PURPOSE:To investigate the diagnostic performance of ultrasound, 2-deoxy-2-[18F]fluoro-D-glucose positron emission tomography/computed tomography (2-[18F]FDG PET/CT) and temporal artery biopsy (TAB) in giant cell arteritis (GCA). METHODS:This was a prospective single-centre diagnostic accuracy study (ClinicalTrials.gov NCT05248906). One hundred and ten patients suspected of GCA were considered, of which 103 were analysed, 100 had a final diagnosis and 58 had complete data for all modalities. Ultrasound, 2-[18F]FDG PET/CT and TAB were performed after clinical examination and blood sampling. The main outcome included diagnostic accuracy measures with final clinical expert diagnosis at 6-month follow-up as the comparator. RESULTS:Sixty-one patients had GCA, 39 had non-GCA and 3 had inconclusive. The sensitivities were 82% (95% CI: 66%-92%), 74% (95% CI: 57%-87%) and 68% (95% CI: 51%-83%) for ultrasound, 2-[18F]FDG PET/CT and TAB, respectively. The corresponding specificities were 90% (95% CI: 68%-99%), 100% (95% CI: 83%-100%) and 100% (95% CI: 83%-100%), the positive predictive values 94% (95% CI: 81%-98%), 100% (95% CI: 88%-100%) and 100% (95% CI: 87%-100%), the negative predictive values 72% (95% CI: 57%-84%), 67% (95% CI: 54%-77%) and 63% (95% CI: 51%-73%) and accuracies 85% (95% CI: 73%-93%), 83% (95% CI: 71%-91%) and 79% (95% CI: 67%-89%). When ultrasound was inconclusive, 2-[18F]FDG PET/CT had a higher sensitivity of 75% (95% CI: 35%-97%) vs. 38% (95% CI: 9%-76%) for TAB, with equal specificity of 100% (both 95% CI: 69%-100%). Results were inconclusive in 22 of 99 ultrasounds, 3 of 102 2-[18F]FDG PET/CTs and 4 of 90 TABs. CONCLUSION:Ultrasound had high diagnostic accuracy for GCA, supporting this as the first imaging modality in suspected GCA. 2-[18F]FDG PET/CT combined a high diagnostic accuracy with fewer inconclusive results, suggesting it may be used for second-line testing when ultrasound is inconclusive, reserving TAB for third-line testing. A fast-track setup may facilitate efficient diagnostics.
Giant cell arteritis (GCA) is an ophthalmological emergency that can be difficult to diagnose and prompt treatment is vital. We investigated the sequential diagnostic value for patients with suspected GCA using three biochemical measures as they arrive to the clinician: first, platelet count, then C-reactive protein (CRP), and lastly, erythrocyte sedimentation rate (ESR). This retrospective cross-sectional study of consecutive patients with suspected GCA investigated platelet count, CRP, and ESR using diagnostic test accuracy statistics and odds ratios (ORs) in a sequential fashion. The diagnosis was established by experts at follow-up, considering clinical findings and tests including temporal artery biopsy. A total of 94 patients were included, of which 37 (40%) were diagnosed with GCA. Compared with those without GCA, patients with GCA had a higher platelet count (p < 0.001), CRP (p < 0.001), and ESR (p < 0.001). Platelet count demonstrated a low sensitivity (38%) and high specificity (88%); CRP, a high sensitivity (86%) and low specificity (56%); routine ESR, a high sensitivity (89%) and low specificity (47%); and age-adjusted ESR, a moderate sensitivity (65%) and moderate specificity (65%). Sequential analysis revealed that ESR did not provide additional value in evaluating risk of GCA. Initial biochemical evaluation can be based on platelet count and CRP, without waiting for ESR, which allows faster initial decision-making in GCA.
The objective of this pilot study was to assess the impact of a salivary gland ultrasound (SGUS) atlas for scoring parenchymal changes in Sjögren’s syndrome by assessing the reliability of the scoring system (0–3), without and with the use of the SGUS atlas. Ten participants with varying experience in SGUS contributed to the reliability exercise. Thirty SGUS images of the submandibular and parotid gland with abnormalities ranging from 0 to 3 were scored using the written definitions of the OMERACT SGUS scoring system and using the SGUS atlas based on the OMERACT scoring system. For intra-reader reliability, two rounds were performed without and with the atlas—in the 2nd round the 30 images were rearranged in random order by a physician not included in the scoring. Inter-reader reliability was also determined in both rounds. Without using the atlas, the SGUS OMERACT scoring system showed fair inter-reader reliability in round 1 (mean kappa 0.36; range 0.06–0.69) and moderate intra-reader reliability (mean kappa 0.55; range 0.28–0.81). With the atlas, inter-reader reliability improved in round 1 to moderate (mean kappa 0.52; range 0.31–0.77) and intra-reader reliability to good (mean kappa 0.69; range 0.46–0.86). Higher intra-reader reliability was noted in participants with previous SGUS experience. The SGUS atlas increased both intra- and inter-reader reliability for scoring gland pathology in participants with varying SGUS experience suggesting a possible future role in clinical practice and trials. Key Points • Ultrasonography can detect parenchymal changes in salivary glands in patients with Sjögren’s disease. • An ultrasound atlas may improve reliability of scoring parenchymal changes in salivary glands.
With normal retinal blood flow, cross-sectional optical coherence tomography (OCT) of retinal vessels shows a structured intravascular reflectivity profile, resembling a 'figure-of-8'. Altered profiles have been reported in vascular occlusive and haematological diseases. Giant cell arteritis (GCA) can cause visual loss, usually due to anterior ischaemic optic neuropathy (AION) or retinal artery occlusion. Our aim was to extend the assessment of OCT vascular profiles to patients with suspected GCA and to determine if any abnormalities were related to GCA per se or to ischaemic ocular conditions. This nested retrospective study included 61 eyes of 31 patients (13 with GCA). Six eyes had arteritic and seven eyes non-arteritic AION, three eyes had non-arteritic retinal artery occlusion, 11 eyes had other ocular conditions and 34 were unaffected control eyes. For each eye the appearance of structured intravascular profiles on peripapillary OCT was graded as present, partial, absent or uncertain. Non-presence of structured intravascular profiles was more frequent in AION and retinal artery occlusion than in other ocular conditions or unaffected eyes (Fisher's test, p = .0047). Based on follow-up of 25 eyes, reflectivity profiles normalised in three out of four eyes after 85 (35-245) days. Vessel profiles were not associated with GCA (p = .32) and were similar in arteritic and non-arteritic AION (p = .66). In conclusion, absence of structured intravascular reflectivity profiles may be a marker of acute ischaemia in the anterior optic nerve or inner retina. However, it did not seem specific for GCA. The prognostic value warrants further studies.
Objectives To define the elementary ultrasound (US) lesions in giant cell arteritis (GCA) and to evaluate the reliability of the assessment of US lesions according to these definitions in a web-based reliability exercise. Methods Potential definitions of normal and abnormal US findings of temporal and extracranial large arteries were retrieved by a systematic literature review. As a subsequent step, a structured Delphi exercise was conducted involving an expert panel of the Outcome Measures in Rheumatology (OMERACT) US Large Vessel Vasculitis Group to agree definitions of normal US appearance and key elementary US lesions of vasculitis of temporal and extracranial large arteries. The reliability of these definitions on normal and abnormal blood vessels was tested on 150 still images and videos in a web-based reliability exercise. Results Twenty-four experts participated in both Delphi rounds. From originally 25 statements, nine definitions were obtained for normal appearance, vasculitis and arteriosclerosis of cranial and extracranial vessels. The 'halo' and 'compression' signs were the key US lesions in GCA. The reliability of the definitions for normal temporal and axillary arteries, the 'halo' sign and the 'compression' sign was excellent with inter-rater agreements of 91-99% and mean kappa values of 0.83-0.98 for both inter-rater and intra-rater reliabilities of all 25 experts. Conclusions The 'halo' and the 'compression' signs are regarded as the most important US abnormalities for GCA. The inter-rater and intra-rater agreement of the new OMERACT definitions for US lesions in GCA was excellent.
Objective.To assess the intrareader and interreader agreement and sensitivity to change of the Outcome Measures in Rheumatology (OMERACT) Rheumatoid Arthritis Magnetic Resonance Imaging Joint Space Narrowing (RAMRIS-JSN) score in the rheumatoid arthritis (RA) wrist in a longitudinal multireader exercise.MethodsCoronal T1-weighted MR image sets of 1 wrist from 20 patients with early RA were assessed twice for JSN at 17 sites at baseline and after 36 or 60 months by 4 readers blinded to patient data but not time order. The joints were scored 0–4 according to the OMERACT RAMRIS-JSN score. Intraclass correlation coefficients (ICC), smallest detectable change (SDC), percentage exact/close agreement (PEA/PCA), and standardized response mean (SRM) were calculated.Results.Median baseline and change score was 10.3 and 1.9, respectively. Intrareader ICC for baseline and change scores was good (≥ 0.50) to very good (≥ 0.80) for all and 3 of 4 readers, respectively. Interreader ICC was very good for change (0.93), while poor for baseline score if all 4 readers were included (0.36), but very good if 1 reader was excluded (0.87). Intrareader and interreader SDC was low (2.34–3.18), except for the intrareader SDC for 1 reader (6.75). The mean PEA/PCA was high for baseline and change scores both within and between the readers (51.5–99.2), except for interreader baseline PEA (14.4). SRM was moderate for all readers (0.55–0.77).Conclusion.The OMERACT RAMRIS-JSN score showed high overall intrareader and interreader reliability, and moderate sensitivity to change, supporting inclusion of the measure as part of the OMERACT RAMRIS system.
Efficient methods for diagnosis, monitoring, and prognostication are essential in early rheumatoid arthritis. Data on the value of ultrasonography and MRI are accumulating rapidly, fueling their increasing use in early rheumatoid arthritis. This review focuses on recent advances in the clinical applications of these imaging modalities.