BACKGROUND:In collaboration with the Office of Dietary Supplements at the National Institutes of Health, the National Institute of Standards and Technology issued a suite of botanical matrix reference materials (RMs) and Standard Reference Material® (SRM) for determination of isoflavones and toxic elements in kudzu dietary supplement ingredients. OBJECTIVE:RM 8650 Pueraria montana var. lobata (Kudzu) Rhizome, SRM 3268 Pueraria montana var. lobata (Kudzu) Extract, and RM 8652 Kudzu-Containing Solid Oral Dosage Form were issued with values assigned for isoflavones (puerarin, daidzin, and daidzein), toxic elements (arsenic, cadmium, and lead), and selenium. METHODS:Isoflavone values were assigned using liquid chromatography with UV absorbance or mass spectrometry detection. Element values were assigned using inductively coupled plasma mass spectrometry and results from an interlaboratory comparison exercise. RESULTS:Mass fractions for puerarin were 32.2 ± 3.2 mg/g, 128 ± 13 mg/g, and 68.2 ± 6.9 mg/g in RM 8650, SRM 3268, and RM 8652, respectively. Arsenic increases from 156 ± 14 ng/g to 849 ± 83 ng/g and cadmium decreases from 348 ± 14 ng/g to 82.1 ± 4.9 ng/g from rhizome to extract. CONCLUSION:The kudzu RM/SRM suite complements previously issued soy-related SRMs with values assigned for isoflavones, which have been studied for their potential health benefits, and expands the analytical resource by providing values for puerarin, an isoflavone not found in soy. HIGHLIGHTS:The three new kudzurmaterials are for use in the determination of isoflavones, toxic elements, and selenium. For the isoflavones, these new kudzu materials provide higher levels of daidzin and daidzein than existing soy-related SRMs, and they provide a value for an isoflavone not in existing SRMs (puerarin). Toxic elements in RM 8650 and SRM 3268 provide new botanical matrixes for use by dietary supplement manufacturers for the verification of the safety of their raw materials.
OBJECTIVES:Matrix differences among serum samples from non-pregnant and pregnant patients could bias measurements. Standard Reference Material 1949, Frozen Human Prenatal Serum, was developed to provide a quality assurance material for the measurement of hormones and nutritional elements throughout pregnancy. METHODS:Serum from non-pregnant women and women in each trimester were bottled into four levels based on pregnancy status and trimester. Liquid chromatography tandem mass spectrometry (LC-MS/MS) methods were developed and applied to the measurement of thyroid hormones, vitamin D metabolites, and vitamin D-binding protein (VDBP). Copper, selenium, and zinc measurements were conducted by inductively coupled plasma dynamic reaction cell MS. Thyroid stimulating hormone (TSH), thyroglobulin (Tg), and thyroglobulin antibody concentrations were analyzed using immunoassays and LC-MS/MS (Tg only). RESULTS:Certified values for thyroxine and triiodothyronine, reference values for vitamin D metabolites, VDBP, selenium, copper, and zinc, and information values for reverse triiodothyronine, TSH, Tg, and Tg antibodies were assigned. Significant differences in serum concentrations were evident for all analytes across the four levels (p≤0.003). TSH measurements were significantly different (p<0.0001) among research-only immunoassays. Tg concentrations were elevated in research-only immunoassays vs. Federal Drug Administration-approved automated immunoassay and LC-MS/MS. Presence of Tg antibodies increased differences between automated immunoassay and LC-MS/MS. CONCLUSIONS:The analyte concentrations' changes consistent with the literature and the demonstration of matrix interferences in immunoassay Tg measurements indicate the functionality of this material by providing a relevant matrix-matched reference material for the different stages of pregnancy.
Vitamin D plays a vital role in successful pregnancy outcomes for both the mother and fetus. Vitamin D is bound to vitamin D binding protein (VDBP) in blood and is carried to the liver, kidneys and other target tissues. Accurate measurements of the clinically measured metabolite of vitamin D, 25-hydroxyvitamin D [25(OH)D], depend on complete removal from the binding protein. It has been found that VDBP concentrations increase in maternal serum during pregnancy, obfuscating the accuracy of 25(OH)D concentration measurements in pregnant women. Additionally, measurements of VDBP concentrations during pregnancy have been performed using immunoassays, which suffer from variations due to differences in antibody epitopes, making clinical comparisons difficult. Quantification of VDBP is also of interest because changes in VDBP expression levels may indicate negative outcomes during pregnancy, such as preterm delivery and restricted fetal growth. To address the need for accurate measurement of VDBP during pregnancy, a method using liquid chromatography-isotope dilution mass spectrometry (LC-IDMS) was developed to quantify VDBP using isotopically labeled peptides as internal standards. This method was used to quantify VDBP in Standard Reference Material® (SRM) 1949 Frozen Human Prenatal Serum, which was prepared from separate serum pools of women who were not pregnant and women during each trimester of pregnancy. VDBP concentrations were found to be lowest in the serum pool from non-pregnant women and increased in each trimester. These data had good repeatability and were found to be suitable for reference value assignment of VDBP in SRM 1949.
Primary mercury gas standards, traceable to the SI, have been developed which can be used to underpin a NIST traceability framework for the calibration of vapor phase continuous emission monitoring systems (CEMS). A gas standard, which is based on a commercial gas generator, has been certified for gaseous elemental mercury output at specified generator output set points. The standard, termed the NIST Prime (NP) was certified at selected set points in the range 0.25 mu g/m(3) to 38 mu g/m(3) by isotope dilution inductively coupled plasma - mass spectrometry (ID-ICP-MS) using two alternative approaches, based on directly coupled gas sampling, and activated carbon sorbent trapping. Both approaches have been used to provide NIST traceability for electric utility mercury CEMS. The directly coupled method yielded expanded measurement uncertainties ranging from approximately 5.5% relative at 0.5 mu g/m(3), to approximately 1% relative at 38 mu g/m(3), and an estimated limit of quantization (LOQ) of 0.06 mu g/m(3). The sorbent trapping method in contrast, yielded expanded uncertainties of approximately 1% relative at all sampling points, with an LOQ of 0.001 mu g/m(3).
We present a direct comparison between two independent methods for the measurement of gaseous elemental mercury (GEM) mass concentration: isotope dilution cold-vapor inductively coupled plasma mass spectrometry (ID-CV-ICP-MS) and laser absorption spectroscopy (LAS). The former technique combined with passive sorbent tube sampling is currently the primary method at NIST for mercury gas standards traceability to the International System of Units (SI). This traceability is achieved via measurements on a mercury-containing reference material. The latter technique has been recently developed at NIST and involves real-time measurements of light attenuation caused by GEM, with SI traceability based in part on the known spontaneous emission lifetime of the probed 6 1S0-6 3P1 intercombination transition of elemental mercury (Hg0). Using a steady-flow Hg0-in-air generator to produce samples measured by both methods, we use LAS to measure the sample gas and in parallel we collect the Hg0 on sorbent tubes to be subsequently analyzed using ID-CV-ICP-MS. Over the examined mass concentration range (41 μg/m3 to 287 μg/m3 Hg0 in air), the relative disagreement between the two approaches ranged from (1.0 to 1.8)%. The relative combined standard uncertainty on average is 0.4% and 0.9%, for the LAS and MS methods, respectively. Our comparison studies help validate the accuracy of the ID-CV-ICP-MS primary method as well as establish the LAS technique as an attractive alternative primary method for SI-traceable measurements of GEM.
American alligators are exposed to mercury (Hg) throughout their natural range and may maternally transfer Hg into their eggs. Wildlife species are highly sensitive to Hg toxicity during embryonic development and neonatal life, and information on Hg transfer into eggs is critical when attempting to understand the effects of Hg exposure on developing oviparous organisms. To examine Hg transfer in alligators, the objectives of the present study were to 1) determine Hg concentrations in yolk (embryonic and neonatal food source) from wild alligator eggs collected from three locations - Yawkey Wildlife Center SC (YWC), Lake Apopka FL (LA), and Lake Woodruff FL (LW); 2) examine the relationship between THg concentrations in wild alligator nest material and egg yolk at Merritt Island National Wildlife Refuge, FL; 3) examine the Hg concentrations in wild maternal female alligators (blood) and the THg in corresponding egg yolks and embryos across three nesting seasons at a single location (YWC), and evaluate the relationship between nesting female THg concentrations (blood) and their estimated age and number of nesting years (YWC); and 4) assess the transfer of biologically-relevant Hg concentrations (based on Hg measured in maternal female blood) into embryos using an egg-dosing experiment. Mean total Hg (THg) concentrations observed at each site were 26.3 ng/g ± 11.0 ng/g (YWC), 8.8 ng/g ± 5.1 ng/g (LA), and 22.6 ng/g ± 6.3 ng/g (LW). No relationship was observed between THg in alligator nest material and corresponding yolk samples, nor between THg in maternal alligator blood and estimated age and number of nesting years of these animals. However, significant positive relationships were observed between THg in blood of nesting female alligators and THg in their corresponding egg yolk. We observed that 12.8% of the maternal blood THg is found in the corresponding egg yolk, and a highly significant correlation was observed between the two sample types (r = 0.66; p < 0.0001). The egg dosing experiment revealed that Hg did not transfer through the eggshell at developmental stage 19. Overall, this study provides new information regarding Hg transfer in American alligators which can improve biomonitoring efforts and may inform ecotoxicological investigations and population management programs in areas of high Hg contamination.
Toxic trace element exposure occurs through release of the ubiquitous and naturally occurring elements arsenic (As), cadmium (Cd), lead (Pb), and mercury (Hg). The unique environmental conditions of the wetland ecosystems along the southeastern Atlantic coast of the United States lead to the accumulation of Hg which is greater than in most other ecosystems in the country. There are also point sources of As, Cd, and Pb in this region. To effectively monitor trace element concentrations, and consequently the potential human exposure, accessible local sentinel species are needed. In this study, concentrations of As, Cd, Pb, Hg and six other trace elements (Al, Ni, Cu, Zn, Se, Mo) were examined in American alligators (Alligator mississippiensis) from seven wetland sites in South Carolina and Florida and assessed for their utility as a sentinel species for human trace element exposure. Alligators were chosen as a potential sentinel as they share a common exposure with the local human population through their aquatic diet, and they are directly consumed commercially and through recreation hunting in this region. Sex was significantly related to the concentration of Zn, Mo, and Al, but not As, Pb, Hg, Cd, Se, or Cu. Site specific differences in element concentrations were observed for As, Pb, Hg, Cd, Se, Zn, and Mo. Size/age was significantly related to the element Hg and Pb concentrations observed. The observed concentration ranges for the four toxic elements, As (6-156 ng/g), Cd (0.3-1.3 ng/g), Pb (3-4872 ng/g), and Hg (39-2765 ng/g), were comparable to those previously reported in diverse human populations. In this region alligators are hunted recreationally and consumed by the local community, making them a vehicle of direct human toxic element exposure. We propose that the similarity in As, Cd, Pb, and Hg concentrations between alligators observed in this study and humans underscores how alligators can serve as a useful sentinel species for toxic element exposure.
..................................................................................................................................
In response to the environmental impact of mercury and the neuro-toxic risk associated with trophic transfer of methyl mercury to humans, the reduction of mercury emissions from coal-fired electric utilities, a significant anthropogenic source, is now receiving global attention. To address impending regulations for mercury reduction, there is a need to establish a mercury emissions measurement framework, which has demonstrated accuracy and traceability to national and international standards. To support this effort, the National Institute of Standards and Technology (NIST) has been working jointly with the United States Environmental Protection Agency (EPA) to develop a traceability system which links the output of elemental mercury calibration instrumentation sited at the power utilities, to the SI (International System of Units). This system is based on a reference (NIST Prime) elemental mercury generator standard, which is used by NIST to certify elemental mercury generators from the instrument vendors. These in turn are used by the instrument vendors to provide NIST traceable calibration for the instrumentation supplied to each electric utility. The NIST Prime generator is certified using a primary analytical method for the determination of mercury using sorbent trap analysis with isotope dilution cold-vapor inductively coupled plasma mass spectrometry (ID-CV-ICP-MS).
A Standard Reference Material (SRM) of seaweed, SRM 3232 Kelp Powder (Thallus laminariae) has been developed to support food and dietary supplement measurements in compliance with the Food Safety Modernization Act (FSMA) and the Dietary Supplement Health and Education Act of 1994 (DSHEA). The material was characterized for nutritional minerals, arsenic species, isomers of vitamin K1, proximates, and toxic elements. Kelp is a rich source of vitamins and minerals, and it is an excellent source of dietary iodine. Kelp also contains a large amount of arsenic, which is toxic as inorganic species but much less so as organic species. To capture the dietary profile of kelp, certified values were issued for As, Ca, Cd, Cr, Cu, Fe, Hg, I, K, Mg, Mn, Mo, Na, Pb, and Zn. Reference values for proximates were assigned. For the first time, a certified value for iodine, reference values for isomers of vitamin K1, and reference values for arsenic species including arsenosugars were assigned in a seaweed. SRM 3232 fills a gap in Certified Reference Materials (CRMs) needed for quality assurance and method validation in the compositional measurements of kelp and similar seaweeds used as food and as dietary supplements.
Elements in human serum serve as important biomarkers and their levels reflect the well-being of an individual. Electrolytes such as sodium (Na) and chloride (Cl) are crucial in maintaining the normal distribution of water, osmotic pressure and electrical neutrality in the body. Trace element such as copper (Cu) plays a part in many oxidation-reduction reactions and metalloenzymes. The majority of selenium (Se) exists as selenoproteins which are cofactors in the glutathione peroxidase activity that protects the body against free radicals. Phosphorus (P) is required for strong bones and teeth. It is also indispensable for growth, maintenance and repair of tissues and cells. The key comparison CCQM-K139: elements in human serum was coordinated by the Health Sciences Authority, Singapore. This comparison aimed to enable participating National Metrology Institutes (NMIs) and Designated Institutes (DIs) to demonstrate their competence in the determination of elements (electrolytes and essential elements) in human serum. The five measurands (Na, Cl, Cu, Se and P) selected for this comparison were not covered in the last two comparisons in the clinical area (CCQM-K14 and CCQM-K107) and offered different analytical challenges. Their concentration levels were within the normal biological range. They were also within the range of existing calibration and measurement capability (CMC) claims in the International Bureau of Weights and Measures' Key Comparison Database (BIPM KCDB). Ten institutes participated in the comparison for Na, eight for Cl, eleven for Cu, six for Se and eight for P. For the analysis of Na, Cu, Se and P, most of the participating institutes employed microwave-assisted digestion and acid digestion (with or without heating) sample dissolution. For the analysis of Cl, in addition to the microwave-assisted digestion and acid digestion, a wider variety of techniques were employed. These included matrix separation, alkaline extraction and coulometric titration. Inductively coupled plasma mass spectrometry (ICP-MS) and inductively coupled plasma optical emission spectrometry (ICP-OES) were the two most commonly used instrumental techniques. Other techniques used included ion chromatography (IC), flame atomic absorption spectrometry (FAAS), titration and micro-coulometry. The medians were used as the estimators of Key Comparison Reference Values (KCRVs) for all measurands. The KCRVs (± standard uncertainty) for Na, Cl, Cu, Se and P (in mg/kg) were 3346 (± 14), 3871 (± 22), 1.151 (± 0.007), 0.1292 (± 0.0007) and 125.70 (± 0.35), respectively. The k-factor of 2 was used for the estimation of the expanded uncertainties of the KCRVs. The degree of equivalence and its associated uncertainty were calculated for each submitted result. For the five measurands, most participating institutes were able to demonstrate their capabilities in the determination of elements in human serum. CMC claims based on elements covered in this study may include other elements with similar core competencies, such as zinc (Zn), potassium (K), magnesium (Mg), calcium (Ca) and iron (Fe), in a wide range of biological materials. The measurands should be at similar concentration range and analysed using the same measurement technique(s) applied in this key comparison. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Concentrations of mercury (Hg) are not well studied in free-ranging wildlife. Atmospheric deposition patterns of Hg have been studied in detail and have been modeled for both global and specific locations and often correlate to environmental impact. However, monitoring the impact of Hg deposition in wildlife is complicated due to local environmental conditions that can affect the transformation of atmospheric Hg to the biologically available forms (e.g., rainfall, humidity, pH, the ability of the environment to methylate Hg), as well as affect the accessibility to organisms for sampling. In this study, Hg concentrations in blood samples from a population of American alligators (Alligator mississippiensis) at Merritt Island National Wildlife Refuge (MINWR), FL, USA, over a seven-year period (2007 to 2014; n=174 individuals) were examined to assess Hg variation in the population, as well as the difference in Hg concentration as a function of health status. While most of this population is healthy, 18 individuals with low body mass indices (BMI, defined in this study) were captured throughout the sampling period. These alligators exhibited significantly elevated Hg concentrations compared to their age/sex/season matched counterparts with normal BMI, suggesting that health status should be taken into account when examining Hg concentrations and effects. Alligator blood Hg concentrations were related to the interaction of age/size, sex, and season. This study illustrates the value of a routinely monitored population of large predators in a unique coastal wetland ecosystem, and illuminates the value of long-term environmental exposure assessment.
Routine monitoring of contaminant levels in wildlife is important for understanding chemical exposure and ultimately the link to ecosystem and human health. This is particularly important when the monitored species is recreationally hunted for human consumption. In the southeastern United States, recreational alligator harvesting takes place annually and in locations that are known to be contaminated with environmental pollutants. In this study, we investigated the biodistribution of trace elements in the American alligator (Alligator mississippiensis) from five sites in Florida, USA. These sites are locations where annual recreational alligator harvesting is permitted and two of the sites are identified as having high mercury contamination with human consumption advisories in effect. We utilized routinely collected monitoring samples (blood and scute), a commonly consumed tissue (muscle), and a classically analyzed tissue for environmental contaminants (liver) to demonstrate how the trace elements were distributed within the American alligator. We describe elemental tissue compartmentalization in an apex predator and investigate if noninvasive samples (blood and scute) can be used to estimate muscle tissue concentrations for a subset of elements measured. We found significant correlations for Hg, Rb, Se, Zn and Pb between noninvasive samples and consumed tissue and also found that Hg was the only trace metal of concern for this population of alligators. This study fills a gap in trace elemental analysis for reptilian apex predators in contaminated environments. Additionally, comprehensive elemental analysis of routinely collected samples can inform biomonitoring efforts and consumption advisories.
Seasonal variation of mercury (Hg) is not well studied in free-ranging wildlife. Atmospheric deposition patterns of Hg have been studied in detail and have been modeled for both global and specific locations with great accuracy and correlates to environment impact. However, monitoring these trends in wildlife is complicated due to local environmental parameters (e.g., rainfall, humidity, pH, bacterial composition) that can affect the transformation of atmospheric Hg to the biologically available forms. Here, we utilized an abundant and healthy population of American alligators (Alligator mississippiensis) at Merritt Island National Wildlife Refuge (MINWR), FL, and assessed Hg burden in whole blood samples over a span of 7 years (2007 2014; n 174) in an effort to assess seasonal variation of total [Hg]. While the majority of this population is assumed healthy, 18 individuals with low body mass indices (BMI, defined in this study) were captured throughout the 7 year sampling period. These individual alligators exhibited [Hg] that were not consistent with the observed overall seasonal [Hg] variation, and were statistically different from the healthy population of alligators. The alligators with low BMI had elevated concentrations of Hg compared to their age/sex/season matched counterparts with normal BMI. Statistically significant differences were found between the winter and spring seasons for animals with normal BMI. The data in this report supports the conclusion that organismal total [Hg] do fluctuate directly with seasonal deposition rates as well as other seasonal environmental parameters, such as average rainfall and prevailing wind direction. This study highlights the unique environment of MINWR to permit annual assessment of apex predators, such as the American alligator, to determine detailed environmental impact of contaminants of concern.
Two new Standard Reference Materials (SRMs), SRM 2786 Fine Particulate Matter (<4 μm) and SRM 2787 Fine Particulate Matter (<10 μm) have been developed in support of the US Environmental Protection Agency’s National Ambient Air Quality Standards for particulate matter (PM). These materials have been characterized for the mass fractions of selected polycyclic aromatic hydrocarbons (PAHs), nitrated PAHs, brominated diphenyl ether (BDE) congeners, hexabromocyclododecane (HBCD) isomers, sugars, polychlorinated dibenzo-p-dioxin (PCDD) and dibenzofuran (PCDF) congeners, and inorganic constituents, as well as particle-size characteristics. These materials are the first Certified Reference Materials available to support measurements of both organic and inorganic constituents in fine PM. In addition, values for PAHs are available for RM 8785 Air Particulate Matter on Filter Media. As such, these SRMs will be useful as quality control samples for ensuring compatibility of results among PM monitoring studies and will fill a void to assess the accuracy of analytical methods used in these studies.