Gamma radiation used for sterilization of medical devices is challenged by cobalt-60 supply and commercial capacity. To maintain a robust radiation sterilization marketplace for the rapidly growing single-use medical device industry, investigation of potential alternatives to gamma technology, such as electron beam (e-beam) and X-ray technology, is critical. In this work, we directly compare the effects of radiation source and absorbed dose level on the polymeric materials and function of a commercial pulsed lavage device used for wound care. Product functionality, polymer mechanical, and polymer optical properties were evaluated using standard methods and input from the device manufacturer. Test results show that functionality of the product was not inhibited by radiation although the battery in the device exposed to X-ray exhibited greater voltage loss compared to batteries in products exposed to gamma or e-beam. Statistically significant differences between gamma and e-beam exposure and between gamma and X-ray exposure were also observed for product appearance in terms of yellowness index of several of the polymers considered. Overall, the results of this study support the viability of e-beam and X-ray radiation technologies as alternatives to cobalt-60 gamma technology for sterilization of the single-use pulsed lavage medical device investigated.
The medical device industry has been investigating ways to increase the use of alternatives to cobalt-60 gamma radiation and ethylene-oxide gas sterilization, such as electron beam (E-beam) and X-ray radiation, due to regulatory and market pressures. One impediment to switching to E-beam or X-ray technology for sterilization is the lack of data on the effects of these radiation sources on medical device polymers. To provide such data this work considers irradiation and testing of a common single-use medical bone cement mixing system, the Stryker Advanced Cement Mixer (ACM (R)), that is composed of seven polymer materials. The ACM (R) devices considered here were processed to sterilization-relevant doses (15, 25, 50, and 70 kGy) using three radiation technologies: gamma, E-beam, and X-ray. The system and its polymer components were tested for product functionality, as well as mechanical and visual properties to determine how exposure effects may be influenced by radiation technology and dose level. We found that although there were instances of statistically significant differences in effects between the gamma-irradiated products and those irradiated with E-beam and X-ray, those effects were negligible in terms of retained functionality of the product and retained mechanical properties of the polymer components. Overall, results of this study demonstrate that, for of the effects studied, E-beam and X-ray are viable alternatives to cobalt-60 gamma radiation for sterilization of the polymer-based device investigated.
Many polymer-based medical devices are sterilized by gamma irradiation. To reduce the use of cobalt-60 gamma-ray sources, transition from gamma ray to alternative irradiation technologies was proposed, namely electron beam (e-beam) and X-ray. A major impediment for such a transition is the knowledge gap in material compatibility with the different radiation sources. In this study, multi-layer films consisting of ethylene vinyl acetate (EVA) and ethylene vinyl alcohol (EVOH) components were irradiated to target doses of 30, 45, and 60 kGy by gamma-ray, e-beam, and X-ray sources. Effects of irradiation were evaluated on 12 material properties, and statistical comparisons between gamma irradiation and alternative technologies were conducted using the two one-sided t-test (or “equivalence test”) and classic t-test. Melting temperature and UV absorbance below 300 nm showed dose dependencies, while other investigated properties such as discoloration and mechanical durability did not change with dose up to 60 kGy. Based on these results, there is no material compatibility issue associated with the transition from gamma to e-beam or to X-ray as source of sterilization radiation of the studied multi-layer film.
Due to market and regulatory pressures, many healthcare manufacturers are considering alternatives to cobalt-60 gamma radiation, including accelerator-based electron beam (E-beam) and X-ray radiation for product sterilization. In this work, the effects of irradiation on a representative medical product, comprised of eight distinct polymer materials, were directly compared for three radiation technologies - cobalt-60 gamma, E-beam, and Xray - at four dose levels (15, 25, 50, and 70 kGy). The objective was to determine how radiation effects (deleterious or beneficial) are influenced by source and dose level, with the specific goal of determining whether E-beam radiation and/or X-ray radiation could be viable alternatives to gamma radiation for device sterilization. The specific product considered is a single-use medical device for orthopedic surgery, the Stryker Instruments MixeVac III bone cement mixer, which is currently sterilized using gamma radiation from cobalt-60 sources. Following ASTM International standards and input from the manufacturer, we characterized the effects of the three radiation sources on product functionality as well as on the mechanical and optical properties of the constituent polymers. Results indicate that although measurable differences in properties between the standard gamma irradiated materials and the alternative E-beam and X-ray irradiated materials were observed, those differences were small. Statistically significant differences were noted in the case of yellowness index for polyvinyl chloride, high-density polyethylene, and polycarbonate, and in the case of tensile elongation at break for high impact polystyrene and polyvinyl chloride. In general, the results of this study support the viability of Ebeam and X-ray radiation as alternative options to cobalt-60 gamma radiation for sterilization of Stryker singleuse universal bone cement mixer medical devices.
Abstract Many polymer-based medical devices are sterilized by gamma irradiation. To reduce the use of cobalt-60 gamma-ray sources, transition from gamma ray to alternative irradiation technologies was proposed, namely electron beam (e-beam) and X-ray. A major impediment for such a transition is the knowledge gap in material compatibility with the different radiation sources. In this study, multi-layer films consisting of ethylene vinyl acetate (EVA) and ethylene vinyl alcohol (EVOH) components were irradiated to target doses of 30, 45, and 60 kGy by gamma-ray, e-beam, and X-ray sources. Effects of irradiation were evaluated on 12 material properties, and statistical comparisons between gamma irradiation and alternative technologies were conducted using the two one-sided t-test (or “equivalence test”) and classic t-test. Melting temperature and UV absorbance below 300 nm showed dose dependencies, while other investigated properties such as discoloration and mechanical durability did not change with dose up to 60 kGy. Based on these results, there is no material compatibility issue associated with the transition from gamma to e-beam or to X-ray as source of sterilization radiation of the studied multi-layer film.
Color change of electric cable insulations used in nuclear power plants (NPPs) is a non-destructive, quick and inexpensive technique to measure degradation. Quantification of color change is facilitated by a light booth of CIE D65 illuminant, a commercial camera and open-source software ImageJ with micaToolbox plugin. Yellowness index (YI) and total color difference (ΔE) are calculated from calibrated photos of a white cross-linked polyethylene (XLPE) and a black ethylene-propylene rubber (EPR) based specimens aged at 110°C, 121°C, 136°C and 150°C after 1~640 days. Using the same setup and software, pixelwise ΔE profile is determined for the cross-sectional photo of a white EPR specimen, where heterogeneous aging is detected.
In nuclear power plants (NPPs), the aging of electrical cable insulation occurs due to elevated temperature, ionizing radiation, and other environmental factors. To ensure the safe and efficient operation of NPPs, determination of key indicators of cable aging is critical to predict the remaining useful lifetime of electrical cable insulation. In this work, the effects of simultaneous and sequential thermal and gamma radiation on the aging of cross-linked polyethylene (XLPE) electrical cable insulation are investigated. The chemical changes of the insulation were monitored non-destructively through the use of Fourier transform infrared (FTIR) spectroscopy. The FTIR spectra were measured stepwise after predetermined exposure intervals, with a total irradiation dose up to 320 kGy at a dose rate of 300 Gy/hr in two exposure scenarios; simultaneously aged samples were heated at 150°C during irradiation, while sequentially aged samples were heated at 150°C for designated durations followed by corresponding times of irradiation at ambient temperature. A data-driven approach using principal component analysis (PCA) was developed to highlight changes in the carbonyl region of the infrared spectra of the aged samples due to oxidation and to differentiate oxidation rates under the simultaneous and sequential exposure conditions. Findings indicate that the sequential aging scenario in which irradiation follows thermal aging may be more conservative than the simultaneous aging scenario for XLPE electrical cable insulation.
Effective sterilization methods for single-use devices are a growing need for the medical industry. Concerns with safety, throughput and source availability, however, prompt prudent contingency planning for gamma irradiation of devices suited for radiation sterilization. Electron beam (e-beam) and X-ray represent two alternatives to gamma radiation if they can be confirmed to be compatible with sterilization of the devices. To address this question, the effects of sterilization-relevant doses of e-beam and X-ray radiation are directly compared to the effects of gamma radiation using two prototypical commercial devices currently sterilized using cobalt-60 gamma radiation. These devices include components that comprise six distinct polymer materials commonly used in the medical device industry. The devices investigated are the Becton, Dickinson and Company (BD) Vacutainer (TM) Plus tube, comprised of low-density polyethylene, chlorobutyl rubber, and polyethylene terephthalate components; and the BD Vacutainer (TM) Push Button Blood Collection Set, containing polypropylene, polyolefin elastomer, and polyvinyl chloride components. Changes in functionality, discoloration and select mechanical properties of components of each device were measured following exposure to targeted doses of 15, 35, 50 and 80 kGy. A statistical analysis was performed to determine if the effects of e-beam or X-ray radiation differ from the effects of gamma radiation for the properties considered. No devices were found to fail the functional performance tests at any of the doses considered. Small, but statistically significant differences were observed in device discoloration from e-beam, X-ray and gamma radiation following processing for certain materials at certain dose levels. Both e-beam and X-ray irradiation appear as viable alternatives to gamma irradiation for sterilization of the medical devices and materials considered.
There is a growing need for increased efficiency in the sterilization of single use medical devices and other products that contain polymer components. Gamma radiation is widely used for devices suited for radiation sterilization; however, safety, throughput and cobalt-60 source availability are challenging the prospect of relying on gamma radiation to meet the anticipated needs of the industry. Use of electron beam (e-beam) and Xrays as alternatives to gamma for radiation sterilization have been hampered in part by a concern that these modalities may adversely affect polymer integrity and performance relative to the gamma method, for which the industry has had much more experience. To address this concern, the effects of sterilization-relevant doses of ebeam, X-ray and gamma radiation were directly compared using common medical device polymers found in two prototypical commercial devices currently sterilized using cobalt-60 gamma irradiation. The Becton, Dickinson and Company (BD) VacutainerTM Plus tube contains low-density polyethylene and chlorobutyl rubber components, while the BD VacutainerTM Push Button Blood Collection Set contains polypropylene homopolymer and polyolefin elastomer components. Injection-molded samples prepared from the polymers used in these products were exposed to target doses of 15, 35, 50 and 80 kGy using gamma, e-beam and X-ray radiation. Changes in coloration, tensile properties and hardness were measured for each condition, and the effects of e-beam and Xray irradiation compared with the effects of gamma irradiation on these properties. Both e-beam and X-ray appear as viable alternatives to gamma irradiation for sterilization of the polymers tested.
Electrical cables constitute a critical component of nuclear power generation. The aging behavior of electrical cable insulation under combined exposure to thermal and radiation stress is not additive, complicating lifetime prediction of cable performance based on sequential accelerated aging. In this work we explore the relative effects of simultaneous and sequential thermal and gamma radiation aging on cross-linked polyethylene (XLPE), which is commonly found in commercial nuclear power plants in the United States. Samples of XLPE were subjected to up to 320 kGy of gamma irradiation at a dose rate of 300 Gy/hr in two heating scenarios. In the first, simultaneously-aged samples were heated at 150°C during irradiation. In the second, sequentially aged samples were heated at 150°C for designated durations followed by corresponding periods of irradiation without heating. The mass, total color difference, and density were characterized to quantify aging of the insulation polymer. Sequential aging is hypothesized to be more damaging to XLPE insulation due to an increased trend in mass gain, total color difference, and density.