In this article, the mechanical characterization of a monolithic cup made of BIOLOXdelta with a porous ceramic coating for osseointegration is presented. During the coating process, a ceramic slurry is deposited on a green substrate, both slurry and substrate are based on BIOLOXdelta. To achieve a porous coating, organic pore-forming agents were used which are pyrolized in the following sintering process. Porosities of 18 to 47% could be reached depending on the layer thickness. Extensive mechanical investigations were applied on the fabricated cups to verify the suitability of the produced porous layers for biomechanical demands of the interface between bone and dense substrate. The test results showed that coated ceramic cups require comparable push out forces for the disconnection from artificial bone to established metal shells with plasma sprayed titanium coatings.
AIM OF THE STUDY:Total disc arthroplasty is reported to maintain segmental motion. From finite element studies a rather posterior and central implantation of the prosthesis is recommended. However, there is yet no in vitro study with cadaveric specimens investigating the topic of implant positioning.METHODS:Ten human lumbar spines were subjected to biomechanical testing. Flexion/extension and side-bending moments were applied from 2.5-7.5 Nm on a spine load simulator. First, the intact specimens were tested in 3 load cycles while motion was monitored with regard to the facet joints under different loads by an ultrasound-based system. An unconstrained total disc prosthesis was then implanted in a central position and the different load cycles were repeated. Finally the implant was positioned in a decentral position with an average offset of 6.2 mm for repetitive data acquisition.RESULTS:Comparison of the facet joint motion in central and eccentric prosthesis positions resulted in the following averaged differences. During flexion of the lumbar spine an average difference of the reference point excursions of 0.38 mm was recorded on the ipsilateral facet joint with reference to the decentral position. For extension, the difference was 0.33 mm on average, for right side bending a difference of 0.63 mm was recorded while left side bending resulted in an average difference of 0.24 mm. The deviation of the reference markers on the contralateral facet joint showed the following average differences: for flexion 0.23 mm and for extension 0.54 mm, respectively. For side bending right/left the differences amounted to 0.18 mm and 0.39 mm. With regard to segmental motion there was no statistically significant difference for both the ipsilateral (p = 0.0564) and the contralateral (p = 0.2593) reference marker.CONCLUSIONS:The comparison of the segmental motion after central and decentral implantation of a lumbar total disc prosthesis reveals differences that have, nevertheless, no statistical significance. However, for clinical use it is recommended to strive for a central position of the implant.
Alumina (Al2O3) bearings in total hip arthroplasty lead to low wear rates, but catastrophic failure of Al2O3 femoral heads, while rare, remains a concern. In the present work, a composite of Al2O3 and niobium (Nb) was tested in vitro for potential use as an alternative femoral head material in vivo. Dense composite laminates of Al2O3 and Nb were fabricated by hot pressing, and their microstructure and mechanical properties were evaluated. The flexural strength of Al2O3–Nb laminates in four-point loading was 720 ± 40 MPa, compared with a value of 460 ± 110 MPa for Al2O3. Scanning electron microscopy and X-ray diffraction showed a well-bonded interface between the Al2O3 and Nb without measurable formation of an interfacial reaction phase. The interfacial shear strength between Al2O3 and Nb, measured by a double-notched specimen test, was 290 ± 15 MPa. The feasibility of fabricating prototype femoral heads (32 mm in diameter), consisting of an Al2O3 surface layer (2–3 mm thick) and a Nb core, by hot pressing was shown. The composite femoral head combined the low wear of an Al2O3 articulating surface with the safety of a ductile metal femoral head.
Background: The aim of our investigations was the development of a finite element model of the hip joint under consideration of the hip centralizing forces of the iliotibial tract within different femoral neck angles and its influence to the centralizing of the femoral head to the acetabulum.Methods: For the development of the finite element model of the femur and the iliotibial tract we utilized the program IDEAS 3D as well as the material/lengthening characteristics of the iliotibial tract. In the following step we developed a hip joint model with different centrum-collum-diaphysis-angles of 115 degrees, 128 degrees and 155 degrees for determination of the IT force and the consequential force on the femoral head.Findings: With a coxa vara the force on the femoral head in relation to the physiological centrum-collum-diaphysis-angle and the coxa valga decreased (115 degrees = 1601 N, 128 degrees = 2360 N, and 155 degrees = 2422 N). On the other side the hip centralizing forces of the iliotibial tract within a coxa vara increased in comparison to 128 (physiological) and 155 degrees (valga) (115 degrees = 997 N, 128 degrees = 655,5 N, and 155 degrees = 438 N). Within a coxa valga a higher compressive force on the femoral head and with a coxa vara a decreasing compressive force on the femoral head occurred.Interpretation: The clinical relevance consists in the predictability of an increasing or decreasing band wiring effect of the iliotibial tract in reliance to the centrum-collum-diaphysis-angle of the femoral neck and its importance for the displacement osteotomy of the growing hip. (C) 2010 Elsevier Ltd. All rights reserved.
Animals are becoming more and more common as in vivo models for the human spine. Especially the sheep cervical spine is stated to be of good comparability and usefulness in the evaluation of in vivo radiological, biomechanical and histological behaviour of new bone replacement materials, implants and cages for cervical spine interbody fusion. In preceding biomechanical in vitro examinations human cervical spine specimens were tested after fusion with either a cubical stand-alone interbody fusion cage manufactured from a new porous TiO2/glass composite (Ecopore) or polymethylmethacrylate (PMMA) after discectomy. Following our first experience with the use of the new material and its influence on the primary stability after in vitro application we carried out fusions of 20 sheep cervical spines levels with either PMMA or an Ecopore-cage, and performed radiological examinations during the following 2-4 months. In this second part of the study we intended the biomechanical evaluation of the spine segments with reference to the previously determined morphological findings, like subsidence of the implants, significant increase of the kyphosis angle and degree of the bony fusion along with the interpretation of the results. 20 sheep cervical spines segments with either PMMA- or Ecopore-fusion in the levels C2/3 and C4/5 were tested, in comparison to 10 native corresponding sheep cervical spine segments. Non-destructive biomechanical testing was performed, including flexion/extension, lateral bending and axial rotation using a spine testing apparatus. Three-dimensional range of motion (ROM) was evaluated using an ultrasound measurement system. In the native spine segments C2/3 and C4/5 the ROM increased in cranio-caudal direction particulary in flexion/extension, less pronounced in lateral flexion and axial rotation (p < 0.05). The overall ROM of both tested segments was greatest in lateral flexion, reduced to 52% in flexion/extension and to 16% in axial rotation. After 2 months C2/3- and C4/5-segments with PMMA-fusion and C2/3-segments with Ecopore-interposition showed decrease of ROM in lateral flexion in comparison to the native segments, indicating increasing stiffening. However, after 4 months all operated segments, independent from level or implanted material, were stiffer than the comparable native segments. The decrease of the ROM correlated with the radiological-morphological degree of fusion. Our evaluation of the new porous TiO2/glass composite as interbody fusion cage has shown satisfactory radiological results as well as distinct biomechanical stability and fusion of the segments after 4 months in comparison to PMMA. After histological analysis of the bone-biomaterial-interface, further examinations of this biomaterial previous to an application as alternative to other customary cages in humans are necessary.
Animals are becoming more and more common as in vivo models for the human spine. Especially the sheep cervical spine is stated to be of good comparability and usefulness in the evaluation of in vivo radiological, biomechanical and histological behaviour of new bone replacement materials, implants and cages for cervical spine interbody fusion. In preceding biomechanical in vitro examinations human cervical spine specimens were tested after fusion with either a cubical stand-alone interbody fusion cage manufactured from a new porous TiO2/glass composite (Ecopore) or polymethylmethacrylate (PMMA) after discectomy. Following our first experience with the use of the new material and its influence on the primary stability after in vitro application we carried out fusions of 20 sheep cervical spines levels with either PMMA or an Ecopore-cage, and performed radiological examinations during the following 2-4 months. In this second part of the study we intended the biomechanical evaluation of the spine segments with reference to the previously determined morphological findings, like subsidence of the implants, significant increase of the kyphosis angle and degree of the bony fusion along with the interpretation of the results.20 sheep cervical spines segments with either PMMA or Ecoporefusion in the levels C2/3 and C4/5 were tested, in comparison to 10 native corresponding sheep cervical spine segments. Non-destructive biomechanical testing was performed, including flexion/extension, lateral bending and axial rotation using a spine testing apparatus. Three-dimensional range of motion (ROM) was evaluated using an ultrasound measurement system.In the native spine segments C2/3 and C4/5 the ROM increased in cranio-caudal direction particulary in flexion/extension, less pronounced in lateral flexion and axial rotation (p < 0,05). The overall ROM of both tested segments was greatest in lateral flexion, reduced to 52% in flexion/extension and to 16% in axial rotation. After 2 months C2/3- and C4/5-segments with PMMA-fusion and C2/3-segments with Ecopore-interposition showed decrease of ROM in lateral flexion in comparison to the native segments, indicating increasing stiffening. However, after 4 months all operated segments, independent from level or implanted material, were stiffer than the comparable native segments. The decrease of the ROM correlated with the radiological-morphological degree of fusion.Our evaluation of the new porous TiO2/glass composite as interbody fusion cage has shown satisfactory radiological results as well as distinct biomechanical stability and fusion of the segments after 4 months in comparison to PMMA. After histological analysis of the bone-biomaterial-interface, further examinations of this biomaterial previous to an application as alternative to other customary cages in humans are necessary.
Divergent descriptions of the anatomic location and biomechanical function of the iliotibial tract (IT) can be found in the literature. This study attempted to obtain exact data regarding the anatomic course and material characteristics including the biomechanical properties of this structure. The following were its aims: (1) anatomical investigations of the IT; (2) mechanical properties of the IT; (3) femoral head centralizing force of the IT and subligamentous forces in the height of the greater trochanter in different joint positions by using a custom-made measuring prosthesis and a subligamentous positioned sensor; (4) construction of a finite element model of the proximal femur including the IT and measuring the femoral neck angle under variation. The hip joints and IT in a total of 18 unfixed corpses were evaluated. We studied the anatomic relationship to surrounding structures, as well as the material properties with the help of tensile strength testing utilizing an uniaxial apparatus. During the test, a load-displacement curve was registered, documenting the maximum load and deformation of the IT. To measure the subligamentous pressure at the height of the greater trochanter, a custom-made sensor with a power-recording instrument was constructed. Furthermore, an altered hip prosthesis with a pressure gauge at the height of the femoral neck was used to measure the forces which are directed at the acetabulum. The investigations were done in neutral-0 position and ab/adduction of the hip joint of the unfixed corpse. In addition, we varied the femoral neck angle between 115° and 155° in 5° steps. To confirm the subligamentous forces, we did the same measurements intraoperatively at the height of the greater trochanter before and after hip joint replacement in 12 patients. We constructed a finite element model of the proximal femur and considering the IT. The acquisition of the data was done at physiological (128°), varus (115°), and valgus (155°) femoral neck angles. The influencing forces of the IT at the height of the greater trochanter and the forces at the femoral head or the acetabulum could be measured. Our anatomical investigations revealed a splitting of the IT into a superficial and a deep portion, which covers the tensor fasciae latae. The tensor fasciae latae has an insertion on the IT. The IT continues down the femur, passing over the greater trochanter without developing an actual fixation to the bone. Part of the insertion of the gluteus maximus radiates into the IT. The IT passes over the vastus lateralis and inserts at the infracondylar tubercle of the tibia or Gerdy’s tubercle, at the head of the fibula, as well as at the lateral intermuscular septum. Portions also insert on the transverse and longitudinal retinaculum of the patella. Concerning the material properties of the IT, we found a structural stiffness of 17 N/mm extension on average (D=17 N/mm). The subligamentous measurements at the height of the greater trochanter in the unfixed corpse and intraoperatively during hip joint replacement showed an increase of the forces during adduction and a decrease during abduction of the hip joint. We found thereby a maximum increase up to 106 N with 40° adduction. Concerning the femoral neck angle, we can state that valgus leads to lower subligamentous forces and varus to higher subligamentous forces. The forces directed at the acetabulum, which were measured by the prosthesis with a sensor along the femoral neck, showed a decrease with varus angles and an increase with valgus angles. The highest force of 624 N was measured with 40° adduction and an angle of 155°. The finite element model of the proximal femur showed a sole hip joint-centralizing force of the IT of 655 N with a femoral neck angle of 128° after subtraction of the gluteal muscle force and the body weight. At 115°, we found an increase up to 997 N and a decrease to 438 N at 155°. Concerning the resulting forces in the acetabulum, we found opposite forces in comparison with the force of the IT at the height of the greater trochanter: at 115°, a femoral head-centralizing force of 1601 N; at 128°, 2360 N; and at 155°, 2422 N. By our investigations, we can approximately prove the hip joint-centralizing force of the IT. By variation of the femoral neck angle and the position of the hip joint, we can predict the subligamentous force of the IT and the resulting force at the femoral head or at the acetabulum. The intraoperative measurement of the subligamentous forces of the IT is a good monitoring mechanism for the persistent hip-centralizing function of the IT in the course of hip joint replacement. The surgeon has the opportunity to check the stability of the hip joint after replacement. The finite element model gives the opportunity to check the divergent relative strength by variation of the femoral neck angle and the tension of the IT. In this way, the changes in the forces induced by a displacement osteotomy could be estimated preoperatively.