct analysis in real time (DART) source. Analysis was carried out on a Waters Acquity QDa single quadrupole mass spectrometer. Results Calibration curves over the range of 5–100 ng were produced for each analyte using the different ionisation gases to assess the instrument response. Nitrogen gave a higher response to concentration than helium or argon; however, the lowest limits of detection were observed when helium was used. Conclusions All the target analytes were detected using DART‐MS with helium, nitrogen or argon as the ionisation gas. Whereas helium provided the highest sensitivity, nitrogen produced reasonable limits of detection and had good linearity across the concentration range explored, suggesting it provides a greener and cheaper alternative to helium.
Five different classes of explosives were analysed by ambient ionisation mass spectrometry testing selectivity, sensitivity, and repeatability. We compare the effectiveness of two techniques (ASAP and SESI) for the trace detection of five explosives representative of the most common classes of high explosive: HMTD, RDX, PETN, Tetryl and TNT. Experiments also compared the effectiveness of sample loading via a glass fibre swab or glass rod. All analyses were carried out with a Waters Acquity QDa mass spectrometer, a small format mass spectrometer which can be operated in a transportable mode (using ambient air and a small diaphragm pump). Both ambient ionisation techniques, ASAP and SESI, successfully detected the five different explosives which could make them suitable for a screening method. By directly comparing a calibration range of 0.8 e10 ng on both swabs and rods for each explosive, it appears that SESI produces less variability per repeat, particularly at the higher end of the range when compared to ASAP which typically has a lower limit of detection and better linearity. (c) 2021 Published by Elsevier B.V.
Polypyrrole (PPy) fibre electrodes were studied to determine their ability to sense paracetamol (as a model drug) in the presence of the interferents dopamine and ascorbic acid. PPy was electropolymerised onto carbon fibres using cyclic voltammetry in the presence of two different counter anions: sodium dodecyl sulfate (SDS) and potassium nitrate (KNO3). The surface of the PPy.SDS and PPy.KNO3 fibre electrodes was characterised using Raman spectroscopy and scanning electron microscopy. The PPy.SDS-coated carbon fibre had a 14-fold larger electrochemical surface area compared to a bare carbon fibre (calculated using the Randles-Sevcik equation). The use of a large counter anion as dopant (dodecyl sulfate) produced fibres with a greater drug sensing response (cf. the use of smaller nitrate anion). The use of the PPy.SDS fibre electrode in differential pulse voltammetry (DPV) allowed sensing of paracetamol with a detection limit (3s S/N) of 34 mu M. For the anodic peak current (0.5 V vs. Ag/AgCl), a linear response range was observed for 50 -500 mu M. At a paracetamol concentration of 100 mu M, the DPV anodic peak current (at 0.5 V vs. Ag/AgCl) was unaffected by the addition of interferents: 100 mu M dopamine and 100 mu M ascorbic acid. A real-world application of drug sensing was trialled with the anti-psychotic medication clozapine; where the PPy.SDS carbon fibre could sense clozapine with a detection limit of (3s S/N) of 6 mu M and a sensitivity of 15 mu A cm(-2) mu mol(-1) L.