This study presents the design, experimental evaluation, and energy savings potential of an active thermal switch technology for building envelopes, enabling variable thermal resistance. The switch incorporates a low-power motor and a Raspberry Pi-based control for programmable switching, real-time monitoring, and fault detection. The effective thermal conductivity of a switch inserted into a 10 in × 10 in (0.064 m2) insulation is measured to ∼0.046 W/m-K in the OFF state and 0.258–0.316 W/m-K in the ON state. Cyclability tests over 225 thermal cycles show no performance degradation. Outdoor tests using scaled-down models demonstrate improved performance of wall-integrated phase change materials (PCMs). Building energy simulations on single-family residential homes across various US cities’ climates indicate that integrating these switches with PCM-based thermal storage can reduce annual heating and cooling energy use by up to 1,090 kWh and energy costs by up to $286, with average savings of 738 kWh (24%) and $130 (24%), respectively.
This study presents a novel underground thermal energy storage (UTES) system designed for space heating in buildings located in moderate cold climates. The proposed UTES features a borehole with a depth of 25 ft. (7.62 m) and a diameter of 3 ft. (0.91 m), containing two helical pipe loops-one for discharge fluid and another for recharge fluid-and a thermally enhanced phase change material (PCM) layer that provides high energy storage capacity. The system requires daily thermal recharging using a low-grade heat source for a few hours and delivers continuous heating at a nearly constant discharge rate without significant performance degradation over a 24-h period. This study demonstrates that the optimized UTES, when recharged with hot fluid at an inlet temperature of 40 degrees C for 6 h daily, can provide a continuous heat discharge rate of approximately 2.9 kW for 24 h or 3.4 kW if operated under a shorter discharge period of 15 h (17:00-08:00). With a round-trip efficiency of 72-97%, the proposed UTES offers an efficient and reliable solution for short-and long-duration thermal energy storage technology, making it a promising technology for cold climates.
Transit buses serve a vital role in sustainable transportation systems, providing mobility to millions of passengers daily. These buses primarily operate on fixed routes in urban areas, leading to frequent stops at bus stops and traffic signals, which contribute to them having low fuel economy. In recent years, hybrid electric buses and plug-in hybrid electric buses (PHEBs) have gained significant interest in transit applications. However, the energy efficiency of early HEBs and PHEBs is limited as they rely primarily on simple charge sustaining strategies. This paper presents the design, implementation, and validation of a Connected Eco-Bus system that utilizes connected and automated vehicle technology to improve the energy efficiency of a power-split PHEB. The system co-optimizes the PHEB’s vehicle dynamics and powertrain controls by leveraging connectivity and partial automation (Level 1) capability. A case study is conducted with the Connected Eco-Bus system operating on a typical urban route where its performance is evaluated through both microscopic simulation and Dynamometer-in-the-Loop testing. The results demonstrate that the Connected Eco-Bus system can achieve energy efficiency improvements of up to 32.4%, which would thereby contribute to a more sustainable transportation system.
Increasing energy demand and rising peak loads present significant challenges for energy management in commercial and institutional settings. As climate change drives greater cooling needs, central plants must navigate the complex tradeoffs between operational efficiency, cost control, and grid stability. Thermal energy storage (TES) systems offer a viable solution by shifting energy consumption from peak to off-peak periods, thereby reducing peak demand, lowering utility expenses, and improving grid resilience. However, the success of TES implementation hinges on appropriate system sizing, effective control strategies, and alignment with local utility rate structures. This article presents a techno-economic analysis of integrating a chilled water TES system into the central plant at California State University, Dominguez Hills. Drawing on historical load profiles and utility tariffs, we assess three TES sizing approaches and their corresponding control strategies from both energy and economic perspectives. This article utilizes a model-based approach to assess the impact of TES sizing and control strategies on the techno-economic feasibility of integrating TES into an existing central plant. The models employed for this analysis were calibrated using 4 years of historical data. The results demonstrated that utility tariffs and the campus's operational profiles dictate the most feasible sizing and control methods. The findings offer valuable insights for institutions and commercial building managers exploring sustainable energy solutions. By demonstrating how optimized TES strategies can improve operational efficiency while achieving financial savings, this study highlights the potential for TES to align performance with cost effectiveness in real-world applications.
Rising global temperatures and increasing energy demands pose significant challenges for energy management, particularly in institutional and commercial settings. As cooling needs grow, campuses must balance operational efficiency, cost control, and grid stability. Energy storage solutions, such as thermal energy storage (TES) systems, offer a promising approach to shifting energy consumption from peak to off-peak periods, alleviating peak demand, reducing utility costs, and enhancing grid resilience. When integrated with existing battery energy storage systems (BESS), TES can further optimize load management and improve energy savings, especially in buildings with diverse energy needs. This article presents a techno-economic analysis of integrating a chilled water TES system into the central plant at California State University, Dominguez Hills, which already operates a BESS. We assess three TES sizing strategies-full storage, load leveling, and peak demand limiting- by modeling and simulations based on historical energy loads. Our findings show that we can control TES systems to complement BESS operation, with campus-level load leveling providing the greatest cost savings by reducing peak demands. The study also evaluates the long-term economic viability of TES, considering installation costs, energy savings, and payback periods under varying tariffs. This research offers practical guidance for institutions seeking to enhance energy resilience and reduce operational costs through energy storage solutions.
The stop-and-go traffic pattern on urban roads often results in excessive energy consumption because of unnecessary vehicle braking, idling, and accelerations. With the widespread and increased use of automobiles, this traffic pattern creates many negative impacts (e.g., delayed travel time, air pollution, and additional carbon emission) on the sustainability of our cities. Taking advantage of the recent emerging Internet of Things (IoT) and edge computing paradigms, we propose a mobile edge computing framework that integrates the capability of real-time vehicle-to-infrastructure communication and intelligent speed optimization algorithms into a mobile app to optimize individual vehicles' driving speed at signalized intersections. The optimization aims to mitigate the stop-and-go traffic pattern and its undesirable consequences in urban transportation systems. The framework consists of (1) a cyberinfrastructure-enabled dynamic messaging system for retrieving and delivering real-time traffic and signal phase and timing information from IoT-connected signal controllers and sensors, (2) a real-time speed optimization algorithm for generating intelligent speed advisory using vehicle's information (e.g., GPS and driving directions from mobile sensing) and corresponding signal and traffic information, and (3) an ad-hoc mobile computing environment that converts drivers' smartphones into edge devices to host the speed optimization algorithms for enabling intelligent advisory on the vehicle's driving speed within signalized corridors. The paper presents the design and implementation of the proposed framework. We demonstrate the feasibility, usefulness, and energy-saving benefits of our proposed framework and its prototyping mobile app on urban transportation systems through traffic simulation, real-vehicle laboratory experiments, an evaluative survey, and field communication tests. The simulation-based energy evaluation results show that the 100% usage of the mobile app can achieve 24% energy savings in the transportation system.
In recent years, thermal energy storage (TES) has gained attention for its role in enhancing renewable energy solutions and sustainable energy consumption. The usage of strontium chloride hexahydrate (SCH), graphene nanoplatelet (GNP), and cellulose nanofibril (CNF) additives were investigated to enhance the performance of calcium chloride hexahydrate (CCH) based on the melting/solidification behavior for TES applications. In this work, we develop a promising phase-change-material (PCM) formulation by introducing these additives that reduce supercooling, improve the thermal conductivity and stabilizing the energy storage capacity of CCH. Rheological characterizations demonstrated that the addition of 1 wt% of CNF into CCH produced the required improvement in viscosity and boosted solid-like rheological behavior. Structural characterizations show a physical mixing of the materials within the PCM composites. Our observations show that the amphiphilicity of CNF enables the surface attachment to GNP via hydrophobic interactions providing effective dispersion of GNP throughout the PCM composite. The addition of a nucleating agent, SCH decreased the degree of supercooling of similar to 20 g of CCH from >20 degrees C to 3 degrees C at a cooling rate of 5 degrees C/min. Thermal characterization showed the resulting PCM composite has a latent heat of melting of 186 Jg(-1), phase change temperature of 32 degrees C, and stable thermal properties after being subjected to 70 melt-freeze cycles. Adding CNF and GNP to pure CCH increased its thermal conductivity by 76 %. The high thermal conductivity of GNP and its effective dispersion by CNF is responsible for this enhancement. The study highlights the use of biodegradable nanocellulose for the preparation of sustainable PCM composites with improved performance. These PCM composites are scalable, they have potential to increase energy efficiency and revolutionalize the heating/cooling applications in buildings and other TES systems.
Download This Paper Open PDF in Browser Add Paper to My Library Share: Permalink Using these links will ensure access to this page indefinitely Copy URL Copy DOI
Recent advances in Connected and Automated Vehicle (CAV) technologies have opened up new opportunities to enable safe, efficient, and sustainable transportation systems. However, developing reliable and rapid speed control algorithms in highly dynamic environments with complex inter‐vehicle interactions and nonlinear vehicle dynamics is still a daunting task. In this paper, we develop a novel speed control method for CAVs to produce optimal speed profiles that minimize the fuel consumption and avoid idling at signalized intersections. To this end, an optimal control problem is formulated using the information of the upcoming traffic signal to adapt vehicles' speeds to avoid frequent stop‐and‐go driving patterns. By applying the pseudospectral discretization method and the sequential convex programming method, the computational efficiency is greatly improved, enabling potential real‐time on‐vehicle applications. In addition, the algorithm is implemented under a model predictive control framework to ensure online control with instant response for collision avoidance and robust vehicle coordination. The proposed algorithm is verified through numerical simulations of three different traffic scenarios. The convergence and accuracy of the proposed approach are demonstrated by comparing with a popular nonlinear solver. Furthermore, the benefit of the proposed method in both traffic mobility and fuel efficiency is validated using the speed profile determined from a traffic following model in a simulation software as the baseline.
The worldwide increasing energy demand and 2050 net zero carbon target urge the globe to solve the energy challenge. Thermal Energy Storage (TES) has received significant attention in recent years as TES can be integrated into heating, ventilation, and air-conditioning systems where the energy would be stored during low-demand times and dispatched during high-demand times, resulting in controlling the peak load and improving energy savings. Material development is an integral part of TES. Salt hydrates are appealing due to cost-effectiveness, low- to no toxicity, and their high melting enthalpy, where energy is stored as latent heat. However, most salt hydrates are prone to incongruent melting (i.e., phase separation upon melting), which results in poor stability and large supercooling. In this study, we produced a highly stable novel energy storage material at a composition of 32 wt% sodium sulfate decahydrate, 52 wt% sodium phosphate dibasic dodecahydrate, 12 wt% milled expanded graphite, and 4 wt% borax. The material has a melting temperature of 28°C and an energy storage capacity of 167 kJ/kg with a supercooling of less than 3°C. The system showed no loss in energy storage performance after 150 cycles. The findings suggest that the novel energy storage material developed in this might be utilized in building heating and cooling applications.
A heat pump (HP) moves heat from a low-temperature source to a high-temperature sink with an input of energy. Often, one temperature body fluctuates with time (e.g., diurnal ambient temperature), causing the HP efficiency to vary. Integrating thermal energy storage (TES) into a HP system adds a third temperature body, enabling the HP to be advantageously coupled to any two: the application, the ambient, or the TES at strategic times. Although TES integration with HPs is an important emerging technology to lower energy consumption and decrease energy demand during critical times, the favorable circumstances for TES integration are poorly understood. This paper establishes the energy reduction and demand reduction potential of TES-integrated HPs with both analytical and numerical HP models. All possible temperature arrangements are considered for HP-TES systems with two fixed temperature bodies (application and TES) and one variable temperature (ambient). Results show that overall energy savings are most attainable when the TES temperature is near the application temperature, whereas a large temperature difference between the TES and the application leads to the most peak demand reduction. The potential for overall energy savings increases as the magnitude of ambient temperature fluctuations increases.
The Grid Independent High Efficiency System (GIHES) delivers a heating system that operates free from the power grid and provides ultra-low emissions and high efficiency heating for residential and commercial buildings. The project demonstrated two weeks of continuous grid independent operation of a storage water heater equipped with a powered damper. The Thermoelectric Generator (TEG) integrated GIHES technology revolutionizes heating systems to provide grid resilient hot water production, while delivering significant value to the end user by eliminating impacts of power interruption and enhancing comfort, convenience and productivity. The system maximizes the thermal-to-electric conversion efficiency by optimizing location and orientation of the TEGs and durability while lowering system costs. The TEGs generate enough power to charge a battery and run the storage water heater unit with a powered damper uninterrupted by providing the required parasitic electrical power for start-up, shutdown and during idling. Several TEGs were analytically and experimentally evaluated based on the size, surface area and the power being generated before designing and fabricating a complete multi-TEG assembly for integration with the water heater. The GIHES technology can be extended to boilers, furnaces and tankless water heaters and integrated with heat pump to further increase the overall equipment efficiency. The technology has the potential to reduce the amount of dispatch power and peak power plant operation. An advanced burner was designed, developed and 3D printed for fuel flexible operation. The burner was designed to enable tighter integration with TEGs for potentially higher TEG output, should this be necessary. A bench-scale test rig to perform testing of a 200,000 Btu/h burner and capable of handling up to 10% H2 (by volume) was setup at GTI’s laboratory with appropriate safety and controls to ensure smooth and safe operation. Testing of the 3D burner showed < 5 ppm NOx emissions can be achieved for the entire firing range and with different levels of hydrogen blends with natural gas. The burner will enable a more integrated TEG-burner module design for improved system performance, should this be required in the future. Techno-economic analysis (TEA) of the TEG integrated with the water heaters was performed. The testing data and the power output were used to develop the TEA. The analysis for the storage unit with damper showed that the TEG integrated system costs $95. This is much lower than a one-time charge needed to wire and install dedicated power. Discussions with TEG manufacturers and OEM’s will provide more detailed information and methods to further lower these costs.
To mitigate the variation in demand on the electric grid, thermal energy storage (TES) is an alternative to electric batteries or installing new peaking power plants. Stakeholders and policy makers across the United States have expressed interests in promoting TES, as demonstrated by the US Department of Energy’s Grid-Interactive Efficient Buildings program and the efforts of various state legislatures. However, the cost value provided by TES are unclear. If reliable cost benefits were determined, stakeholders would have a clearer picture of the financial returns that can be gained from their investment in TES. The study in this report is conducted by ORNL with collaboration with Emerson the Helix Innovation Center. In the first part of this report, EnergyPlus was used to perform whole-building simulations for two residential buildings in Indianapolis and Atlanta. The HVAC system in both buildings were equipped with phase change material TES. The TES tank was charged in off-peak hours and discharged in peak hours to perform load shifting. First, the economic value implied by existing time-of-use (TOU) rates offered by utility companies was analyzed via whole-building simulation. Second, existing demand reduction (DR) incentives sourced from 3 different electrical grid administrators (i.e., California, Texas, and New England region) were surveyed to determine their implied value. The study suggests that the traditional value analysis that focuses on ROI for the building owner significantly undervalues TES technology making economic viability difficult. A more comprehensive value analysis that includes peak demand management and deferred capital for peaking power plants shows that TES should be economically viable but here the value is greater for the utility and requires large market penetration and aggregation to fully realize the benefits. Therefore, to facilitate commercialization, new business models are needed that include a broader range of stakeholders and distribute the value of TES proportionally. In the 2nd part of this project, the benefits of a novel phase change material (PCM) integrated heat pump configuration were evaluated via detailed component based simulation. A one-dimensional PCM heat exchanger model which discretizes the PCM tank and refrigerant tubes into small control volumes is developed. Each control volume can have different PCM temperatures, PCM properties, and heat transfer coefficients. The PCM tank is charged by a wrapped tank condenser and discharged by an internal refrigerant coil. The PCM heat exchanger model is integrated into DOE/ORNL Heat Pump Design Model for heat pump system simulation. To demonstrate the performance of the PCM integrated heat pump, a case study in Chicago was performed. A Time-of-Use utility structure-based control strategy is implemented to schedule the PCM tank charging and discharging mode switching. Compared with a conventional electric heat pump, the PCM integrated heat pump shows superior performance on load shifting and utility cost reduction. As a result, the proposed system demonstrates 24.6% utility saving for cooling application and 25.8% utility saving for heating application.
Phase change material (PCM)-based thermal energy storage (TES) can provide energy and cost savings and peak demand reduction benefits for grid-interactive residential buildings. Researchers established that these benefits vary greatly depending on the PCM phase change temperature (PCT), total TES storage capacity, system configuration and location and climate of the building. In this study, preliminary techno-economic performance is reported for a novel heat pump (HP)-integrated TES system using an idealized approach. A simplified HP-TES was modeled for 1 year of space heating and cooling loads for a residential building in three different climates in the United States. The vapor compression system of the HP was modified to integrate with TES, and all heat transfer to and from the TES was mediated by the HP. A single PCM was used for heating and cooling, and the PCT and TES capacity were varied to observe their effects on the building’s energy consumption, peak load shifting and cost savings. The maximum reduction in electric consumption, utility cost and peak electric demand were achieved at a PCT of 30 °C for New York City and 20 °C for Houston and Birmingham. Peak energy consumption in Houston, New York City, and Birmingham was reduced by 47%, 53%, and 70%, respectively, by shifting peak load using a time-of-use utility schedule. TES with 170 MJ storage capacity allowed for maximum demand shift from on-peak to off-peak hours, with diminishing returns once the TES capacity equaled the daily building thermal loads experienced during the most extreme ambient conditions.
Sodium sulfate decahydrate (Na2SO4.10H2O, SSD), a low-cost phase change material (PCM), can store thermal energy. However, phase separation and unstable energy storage capacity (ESC) limit its use. To address these concerns, eight polymer additives-sodium polyacrylate (SPA), carboxymethyl cellulose (CMC), Fumed silica (SiO2), potassium polyacrylate (PPA), cellulose nanofiber (CNF), hydroxyethyl cellulose (HEC), dextran sulfate sodium (DSS), and poly(sodium 4-styrenesulfonate) (PSS)-were used to explore several stabilization mechanisms. The ESC of PCMs deteriorated when thickeners, SPA, PPA, and CNF, were added. DSS-modified PCMs exhibited greater stability up to 150 cycles. Rheology measurements indicated that DSS did not impact SSD viscosity significantly during stabilization. Dynamic light scattering showed that DSS reduces SSD particle size and electrostatically suspends salt particles in a stable homogeneous solution, avoiding phase separation. This study proposes a promising method to improve the thermal stability of salt hydrate PCMs by utilizing polyelectrolyte-salt hydrate mixture for thermal energy storage applications.
The advent of connected vehicle (CV) technology offers new possibilities for a revolution in future transportation systems. With the availability of real-time traffic data from CVs, it is possible to more effectively optimize traffic signals to reduce congestion, increase fuel efficiency, and enhance road safety. The success of CV-based signal control depends on an accurate and computationally efficient model that accounts for the stochastic and nonlinear nature of the traffic flow. Without the necessity of prior knowledge of the traffic system's model architecture, reinforcement learning (RL) is a promising tool to acquire the control policy through observing the transition of the traffic states. In this paper, we propose a novel data-driven traffic signal control method that leverages the latest in deep learning and reinforcement learning techniques. By incorporating a compressed representation of the traffic states, the proposed method overcomes the limitations of the existing methods in defining the action space to include more practical and flexible signal phases. The simulation results demonstrate the convergence and robust performance of the proposed method against several existing benchmark methods in terms of average vehicle speeds, queue length, wait time, and traffic density.
Natural gas furnaces are the most common space heating equipment in the U.S. residential and commercial building markets. However, current residential natural gas condensing furnaces generate substantial acidic condensate as well as significant emissions of sulfur oxides (SOx), nitrogen oxides (NOx), carbon monoxide (CO), hydrocarbons (HC), and methane (CH4) contributing to environmental degradation of air, water, and soil. This report describes a novel solution to reduce the environmental impact of natural gas condensing furnaces based on the technology of a monolithic acidic gas reduction (AGR) catalyst for SOx trapping, NOx redox to nitrogen, and oxidation of formic acid, CO, HC, and CH4. The AGR technology offers the following benefits: (1) a neutral furnace condensate with a pH of ~7, allowing its safe release into the sewer system thus eliminating a second drainage system; (2) trapping and removing nearly all SOx emissions; (3) NOx emissions nearly at nearly 1-2 ng/J, more than 95% lower than new emissions standards in California; (4) the use of a low-cost heat exchanger as a condensing heat exchanger (HX) since the condensate is not acidic, avoiding the need for expensive stainless steel alloys; and (5) unburnt fuel energy recovery to boost efficiency.The AGR component and AGR-enabled furnace performance were broadly tested to determine their effects on long-term reliability and durability, as well as SOx storage and regeneration activity. The AGR regeneration does not impair the performance in achieving neutral condensate and ultra-low NOx emissions, and the AGR catalyst subjected to regeneration activities continued to function well and achieved slightly better annual fuel utilization efficiency (AFUE). The 400-hour reliability and durability test of the retrofitted condensing furnace with the AGR component shows that the furnace unit still achieves a neutral furnace condensate with a pH of ~7 and enables 0~3 ng/J of NOx emissions. However, the 400-hour operation slightly degraded the AFUE because of soot particle accumulation caused by frequent incomplete combustion owing to inappropriate condensate drainage during testing. Thus, proper condensate drainage is critical for AGR-enabled furnaces. Furthermore, neutron computed tomography was employed to survey the aged AGR component and demonstrate high-resolution 2D and 3D representations for the nondestructive diagnosis of the AGR component. The tomography showed that the AGR component did not deform or suffer broken AGR channels. A new AGR catalyst with low precious metal loading was preliminarily explored to identify a pathway of optimizing AGR material loading and maximizing acidic gas reduction at low cost. The new AGR component can reduce precious metal loading by 38% and still achieve neutral condensate and ultralow NOx emissions. The furnace with the AGR component of low Pt/Rh loading enables a maximum AFUE of 97%, which is meaningfully higher than the original furnace. Long-duration testing for the furnace enabled with the low precious metal loading AGR component will be vital in future research. Although the current work demonstrates a proof of concept for the AGR-enabled furnace, the AGR assembly needs to be optimized and integrated into the design of new OEM furnace products. Furthermore, the AGR technology can be applied not only for residential gas furnaces, but also for commercial rooftop units, gas heat pumps, gas-fired water heaters, combustion boilers, and other systems.
Increased energy consumption from autonomous vehicle (AV) sensors and computational load as well as upfront costs of sensors are barriers to broad AV adoption. For high quality and reliable perception of the driving environment, incoming data from multiple sensors need to be fused together using advanced computational algorithms, which requires a high compute load. As an alternative, infrastructure-based sensors can be designed to facilitate perception and sensing by supporting vehicle-to-infrastructure (V2I) information exchange. This work presents the initial development and evaluation of a novel energy efficient infrastructure-based sensor. The sensor, a chip-enabled raised pavement marker (CERPM), is capable of wireless communications to exchange environment information with AVs. As a test case, the developed CERPM is applied in real-world driving to perform lane line and drivable region detection for an AV. It is shown that CERPMs can be utilized to effectively detect the lane line and drivable region, which can improve perception while reducing the compute load.
Heating and cooling systems in building infrastructure utilize conventional materials that account for a considerable amount of energy usage and waste. Phase change material (PCM) is considered a promising candidate for thermal energy storage that can improve energy efficiency in building systems. Here, a novel salt hydrate-based PCM composite with high energy storage capacity, relatively higher thermal conductivity, and excellent thermal cycling stability was designed and developed. The thermal cycling stability of the PCM composite was enhanced by using dextran sulfate sodium (DSS) salt as a polyelectrolyte additive, which significantly reduced the phase segregation of salt hydrate. The energy storage capacity and the thermal conductivity of the composite were enhanced by the addition of various graphitic materials along with Borax nucleator. A significant increase in thermal cycling stability was observed for the DSS-modified composite, with over 100 thermal cycles without degradation. The final PCM composite exhibited as much as 290% increase in energy storage capacity relative to the pure salt hydrate, and approximately 20% increase in thermal conductivity. In addition, the PCM composite developed can be produced at larger scale, and can potentially change the future of heating/cooling system in building infrastructure.