Extended abstract of a paper presented at Microscopy and Microanalysis 2010 in Portland, Oregon, USA, August 1 – August 5, 2010.
An ion mobility-mass spectrometry technique for rapid screening of phosphopeptides in protein digests is described. A data set of 43 sequences (ranging in mass from 400 to 3000 m/z) of model and tryptic peptides, including serine, threonine, and tyrosine phosphorylation, was investigated, and the data support our previously reported observation (Ruotolo, B. T.; Verbeck, G. F., IV; Thomson, L. M.; Woods, A. S.; Gillig, K. J.; Russell, D. H. J. Proteome Res. 2002, 1, 303.) that the drift time-m/z relationship for singly charged phosphorylated peptide ions is different from that for nonphosphorylated peptides. The data further illustrate that a combined data-dependent IM-MS/MS approach for phosphopeptide screening would have enhanced throughput over conventional MS/MS-based methodologies.
A prototype gas chromatograph (GC) electron monochromator (EM) reflectron time-of-flight (TOF) mass spectrometer has been constructed and demonstrated to simultaneously record four-dimensional resonant electron capture (REC) mass spectra (m/z, ion-intensity, electron-energy, and retention time) of electron-capturing compounds in real time. Specifically, complete REC mass spectra of all of the components in a mixture of perfluorocarboxylic acids and in a sample of pentafluorobenzyl alcohol were recorded in the GC mode. For each compound, the data enable one to distinguish different electronic states of the molecular ion and different possible decomposition pathways for each state. This new instrument can be used to obtain analytical information unrecognizable by any other mass spectrometric technique from the isomeric species of a variety of electron-capturing structures.
A prototype electron monochromator (EM) reflectron time-of-flight (TOF) mass spectrometer has been constructed and demonstrated to record resonant electron capture (REC) mass spectra of electron-capturing compounds. The electron energy is ramped from -1.7 to +25 eV at a preset frequency, and the energy spread of the electron beam at 15 nA is 100 meV or better. Ions are orthogonally extracted into the analyzer at a frequency of up to 80 kHz while maintaining an upper m/z-limit of at least 300 and a mass resolving power of approximately 1000. A complete REC mass spectrum, which includes an effective yield versus electron energy curve for each negative ion formed from the compound being analyzed, typically takes several days to produce with a quadrupole or magnetic sector mass spectrometer. With the EM TOF described in this work, three-dimensional negative ion electron capture spectra are recorded in an interval on the order of only 1 s and displayed in real time. This new analytical capability could make it possible to perform GC REC mass spectrometry as well as easier (a) to measure the temperature dependence of REC cross sections, (b) to determine enthalpies of negative ion formation (accurate determination of the enthalpy of ion formation requires knowledge of the translational energy released during a dissociative capture event), and (c) to provide complete thermochemical descriptions of dissociative electron attachment by measuring ion lifetimes.
A simple, rapid technique is described for detecting 0.8 μg or more of carbon. The sample is ignited in oxygen and the resulting carbon dioxide reacts with barium hydroxide to form barium carbonate. The carbon dioxide normally present in air has been an impediment in ignition methods for detecting microgram quantities of carbon. In the described technique the use of self-sealing rubber stoppers and hypodermic syringes and needles permit the necessary manipulations with the complete exclusion of air.