Periprosthetic joint infection (PJI) is characterized by biofilm infection, which is difficult to alleviate while preserving implant integrity. Furthermore, long-term antibiotic therapy may increase the prevalence of drug-resistant bacterial strains, necessitating a non-antibacterial approach. Adipose-derived stem cells (ADSCs) exert antibacterial effects; however, their efficacy in PJI remains unclear. This study investigates the efficacy of combined intravenous ADSCs and antibiotic therapy in comparison to antibiotic monotherapy in a methicillin-sensitive Staphylococcus aureus (MSSA)-infected PJI rat model. The rats were randomly assigned and equally divided into 3 groups: no-treatment group, antibiotic group, ADSCs with antibiotic group. The ADSCs with antibiotic group exhibited the fastest recovery from weight loss, with lower bacterial counts (p = 0.013 vs. no-treatment group; p = 0.024 vs. antibiotic group) and less bone density loss around the implants (p = 0.015 vs. no-treatment group; p = 0.025 vs. antibiotic group). The modified Rissing score was used to evaluate localized infection on postoperative day 14 and was the lowest in the ADSCs with antibiotic group; however, no significant difference was observed between the antibiotic group and ADSCs with antibiotic group (p < 0.001 vs. no-treatment group; p = 0.359 vs. antibiotic group). Histological analysis revealed a clear, thin, and continuous bony envelope, a homogeneous bone marrow, and a defined, normal interface in the ADSCs with antibiotic group. Moreover, the expression of cathelicidin expression was significantly higher (p = 0.002 vs. no-treatment group; p = 0.049 vs. antibiotic group), whereas that of tumor necrosis factor (TNF)-α and interleukin(IL)-6 was lower in the ADSCs with antibiotic group than in the no-treatment group (TNF-α, p = 0.010 vs. no-treatment group; IL-6, p = 0.010 vs. no-treatment group). Thus, the combined intravenous ADSCs and antibiotic therapy induced a stronger antibacterial effect than antibiotic monotherapy in a MSSA-infected PJI rat model. This strong antibacterial effect may be related to the increased cathelicidin expression and decreased inflammatory cytokine expression at the site of infection.
We aimed to assess the reliability and validity of OpenPose, a posture estimation algorithm, for measuring hip-knee-ankle (HKA) angle in patients with knee osteoarthritis, by comparing it with radiography. In this prospective study, we analysed 60 knees (30 patients) with knee osteoarthritis. We measured HKA angle using OpenPose and radiography before or after total knee arthroplasty and assessed the test–retest reliability of each method with intraclass correlation coefficient (1, 1). We evaluated the ability to estimate the radiographic measurement values from the OpenPose values using linear regression analysis and used intraclass correlation coefficients (2, 1) and Bland–Altman analyses to evaluate the agreement and error between OpenPose and radiographic measurements. OpenPose had excellent test–retest reliability (intraclass correlation coefficient (1, 1) = 1.000) and excellent agreement with radiography (intraclass correlation coefficient (2, 1) = 0.915), with regression analysis indicating a large correlation (R 2 = 0.865). OpenPose also had a 1.1° fixed error and no systematic error when compared with radiography. This is the first study to validate the use of OpenPose for the estimation of HKA angle in patients with knee osteoarthritis. OpenPose is a reliable and valid tool for measuring HKA angle in patients with knee osteoarthritis. OpenPose, which enables non-invasive and simple measurements, may be a useful tool to assess changes in HKA angle and monitor the progression and post-operative course of knee osteoarthritis. Furthermore, this validated tool can be used not only in clinics and hospitals, but also at home and in training gyms; thus, its use could potentially be expanded to include self-assessment/monitoring.
Background: A chronic expanding hematoma (CEH) is a rare complication caused by surgery or trauma; it mostly affects the soft tissues, such as those in the trunk or extremities. We present the first case of a large intraosseous CEH presenting with chronic disseminated intravascular coagulation (DIC), 22 years after total hip arthroplasty (THA); the CEH was treated with a single-stage excision and revision THA. Case presentation: A 67-year-old man presented to our hospital with left thigh pain and an enlarging mass. He had no history of trauma, anticoagulant use, or a collagen vascular disorder. The patient initially declined surgery. Two years later, radiographs and computed tomography images revealed progressive osteolysis, marginal sclerosis, and calcification in the left femur, in addition to loosening of the femoral component. Laboratory data revealed anemia and chronic DIC of unknown causes. Magnetic resonance imaging revealed a "mosaic sign"on the mass, indicating a mix of low- and high-signal intensities on T2-weighted images. Needle biopsy prior to surgery revealed no infection or malignant findings. An intraosseous CEH was suspected due to extensive osteolysis and loosening of the femoral component. No other factors that could induce chronic DIC were identified, such as sepsis, leukemia, cancer, trauma, liver disease, aneurysms, or hemangiomas. Therefore, we speculated that the anemia and chronic DIC were caused by the large intraosseous CEH. A single-stage revision THA with surgical excision was performed to preserve the hip function and improve the chronic DIC. The postoperative histopathological findings were consistent with an intraosseous CEH. The anemia and chronic DIC improved after 7 days. There was no recurrence of intraosseous CEH or chronic DIC at the 6-month follow-up. The left thigh pain improved, and the patient could ambulate with the assistance of a walking frame. Conclusions: The loosening of the femoral component caused persistent movement, which may have caused intraosseous CEH growth, anemia, and chronic DIC. It is important to differentiate CEHs from malignant tumors with hematomas. Furthermore, the "mosaic sign" noted in this case has also been observed on magnetic resonance images in other cases of CEH.
OBJECTIVES:Although both sarcopenia and hip disease decrease physical function, few studies have investigated the association. We investigated the prevalence of sarcopenia in patients awaiting total hip arthroplasty for osteoarthritis and examined the impact of sarcopenia on pre- and postoperative outcomes.METHODS:This prospective study included 96 females. Participants were classified using two criteria. Cases defined as having sarcopenia by the Asian Working Group for Sarcopenia (AWGS) criteria were categorized as the AWGS-sarcopenia (A-S) group, and others were categorized as the AWGS-non-sarcopenia (A-NS) group. Those classified by hand grip strength (HGS) constituted the lower-HGS (L-H) and normal-HGS (N-H) groups. Patient demographics, physical function, and Japanese Orthopaedic Association (JOA) score were compared between each group.RESULTS:The prevalence of the AWGS sarcopenia was 33.3%. In the pre- and postoperative analyses, the L-H group had significantly poorer physical function and JOA score than the N-H group. Postoperatively, the A-S group only demonstrated poorer HGS.CONCLUSION:Preoperative physical function and JOA score was significantly poorer in the L-H group; physical function was significantly poorer even postoperatively. A HGS test is useful for detecting a decline in the pre- and postoperative physical function in females with hip osteoarthritis.
Background: The purpose of this study was to evaluate true change in leg length after open-wedge high tibial osteotomy (OWHTO) using three-dimensional (3D) assessments, exam-ine the factors that influence leg lengthening and verify their validity in clinical practice. Methods: Study 1: a retrospective case series simulation study, included 46 patients (55 knees) that underwent knee arthroplasty or HTO. OWHTO was simulated from preopera-tive computed tomography using 3D preoperative planning software. Uni-and multivari-ate regression analyses were conducted to identify predictors related to change in leg length. Study 2: a retrospective case series study, included 53 patients (55 knees) that underwent OWHTO in another institution. Change in leg length was measured preopera-tively and 1 year postoperatively and was compared with the predicted change in leg length calculated using the formula obtained from Study 1. Results: Study 1: the true change in leg length significantly increased and showed a strong correlation with the opening width. The change in leg length was predicted using the formula "change in leg length = opening width x 0.75-1.5." Study 2: the predicted change in leg length showed no significant difference from the change in leg length 1 year postoperatively and a strong correlation with the measured change. Conclusions: The true change in leg length after OWHTO was predicted using the formula obtained from the 3D model. Predicting the change in leg length preoperatively can be a basis to consider other HTOs. (c) 2021 Elsevier B.V. All rights reserved.
Abstract Background We developed iodine-coated titanium implants to suppress microbial activity and prevent periprosthetic joint infection (PJI); their efficacy was demonstrated in animal and in vitro models. The iodine content in iodine-coated implants naturally decreases in vivo. However, to our knowledge, the effect of reduced iodine content on the implant’s antimicrobial activity has not been evaluated to date. Questions/purposes (1) How much does the iodine content on the implant surface decrease after 4 and 8 weeks in vivo in a rat model? (2) What effect does the reduced iodine content have on the antimicrobial effect of the implant against multiple bacteria in an in vitro model? Methods This experiment was performed in two parts: an in vivo experiment to determine attenuation of iodine levels over time in rats, and an in vitro experiment in which we sought to assess whether the reduced iodine content observed in the in vivo experiment was still sufficient to deliver antimicrobial activity against common pathogens seen in PJI. For the in vivo experiment, three types of titanium alloy washers were implanted in rats: untreated (Ti), surface-anodized to produce an oxide film (Ti-O), and with an iodine layer on the oxidation film (Ti-I). The attenuation of iodine levels in rats was measured over time using inductively coupled plasma-mass spectrometry. Herein, only the Ti-I washer was used, with five implanted in each rat that were removed after 4 or 8 weeks. For the 4- and 8-week models, two rats and 15 washers were used. For the in vitro study, to determine the antibacterial effect, three types of washers (Ti, Ti-O, and Ti-I) (nine washers in total) were implanted in each rat. Then, the washers were removed and the antibacterial effect of each washer was examined on multiple bacterial species using the spread plate method and fluorescence microscopy. For the spread plate method, six rats were used, and five rats were used for the observation using fluorescence microscopy; further, 4- and 8-week models were made for each method. Thus, a total of 22 rats and 198 washers were used. Live and dead bacteria in the biofilm were stained, and the biofilm coverage percentage for quantitative analysis was determined using fluorescence microscopy in a nonblinded manner. Ti-I was used as the experimental group, and Ti and Ti-O were used as control groups. The total number of rats and washers used throughout this study was 24 and 213, respectively. Results Iodine content in rats implanted with Ti-I samples decreased to 72% and 65% after the in vivo period of 4 and 8 weeks, respectively (p = 0.001 and p < 0.001, respectively). In the in vitro experiment, the Ti-I implants demonstrated a stronger antimicrobial activity than Ti and Ti-O implants in the 4- and 8-week models. Both the median number of bacterial colonies and the median biofilm coverage percentage with live bacteria on Ti-I were lower than those on Ti or Ti-O implants for each bacterial species in the 4- and 8-week models. There was no difference in the median biofilm coverage percentage of dead bacteria. In the 8-week model, the antibacterial activity using the spread plate method had median (interquartile range) numbers of bacteria on the Ti, Ti-O, and Ti-I implants of 112 (104 to 165) × 105, 147 (111 to 162) × 105, and 55 (37 to 67) × 105 of methicillin-sensitive Staphylococcus aureus (Ti-I versus Ti, p = 0.026; Ti-I versus Ti-O, p = 0.009); 71 (39 to 111) × 105, 50 (44 to 62) × 105, and 26 (9 to 31)× 105 CFU of methicillin-resistant S. aureus (Ti-I versus Ti, p = 0.026; Ti-I versus Ti-O, p = 0.034); and 77 (74 to 83) × 106, 111 (95 to 117) × 106, and 30 (21 to 45) × 106 CFU of Pseudomonas aeruginosa (Ti-I versus Ti, p = 0.004; Ti-I versus Ti-O, p = 0.009). Despite the decrease in the iodine content of Ti-I after 8 weeks, it demonstrated better antibacterial activity against all tested bacteria than the Ti and Ti-O implants. Conclusion Iodine-coated implants retained their iodine content and antibacterial activity against methicillin-sensitive S. aureus, methicillin-resistant S. aureus, and P. aeruginosa for 8 weeks in vivo in rats. To evaluate the longer-lasting antibacterial efficacy, further research using larger infected animal PJI models with implants in the joints of both males and females is desirable. Clinical Relevance Iodine-coated titanium implants displayed an antibacterial activity for 8 weeks in rats in vivo. Although the findings in a rat model do not guarantee efficacy in humans, they represent an important step toward clinical application.
Background: Locomotive syndrome (LS) is a predictive factor of future motor dysfunction. Our aim was to evaluate the change in the total LS grade and, its the association with the Japanese Orthopaedic Association (JOA) hip score after total hip arthroplasty (THA) among patients with hip osteoarthritis. Methods: This was a prospective caseecontrol study of 72 patients who underwent primary THA. The functional outcomes were measured before, and at 6 and 12 months after THA. LS was evaluated using the following tests: stand-up test, 2-step test, and 25-question Geriatric Locomotive Function Scale (GLFS-25). In addition, factors affecting the improvement of LS grade were examined. Results: Prior to THA, 7% and 93% of patients were classified as LS grades 1 and 2. At 6 months after THA, an improvement in the total LS grade was observed in 57% of patients, with this percentage further increasing to 65% at 1 year. Only the preoperative GLFS-25 was correlated with the preoperative JOA hip scores. The postoperative GLFS-25 and the two-step test were correlated with the postoperative JOA hip scores. The preoperative functional reach test (FRT) was significantly correlated with the total LS grade improvement. Conclusions: THA can improve the total LS grade in 65% of patients at 1 year postoperatively. Improvement was largely achieved in the first 6 months after THA, with a change from LS grade 2 to grade 1. FRT could be used an indicator of the total LS grade improvement. (C) 2020 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.
Background A few previous studies have investigated patient satisfaction after total hip arthroplasty (THA) according to the degree of pelvic deformity. This study compared patient-reported outcomes after primary THA for Crowe types III, IV and I dysplasia. Methods This retrospective, single-center, single-surgeon case-control study included patients who underwent primary THA between 2008 and 2016. We sent postal questionnaires to 38 patients with Crowe type III and IV dysplasia. Among the questionnaire respondents, 23 patients, excluding those with a follow-up period of < 1 year, were enrolled as the H group. The control group included 46 patients with Crowe type I, matched for sex, age, body mass index and surgical approach. To investigate the influence of femoral shortening osteotomy, the H group was divided according to whether femoral shortening osteotomy was performed. Ten patients underwent THA with femoral shortening osteotomy (FO group), while 12 patients underwent THA without femoral shortening osteotomy (N-FO group). Patient demographics, mean follow-up period, surgical information, pre- and postoperative leg length discrepancy (LLD), and perioperative complications were investigated. Clinical evaluations were performed using the Japanese Orthopaedic Association (JOA) scores, 36-item short-form survey (SF-36), net promotor score (NPS), visual analogue scale (VAS), and questionnaires. The VAS and SF-36 scores were determined only at final follow-up. Results The H and control groups were not significantly different in the postoperative JOA scores and SF-36. In the H group, VAS at the final follow-up was significantly higher, and significantly more patients felt that postoperative rehabilitation was serious, expressing that they underwent THA for LLD correction. In addition, the VAS scores in the FO group was higher than those in the N-FO group. Postoperative LLD was significantly greater in the H group than in the control group. Each group had an NPS of > 50. Conclusion The postoperative VAS score was higher in Crowe type III and IV dysplasia than in Crowe type I dysplasia, but no significant differences were detected in the postoperative satisfaction, JOA score, and SF-36 score. These findings may help explain the effects of THA preoperatively to patients with Crowe type III and IV dysplasia. Level of evidence Therapeutic Level 3b.
PurposeA computed tomography (CT)-based hip navigation system is a useful tool for achieving precise implant alignment angle. However, it has the disadvantage of prolonged procedure duration. A prolonged procedure duration may increase the incidence of postoperative surgical site infection (SSI) or periprosthetic joint infection (PJI) following primary THA. Studies identifying whether CT-based hip navigation system increases the incidence of SSI and PJI compared to the free-hand technique for total hip arthroplasty (THA) are rare. The study aimed to assess whether the CT-based hip navigation system can cause SSI and PJI compared to the free-hand technique.MethodsWe investigated 366 patients with osteoarthritis who completed the minimum 2-year follow-up and underwent primary THAs (n=435), including 70 hips in 62 patients of the non-navigation group and 365 hips in 304 patients of the navigation group. We compared the incidence rate of SSI and PJI between the non-navigation group and navigation group.ResultsOnly three patients in the navigation group (0.8%) developed SSI or PJI, while no patient developed SSI or PJI in the non-navigation group. There was no significant difference in the incidence rate of SSI or PJI between the two groups (P=1.0), although the mean operation time in the navigation group was about 20 min longer.ConclusionsCT-based hip navigation system may not be associated with SSI or PJI after primary THA, although it prolongs the operation time.
Background Subcutaneous adipose tissue represents an abundant source of multipotent adult stem cells named as Adipose-derived stem cells (ADSCs). With a cell sheet approach, ADSCs survive longer, and can be delivered in large quantities. We investigated whether intra-articular ADSC sheets attenuated osteoarthritis (OA) progression in a rabbit anterior cruciate ligament transection (ACLT) model. Methods Fabricating medium containing ascorbate-2-phosphate was used to enhance collagen protein secretion by the ADSCs to make ADSC sheets. At 4 weeks after ACLT, autologous ADSC sheets were injected intra-articularly into the right knee (ADSC sheets group), and autologous cell death sheets treated by liquid nitrogen were injected into the left knee (control group). Subsequent injections were administered once weekly. Femoral condyles were compared macroscopically and histologically. Results Macroscopically, OA progression was significantly milder in the ADSC sheets than in the control groups. Histologically, control knees showed obvious erosions in the medial and lateral condyles, while cartilage was retained predominantly in the ADSC sheets group. Immunohistochemically, MMP-1, MMP-13, ADAMTS-4 were less expressive in the ADSC sheets than in the control groups. Conclusions Periodic ADSC sheets injections inhibited articular cartilage degeneration without inducing any adverse effects. A large quantity of autologous ADSCs delivered by cell sheets homed to the synovium and protected chondrocytes.
Aims We analyzed the acetabular morphology of Crowe type IV hips using CT data to identify a landmark for the ideal placement of the centre of the acetabular component, as assessed by morphometric geometrical analysis, and its reliability. Patients and Methods A total of 52 Crowe IV hips (42 patients; seven male, 35 female; mean age 68.5 years (32 to 82)) and 50 normal hips (50 patients; eight male, 42 female; mean age 60.7 years (34 to 86)) undergoing total hip arthroplasty were retrospectively identified. In this CT-based simulation study, the acetabular component was positioned at the true acetabulum with a radiological inclination of 40° and anteversion of 20°. Acetabular shape and the position of the centre of the acetabular component were analyzed by morphometric geometrical analysis using the generalized Procrustes analysis. Results The acetabular shapes of Crowe IV hips were distinctively triangular; the ideal position of the centre of the acetabular component was superior on the posterior bony wall. The first and second relative warps explained 34.2% and 18.4% of the variance, respectively, compared with that of 28.6% and 18.0% in normal hips. We defined the landmark as one-third the distance from top on the posterior bony wall in Crowe IV hips. The average distance from the centre of the acetabular component was 5.6 mm. Conclusion Crowe IV hips are distinctively triangular; the point one-third from the top on the posterior bony wall was a useful landmark for placing the acetabular component.
Purpose: The mechanisms underlying thigh pain in patients with well-fixed cementless femoral components after total hip arthroplasty (THA) remains unclear. We hypothesized that the thigh pain is correlated with the initial contact state of the stem and aimed to investigate the relation between thigh pain and the initial contact state. Materials and methods: A total of 209 hips of 184 patients were analysed in this retrospective case–control study. The patients were divided into a thigh pain group ( n = 13 hips) and a control group (without thigh pain, n = 196). Post-operative stem contact images were three-dimensionally visualized by a density mapping function using computed tomography data, which quantified the stem contact area according to Gruen zones. Thigh pain was defined as anterior or anterolateral pain upon loading at 3-month post-operatively. Results: Thirteen hips (6.2%) had thigh pain; however, all the hips demonstrated stable bony ingrowth radiographically. The thigh pain group had a significantly lower contact area in zone 2 ( p = 0.014). The multivariate logistic regression analysis showed that the contact area of zone 2 was negatively correlated with thigh pain [odds ratio (OR): 0.858, p = 0.018], and the canal flare index was negatively correlated with the development of thigh pain (OR: 0.336, p = 0.026). Conclusions: We identified an association between the initial contact state and post-operative thigh pain. Our data demonstrated that proper lateral contact prevents the occurrence of thigh pain in THA using a tapered wedge stem.
This study investigated the influence of the rotation of innominate bone on anterior pelvic plane (APP) tilt, the angle formed by the APP, and coronal plane of the body to determine whether the provision of proper information about the sagittal balance of the body by the value of the APP tilt (APPT). In total, 244 patients (171 females, 73 males) who were candidates for total hip or knee arthroplasty, periacetabular osteotomy, or shelf arthroplasty were included. The rotational angle of the innominate bone was quantified using computed tomography images at the level of the anterior superior, and anterior inferior iliac spine, and ischiopubic portion. Clustering analysis was performed to identify subtypes of innominate bone rotation. High, intermediate, and low internal rotational alignment groups were identified in females, characterized by rotational angles. Males were treated as one group, and no intergroup differences were observed in sacral slope (SS) and pelvic incidence. However, intergroup differences in APPT were found, indicating a variation in APPT irrespective of sagittal body balance. A negligible relationship between SS and APPT was observed in the high-internal-rotation group, intermediate-internal-rotation group, and male group, whereas a moderate correlation found in the low-internal-rotation group (r = .59). The results could suggest surgeons that the value of the APPT provides no information on the sagittal balance; therefore, it may be ignored for acetabular component positioning during preoperative planning for total hip arthroplasty.
Background: The reduction of microbial infections can substantially improve the success of implant surgery. The iodine-supported implants that were developed by us for infection prevention were featured at the recent International Consensus Meeting on Musculoskeletal Infection and were partly incorporated into the consensus guidelines. For future clinical application, we examined (1) whether iodine can be added to metals with different surface roughness, (2) differences in surface roughness before and after processing, and (3) the effect of sterilization on the iodine content. Methods: Four Ti-6Al-4V metals were prepared with different surface roughness values by polishing, blasting and plasma spraying. Before and after processing, the surface structure of metals was observed using a scanning electron microscope and stylus instruments. Before and after sterilization, iodine contents were measured by X-ray fluorescence spectroscopy. Results: After processing, sufficient iodine contents with an antimicrobial effect were detected for each metal. These iodine contents decreased after sterilization but were higher than the lowest content of iodine observed to have an antimicrobial effect in a previous study, indicating that the antimicrobial effect persists even after sterilization. After processing, surface roughness was greater for polishing metal. With general surface processing, iodine processing was possible. Conclusions: Our results indicated that surface roughness is affected by the processing method and that the iodine content should be set according to the sterilization method. Considering these factors, iodine processing can be used for clinical applications. (C) 2020 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.
Background Intraoperatively acquired pressure ulcers are serious postsurgical complications requiring additional treatment, reoperation, and extended hospitalization. No study has investigated the frequency of the ulcers caused by compression with a pelvic positioner, which is used in hip surgeries to stabilize patients in the lateral decubitus position. Methods This retrospective study investigated the risk factors and the frequency of the ulcers caused by the use of pelvic positioners in hip surgeries. The records of patients who underwent surgical procedures under general anesthesia at our institution between January 1, 2016 and March 31, 2018 were reviewed. The inclusion criterion for the assessment of risk factors was hip surgery in the lateral decubitus position stabilized by a pelvic positioner. The exclusion criteria were patients with trauma, missing data, or a pre-existing pressure ulcer. Finally,.the study included 229 patients (265 hip surgeries). All the patients were positioned in the lateral decubitus position with the assistance of either a pelvic positioner, which had a single support fixture located over the pubic symphysis or a double support fixture located over the bilateral anterior superior iliac spine. Intraoperatively acquired pressure ulcers were diagnosed when ulcers were absent on admission and the redness that was observed immediately after surgery remained after 24 h. Multivariate analysis was used to identify factors associated with an increased risk for ulcers. Results Ulcers developed in 8 of 1810 (0.44%) patients who underwent orthopedic surgery. Seven of the 265 (2.64%) patients who underwent hip surgery in the lateral decubitus position stabilized by a pelvic positioner developed ulcers. All ulcers were located on areas of the body that were compressed by the pelvic positioner. After identifying controls for patient height (less than 154 cm), surgery duration (longer than 180 min), blood loss (more than 355 ml), and type of pelvic positioner used, we identified the independent risk factors for ulcers to be patient height < 154 cm (adjusted odds ratio, 12.8; p -value, 0.032) and the use of pelvic positioners with pubic bone support (adjusted odds ratio, 10.53; p-value, 0.047). Conclusion The use of pelvic positioners with pubic bone support should be avoided in patients with a height of < 154 cm to decrease the risk of ulcers.
BackgroundThere is limited understanding of anterior acetabular component overhang, which induces groin pain, in post-periacetabular osteotomy (PAO) hips during conversion to total hip arthroplasty (THA). The aim of the study were to determine the following: (1) the differences in the amount of acetabular component overhang among pre-PAO hips and post-PAO hips in simulating THA; (2) the factors associated with the amount of component overhang in THA following PAO; (3) whether high component placement with elevation of the hip center by 10 mm reduces the amount of component overhang compared to the anatomical component position in THA following PAO.MethodsComputer-based simulations of acetabular component implantation were performed using preoperative and postoperative CT data from 30 patients undergoing PAO. Implantation was performed thrice in each patient: in pre-PAO hips (anatomical component position) and post-PAO hips (anatomical and high component position). Component overhang was measured on the axial plane, which passes through the component center.ResultsOverhang was greater in post-PAO hips [mean (SD) overhang: 5.2 (2.9) mm, pre-PAO hips: 10.2 (4.6) mm, post-PAO hips-mean difference, 5.0 mm; p<0.001]. A smaller distance between the pubic osteotomy and the acetabulum, and greater overhang in pre-PAO hips was independent factors associated with increased overhang in post-PAO hips. Overhang was smaller with the high component position than with the anatomical component position in post-PAO hips [mean (SD) overhang-3.5 mm (2.9) with high component position among post-PAO hips; mean difference, 6.6 mm; p<0.001). Ten post-PAO hips with the anatomical component position had overhang of at least 12 mm (the likely threshold for groin pain). Of these, 9 hips had reduced overhang (<12 mm) with the high component position.ConclusionsAcetabular component overhang was more severe in THA following PAO than in THA without prior PAO. Pubic osteotomy should be performed closer to the acetabular rim to prevent severe overhang in potential THA conversion cases. A high component position decreased the risk of severe overhang.
Abstract In total knee arthroplasty, the surgical transepicondylar axis (SEA) is one of the most reliable rotation axes for stabilizing of the patellofemoral joint. The SEA is identified with reference to the lateral epicondyle and the medial sulcus of the medial epicondyle. However, these two structures rarely appear on the same plane on computed tomography (CT), and it is necessary to take two points in separate images. Many surgeons measure the SEA on the same image (pseudo SEA) instead. We aimed to determine the difference between true SEAs and pseudo SEAs. A total of 31 normal knees and 24 varus knees were included in this study. Three-dimensional (3D) models of the femur were reconstructed from CT images, and a reconstructed plane was made using the International Society of Biomechanics coordinate system. Pseudo SEAs drawn in the plane passing through the lateral epicondyle and medial sulcus were defined as l-SEA and m-SEA, respectively. L-SEA, m-SEA, true SEA, and posterior condylar axis (PCA) were projected onto the International Society of Biomechanics coordinate plane and, “p l-SEA,” “p m-SEA,” “p true SEA,” and “p PCA” were obtained. The true SEA angle was defined as the angle between p true SEA and p PCA. The l-SEA angle or m-SEA angle was defined as the angle between the p l-SEA or p m-SEA and p PCA, respectively. There were no statistically significant differences between true SEA angle (2.64 ± 2.01 degrees) and pseudo SEA angle (l-SEA angle: 2.74 ± 2.07 degrees, m-SEA: 2.54 ± 2.19 degrees). Conversely, 12 knees in the normal group and 2 knees in the varus group had differences of more than 1 degree (p = 0.01). Among them, 6 knees in the normal group and 0 knees in the varus group had a difference of 2 degrees or more (p = 0.03). In most cases, pseudo SEA can be substituted for true SEA.
BACKGROUND:Clinical outcomes of total hip arthroplasty (THA) for Crowe type IV are poorer than for Crowe type I, because it is more difficult to accurately position the acetabular components. This study aimed to examine the accuracy of the computed tomography (CT)-based navigation system for acetabular component positioning in primary THA for Crowe type IV. METHODS:From 2006 to 2018, 29 patients who underwent 34 primary THAs for Crowe type IV were enrolled in the "Type IV" group and 32 patients who underwent 34 THAs for Crowe type I were enrolled in the "Type I" group, formed by matching patients in the Type IV group on age, gender, body mass index, and surgical approach. We investigated (1) the accuracy of the cup size between that at preoperative planning and that actually implanted and (2) the mean deviation of the cup angle and 3-dimensional position of acetabular components between preoperative plan and postoperative records. RESULTS:The accuracy of the cup size was 79.4% and 94.1% in the Type IV and Type I groups, respectively, without a statistically significant change detected (P = .075). The mean deviations of the cup angle and 3-dimensional position were comparable in both groups. CONCLUSION:Using the CT-based navigation system, it was possible to accurately implant the acetabular component for Crowe type IV, and the accuracy was comparable to that for Crowe type I. The CT-based navigation system is a useful intraoperative tool to accurately implant the acetabular component, especially with severe pelvic deformities such as Crowe type IV.
Background: In total hip arthroplasty, the minimum host bone coverage required on the cup for stable fixation has been previously reported; however, the coverage was generally evaluated on a 2-dimensional (2D) image and 3-dimensional (3D) coverage has not been well described. Methods: We used postoperative computed tomography images to retrospectively measure 3D cup coverage in 151 hips with developmental dysplasia of the hip that underwent primary total hip arthroplasty. The aims were to (1) determine the minimum requirement of the 3D coverage for stable cup fixation; (2) evaluate the relationship between 2D and 3D coverage; and (3) identify the factors associated with 2D-3D discrepancy, defined as follows: 2D-3D discrepancy = 2D coverage -3D coverage. Results: All cups showed stable fixation as demonstrated by bone ingrowth with an average postoperative period of 48 months. The minimum 3D coverage was 61.2%, with a mean value of 77.1% +/- 6.7% and maximum value of 97.6%. We found a significant positive but poor relationship between 3D and 2D coverage (bone coverage index; r = 0.30). Consequently, the 2D-3D discrepancy varied greatly, with a mean value of -1.6% +/- 12.3% (range, -36.5% to 32.2%). Multiple linear regression analyses confirmed that lower cup center and anterior tilt of the pelvis relative to the computed tomography table were independent factors associated with increasing 2D-3D discrepancy. Conclusion: This study showed that 2D coverage, measured on a projected image, carries a risk of overestimation, especially in hips with the aforementioned features. (C) 2018 Elsevier Inc. All rights reserved.