The retention behavior in supercritical fluid chromatography (SFC) remains a complex and poorly understood phenomenon despite the development of various models to explain retention mechanisms. This study aims to deepen the understanding of retention by investigating three distinct stationary phases: high-strength silica octadecyl (HSS C18 SB), charged surface hybrid pentafluorophenyl (CSH PFP), and porous graphitic carbon (PGC) as a nonsilica-based phase. Three mobile phase compositions, i.e., CO2/methanol, CO2/methanol +10 mmol/L NH3, and CO2/methanol +2% H2O, were investigated using an extensive set of analytes characterized by over 200 molecular descriptors. Artificial neural networks were employed to analyze the influence of these descriptors on retention behavior, revealing the most significant molecular features that increase or decrease retention on each column with the three different mobile phases. This complex evaluation of the large set of experimental data enabled to link specific analyte properties to retention interactions in SFC, including the interaction of analytes with partial positive charge with silanol groups on the HSS C18 SB column when using methanol + H2O as the organic modifier. The flexibility of the alkyl chain in the HSS C18 SB column is also affected by the composition of the organic modifier, which alters retention mechanisms, especially when NH3 is used as an additive. This highlights the critical role of the mobile phase composition in modulating the behavior of nonpolar stationary phases. Completely different interaction mechanisms were observed for the PGC column when comparing methanol with and without additives, suggesting possible modifications to the planar structure and surface polarizability of the PGC phase. Statistical evaluation of data collected over a year of column usage demonstrated distinct long-term retention stability trends. The HSS C18 SB column exhibited the greatest stability with methanol + H2O, whereas significant retention decreases were observed with methanol + NH3 modifier, particularly for CSH PFP and, unexpectedly, also for PGC. These findings provide crucial insights into the long-term retention behavior and aging of SFC columns, with practical implications for optimizing SFC conditions and improving column lifetime.
Elevating the column temperature is an effective strategy for improving the chromatographic separation of peptides. However, high temperatures induce artificial modifications that compromise the quality of the peptide analysis. Here, we present a novel high-temperature LC-MS method that retains the benefits of a high column temperature while significantly reducing peptide modification and degradation during reversed-phase liquid chromatography. Our approach leverages a short inline trap column maintained at a near-ambient temperature installed upstream of a separation column. The retentivity and dimensions of the trap column were optimized to shorten the residence time of peptides in the heated separation column without compromising the separation performance. This easy-to-implement approach increased peak capacity by 1.4-fold within a 110 min peptide mapping of trastuzumab and provided 10% more peptide identifications in exploratory LC-MS proteomic analyses compared with analyses conducted at 30 °C while maintaining the extent of modifications close to the background level. In the peptide mapping of biopharmaceuticals, where in-column modifications can falsely elevate the levels of some critical quality attributes, the method reduced temperature-related artifacts by 66% for N-terminal pyroGlu and 63% for oxidized Met compared to direct injection at 60 °C, thus improving reliability in quality control of protein drugs. Our findings represent a promising advancement in LC-MS methodology, providing researchers and industry professionals with a valuable tool for improving the chromatographic separation of peptides while significantly reducing the unwanted modifications.
The retention behavior in supercritical fluid chromatography and its stability over time are still unsatisfactorily explained phenomena despite many important contributions in recent years, especially focusing on linear solvation energy relationship modeling. We studied polar stationary phases with predominant -OH functionalities, i.e., silica, hybrid silica, and diol columns, and their retention behavior over time. We correlated molecular descriptors of analytes with their retention using three organic modifiers of the CO2-based mobile phase. The differences in retention behavior caused by using additives, namely, 10 mmol/L NH3 and 2% H2O in methanol, were described in correlation to analyte properties and compared with the CO2/methanol mobile phase. The structure of >100 molecules included in this study was optimized by semiempirical AM1 quantum mechanical calculations and subsequently described by 226 molecular descriptors including topological, constitutional, hybrid, electronic, and geometric descriptors. An artificial neural networks simulator with deep learning toolbox was trained on this extensive set of experimental data and subsequently used to determine key molecular descriptors affecting the retention by the highest extent. After comprehensive statistical analysis of the experimental data collected during one year of column use, the retention on different stationary phases was fundamentally described. The changes in the retention behavior during one year of column use were described and their explanation with a proposed interpretation of changes on the stationary phase surface was suggested. The effect of the regeneration procedure on the retention was also evaluated. This fundamental understanding of interactions responsible for retention in SFC can be used for the evidence-based selection of stationary phases suitable for the separation of particular analytes based on their specific physicochemical properties.
Background Reliable quantification of multiple steroid classes in biological fluids within a single method remains an analytical challenge despite many previously published methods. Crosstalk of positional isomers, overlap of stereoisomer fragmentation patterns, differing proton affinities, in-source fragmentation, varying stability of protonated ions in the gas phase across steroid classes, and non-existence of steroid-free matrix are the main challenges limiting the number of simultaneously profiled steroids. Results In this study, we focused on the development of a derivatization-free, achiral, high-throughput, and cost-effective UHPLC-MS/MS approach that allows simultaneous profiling of a spectrum of 38 steroids covering progestogens, androgens, corticosteroids, and estrogens, while properly addressing the hurdles of steroid analysis. Within a 20-min method, 16 stereoisomers and 15 positional isomers were fully resolved within a single run while separated from 7 additional non-interfering steroids and matrix interferences in rodent plasma. Protein precipitation (PP) and supported liquid extraction (SLE) methods using only 40 μL of sample were developed to achieve the lowest possible limits of quantification. Nevertheless, 5α-dihydroprogesterone and 3α,5α-THDOC could be only qualitatively assessed when using PP. In contrast, DHEA-S could not be quantified or identified when using SLE. A novel surrogate matrix-background subtraction approach, using rat plasma after the animal's adrenalectomy, has been implemented into the optimized PP-UHPLC-MS/MS workflow, successfully validated according to the unified ICH/EMA M10 guidelines, and compared to the traditional quantification strategies. Moreover, the validity of the newly adopted approach has been verified by the targeted profiling of multiple biologically active endogenous steroids in more than 500 samples of mouse plasma in total. Significance Underestimation of hurdles associated with steroid analysis often compromises the accurate steroid quantification. Our comprehensive, fully validated UHPLC-MS/MS method targeting a wide spectrum of endogenous steroids, mitigating steroid crosstalk and using a minimal sample volume together with a novel surrogate matrix-background subtraction approach significantly advances steroid analysis for research and clinical applications covering multiple biological scopes.
Microbiota plays a role in shaping the HPA-axis response to psychological stressors. To examine the role of microbiota in response to acute immune stressor, we stimulated the adaptive immune system by anti-CD3 antibody injection and investigated the expression of adrenal steroidogenic enzymes and profiling of plasma corticosteroids and their metabolites in specific pathogen-free (SPF) and germ-free (GF) mice. Using UHPLC-MS/MS, we showed that 4 hours after immune challenge the plasma levels of pregnenolone, progesterone, 11-deoxycorticosterone, corticosterone (CORT), 11-dehydroCORT and their 3α/β-, 5α-, and 20α-reduced metabolites were increased in SPF mice, but in their GF counterparts, only CORT was increased. Neither immune stress nor microbiota changed the mRNA and protein levels of enzymes of adrenal steroidogenesis. In contrast, immune stress resulted in downregulated expression of steroidogenic genes (Star, Cyp11a1, Hsd3b1, Hsd3b6) and upregulated expression of genes of the 3α-hydroxysteroid oxidoreductase pathway (Akr1c21, Dhrs9) in the testes of SPF mice. In the liver, immune stress downregulated the expression of genes encoding enzymes with 3β-hydroxysteroid dehydrogenase (HSD) (Hsd3b2, Hsd3b3, Hsd3b4, Hsd3b5), 3α-HSD (Akr1c14), 20α-HSD (Akr1c6, Hsd17b1, Hsd17b2) and 5α-reductase (Srd5a1) activities, except for Dhrs9, which was upregulated. In the colon, microbiota downregulated Cyp11a1 and modulated the response of Hsd11b1 and Hsd11b2 expression to immune stress. These data underline the role of microbiota in shaping the response to immune stressor. Microbiota modulates the stress-induced increase in C21 steroids, including those that are neuroactive that could play a role in alteration of HPA axis response to stress in GF animals.
Searchable abstracts of presentations at key conferences in endocrinology ISSN 1470-3947 (print) | ISSN 1479-6848 (online)
Within this review, we thoroughly explored supercritical fluid chromatography (SFC) columns used across > 3000 papers published from the first study carried out under SFC conditions in 1962 to the end of 2022. We focused on the open tubular capillary, packed capillary, and packed columns, their chemistries, dimensions, and trends in used stationary phases with correlation to their specific interactions, advantages, drawbacks, used instrumentation, and application field. Since the 1990s, packed columns with liquid chromatography and SFC-dedicated stationary phases for chiral and achiral separation are predominantly used. These stationary phases are based on silica support modified with a wide range of chemical moieties. Moreover, numerous unconventional stationary phases were evaluated, including porous graphitic carbon, titania, zirconia, alumina, liquid crystals, and ionic liquids. The applications of unconventional stationary phases are described in detail as they bring essential findings required for further development of the supercritical fluid chromatography technique.
The effect of makeup solvent composition in ultrahigh-performance supercritical fluid chromatography-triple quadrupole mass spectrometry using electrospray ionization was studied using a set of 91 compounds, 3 stationary phases, and 2 organic modifiers of the mobile phase. The 24 tested makeup solvents included pure alcohols and methanol in combination with commonly used additives such as water, formic and acetic acid, ammonia, and ammonia salts with varying molarity. The behavioral trends for different makeup solvent additives were established in the first step. Subsequently, the correlations between physicochemical properties and the MS responses were calculated using the Pearson correlation test and matrix plots. The regression analysis was performed using five descriptors: molecular weight, pKa, log P, number of hydrogen donors/acceptors, and the MS responses obtained with methanol as the makeup solvent. The resulting regression equations had a high prediction rate calculated as R2-predicted coefficient, especially when 10 mmol/L ammonium in methanol was used as an organic modifier of the mobile phase in positive mode. The trueness of these equations was tested via the comparison between experimental and predicted responses expressed as R2. Values of R2 > 0.8 were found for 88% of the proposed equations. Thus, the MS response could be measured using only one makeup solvent and the responses of other makeup solvents could be easily estimated. The suitability and applicability of determined regression equations was confirmed by the analysis of 13 blind probes, i.e., compounds not included in the original set of analytes. Moreover, the predicted and experimental responses followed the same increasing/decreasing trend enabling one to predict makeup solvent compositions leading to the highest sensitivity.
Searchable abstracts of presentations at key conferences in endocrinology ISSN 1470-3947 (print) | ISSN 1479-6848 (online)
Similarly to other hyphenated techniques, supercritical fluid chromatography (SFC) highly benefits from the coupling with mass spectrometry (MS) detection as evident from the increasing number of published SFC-MS methods. SFC-MS is nowadays routinely used in numerous application fields and experimentally investigated in many others. The selection of mass analyzers in SFC relies on the same principles as in both liquid and gas chromatography. The overview of published studies revealed that more than 70% of the SFC-MS analyzes are carried out using electrospray ionization, while atmospheric pressure photoionization remains largely neglected. This review aims to describe challenges and principles of the selections of suitable interface considering used ion source and chromatographic conditions. Moreover, differences arising from using SFC contrary to liquid chromatography with atmospheric pressure ionization sources are described. Matrix effect issues in SFC-MS are summarized here as well as the overall applicability across analytical fields.
Gastrointestinal stromal tumours (GISTs) are the major nonepithelial neoplasms of the human gastrointestinal tract with a worldwide incidence between 11 and 15 per million cases annually. In this study the acid and non-acid glycosphingolipids of three GISTs were characterized using a combination of thin-layer chromatography, chemical staining, binding of carbohydrate recognizing ligands, and mass spectrometry. In the non-acid glycosphingolipid fractions of the tumors globotetraosylceramide, neolactotetraosylceramide, and glycosphingolipids with terminal blood group A, B, H, Le x , Le a , Le y and Le b determinants were found. The relative amounts of these non-acid compounds were different in the three tumour samples. The acid glycosphingolipid fractions had sulfatide, and the gangliosides GM3, GD3, GM1, Neu5Acα3neolactotetraosylceramide, GD1a, GT1b and GQ1b. In summary, we have characterized the glycosphingolipids of GISTs and found that the pattern differs in tumours from different individuals. This detailed characterization of glycosphingolipid composition of GISTs could contribute to recognition of new molecular targets for GIST treatment and sub-classification.