OBJECTIVE:To compare changes in foraminal motion at two time points post-surgery between artificial disc replacement (ADR) and anterior cervical discectomy and fusion (ACDF). METHODS:Eight ACDF and 6 ADR patients (all single-level C5-6) were tested at 2 years (T1) and 6.5 years (T2) post-surgery. The minimum foraminal height (FH.Min) and width (FW.Min) achieved during neck axial rotation and extension, and the range of these dimensions during motion (FH.Rn and FW.Rn, respectively) were measured using a biplane dynamic x-ray system, CT imaging and model-based tracking while patients performed neck axial rotation and extension tasks. Two-way mixed ANOVA was employed for analysis. RESULTS:In neck extension, significant interactions were found between year post-surgery and type of surgery for FW.Rn at C5-6 (p<0.006) and C6-7 (p<0.005), and for FH.Rn at C6-7 (p<0.01). Post-hoc analysis indicated decreases over time in FW.Rn for ACDF (p<0.01) and increases in FH.Rn for ADR (p<0.03) at the C6-7 adjacent level. At index level, FW.Rn was comparable between ACDF and ADR at T1, but was smaller for ACDF than for ADR at T2 (p<0.002). In axial rotation, differences were found between T1 and T2 but did not depend on type of surgery (p>0.7). CONCLUSIONS:Changes were observed in the range of foraminal geometry at adjacent levels from 2 years to 6.5 years post-surgery that were different between ACDF and ADR for neck extension. These changes are contrary to the notion that motion at adjacent levels continue to increase following ACDF as compared to ADR over the long term.
Background Post-surgical changes in adjacent segment motion are considered a factor in further development of degeneration and cervical radiculopathy. The objective was to examine the extent of correlations between physiological motion of cervical foramina and long-term patient reported outcomes (PRO). Methods Biplane X-ray imaging and CT-based markerless tracking were used to measure 3D static and dynamic dimensions during neck axial rotation and extension from 18 patients treated for C5-6 radiculopathy with fusion or arthroplasty. Minimum foraminal height (FH.Min) and width (FW.Min), and their range (FH.Range and FW.Range) achieved during a motion task were calculated for adjacent levels (C4-5 and C6-7) at 2.0±0.6 years post-surgery. The modified Japanese Orthopedic Association score (mJOAS), the Neck Disability Index (NDI) including the visual analogue scale (VAS) for neck and arm pain, and the EuroQol EQ-5D score were recorded at 6.5±1.1 years post-surgery. The relationships between 6.5-year outcomes and 2-year foraminal motion were examined using regression. Results Worsening patient-reported outcomes were generally associated with lower values of FW.Min (P<0.05 to P<0.008), the associations being stronger for neck extension (r2 up to 0.43). Dynamic foraminal measurements from the C6-7 level more significantly and consistently correlated with mJOAS, EQ-5D and NDI Arm Pain VAS (r2=0.27 to 0.43; P<0.03 to P<0.008), whereas those from the C4-5 level correlated with NDI Neck Pain VAS (r2=0.33; P<0.02). Conclusions Dynamic 3D foraminal dimensions at 2-year post-surgery, notably FW.Min measured in neck extension at adjacent levels, were associated with PRO at 6.5 years post-surgery. These relationships provide insight into the motion related factors in development of pain and loss of function, and may help develop markers or objective outcome measures.
Purpose: Anterior cruciate ligament (ACL) ruptures are common and are frequently reconstructed using a patellar tendon (PT) autograft. Unfortunately, the time course of PT healing after ACL reconstruction is not particularly well understood. Thus, the primary objective of this study was to use shear wave elastography (SWE) to evaluate the extent to which shear wave speed (SWS) is associated with time after ACL reconstruction. Methods: Longitudinal SWE images were acquired from lateral, central, and medial regions of the PT from two groups: 30 patients who had undergone ACL reconstruction with a PT autograft within the preceding 40 months, and 30 age-matched asymptomatic control subjects. SWE images were acquired at 20 degrees and 90 degrees of passive flexion from both knees. In each subject group, statistical analyses assessed changes in mean SWS with time post-surgery, as well as differences in mean SWS between PT regions and limbs. Results: In the ACL reconstruction patients, mean SWS increased with time post-surgery in the lateral region of the involved knee (p = 0.025) and decreased with time post-surgery in the central region of the contralateral knee (p = 0.022). Conclusion: The findings suggest that there is an association between the mechanical properties of the PT and time post-surgery in both the involved and contralateral limbs after ACL reconstruction. These changes are likely due to maturation of the donor site tissue and changes in gait/loading patterns following ACL rupture and reconstruction. (C) 2018 Elsevier B.V. All rights reserved.
BACKGROUND: Changes in the dimensions of the cervical neural foramina (CNF) are considered to be a key factor in nerve root compression and development of cervical radiculopathy. However, to what extent foraminal geometry differs between patients who underwent anterior cervical discectomy and fusion (ACDF) and those who underwent total disc arthroplasty with an artificial disc (AD) during physiological motion is largely unknown. PURPOSE: The objective of this study is to compare CNF dimensions during physiological neck motion between ACDF and AD. STUDY DESIGN/SETTING: This is a retrospective comparative analysis of prospectively collected, consecutive, non-randomized series of patients at a single institution. PATIENT SAMPLE: A total of 16 single-level C5-C6 ACDF (4 males, 12 females; 28-71 years) and 7 single-level C5-C6 cervical arthroplasty patients (3 males, 4 females; 38-57 years), at least 12 months after surgery (23.6 +/- 6.8 months) were included. OUTCOME MEASURES: Patient demographics, preoperative magnetic resonance imaging (MRI)-based measurements of cervical spine degeneration, and 2-year postoperative measurements of dynamic foraminal geometry were the outcome measures. METHODS: Biplane X-ray images were acquired during axial neck rotation and neck extension. A computed tomography scan was also acquired from C3 to the first thoracic vertebrae. The subaxial cervical vertebrae (C3-C7) were reconstructed into three-dimensional (3D) bone models for use with model-based tracking. Foraminal height (FH) was calculated as the 3D distance between the superior point of the inferior pedicle and the inferior point of the superior pedicle using custom software. Foraminal width (FW) was similarly calculated as the 3D distance between the anterolateral aspect of the superior vertebral body inferior notch and the posterolateral aspect of the inferior vertebral body superior notch. Dynamic foraminal dimensions were quantified as the minimum (FH.Min, FW.Min), the range (FH.Range, FW.Range), and the median (FH.Med, FW.Med)of each trial and then averaged over trials. Mixed model analysis of variance framework was used to examine the differences between ACDF and AD groups. The initial severity of disc degeneration as determined from preoperative MRI images was introduced as covariates in the models. RESULTS: At the operated level (C5-C6), FH.Med and FH.Range were smaller in ACDF than in AD during axial rotation and neck extension (p<.003 to p<.05). At the superior adjacent level (C4-C5), no significant difference was found. At the inferior adjacent level (C6-C7), FW.Range was greater in ACDF than in AD during axial rotation and extension (p<.05). At the non-adjacent level (C3-C4), FW.Range was greater in ACDF than in AD during extension (p<.008). CONCLUSIONS: This study demonstrated decreases in foraminal dimensions and their range for ACDF compared with AD at the operated level. In contrast, it demonstrated increases in the range of foraminal dimensions during motion for ACDF compared with AD at the non-operated segments. Together, these data support the notion that increased mobility at the non-operated segments after ACDF may contribute to a greater risk for adjacent segment degeneration. Because of the significant presence of range variables in the findings, the current data also indicate that a dynamic evaluation is likely more appropriate for evaluation of the differences in foramina between ACDF and AD than a static evaluation. (C) 2017 Elsevier Inc. All rights reserved.
Shear wave elastography (SWE) is an emerging technology that provides information about the inherent elasticity of tissues by producing an acoustic radiofrequency force impulse, sometimes called an "acoustic wind," which generates transversely-oriented shear waves that propagate through the surrounding tissue and provide biomechanical information about tissue quality. Although SWE has the potential to revolutionize bone and joint imaging, its clinical application has been hindered by technical and artifactual challenges. Many of the stumbling blocks encountered during musculoskeletal SWE imaging are readily recognizable and can be overcome, but progressive advances in technology and a better understanding of image acquisition are required before SWE can reliably be used in musculoskeletal imaging.
BACKGROUND:Shoulder injuries are common among competitive swimmers, and the progression of shoulder pathology is not well understood. The objective of this study was to assess the extent to which years of competitive swim training were associated with physical properties of the supraspinatus muscle and tendon, shoulder strength, and self-reported assessments of shoulder pain and function. HYPOTHESIS:Increasing years of competition will be associated with declining physical properties of the supraspinatus muscle/tendon and declining self-reported assessments of pain and function. STUDY DESIGN:Descriptive epidemiology study. LEVEL OF EVIDENCE:Level 4. METHODS:After institutional approval, 18 collegiate female swimmers enrolled in the study. For each swimmer, supraspinatus tendon thickness was measured; tendinosis was assessed using ultrasound imaging, supraspinatus muscle shear wave velocity was assessed using shear wave elastography, isometric shoulder strength was measured using a Biodex system, and self-reported assessments of pain/function were assessed using the Western Ontario Rotator Cuff (WORC) score. All subjects were tested before the start of the collegiate swim season. Linear regression was used to assess the association between years of competition and the outcome measures. RESULTS:Years of participation was positively associated with tendon thickness ( P = 0.01) and negatively associated with shear wave velocity ( P = 0.04) and WORC score ( P < 0.01). Shoulder strength was not associated with years of participation ( P > 0.39). CONCLUSION:Long-term competitive swim training is associated with declining measures of supraspinatus muscle/tendon properties and self-reported measures of pain and function. Although specific injury mechanisms are still not fully understood, these findings lend additional insight into the development of rotator cuff pathology in swimmers. CLINICAL RELEVANCE:Lengthy swimming careers may lead to a chronic condition of reduced mechanical properties in the supraspinatus muscle and tendon, thereby increasing the likelihood of rotator cuff pathology.
ABSTRACTRotator cuff tears are common and often repaired surgically, but post‐operative repair tissue healing, and shoulder function can be unpredictable. Tear chronicity is believed to influence clinical outcomes, but conventional clinical approaches for assessing tear chronicity are subjective. Shear wave elastography (SWE) is a promising technique for assessing soft tissue via estimates of shear wave speed (SWS), but this technique has not been used extensively on the rotator cuff. Specifically, the effects of age and pathology on rotator cuff SWS are not well known. The objectives of this study were to assess the association between SWS and age in healthy, asymptomatic subjects, and to compare measures of SWS between patients with a rotator cuff tear and healthy, asymptomatic subjects. SWE images of the supraspinatus muscle and intramuscular tendon were acquired from 19 asymptomatic subjects and 11 patients with a rotator cuff tear. Images were acquired with the supraspinatus under passive and active (i.e., minimal activation) conditions. Mean SWS was positively associated with age in the supraspinatus muscle and tendon under passive and active conditions (p ≤ 0.049). Compared to asymptomatic subjects, patients had a lower mean SWS in their muscle and tendon under active conditions (p ≤ 0.024), but no differences were detected under passive conditions (p ≥ 0.783). These findings identify the influences of age and pathology on SWS in the rotator cuff. These preliminary findings are an important step toward evaluating the clinical utility of SWE for assessing rotator cuff pathology. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:282–288, 2018.
Purpose Neural foraminal dimensions are considered important in nerve root compression and development of cervical radiculopathy, but baseline data regarding their range during normal motion are not available. An in vivo study of cervical foraminal motion was conducted to characterize normal 3D dynamic foraminal dimensions during physiological neck motion and compare between different tasks and intervertebral segments. Methods Biplane X-ray imaging and computed tomography-based markerless tracking were used to measure foraminal height (FH) and width (FW) from five asymptomatic subjects during neck axial rotation and extension. FH and FW were quantified as the minimum (SI.Min and AP.Min), range (SI.Range and AP.Range), and median (SI.Med and AP.Med) of superoinferior (SI) and anteroposterior (AP) dimensions for each trial and as the coefficient of variation of these variables from three trials (SI.Med.CV and AP.Med.CV, SI.Range.CV and AP.Range.CV) at C3-4 through C6-7 levels for each subject. Differences were analyzed using mixed model ANOVA. Results AP.Range and AP.Med.CV were greater (P < 0.0001) while AP.Min and AP.Range.CV were smaller (P < 0.0006 and P < 0.0005) during neck extension than rotation. SI.Range and SI.Med.CV were greater for extension than rotation at C5-6 (P < 0.002 and P < 0.03), whereas SI.Med.CV was greater for rotation than extension at C3-4 (P < 0.03). AP.Range (P < 0.02), AP.Med.CV (P < 0.05), SI.Range (P < 0.0004), and SI.Med.CV (P < 0.02) were different between cervical levels, the latter two being during extension only. Conclusions Patterns of FH and FW during normal motion are different between tasks and cervical levels. These findings are expected to provide a basis for future studies of spinal degeneration and surgical efficacy.
Background: The incidence of asymptomatic rotator cuff tears has been reported to range from 15% to 39%, but the influence of asymptomatic rotator cuff pathology on shoulder function is not well understood. This study assessed the effects of asymptomatic rotator cuff pathology on shoulder kinematics, strength, and patient-reported outcomes.Methods: A clinical ultrasound examination was performed in 46 asymptomatic volunteers (age: 60.3 +/- 7.5 years) with normal shoulder function to document the condition of their rotator cuff. The ultrasound imaging identified the participants as healthy (n = 14) or pathologic (n = 32). Shoulder motion was measured with a biplane x-ray imaging system, strength was assessed with a Biodex (Biodex Medical Systems, Inc., Shirley, NY, USA), and patient-reported outcomes were assessed using the Western Ontario Rotator Cuff Index and visual analog scale pain scores.Results: Compared with healthy volunteers, those with rotator cuff pathology had significantly less abduction (P = .050) and elevation (P = .041) strength, their humerus was positioned more inferiorly on the glenoid (P = .018), and the glenohumeral contact path length was longer (P = .007). No significant differences were detected in the Western Ontario Rotator Cuff Index, visual analog scale, range of motion, or acromiohumeral distance.Conclusions: The differences observed between the healthy volunteers and those with asymptomatic rotator cuff pathology lend insight into the changes in joint mechanics, shoulder strength, and conventional clinical outcomes associated with the early stages of rotator cuff pathology. Furthermore, these findings suggest a plausible mechanical progression of kinematic and strength changes associated with the development of rotator cuff pathology. (C) 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. All rights reserved.
Shear wave elastography (SWE) is a promising tool for estimating musculoskeletal tissue properties, but few studies have rigorously assessed its repeatability and sources of error. The objectives of this study were to assess: (1) the extent to which probe positioning error and human user error influence measurement accuracy, (2) intra-user, inter-user, and day-to-day repeatability, and (3) the extent to which active and passive conditions affect shear wave speed (SWS) repeatability. Probe positioning and human usage errors were assessed by acquiring SWE images from custom ultrasound phantoms. Intra- and inter-user repeatability were assessed by two users acquiring five trials of supraspinatus muscle and tendon SWE images from ten human subjects. To assess day-to-day repeatability, five of the subjects were tested a second time, approximately 24 h later. Imaging of the phantoms indicated high inter-user repeatability, with intraclass correlation coefficient (ICC) values of 0.68–0.85, and RMS errors of no more than 4.1%. SWE imaging of the supraspinatus muscle and tendon had high repeatability, with intra- and inter-user ICC values of greater than 0.87 and 0.73, respectively. Day-to-day repeatability demonstrated ICC values greater than 0.33 for passive muscle, 0.48 for passive tendon, 0.65 for active muscle, and 0.94 for active tendon. This study indicates the technique has good to very good intra- and inter-user repeatability, and day-to-day repeatability is appreciably higher when SWE images are acquired under a low level of muscle activation. The findings from this study establish the feasibility and repeatability of SWE for acquiring data longitudinally in human subjects.
Background: Physical therapy (PT) is often prescribed for patients with rotator cuff tears. The extent to which PT influences strength, range of motion (ROM), and patient-reported outcomes has been studied extensively, but the effect of PT on in vivo joint kinematics is not well understood. Purpose: To assess the influence of symptomatic rotator cuff pathology and the effects of PT on shoulder motion, strength, and patient-reported outcomes. Study Design: Controlled laboratory study. Methods: Twenty-five patients with a symptomatic rotator cuff tear and 25 age-matched asymptomatic control subjects were recruited. Shoulder motion was measured using a biplane radiography imaging system, strength was assessed with a Biodex dynamometer, and patient-reported outcomes were assessed using the Western Ontario Rotator Cuff Index and visual analog scale (VAS) pain scores. Data were acquired from the patients before and after 8 weeks of physical therapy. Data were acquired at 1 time point for the control subjects. Results: Compared with the control subjects, patients with a symptomatic rotator cuff tear had significantly worse pain/function scores (P < .01); less ROM (P < .01); lower abduction (ABD), external rotation (ER), and internal rotation (IR) strength (P < .01); less scapulothoracic posterior tilt (P = .05); and lower glenohumeral joint elevation (P < .01). Physical therapy resulted in improved pain/function scores (P < .01), increased ROM (P < .02), increased scapulothoracic posterior tilt (P = .05), increased glenohumeral joint elevation (P = .01), and decreased acromiohumeral distance (AHD) (P = .02). Conclusion: Compared with age-matched controls, patients had worse pain/function scores, less ROM, and lower ABD, ER, and IR strength. Patients also had less scapulothoracic anteroposterior tilt, less glenohumeral joint elevation, and an altered glenohumeral joint contact path. PT resulted in improved pain/function scores, increased ROM, greater posterior scapulothoracic tilt, increased glenohumeral joint elevation, an increased range of superoinferior joint contact, and a lower mean AHD. Of these differences, PT only returned scapulothoracic tilt to control levels. Clinical Relevance: This study documents the effects of PT on shoulder motion and conventional clinical outcomes. It is expected that understanding how changes in joint motion are associated with conventional clinical outcomes will lead to improved nonoperative interventions for patients with rotator cuff tears.
Measures of scapulothoracic motion are dependent on accurate imaging of the scapula and thorax. Advanced radiographic techniques can provide accurate measures of scapular motion, but the limited 3D imaging volume of these techniques often precludes measurement of thorax motion. To overcome this, a thorax coordinate system was defined based on the position of rib pairs and then compared to a conventional sternum/spine-based thorax coordinate system. Alignment of the rib-based coordinate system was dependent on the rib pairs used, with the rib3:rib4 pairing aligned to within 4.4 ± 2.1 deg of the conventional thorax coordinate system.
http://ajs.sagepub.com/content/43/11/2800 The online version of this article can be found at: DOI: 10.1177/0363546515602249 2015 43: 2800 originally published online September 21, 2015 Am J Sports Med J. Bey Cathryn D. Peltz, Timothy G. Baumer, Veronica Mende, Nicole Ramo, Nima Mehran, Vasilios Moutzouros and Michael Patients With Anterior Instability Effect of Arthroscopic Stabilization on In Vivo Glenohumeral Joint Motion and Clinical Outcomes in
Background: Glenohumeral joint (GHJ) dislocations are common, and the resulting shoulder instability is often treated with arthroscopic stabilization. These procedures result in favorable clinical outcomes, but abnormal GHJ motion may persist, which may place patients at risk for developing osteoarthritis. However, the effects of shoulder instability and arthroscopic stabilization on GHJ motion are not well understood. Hypothesis: GHJ motion is significantly influenced by anterior instability and arthroscopic stabilization, but postsurgical measures of GHJ motion are not different from those of control subjects. Study Design: Controlled laboratory study. Methods: In vivo GHJ motion was measured by applying a computed tomographic model-based tracking technique to biplane radiographic images acquired during an apprehension test in healthy control subjects (n = 11) and anterior instability patients (n = 11). Patients were tested before surgery and at 6 months after surgery. Control subjects were tested once. Shoulder strength, active range of motion (ROM), and the Western Ontario Shoulder Instability (WOSI) index were also measured. Results: Before surgery, the humerus of the instability patients during the apprehension test was located significantly more anteriorly on the glenoid (7.9% of glenoid width; 2.1 mm) compared with that of the controls (P = .03), but arthroscopic stabilization moved this joint contact location posteriorly on the glenoid (4.7% of glenoid width; 1.1 mm; P = .03). After surgery, GHJ excursion during the apprehension test was significantly lower (14.7% of glenoid width; 3.6 mm) compared with presurgical values (19.4% of glenoid width; 4.7 mm; P = .01) and with that of the controls (22.4% of glenoid width; 5.7 mm; P = .01). The external and internal rotation strength of patients was significantly lower than that of the controls before surgery (P < .05), but differences in strength did not persist after surgery (P > .17). External rotation ROM in patients was significantly lower than that in control subjects both before and after arthroscopic stabilization (P < .01). The WOSI score improved significantly, from 48.3 ± 13.1 presurgery to 86.3 ± 16.5 after surgery (P = .0002). Conclusion: In patients with anterior instability, arthroscopic stabilization significantly improves measures of strength, ROM, and clinical outcome. However, GHJ excursion is not fully restored to levels seen in the control subjects. Clinical Relevance: Although arthroscopic stabilization satisfactorily restores most clinical outcome measures, GHJ excursion and external rotation ROM remain compromised compared with healthy control subjects and may contribute to the development of osteoarthritis in patients with anterior instability.
There is significant concern that blast overpressure can cause mild traumatic brain injury (mTBI). An accurate understanding of the blast flow and overpressure event as well as it’s interaction with the head and helmet system is a necessary first step in establishing loading conditions to the head. It also provides a means for model validation and other predictive capabilities. A custom-designed Blast Overpressure Bust (BOB) containing 22 surface pressure sensors was rigidly mounted in a live-fire blast event. The blast field tests were conducted in an open field using 4 lbs. of cylindrical C4 charges suspended 48″ above the pad. The BOB was mounted to a torso surrogate and positioned 92″ from the hanging charge. The BOB was oriented at blast impact angles of 0 (front-facing), 45, 90, and 180 degrees. The BOB was tested in both bare and helmeted configurations. Data recorded across a bare headform at each angle established a baseline for the pressure trace at each sensor location. Two helmeted cases were investigated: Advanced Combat Helmet (ACH) with the sling suspension system and ACH with Team Wendy pads. Results showed peak pressures on exposed surfaces normal to the blast were ∼1200kPa with side-on pressures of ∼400kPa. The addition of a helmet did not alter the peak normal pressures, but showed slight to moderate increases in pressure beneath the helmet based on the amount of cushioning present. The sling suspension, which leaves an open gap between the head and helmet, resulted in several recorded amplification points beneath the helmet with the peaks reaching ∼800kPa. The Team Wendy pads trials, which effectively fill the gap between the head and helmet, showed amplifications with peaks of ∼500kPa. An additional set of tests was conducted using an ingress barrier positioned between the head and helmet at the brim. Results showed pressures under the helmet that were lower than the bare headform trials. While it was shown that adding a helmet did in fact increase pressures relative to the bare headform case, these amplifications were still far less than the peak pressure exerted on the exposed surfaces of the headform. The data presented herein is the most robust data set to date for pressures exerted on a helmeted headform and is considered applicable to the first 3–5ms of an unconstrained system, during which time motion is minimal.
The objective of this study was to document patterns of fracture on infant porcine skulls aged 2-28 days (n = 57) because of a single, high energy blunt impact to the parietal bone with rigid (nondeformable) and compliant (deformable) interfaces. Fracture patterns were mapped using Geographic Information System software. For the same generated impact force, the rigid interface produced more fractures than the compliant interface for all ages. This study also showed that this increased level of impact energy versus an earlier study using a lower energy resulted in new sites of fracture initiation and also caused previously defined fractures that propagate into an adjacent bone. Several unique characteristics of bone and diastatic fracture were documented as a function of specimen age, impact energy, and interface. These data describe some baseline characteristics of skull fracture using an animal model that may help guide future studies from forensic case files.
Knee hyperextension has been described as a mechanism of isolated anterior cruciate ligament (ACL) tears, but clinical and experimental studies have produced contradictory results for the ligament injuries and the injury sequence caused by the hyperextension loading mechanism. The hypothesis of this study was that bicruciate ligament injuries would occur as a result of knee hyperextension by producing high tibio-femoral (TF) compressive forces that would cause anterior translation of the tibia to rupture the ACL, while joint extension would simultaneously induce rupture of the posterior cruciate ligament (PCL). Six human knees were loaded in hyperextension until gross injury, while bending moments and motions were recorded. Pressure sensitive film documented the magnitude and location of TF compressive forces. The peak bending moment at failure was 108 N m±46 N m at a total extension angle of 33.6 deg±11 deg. All joints failed by simultaneous ACL and PCL damages at the time of a sudden drop in the bending moment. High compressive forces were measured in the anterior compartments of the knee and likely produced the anterior tibial subluxation, which contributed to excessive tension in the ACL. The injury to the PCL at the same time may have been due to excessive extension of the joint. These data, and the comparisons with previous experimental studies, may help explain the mechanisms of knee ligament injury during hyperextension. Knowledge of forces and constraints that occur clinically could then help diagnose primary and secondary joint injuries following hyperextension of the human knee.
This study documents skull fracture characteristics on infant porcine specimens under known impact conditions with respect to age and interface. A single impact causing fracture was conducted on the skull of porcine specimens aged 2-28 days (n = 76). Paired rigid and compliant impacts at the same energy were conducted at each specimen age. Impact force, impact duration, and fracture length were recorded. Energy required to initiate skull fracture increased with specimen age. For a given energy, impact of the skull with a compliant interface caused more fracture damage than with a rigid interface for specimens aged under 17 days, but less damage for specimens aged 24-28 days. The documentation of energy required to cause fracture and resulting fracture propagation with respect to impact interface and age may be of critical importance in forensic investigations of infant skull trauma.
There is a 1 in 3 chance of abuse in a case where a child less than 18 months has a skull fracture [1]. The most commonly fractured site on the skull is the parietal bone, however it is currently difficult to establish the causation of injury based on the characteristics of the injury [2]. Thus, injury biomechanics are often utilized in the investigation of suspected child abuse cases [3]. Computer simulations, test dummies, and animal models are all used as aids in the assessment of skull fracture causation. For a given impact situation, a number of variables can control the pattern of skull fracture. A study by Baumer et. al assessed the effects of interface and age using an infant porcine skull model, specifically looking at the location of fracture initiation on the parietal bone [4]. This study showed that in low energy impacts fracture initiation occurs at the bone-suture boundary. Also, a deformable interface caused more fracture than a rigid interface for very young subjects. The current study was conducted to assess the effects of higher energy impacts on the patterns of fracture in this model.