Background: To reduce the radiation exposure from chest computed tomography (CT), ultralow-dose CT (ULDCT) protocols performed at sub-millisievert levels were previously tested for the evaluation of pulmonary nodules (PNs). The purpose of our study was to investigate the effect of ULDCT and iterative image reconstruction on volumetric measurements of solid PNs. Methods: CT datasets of an anthropomorphic chest phantom containing solid microspheres were obtained with a third-generation dual-source CT at standard dose, 1/8th, 1/20th and 1/70th of standard dose [CT volume dose index (CTDIvol): 0.03-2.03 mGy]. Semi-automated volumetric measurements were performed on CT datasets reconstructed with filtered back projection (FBP) and advanced modelled iterative reconstruction (ADMIRE), at strength level 3 and 5. Absolute percentage error (APE) evaluated measurement accuracy related to the effective volume. Scan repetition differences were evaluated using Bland-Altman analysis. Two-way analysis of variance (AlOVA) assessed influence of different scan parameters on APE. Proportional differences (PDs) tested the effect of dose settings and reconstruction algorithms on volumetric measurements, as compared to the standard protocol (standard dose-FBP). Results: Bland-Altman analysis revealed small mean interscan differences of APE with narrow limits of agreement (-0.1%+/- 4.3% to -0.3%+/-.3.8%). Dose settings (P<0.001), reconstruction algorithms (P<0.001), nodule diameters (P<0.001) and nodule density (P=0.011) had statistically significant influence on APE. Post-hoc Bonferroni tests showed slightly higher APE when scanning with 1/70th of standard dose [mean difference: 3.4%, 95% confidence interval (CI): 2.5-4.3%; P<0.001], and for image reconstruction with ADMIRES (mean difference: 1.8%, 95% CI: 1.0-2.5%; P<0.001). No significant differences for scanning with 1/20th of standard dose (P=0.42), and image reconstruction with ADMIRE3 (P=0.19) were found. Scanning with 1/70th of standard dose and image reconstruction with FBP showed the widest range of PDs (-16.8% to 23.4%) compared to standard dose-FBP. Conclusions: Our phantom study showed no significant difference between nodule volume measurements on standard dose CT (CTDIvol: 2 mGy) and ULDCT with 1/20th of standard dose (CTDIvol: 0.10 mGy).
Rationale and Objectives: To evaluate the frequency and relevance of hypodense myocardium (HM) encountered in patients undergoing chest-pain CT in the emergency department (ED). Material and Methods: In this IRB-approved retrospective study, ECG-gated chest-pain CT examinations of 300 consecutive patients (mean age 60 +/- 17 years) presenting with acute chest-pain to our ED were evaluated. Once ST-segment elevation infarction was excluded, chest-pain CT including the coronary arteries (rule-out acute coronary syndrome (ACS), pulmonary embolism (PE) and acute aortic syndrome (AAS): chest-pain CTcoronary, n = 121) or not including the coronary arteries was performed (rule-out PE and AAS: chest-pain CTw/o coronary, n = 179). Each myocardial segment was assessed for the presence of HM; attenuation was measured and compared to normal myocardium. Results: HM was identified in 27/300 patients (9%): 12/179 in chest-pain CTw/o coronary (7%) and 15/121 in chest-pain CTcoronary (12%). Mean attenuation of HM (40 +/- 17 HU) was significantly lower than that of healthy myocardium (103 +/- 18 HU, p < 0.001), with a mean difference of 61 +/- 19 HU. In 15/27 patients (55.6%) with HM, the final diagnosis was acute MI, and in the remaining 12/27 patients (44.4%) previous MI was found in the patients' history. Chest-pain CTw/o coronary identified HM in 10/15 patients (66.6%) with a final diagnosis of acute MI. Conclusion: HM indicating acute MI are often encountered in chest pain CT in the ED, also in chest-pain CTw/o (coronary) when MI is not suspected. This indicates that the myocardium should always be analyzed for hypodense regions even when MI not suspected.
PURPOSE:To retrospectively evaluate diagnostic performance of dual-energy subtraction radiography (DESR) for interpretation of chest radiographs compared to conventional radiography (CR) using computed tomography (CT) as standard of reference. MATERIAL AND METHODS:A total of 199 patients (75 female, median age 67) were included in this institutional review board (IRB)-approved clinical trial. All patients were scanned in posteroanterior and lateral direction with dual-shot DE-technique. Chest CT was performed within ±72 hours. The system provides three types of images: bone weighted-image, soft tissue weighted-image, herein termed as DESR-images, and a standard image, termed CR-image (marked as CR-image). Images were evaluated by two radiologists for presence of inserted life support lines, pneumothorax, pleural effusion, infectious consolidation, interstitial lung changes, tumor, skeletal alterations, soft tissue alterations, aortic or tracheal calcification and pleural thickening. Inter-observer agreement between readers and diagnostic performance were calculated. McNemar's test was used to test for significant differences. RESULTS:Mean inter-observer agreement throughout the investigated parameters was higher in DESR images compared to CR-images (kDESR = 0.935 vs. kCR = 0.858). DESR images provided significantly increased sensitivity compared to CR-images for the detection of infectious consolidations (42% vs. 62%), tumor (46% vs. 57%), interstitial lung changes (69% vs. 87%) and aortic or tracheal calcification (25 vs. 73%) (p<0.05). There were no significant differences in sensitivity for the detection of inserted life support lines, pneumothorax, pleural effusion, skeletal alterations, soft tissue alterations or pleural thickening (p>0.05). CONCLUSION:DESR increases significantly the sensibility without affecting the specificity evaluating chest radiographs, with emphasis on the detection of interstitial lung diseases.
Purpose: To investigate the capability of 3D-dynamic oxygen-enhanced MR (OE-MR) and Computed tomography (CT) in patients with Cystic Fibrosis (CF) and pulmonary function tests (PFT). Materials/Methods: 13 patients (median age: 28, female n=7) with a range of CF lung disease underwent OE-MR (1.5 T MR scanner). Coronal T1 parameter maps were obtained during free breathing. 3D coronal volumes of both lungs were acquired while patients alternately breathed room air and 100% oxygen. Images were fitted pixel by pixel. T1-parameter maps were generated and the following OE-MR parameters were measured: maximum O2-uptake(dPO2), wash-in and wash-out time. CT and PFT were available. Brody score was assessed by two radiologists. Total CT Brody score (CF-CT) was compared with PFT (%FEV1) and the OE-MR parameters using Pearson correlation. Results: Intraclass correlation for CF-CT(range:2-53,median 32) was high (0.86). dPO2, wash-in and wash-out time showed a significant correlation with CF-CT (dPo2:r=-0.691;p=0.009; wash-in/wash out:r=0.712;p=0.006). There was a significant correlation between dPO2, wash-in time and %FEV1 (O2-uptake: r=0.85;p<0.001; wash-in: r=-0.86;p<0.001). Conclusion: Functional lung imaging using OE-MR has the capability to assess the severity of CF lung disease showing a significant correlation with %FEV1 and CT Brody score. For long-term CF care, avoidance of cumulative radiation burden is desirable and feasible using OE-MR.
To determine the lowest CT radiation dose-level at maintained image-quality and high sensitivity for detection of pulmonary-nodules in obesity. Single-energy CT with tin-filtration was performed in a chest-phantom with solid pulmonary-nodules simulating over-weight and obesity. CTDIvol of the standard-protocol was 0.41 mGy, subsequent scans were obtained at 1/2 and 1/4 dose-levels. Images were reconstructed using FBP and advanced-modeled iterative reconstruction (ADMIRE). Noise, image-quality, and sensitivity for nodule-detection were assessed. Noise was significantly reduced with ADMIRE (standard-dose: 73%; 1/2 dose: 73%; 1/4 dose: 71.2%; p < 0.001) compared to FBP. Image-quality was diagnostic for all images reconstructed with ADMIRE5. Sensitivity for nodule-detection was 100% at 1/2 and 1/4 dose-level for the phantom simulating over-weight and 97.37% (1/2 dose-level) and 81.58% (1/4 dose-level) for the phantom simulating obesity using ADMIRE5. In conclusion, single-energy CT with tin-filtration and ADMIRE shows potential for dose reduction in a phantom experiment down to 0.1 mGy in over-weight and 0.21 mGy obese subjects, while image quality and sensitivity for detection of solid pulmonary nodules remains high.
Objective The purpose of this study was to evaluate the influence of sinogram-affirmed iterative reconstruction (SAFIRE) on quantification of lung volume and pulmonary emphysema in low-dose chest computed tomography compared with filtered back projection (FBP). Methods Enhanced or nonenhanced low-dose chest computed tomography was performed in 20 patients with chronic obstructive pulmonary disease (group A) and in 20 patients without lung disease (group B). Data sets were reconstructed with FBP and SAFIRE strength levels 3 to 5. Two readers semiautomatically evaluated lung volumes and automatically quantified pulmonary emphysema, and another assessed image quality. Radiation dose parameters were recorded. Results Lung volume between FBP and SAFIRE 3 to 5 was not significantly different among both groups (all P > 0.05). When compared with those of FBP, total emphysema volume was significantly lower among reconstructions with SAFIRE 4 and 5 (mean difference, 0.56 and 0.79 L; all P < 0.001). There was no nondiagnostic image quality. Conclusions Sinogram-affirmed iterative reconstruction does not alter lung volume measurements, although quantification of lung emphysema is affected at higher strength levels.
PURPOSE:To compare prospectively, in patients undergoing chest computed tomography (CT) for pulmonary-nodules or infection, image-quality and accuracy of standard dose (SD) and reduced dose (RD) CT with tin-filtration.MATERIAL AND METHODS:This IRB-approved study included 100 consecutive patients (36 female;median age 56 years) referred for follow-up of pulmonary-nodules (n=43) or suspicion of infection (n=57) undergoing single-energy CT with SD and RD using tin-filtration at 100 kVp (CTDIvol 2.47 mGy and 0.07 mGy, respectively). Images were reconstructed with advanced modeled iterative reconstruction (ADMIRE) at strength 3 and 5. Image-noise was measured. Two independent readers evaluated nodules and pulmonary-infection. SD CT served as reference standard.RESULTS:No significant difference was found in noise between RD with ADMIRE5 and SD with ADMIRE3 (118HU ± 14 vs. 120HU ± 17; p=0.08). Sensitivity for detection of atelectasis and interstitial lung changes was higher in images reconstructed with ADMIRE5 (93% and 88%; respectively) than in those reconstructed with ADIMRE3 (77% and 78%; respectively). Sensitivity for detection of consolidations was 90% for ADMIRE3 and 89% for ADMIRE5. Sensitivity for nodule detection was 71% for ADMIRE3 and 81% for ADMIRE5. Specificity for detection of atelectasis and interstitial lung changes was 99% and 96% with ADMIRE5 and 99% and 96% with ADMIRE3. Specificity for detection of consolidations was 99% for ADMIRE3 and 5. Specificity for detection of nodules was 87% for both ADMIRE3 and 5.CONCLUSION:Chest CT with a radiation dose equivalent to conventional radiography is feasible and allows for detection of pulmonary infection with high sensitivity, whereas the accuracy for detecting nodules is only moderate.
Because there is little evidence concerning the benefit of bronchoalveolar lavage (BAL) for diagnosis of peripheral lung cancer (PLC), we investigated 260 patients who had BAL among other bronchoscopic modalities for the diagnosis of a suspected PLC. Sensitivity of BAL was poor. Even the ability to diagnose pulmonary (co-) infection did not improve BAL's diagnostic value for either solid or ground-glass lesions.Background: There is a paucity of data concerning the benefit of bronchoalveolar lavage (BAL) for the diagnosis of suspected peripheral lung cancer (PLC). The aim of this study was to investigate the diagnostic value of BAL for the diagnosis of suspected PLC. Patients and Methods: All flexible bronchoscopies that included BAL among other modalities (brush, forceps, washing) for the diagnosis of a suspected PLC performed between 2009 and 2013 were analyzed in this retrospective study. Results: A total of 260 patients were included. Malignancy was present in 61%. BAL's sensitivity for the diagnosis of malignancy was 29%, and overall diagnostic yield of BAL was 46%. However, only 1% of cancer diagnoses would have been missed in the absence of BAL. In the multivariable analysis, the size of lesion (odds ratio [OR], 1.17; 95% confidence interval [CI], 1.02-1.33; P = .023), the presence of bronchus sign (OR, 4.73; 95% CI, 1.06-21.08; P = .042), and the presence of mediastinal/hilar lymphadenopathy (OR, 3.37; 95% CI, 1.53-7.41; P = .002) were associated with improved BAL true-positive ratio relating to diagnosis of malignancy. However, the effect of lesion size on sensitivity was small (area under the curve, 0.31; 95% CI, 0.23-0.40; P <.001). Ground-glass lesions were not associated with improved BAL diagnostic value. The number needed to test for BAL for the diagnosis of malignancy or pulmonary infection was 37. Conclusion: Conventional BAL has a low diagnostic value for the diagnosis of suspected PLC, and the low number needed to test does not qualify BAL as a recommended routine investigation for the diagnosis of suspected PLC for either solid or ground-glass lesions. (C) 2016 Elsevier Inc. All rights reserved.
OBJECTIVES To investigate the diagnostic performance of advanced modelled iterative reconstruction (ADMIRE) to filtered back projection (FBP) when using an ultralow-dose protocol for the detection of solid and subsolid pulmonary nodules. METHODS Single-energy CT was performed at 100 kVp with tin filtration in an anthropomorphic chest phantom with solid and subsolid pulmonary nodules (2-10 mm, attenuation, 20 to -800 HU at 120 kVp). The mean volume CT dose index (CTDIvol) of the standard chest protocol was 2.2 mGy. Subsequent scans were obtained at 1/8 (0.28 mGy), 1/20 (0.10 mGy) and 1/70 (0.03 mGy) dose levels by lowering tube voltage and tube current. Images were reconstructed with FBP and ADMIRE. One reader measured image noise; two readers determined image quality and assessed nodule localization. RESULTS Image noise was significantly reduced using ADMIRE compared with FBP (ADMIRE at a strength level of 5 : 70.4% for 1/20; 71.6% for 1/8; p < 0.001). Interobserver agreement for image quality was excellent (k = 0.88). Image quality was considered diagnostic for all images at 1/20 dose using ADMIRE. Sensitivity of nodule detection was 97.1% (100% for solid, 93.8% for subsolid nodules) at 1/20 dose and 100% for both nodule entities at 1/8 dose using ADMIRE 5. Images obtained with 1/70 dose had moderate sensitivity (overall 85.7%; solid 95%; subsolid 73.3%). CONCLUSION Our study suggests that with a combination of tin filtration and ADMIRE, the CTDIvol of chest CT can be lowered considerably, while sensitivity for nodule detection remains high. For solid nodules, CTDIvol was 0.10 mGy, while subsolid nodules required a slightly higher CTDIvol of 0.28 mGy. ADVANCES IN KNOWLEDGE Detection of subsolid nodules is feasible with ultralow-dose protocols.
Objectives: To assess the diagnostic accuracy of standard axial 64-slice chest CT compared to aortic valve image plane ECG-gated cardiac CT for bicuspid aortic valves.Materials and methods: The standard axial chest CT scans of 20 patients with known bicuspid aortic valves were blindly, randomly analyzed for (i) the appearance of the valve cusps, (ii) the largest aortic sinus area, (iii) the longest aortic cusp length, (iv) the thickest aortic valve cusp and (v) valve calcification. A second blinded reader independently analyzed the appearance of the valve cusps. Forty-two age- and sex-matched patients with known tricuspid aortic valves were used as controls. Retrospectively ECG-gated cardiac CT multiphase reconstructions of the aortic valve were used as the gold-standard.Results: Fourteen (21%) scans were scored as unevaluable (7 bicuspid, 7 tricuspid). Of the remainder, there were 13 evaluable bicuspid valves, ten of which showed an aortic valve line sign, while the remaining three showed a normal Mercedes-Benz appearance owing to fused valve cusps. The 35 evaluable tricuspid aortic valves all showed a normal Mercedes-Benz appearance (P = 0.001). Kappa analysis = 0.62 indicating good interobserver agreement for the aortic valve cusp appearance. Aortic sinus areas, aortic cusp lengths and aortic cusp thicknesses of >= 3.8 cm(2), 3.2 cm and 1.6 mm respectively on standard axial chest CT best distinguished bicuspid from tricuspid aortic valves (P < 0.0001 for all). Of evaluable scans, the sensitivity, specificity, positive and negative predictive values of standard axial chest CT in diagnosing bicuspid aortic valves was 77% (CI 0.54-1.0), 100%, 100% and 70% respectively.Conclusion: The aortic valve is evaluable in approximately 80% of standard chest 64-slice CT scans. Bicuspid aortic valves may be diagnosed on evaluable scans with good diagnostic accuracy. An aortic valve line sign, enlarged aortic sinuses and elongated, thickened valve cusps are specific CT features. (C) 2014 Elsevier Ireland Ltd. All rights reserved.
Purpose The purpose of this study was to evaluate the image quality and sensitivity of ultralow radiation dose single-energy computed tomography (CT) with tin filtration for spectral shaping and iterative reconstructions for the detection of pulmonary nodules in a phantom setting.Methods Single-energy CT was performed using third-generation dual-source CT (SOMATOM Force; 2 x 192 slices) at 70 kVp, 100 kVp with tin filtration (100Sn kVp), and 150Sn kV with tube current-time product adjustments resulting in standard dose (CT volume dose index, 3.1 mGy/effective dose, 1.3 mSv at a scan length of 30 cm), 1/10th dose level (0.3 mGy/0.13 mSv), and 1/20th dose level (0.15 mGy/0.06 mSv). An anthropomorphic chest phantom simulating an intermediate-sized adult with randomly distributed solid pulmonary nodules of various sizes (2-10 mm; attenuation, 75 HU at 120 kVp) was used. Images were reconstructed with advanced model-based iterative reconstruction (ADMIRE; strength levels 3 and 5) and were compared with those acquired with second-generation dual-source CT at 120 kVp (reconstructed with filtered back projection) and sinogram-affirmed iterative reconstruction (strength level 3) at the lowest possible dose at 120 kVp (CT volume dose index, 0.28 mGy). One blinded reader measured image noise, and 2 blinded, independent readers determined overall image quality on a 5-grade scale (1 = nondiagnostic to 5 = excellent) and marked nodule localization with confidence rates on a 5-grade scale (1 = unsure to 5 = high confidence). The constructional drawing of the phantom served as reference standard for calculation of sensitivity. Two patients were included, for proof of concept, who were scanned with the 100Sn kVp protocol at the 1/10th and 1/20th dose level.Results Image noise was highest in the images acquired with second-generation dual-source CT and reconstructed with filtered back projection. At both the 1/10th and 1/20th dose levels, image noise at a tube voltage of 100Sn kVp was significantly lower than in the 70 kVp and 150Sn kV data sets (ADMIRE 3, P < 0.01; ADMIRE 5, P < 0.05). Sensitivity of nodule detection was lowest in images acquired with second-generation dual-source CT at 120 kVp and the lowest possible dose. Protocols at 100Sn kVp and ADMIRE 5 showed highest sensitivity at the 1/10th and 1/20th dose levels. Highest numbers of false-positives occurred in second-generation dual-source CT images (range, 12-15), whereas lowest numbers occurred in the 1/10th and 1/20th dose data sets acquired with third-generation dual-source CT at 100Sn kVp and reconstructed with ADMIRE strength levels 3 and 5 (total of 1 and 0 false-positives, respectively). Diagnostic confidence at 100Sn kVp was significantly higher than at 70 kVp or 150Sn kV (ADMIRE 3, P < 0.05; ADMIRE 5, P < 0.01) at both the 1/10th and 1/20th dose levels. Images of the 2 patients scanned with 100Sn kVp at the 1/10th and 1/20th dose levels were of diagnostic quality.Conclusions Our study suggests that chest CT for the detection of pulmonary nodules can be performed with third-generation dual-source CT producing high image quality, sensitivity, and diagnostic confidence at a very low effective radiation dose of 0.06 mSv when using a single-energy protocol at 100 kVp with spectral shaping and when using advanced iterative reconstruction techniques.
OBJECTIVES:Early diagnosis of interstitial lung disease (ILD), currently the main cause of death in systemic sclerosis (SSc), is needed. The gold standard is high-resolution CT (HRCT) of the chest, but regular screening faces the risk of increased radiation exposure. We performed a prospective validation of a dedicated, 9-slice HRCT protocol with reduced radiation dose for the detection of ILD in patients with SSc. METHODS:We analysed 170/205 consecutive patients with SSc. Whole-chest HRCT, serving as standard of reference, and the reduced HRCT with nine slices allocated according to a basal-apical gradient were obtained. ILD presence, extent (> or <20%) and diagnostic confidence were assessed. The reduced HRCT was independently analysed by two blinded radiologists, who also evaluated image quality. Radiation dose parameters were calculated. RESULTS:Standard chest HRCT showed ILD in 77/170 patients. With the reduced HRCT, 68/77 cases with ILD were identified (sensitivity 88.3%, both readers). The accuracy (91.8%, reader 1; 94.7%, reader 2), diagnostic confidence (98.8%, reader 1; 95.3%, reader 2) and image quality rates were high. Minimal ILD was correctly quantified in 73.1% (reader 1)/71.2% (reader 2) and extensive ILD in 88% (reader 1)/100% (reader 2). Importantly, the reduced HRCT had a significantly lower radiation dose. The mean dose length product (effective dose) was only 5.66±4.46 mGycm (0.08±0.06 mSv) compared with the standard protocol dose of 149.00±95.90 mGycm (2.09±1.34 mSv). CONCLUSIONS:The above-described reduced chest HRCT protocol reliably detects even mild SSc-ILD in clinical practice, with the advantage of a much lower radiation dose compared with standard whole-chest HRCT.
OBJECTIVES:Atrial fibrillation (AF) is a significant risk factor for embolic stroke originating from the left atrial appendage (LAA). This is the first report of long-term safety and efficacy data on LAA closure using a novel epicardial LAA clip device in patients undergoing cardiac surgery.METHODS:Forty patients with AF were enrolled in this prospective 'first-in-man' trial. The inclusion criterion was elective cardiac surgery in adult patients with AF for which a concomitant ablation procedure was planned. Intraoperative transoesophageal echocardiography (TEE) was used to exclude LAA thrombus at baseline and evaluate LAA perfusion after the procedure, while computed tomography (CT) was used for serial imagery workup at baseline, 3-, 12-, 24- and 36-month follow-up.RESULTS:Early mortality was 10% due to non-device-related reasons, and thus 36 patients were included in the follow-up consisting of 1285 patient-days and mean duration of 3.5 ± 0.5 years. On CT, clips were found to be stable, showing no secondary dislocation 36 months after surgery. No intracardial thrombi were seen, none of the LAA was reperfused and in regard to LAA stump, none of the patients demonstrated a residual neck >1 cm. Apart from one unrelated transient ischaemic attack (TIA) that occurred 2 years after surgery in a patient with carotid plaque, no other strokes and/or neurological events demonstrated in any of the studied patients during follow-up.CONCLUSION:This is the first prospective trial in which concomitant epicardial LAA occlusion using this novel epicardial LAA clip device is 100% effective, safe and durable in the long term. Closure of the LAA by epicardial clipping is applicable to all-comers regardless of LAA morphology. Minimal access epicardial LAA clip closure may become an interesting therapeutic option for patients in AF who are not amenable to anticoagulation and/or catheter closure. Further data are necessary to establish LAA occlusion as a true and viable therapy for stroke prevention.CLINICAL TRIAL REGISTRATION:The trial is registered at www.ClinicalTrials.gov, reference: NCT00567515.
Rationale and Objectives: The objective of the study was to evaluate the performance of a non-contrast-enhanced magnetic resonance (MR) imaging protocol for preoperative screening of living related kidney donors.Materials and Methods: Forty consecutive subjects (mean age 52.2 +/- 11.3 years, range 29-73 years) underwent MR imaging with T2-weighted sequences (coronal and axial plane), with a non-contrast-enhanced respiratory-gated three-dimensional steady state free precession MR angiography (NCE-MRA) sequence and with contrast-enhanced magnetic resonance MR angiography (CE-MRA) sequences in the arterial and venous phases. Two blinded readers independently assessed arterial and venous anatomy and potential kidney lesions. Results of non-contrast-enhanced images were compared to CE-MRA and in a subgroup of 21 subjects to surgery as standard of reference.Results: Regarding arterial anatomy, NCE-MRA yielded sensitivity, specificity, and accuracy of 100%, 89%, and 91% compared to CE-MRA. Three kidneys were found to have more accessory renal arteries at NCE-MRA than at CE-MRA. In the subgroup of 21 subjects, 1 surgically proven accessory artery was depicted with NCE-MRA but not with CE-MRA. Accuracy of T2-weighted images regarding accessory veins or variant venous course was 99%, with one missed circumaortic vein on T2-weighted images. Two simple cysts were missed on T2-weighted and NCE-MRA but not on CE-MRA images.Conclusion: A non-contrast-enhanced MR imaging protocol including NCE-MRA and T2-weighted images allows for the accurate screening of living related kidney donors and may serve as an alternative to CE-MRA.
Objective: To experimentally evaluate three different contrast injection protocols at thoraco-abdominal high-pitch dual-source computed tomography angiography (CTA), with regard to level and homogeneity of vascular enhancement at different cardiac outputs.Materials and methods: A uniphasic, a biphasic as well as an individually tailored contrast protocol were tested using a human vascular phantom. Each protocol was scanned at 5 different cardiac outputs (3-5 L/min, steps of 0.5 L/min) using an extracorporeal cardiac pump. Vascular enhancement of the thoraco-abdominal aorta was measured every 5 cm. Overall mean enhancement of each protocol and mean enhancement for each cardiac output within each protocol were calculated. Enhancement homogeneity along the z-axis was evaluated for each cardiac output and protocol.Results: Overall mean enhancement was significantly higher in the uniphasic than in the other two protocols (all p < .05), whereas the difference between the biphasic and tailored protocol was not significant (p = .76). Mean enhancement among each of the 5 cardiac outputs within each protocol was significantly different (all p < .05). Only within the tailored protocol mean enhancement differed not significantly at cardiac outputs of 3.5 L/min vs. 5 L/min (484 +/- 25 HU vs. 476 +/- 19 HU, p = .14) and 4 vs. 5 L/min (443 +/- 49 HU vs. 476 +/- 19 HU, p = .05). Both, uniphasic and tailored protocol yielded homogenous enhancement at all cardiac outputs, whereas the biphasic protocol failed to achieve homogenous enhancement.Conclusion: This phantom study suggests that diagnostic and homogenous enhancement at thoraco-abdominal high-pitch dual-source CTA is feasible with either a uniphasic or an individually tailored contrast protocol. (C) 2011 Elsevier Ireland Ltd. All rights reserved.
A 77-year-old patient was referred for progressive fatigue and dyspnea on exertion. Preoperative imaging evaluations including transthoracic echocardiography and computed tomography were suggestive of a chronic ascending aortic dissection with an intramural hematoma. Intraoperatively, the intramural structure was identified as an abscess cavity.
Objectives: To prospectively evaluate the performance of unenhanced respiratory-gated magnetization-prepared 3D-SSFP inversion recovery MRA (unenhanced-MRA) to depict hepatic and visceral artery anatomy and variants in comparison to contrast-enhanced dynamic gradient-echo MRI (CE-MRI) and to digital subtraction angiography (DSA).Methods: Eighty-four patients (55.6 +/- 12.4 years) were imaged with CE-MRI (TR/TE 3.5/1.7 ms, TI 1.7 ms, flip-angle 15 degrees) and unenhanced-MRA (TR/TE 4.4/2.2 ms, TI 200 ms, flip-angle 90 degrees). Two independent readers assessed image quality of hepatic and visceral arteries on a 4-point-scale. Vessel contrast was measured by a third reader. In 28 patients arterial anatomy was compared to DSA.Results: Interobserver agreement regarding image quality was good for CE-MRI (kappa = 0.77) and excellent for unenhanced-MRA (kappa = 0.83). Unenhanced-MRA yielded diagnostic image quality in 71.6% of all vessels, whereas CE-MRI provided diagnostic image quality in 90.6% (p < 0.001). Vessel-based image quality was significantly superior for all vessels at CE-MRI compared to unenhanced-MRA (p < 0.01). Vessel contrast was similar among both sequences (p = 0.15). Compared to DSA, CE-MRI and unenhanced-MRA yielded equal accuracy of 92.9-96.4% for depiction of hepatic and visceral artery variants (p = 0.93).Conclusions: Unenhanced-MRA provides diagnostic image quality in 72% of hepatic and visceral arteries with no significant difference in vessel contrast and similar accuracy to CE-MRI for depiction of hepatic and visceral anatomy. (c) 2012 Elsevier Ireland Ltd. All rights reserved.
To prospectively assess the impact of sinogram-affirmed iterative reconstruction (SAFIRE) on image quality of nonenhanced low-dose lung CT as compared to filtered back projection (FBP).