We evaluated the analytical and workflow characteristics of the ARIES Clostridium difficile assay, a recently developed qPCR-based test for toxigenic C. difficile ARIES was compared to the illumigene C. difficile assay, a commonly employed, loop-mediated amplification technique with similar sample-to-result capabilities. Following illumigene analysis, 122 positive and 164 negative stool specimens were banked for subsequent ARIES testing. The analytical agreement between the platforms was high: 93.4% positive agreement (89.0-97.8%) and 97.5% negative agreement (95.2-99.9%). For discordant specimens, amplification/bidirectional sequencing of tcdA/tcdB demonstrated toxigenic C. difficile in 2/4 illumigene(-)ARIES(+) and 2/8 illumigene(+)ARIES(-) specimens. In a time-motion study, the ARIES assay required less hands-on time than illumigene, but with greater total testing time. Overall, these findings support the ARIES C. difficile Assay as a new option for laboratories in their diagnostic repertoire.
ABSTRACT As pulmonary fungal infections continue to increase due to an increasing number of immunocompromised patients, rapid detection and accurate identification of these fungal pathogens are critical. A broad fungal assay was developed by incorporating broad-range multilocus PCR amplification and electrospray ionization/mass spectrometry (PCR/ESI-MS) to detect and identify fungal organisms directly from clinical specimens. The aims of this study were to evaluate the performance of PCR/ESI-MS for detection, identification, and determination of the distribution of fungal organisms in bronchoalveolar lavage (BAL) fluid specimens. The BAL fluid specimens submitted for fungal culture at Vanderbilt University Medical Center between May 2005 and October 2011 were included. Cultures and identification were done using standard procedures. In addition, DNA was extracted from BAL fluid specimens, and fungal DNA amplification/identification were performed by PCR/ESI-MS. The results were compared with those of the standard cultures. A total of 691 nonduplicated BAL fluid specimens with sufficient leftover volume for molecular testing were evaluated using PCR/ESI-MS. Among them, 134 specimens (19.4%) were positive for fungi by both culture and PCR/ESI-MS testing. Of the dual-positive specimens, 125 (93.3%) were positive for Candida and Aspergillus species, with concordances between culture and PCR/ESI-MS results being 84 (67.2%) at the species level and 109 (87.2%) at the genus level. In addition, 243 (35.2%) and 30 (4.3%) specimens were positive only by PCR/ESI-MS or by culture, respectively (odds ratio [OR] = 11.95, 95% confidence interval [CI] = 7.90 to 18.17, P = 0.0000). Codetection of fungal organisms was noted in 23 (3.3%) specimens by PCR/ESI-MS, which was significantly higher than the 4 (0.6%) in which they were noted by culture (OR = 5.91, 95% CI = 1.93 to 20.27, P = 0.0002). Among 53 specimens in which cultures failed because of bacterial overgrowth, at least one fungus was identified in 26 specimens (47.3%) by PCR/ESI-MS. PCR/ESI-MS provides an advanced tool for rapid and sensitive detection, identification, and determination of the distribution of fungal organisms directly from BAL fluid specimens. Moreover, it detected fungal organisms in specimens in which cultures failed because of bacterial overgrowth. The clinical relevance of the significantly higher detection rate of fungal organisms by PCR/ESI-MS merits further investigation.
Numerous viral and bacterial pathogens have been reported causing acute respiratory tract infection (ARTI). Nasopharyngeal swab (NPS) specimens from 351 patients (278 children, 73 adults) with suspected upper and lower ARTI were submitted during the study period from Jan. 2005 to Dec. 2006. Organism-specific nucleic acids were detected using TemPlex technology (ResPlex I and II, Genaco Biomedical Products, Huntsville, AL). Amplified products were identified using a suspension array for multiplex detection performed on a Luminex 100 instrument (Luminex, Austin, TX). A total of 221 viral and bacterial respiratory agents were detected in 148 patients (135 [48.5%] of the 278 children and 13 [17.8%] of the 73 adults) with suspected ARTI. A single respiratory pathogen was detected in 89 patients [25.35%], whereas mixed infection with two or three pathogens was found in 59 [16.8%] of 351 suspected patients. S. pneumonia was the most frequently isolated strain (54 [15.3%] of 351 patients), followed by H. influenzae (37 [10.5%]), rhinoviruses (35 [9.9%]), influenza A virus (23 [6.5%]), enteroviruses (19 [5.4%]), hMPV (14 [3.9%]), PIV-1 (12 [3.4%]), PIV-3 (11 [3.1%]), RSV (10 [2.8%]), and influenza B virus (6 [1.7%]). Mixed infections were more frequent in children (56 [20.1%] of 278) than adult patients (3 [4.1%] of 73 patients). The detection rate of the bacteria peaked in the spring season (37 [40.6%] of 91 bacteria), followed by winter (24 infections), autumn (18 infections) and summer (12 infections). The prevalence of co-infection is ~40%, finding a much higher incidence of co-infection with more than one agent than that reported previously.
Rapid and accurate detection of respiratory syncytial virus (RSV) provides pathogen-specific diagnosis, allows implementation of appropriate infection control measures, and improves patient management. One diagnostic challenge is that respiratory infections, which can be caused by several viral pathogens including RSV, usually present with similar signs and symptoms that are nearly indistinguishable by clinical diagnosis. We have described in the chapter a rapid, high-throughput laboratory technique that can detect a panel of common viral pathogens in one single reaction. With the combination of target-enriched multiplexing PCR amplification and Luminex suspension array identification, 12 common respiratory viruses, including RSV A and B, influenza virus A and B, parainfluenza virus 1, 2, 3, and 4, human metapneumovirus, rhinoviruses, enteroviruses, and SARS coronavirus, are detected and differentiated simultaneously within five hours.
ABSTRACT Rapid detection and identification of Ehrlichia species improves clinical outcome for patients suspected of ehrlichiosis. We describe an assay that employs multilocus PCR and electrospray ionization mass spectrometry (PCR/ESI-MS) to detect and identify Ehrlichia species directly from blood specimens. The results were compared to those of a colorimetric microtiter PCR enzyme immunoassay (PCR-EIA) used as a diagnostic assay. Among 213 whole-blood samples collected from patients who were clinically suspected of ehrlichiosis from 1 May to 1 August 2008 at Vanderbilt University Hospital, 40 were positive for an Ehrlichia species by PCR/ESI-MS, giving a positive rate of 18.8%. In comparison to the PCR-EIA, PCR/ESI-MS possessed a sensitivity, a specificity, and positive and negative predictive values of 95.0%, 98.8%, 95.0%, and 98.8%, respectively. The 38 specimens that were positive for Ehrlichia by both PCR/ESI-MS and the PCR-EIA were further characterized to the species level, with 100% agreement between the two assays. In addition, Rickettsia rickettsii was detected by PCR/ESI-MS from four specimens that were confirmed retrospectively by serology and PCR-EIA. In three specimens, the PCR/ESI-MS assay identified Pseudomonas aeruginosa , Neisseria meningitidis , and Staphylococcus aureus ; these were confirmed by culture and/or clinical diagnosis as being clinically relevant. From specimen processing to result reporting, the PCR/ESI-MS assay can be completed within 6 h, providing another laboratory tool for the diagnosis of ehrlichiosis. Moreover, this system may provide rapid detection and identification of additional pathogens directly from blood specimens.
ABSTRACT We evaluated a single membrane device assay for simultaneously detecting both Clostridium difficile glutamate dehydrogenase (GDH) and toxin A/B antigens against a standard that combines two PCR assays and cytotoxigenic culture. Results showing dual GDH and toxin A/B antigen positives and negatives can be reported immediately as true positives and negatives, respectively. Specimens with discrepant results for GDH and toxins A/B, which comprised 13.2% of the specimens, need to be retested.
A total of 525 cerebrospinal fluid (CSF) samples submitted during the 2007 and 2008 enteroviral seasons were included in a study to determine the prevalence of and potential risk factors for invalid Cepheid GeneXpert enterovirus assay (GXEA) results, as well as possible solutions for the problem. The invalid GXEA results were reported for 43 (8.2%) specimens and correlated with increased visibility of red blood cells (P < 0.0001) but not with CSF xanthochromia and clotting. Invalid GXEA result rates were markedly diminished by 82.1% and 96.0% and test sensitivities were minimally decreased by 1.7% and 3.6% when these specimens were tested at a 1:5 dilution and after a freeze-thaw cycle, respectively.
ABSTRACT Clinical presentations for viral respiratory tract infections are often nonspecific, and a rapid, high-throughput laboratory technique that can detect a panel of common viral pathogens is clinically desirable. We evaluated two multiplex reverse transcription-PCR (RT-PCR) products coupled with microarray-based systems for simultaneous detection of common respiratory tract viral pathogens. The NGEN respiratory virus analyte-specific assay (Nanogen, San Diego, CA) detects influenza A virus (Flu-A) and Flu-B, parainfluenza virus 1 (PIV-1), PIV-2, and PIV-3, and respiratory syncytial virus (RSV), while the ResPlex II assay (Genaco Biomedical Products, Inc., Huntsville, AL) detects Flu-A, Flu-B, PIV-1, PIV-2, PIV-3, PIV-4, RSV, human metapneumovirus (hMPV), rhinoviruses (RhVs), enteroviruses (EnVs), and severe acute respiratory syndrome (SARS) coronavirus (CoV). A total of 360 frozen respiratory specimens collected for a full year were tested, and results were compared to those obtained with a combined reference standard of cell culture and monoplex real-time TaqMan RT-PCR assays. NGEN and ResPlex II gave comparable sensitivities for Flu-A (82.8 to 86.2%), Flu-B (90.0 to 100.0%), PIV-1 (87.5 to 93.8%), PIV-3 (66.7 to 72.2%), and RSV (63.3 to 73.3%); both assays achieved excellent specificities (99.1 to 100.0%) for these five common viruses. The ResPlex II assay detected hMPV in 13 (3.6%) specimens, with a sensitivity of 80.0% and specificity of 99.7%. The ResPlex II assay also differentiated RSV-A and RSV-B and gave positive results for RhV and EnV in 31 (8.6%) and 19 (5.3%) specimens, respectively. PIV-2, PIV-4, and SARS CoV were not detected in the specimens tested. The two systems can process 80 (NGEN) and 96 (ResPlex II) tests per run, with a hands-on time of approximately 60 min and test turnaround times of 6 h (ResPlex II) and 9 h (NGEN). Multiple-panel testing detected an additional unsuspected 9 (3.4%) PIV-1 and 10 (3.7%) PIV-3 infections. While test sensitivities for RSV and PIV-3 need improvement, both the NGEN and ResPlex II assays provide user-friendly and high-throughput tools for simultaneous detection and identification of a panel of common respiratory viral pathogens in a single test format. The multiplex approach enhances diagnosis through detection of respiratory viral etiologic agents in cases in which the presence of the agent was not suspected and a test was not ordered by the clinicians.
The majority of existing human papillomavirus (HPV) genotyping assays are based on multiplex PCR using consensus or degenerate primers. We developed a Templex HPV assay that simultaneously detects and identifies 25 common HPV genotypes in a single-tube reaction using type-specific primers for the HPV-specific E6 and E7 genes. The analytical sensitivities of the Templex assay for HPV type 16 (HPV-16), -18, and -56 were 20, 100, and 20 copies per reaction mixture, respectively. The Templex assay provides semiquantitative information on each type when multiple HPV types coexist in one reaction. We tested 109 clinical cervical specimens previously evaluated with the Digene HC2 high-risk HPV DNA test and found 95.4% concordance between the assay results. The Templex assay provided type-specific results and found multiple types in 29.2% (14 of 48) of high-risk HPV-positive samples. The entire Templex procedure, including DNA extraction, can be completed within 5 hours, providing a rapid and reliable diagnostic tool for HPV detection and typing that is amenable to automation.
We compared the performances of three hepatitis C virus genotyping methodologies supplied by Bayer, Abbott, and Third Wave Technologies. Genotypes were determined for 136 of 137 specimens by the Bayer method, 121 of 137 specimens by the Invader assay, and only 77 of 137 specimens by the Abbott assay. All reported genotypes were concordant by all three methods.
BACKGROUND: Several nucleic acid amplification (NAA)-based kits are commercially available for the detection of Chlamydia trachomatis (CT) and Neisseria gonorrhoeae (GC). A parallel evaluation of the BD ProbeTec ET and the Roche Cobas Amplicor was performed and compared in respect to validity, cost-per-test, hands-on time and turnaround time. METHODS: A total of 703 endocervical swabs were collected at Vanderbilt’s STD clinic. These samples were tested for both CT and GC using the BD Probetec ET, Roche Cobas Amplicor and the GenProbe Pace 2 system. RESULTS: The test results were compared in respect to performance, timeliness, and cost. The positivity rate of the ProbeTec, Cobas Amplicor and Pace 2 was 7.4%, 7.1 % and 5.1% for CT and 1.9%, 1.7% and 1.6% for GC. Using a repeatedly positive result from any three tests as an evaluation standard, the sensitivity of the ProbeTec, Cobas Amplicor and Pace 2 was 96.3%, 92.6% and 66.7% for CT and 100%, 92.3% and 84.6% for GC, respectively. Hands-on time for all three procedures were similar, yet a lower turnaround time (TAT) was noted for the ProbeTec and Pace 2 (4 hours) as compared to the Cobas Amplicor (almost 6 hours). The cost-per test was lower with Pace 2 than either of the amplified tests, Cobas Amplicor and ProbeTec.
Nucleic acid-based tests are rapidly expanding in the field of diagnostic microbiology, due to their unique high sensitivity and specificity as well as rapid assay turnaround time. However, the potential of false positives and false negatives can hinder the wide application of these novel techniques. This mini-review article summarizes common causes and potential solutions for false-positives and false-negatives encountered in the field of diagnostic molecular microbiology.