Background Initial studies of stereotactic body radiation therapy (SBRT) for refractory ventricular tachycardia (VT) have demonstrated impressive efficacy. Follow-up analyses have found mixed results and the role of SBRT for refractory VT remains unclear. We performed palliative, cardiac radio ablation in patients with ventricular tachycardia refractory to ablation and medical management. Methods Arrhythmogenic regions were targeted by combining computed tomography imaging with electrophysiologic mapping with collaboration from a radiation oncologist, electrophysiologist and cardiac imaging specialist. Patients were treated with a single fraction 25 Gy. Total durations of VT, the quantity of antitachycardia pacing (ATP) and shocks before and after treatment as recorded by implantable cardioverter-defibrillators (ICDs) were analyzed. Follow-up extended until most recent device interrogation unless transplant, death or repeat ablation occurred sooner. Results Fourteen patients (age 50–78, four females) were treated and had an average of two prior ablations. Nine had ACC/AHA Stage D heart failure and three had left ventricular assist devices (LVAD). Two patients died shortly after SBRT, one received a prompt heart transplant and another had significant VT durations in the following months that were inaccurately recorded by their device. Ten of the 14 patients remained with adequate data post SBRT for analysis with an average follow-up duration of 216 days. Seven of those 10 patients had a decrease in VT post SBRT. Comparing the 90 days before treatment to cumulative follow-up, patients had a 59% reduction in VT, 39% reduction in ATP and a 60% reduction in shocks. Four patients received repeat ablation following SBRT. Pneumonitis was the only complication, occurring in four of the fourteen patients. Conclusion SBRT may have value in advanced heart failure patients with refractory VT acutely but the utility over long-term follow-up appears modest. Prospective randomized data is needed to better clarify the role of SBRT in managing refractory VT.
Initial studies of stereotactic body radiation therapy (SBRT) for refractory ventricular tachycardia (VT) demonstrated impressive efficacy. Follow-up analyses have found mixed results and the role of SBRT for refractory VT remains unclear. We performed palliative, cardiac radio ablation in patients with ventricular tachycardia refractory to ablation and medical management.
BACKGROUND:Hands-on defibrillation (HOD) could theoretically improve the efficacy of cardiopulmonary resuscitation (CPR) though a few mechanisms. Polyethylene drapes could potentially facilitate safe HOD, but questions remain about the effects of CPR on polyethylene's conductance and the magnitude of current looping through rescuers' arms in contact with patients. METHODS:This study measured the leakage current through 2 mil (0.002 in.) polyethylene through two different current pathways before and after 30 min of continuous compressions on a CPR mannequin. The two pathways analyzed were the standardized IEC (International Electrotechnical Commission) leakage current analysis and a setup analyzing a current pathway looping through a rescuer's arms and returning to the patient. First, ten measurements involving the two pathways were obtained on a single polyethylene drape. 30 min of continuous compressions were applied to the drape on a CPR mannequin after which the ten measurements were repeated. RESULTS:Twenty patients undergoing elective cardioversion for atrial fibrillation (18/20) or atrial flutter (2/20) at Emory University Hospital underwent analysis all receiving 200 J shocks (age 38-101, 35% female). Through the IEC measurement method the peak leakage current mean was 0.70 +/- 0.02 mA before compressions and 0.59 +/- 0.19 mA after compressions. Only three of the ten measurements assessing current passing through a rescuer's arms had detectable current and each was of low magnitude. All measurements were well below the maximum IEC recommendations of 3.5 mA RMS and 5.0 mA peak. CONCLUSIONS:Polyethylene may facilitate safe HOD even after long durations of compressions. Current looping through a rescuer's arms is likely of insignificant magnitude.