In the United States, standardization of neonatal extracorporeal membrane oxygenation (ECMO) circuit was achieved during the 1980s. Since that time, the consoles and components of the ECMO circuit have remained fundamentally unchanged (bladder, rollerpump, silicone membrane oxygenator). Extracorporeal technology, however, has witnessed many significant advancements in components during the past two decades. These new technologies have characteristics that may improve outcomes when applied in the ECMO arena. Understanding how these technologies perform in long-term applications is necessary. Therefore, the purpose of this project is to evaluate the performance of a miniature ECMO circuit consisting of current generation technologies in an animal model. An ECMO circuit (prime volume 145 mL) was designed that included a hollow fiber oxygenator and a remote mounted centrifugal pump. All circuit tubing and components were surface coated. Three sheep (approx 13 kg) were placed on ECMO using standard neck cannulation techniques and maintained according to clinical protocols. Technical implementation, oxygenator function, and hematological parameters were accessed. Duration of ECMO was 20, 48, and 58 hours. There was no evidence of oxygenator failure, as measured by pressure drop and oxygen transfer, in any of the procedures. No plasma leak was observed in any oxygenators. Platelet count trended downward after 24 hours. Visual inspection after ECMO showed very little evidence of gross thrombosis. This ECMO circuit design departs dramatically from the typical North American systems. The use of this console and components facilitated a 70% reduction in priming volume over a traditional ECMO circuit. Further investigations should be conducted to determine if circuit miniaturization can reduce the morbidity associated with blood product consumption and the bloods contact with the artificial surfaces of the ECMO circuitry.
In infants, technologies for obtaining rapid, quantified measurements of cardiac output (CO) following weaning from cardiopulmonary bypass (CPB) or extracorporeal membrane oxygenation are not readily available. A new technique to measure CO based on ultrasound velocity dilution is described. It utilizes reusable probes placed on the extracorporeal circuit that permits convenient measurement of CO prior to decannulation. This report provides preliminary validation data in an animal model.Three Yorkshire pigs (11-14 kg) were fully heparinized and cannulated via the right common carotid artery (cannula advanced to the aortic arch) and right atrium. Both the venous and arterial lines were instrumented with ultrasonic probes connected to a computer-monitoring system. A 'stopcock bridge' between the arterial and venous cannulas provided the access for saline injection and a controlled AV-shunt. For comparison, a vascular flow probe was fitted directly to the pulmonary artery (PA) in both animals and, for the larger animal, a PA catheter was inserted to obtain standard thermodilution measurements.Linear regression analysis revealed a correlation between the CO by ultrasound dilution (CO UD) technique and the vascular probe and PA thermodilution techniques to be R-2=0.94 and 0.81.This pilot study demonstrated that the CO UD technique correlates to other benchmarks of CO measurements. This novel technology has specific application in the field of pediatric open heart surgery in that it would allow the surgeon to accurately and inexpensively measure the CO of neonatal and pediatric patients before and after surgical manipulation of the heart without the need for placement of additional catheters or probes.
Over the past 20 years, the bulk of the literature and texts published about extracorporeal membrane oxygenation (ECMO) has been written by physicians and nurses. The consensus of this body of printed information would suggest, among other things, that (1) despite significant advancements in extracorporeal technology, the standard ECMO circuit has remained fundamentally unchanged since originally described in 1982, and (2) perfusionists are nearly absent from the staffing algorithm at most centers. While these conclusions may be representative of the extracorporeal life support (ELSO) reporting centers, they may not be representative of the field as a whole. We hypothesized that the use of modern extracorporeal equipment and the involvement of perfusionists in ECMO patient care is largely underreported in previous studies. To study this hypothesis, we developed a standard survey instrument and queried perfusion teams from the hospitals listed on the American Society of Extra-Corporeal Technology Pediatric Registry. All centers were contacted by phone and were asked questions regarding their caseload, circuitry, and staffing algorithms. Data are reported as a percentage of respondents. ECMO is used as a method of mechanical support after neonatal open heart surgery in 94% of centers surveyed. For 60% of the centers, a silicone membrane oxygenator is used exclusively, whereas 40% of the centers have used a hollow fiber oxygenator (HFO), and of that group, 19% use a HFO routinely for neonatal post-cardiopulmonary bypass ECMO. Roller pumps are used exclusively at 65% of the centers, whereas centrifugal pumps are used routinely in 12%, and 23% have used both. Perfusionists are responsible for set-up/initiation (79%) and daily rounding/troubleshooting (71%), and provide around-the-clock bedside care (46%) at the surveyed centers. These data suggest that previously published ELSO-centric ECMO studies may significantly underestimate the contemporary application of modern technologies and the involvement of perfusionists.