The X-ray Integral Field Unit (X-IFU) is an imaging spectrometer based on a large array of Transition Edge Sensors (TES) measured using Time Domain Multiplexing (TDM). For the development of a backup detector array, we have designed and realized a cryogenic test setup capable of measuring 9 detectors in a single cooldown under DC bias. We have used this setup to study a small selection of low aspect ratio TES designs, intended to have a low normal resistance suitable for TDM readout. In this work we show how the different designs are affected by magnetic fields. We do this by presenting the impact on the transition shape, detector integrated Noise Equivalent Power (NEP), and sensitivity of the energy scale calibration. We find, in agreement with previous studies, that reducing the width of the TES bilayer greatly improves the detector resilience to magnetic fields, potentially by several orders of magnitude.
SRON (Netherlands Institute for Space Research) is developing the focal plane assembly (FPA) for Athena X-IFU, whose demonstration model (DM) will use for the first time a time domain multiplexing (TDM)-based readout system for the on-board transition-edge sensors (TES). We report on the characterization activities on a TDM setup provided by NASA goddard space flight center (GSFC) and national institute for standards and technology (NIST) and tested in SRON cryogenic test facilities. The goal of these activities is to study the impact of the longer harness, closer to X-IFU specs, in a different EMI environment and switching from a single-ended to a differential readout scheme. In this contribution we describe the advancement in the debugging of the system in the SRON cryostat, which led to the demonstration of the nominal spectral performance of 2.8 eV at 5.9 keV with 16-row multiplexing, as well as an outlook for the future endeavors for the TDM readout integration on X-IFU’s FPA-DM at SRON.
At SRON we have been developing X-ray TES micro-calorimeters as backup technology for the X-ray Integral Field Unit (X-IFU) of the Athena mission, demonstrating excellent resolving powers both under DC and AC bias. We also developed a frequency-domain multiplexing (FDM) readout technology, where each TES is coupled to a superconducting band-pass LC resonator and AC biased at MHz frequencies through a common readout line. The TES signals are summed at the input of a superconducting quantum interference device (SQUID), which performs a first amplification at cryogenic stage. Custom analog front-end electronics and digital boards take care of further amplifying the signals at room temperature and of the modulation/demodulation of the TES signals and bias carrier, respectively. We report on the most recent developments on our FDM technology, which involves a two-channel demonstration with a total of 70 pixels with a summed energy resolution of 2.34 +/- 0.02 eV at 5.9 keV without spectral performance degradation with respect to single-channel operation. Moreover, we discuss prospects towards the scaling-up to a larger multiplexing factor up to 78 pixels per channel in a 1-6 MHz readout bandwidth.
CNES (French Space Agency) is in charge of the development of the X-ray Integral Field Unit (X-IFU) instrument for Athena, the high resolution X-ray spectrometer of the ESA Athena X-ray Observatory. X-IFU will deliver spectra from 0.2 to 12 keV with a spectral resolution in the range of 2.5 eV up to 7 keV on a 5′′ pixels, with a field of view > 4′ equivalent diameter. The main sensor array detection chain is a key part of the instrument, being by far the main contributor to its performance. It involves major partners: NASA GFSC, NIST, SRON, VTT, APC, and IRAP. The cryo-harness interconnecting the Focal Plane Assembly cold interface to the Warm Front End Electronics is under CNES responsibility. The different technical solutions are the loom technology and the shielded twisted pair technology. Characterizations have been performed on breadboards to assess the crosstalk performances for each solution. The results of these analysis are a driver to perform the trade-off between the available cryo-harness technologies.
Several proposed space-based X-ray observatories apply TES-based micro-calorimeters as energy-dispersive imaging detector. The number of independently readout pixels is an important figure of merit for the scientific yield of such instruments. Design studies have shown that the power consumption of the SQUID readout is one of the driving design parameters which limits the maximum number of pixels which can be accommodated. Different multiplexing schemes, each with different properties and multiplexing factors have been proposed and demonstrated for the readout of the TES-based detectors. In an effort to estimate how the different readout multiplexing schemes differ in scalability for future space-based applications, we have made a comparison of the reported power consumption of the main multiplexing schemes currently under consideration for different space-based telescopes, i.e. time-domain multiplexing, frequency-domain multiplexing, and microwave SQUID multiplexing. It was found that, despite the different architectures and multiplexing factors, the power consumption per pixel at cryogenic temperatures is rather similar. We will analyze the origin of this phenomenon, and discuss directions of development to further improve on this number.
The X-ray Integral Field Unit (X-IFU) instrument is the high-resolution X-ray spectrometer of the ESA Athena X-ray Observatory. X-IFU will deliver spectra from 0.2 to 12 keV with a spectral resolution requirement of 4 eV (3 eV design goal) up to 7 keV from 5" pixels, with a hexagonal field of view of 4' equivalent diameter. The main sensor array and its associated detection chain is one of the major functional chains of the X-IFU instrument, and is the main contributor to X-IFU performance. CNES (Centre National d'Etudes Spatiales) is the prime contractor for the X-IFU and leads the project development and procurement aspects within the X-IFU Consortium; additional major partners of the main detection chain are NASA-GFSC, SRON, VTT, APC, NIST, IRAP, and IAP. The detection chain design for X-IFU has evolved in the past few years in order to secure the performances and development costs, in the frame of the New Athena mission. New TES pixels are implemented with slower time constant and a reduced sensitivity to magnetic field. The slower time constant directly allows an increase of the MUX factor and a reduction of the number of channels, together with the decrease of the number of proximity electronics boxes, or warm front end electronics (WFEE). The cryostat outer vessel temperature is now a 50 K thermal interface, cooled passively thanks to L-shaped thermal shield (L-grooves). This has a direct impact of the cryo-harness between the 4 K core interface and the WFEE interface. In the past years, we have performed early demonstration on the critical components in order to secure the detection chain design and performances. This paper presents the progress done on early demonstrations (warm electronics, cryo-harness breadboarding,...), while providing an update to the detection-chain design description.
We report on the x-ray background rate measured with transition-edge sensors (TES) micro-calorimeters under frequency-domain multiplexing (FDM) readout as a possible technology for future experiments aiming at a direct detection of axion-like particles. Future axion helioscopes will make use of large magnets to convert axions into photons in the keV range and x-ray detectors to observe them. To achieve this, a detector array with high spectral performance and extremely low background is necessary. TES are single-photon, non-dispersive, high-resolution micro-calorimeters and represent a possible candidate for this application. We have been developing x-ray TES micro-calorimeters and an FDM readout technology in the framework of the space-borne x-ray astronomical observatories. We show that the current generation of our detectors is already a promising technology for a possible axion search experiment, having measured an x-ray background rate of 2.2(2) × 10-4 cm-2 s-1 keV-1 with a cryogenic demonstrator not optimized for this specific application. We then make a prospect to further improve the background rate down to the required value (<10-7 cm-2 s-1 keV-1) for an axion-search experiment, identifying no fundamental limits to reach such a level.
With applications in cosmology, infrared astronomy and CMB survey, frequency-division multiplexing (FDM) proved to be a viable readout for transition-edge sensors (TESs). We investigate the occurrence of out-of-band resonances (OBR) which could constrain the bandwidth of the FDM readout of TES bolometers. The study includes SPICE modeling of the entire setup including the cryogenic harness, LC filters, Superconducting Quantum Interference Device (SQUID) and room-temperature amplifier. Simulation results show that the long harness (for flight model) could cause multiple reflections that generate repetitive spikes in the spectrum. Peaks of the OBR are mainly due to the parasitic capacitances at the input of SQUID. Implementing a low-pass RC circuit (snubber) at the input of the SQUID dampened the OBR. As a result, the first peak only appears around 20 MHz which is a safe margin for the 1 MHz - 3.8 MHz FDM in use in the prototype readout. Using a spectrum analyzer and broadband LNAs, we also measured the OBR for the prototype FDM readout in the laboratory up to 500 MHz. The measurement was conducted at temperatures of 50 mK and 4 K and for various biasing of the DC SQUID. It turns out that OBRs are more intense at 50 mK and are caused by the harness impedance mismatch rather than the SQUID. Simulation codes and supporting materials are available at https://github.com/githubamin/LT-Spice-Simulation-of-FDM-readout .
We present a characterization of the sensitivity of TES X-ray micro-calorimeters to environmental conditions under frequency-domain multiplexing (FDM) readout. In the FDM scheme, each TES in a readout chain is in series with a LC band-pass filter and AC biased with an independent carrier at MHz range. Using TES arrays, cold readout circuitry and warm electronics fabricated at SRON and SQUIDs produced at VTT Finland, we characterize the sensitivity of the detectors to bias voltage, bath temperature and magnetic field. We compare our results with the requirements for the Athena X-IFU instrument, showing the compliance of the measured sensitivities. We find in particular that FDM is intrinsically insensitive to the magnetic field because of TES design and AC readout.
We demonstrate multiplexed readout of 43 transition edge sensor (TES) bolometers operating at 90 mK using a frequency division multiplexing (FDM) readout chain with bias frequencies ranging from 1 to 3.5 MHz and a typical frequency spacing of 32 kHz. We improve the previously reported performance of our FDM system by two important steps. First, we replace the coplanar wires with microstrip wires, which minimize the cross talk from mutual inductance. From the measured electrical cross talk (ECT) map, the ECT of all pixels is carrier leakage dominated. Only five pixels show an ECT level higher than 1%. Second, we reduce the thermal response speed of the TES detectors by a factor of 20 by increasing the heat capacity of the TES, which allows us to bias all TES detectors below 50% in transition without oscillations. We compare the current-voltage curves and noise spectra of the TESs measured in single-pixel mode and multiplexing mode. We also compare the noise equivalent power (NEP) and the saturation power of the bolometers in both modes, where 38 pixels show less than 10% difference in NEP and 5% difference in saturation power when measured in the two different modes. The measured noise spectrum is in good agreement with the simulated noise based on measured parameters from an impedance measurement, confirming that our TES is dominated by phonon noise.
The X-ray Integral Field Unit (X-IFU) instrument is the high-resolution X-ray spectrometer of the ESA Athena X-ray Observatory. X-IFU will deliver spectra from 0.2 to 12 keV with a spectral resolution of 2.5 eV up to 7 keV from 5 '' pixels, with a hexagonal field of view of 5' equivalent diameter. The main sensor array and its associated detection chain is one of the major sub-systems of the X-IFU instrument, and is the main contributor to X-IFU's performance. CNES (the French Space Agency) is leading the development of X-IFU; additional major partners are NASA-GFSC, SRON, VTT, APC, NIST, and IRAP. This paper updates the B-phase definition of the X-IFU detection chain. The readout is based on time-division multiplexing (TDM). The different sub-components of the detection chain (the main sensor array, the cold electronics stages, and the warm electronics) require global design optimization in order to achieve the best performance. The detection chain's sensitivity to the EMI/EMC environment requires detailed analysis and implementation of dedicated design solutions. This paper focuses on these aspects while providing an update to the detection-chain design description.
We report on the development and demonstration of a MHz frequency domain multiplexing (FDM) technology to read out arrays of cryogenic transition edge sensor (TES) X-ray microcalorimeters. In our FDM scheme, TESs are AC-biased at different resonant frequencies in the low MHz range through an array of high-$Q$ LC resonators. The current signals of all TESs are summed at superconducting quantum interference devices (SQUIDs). We have demonstrated multiplexing for a readout of 31 pixels using room temperature electronics, high-$Q$ LC filters and TES arrays developed at SRON, and SQUID arrays from VTT. We repeated this on a second setup with 37 pixels. The summed X-ray spectral resolutions $@$ 5.9 keV are $\Delta E_{\rm 31 pix ~MUX}=2.14\pm0.03$ eV and $\Delta E_{\rm 37 pix ~MUX}=2.23\pm0.03$ eV. The demonstrated results are comparable with other multiplexing approaches. There is potential to further improve the spectral resolution and to increase the number of multiplexed TESs, and to open up applications for TES X-ray microcalorimeters.
In the frequency-domain multiplexing (FDM) scheme, transition-edge sensors (TESs) are individually coupled to superconducting LC filters and AC biased at MHz frequencies through a common readout line. To make efficient use of the available readout bandwidth and to minimize the effect of non-linearities, the LC resonators are usually designed to be on a regular grid. The lithographic processes, however, pose a limit on the accuracy of the effective filter resonance frequencies. Off-resonance bias carriers could be used to suppress the impact of intermodulation distortions, which, nonetheless, would significantly affect the effective bias circuit and the detector spectral performance. In this paper, we present a frequency shift algorithm (FSA) to allow off-resonance readout of TESs, while preserving the on-resonance bias circuit and spectral performance, demonstrating its application to the FDM readout of an x-ray TES microcalorimeter array. We discuss the benefits in terms of mitigation of the impact of intermodulation distortions at the cost of increased bias voltage and the scalability of the algorithm to multi-pixel FDM readout. We show that with FSA, in the multi-pixel and frequencies shifted on-grid, the line noises due to intermodulation distortion are placed away from the sensitive region in the TES response and the x-ray performance is consistent with the single-pixel, on-resonance level.
We demonstrate multiplexing readout of 60 transition edge sensor (TES) bolometers operating at 90 mK using a frequency division multiplexing readout chain with bias frequencies ranging from 1 to 3.5 MHz and with a typical frequency spacing of 32 kHz. The readout chain starts with a two-stage SQUID amplifier and has a noise level of 9.5 pA/Hz. We compare current–voltage curves and noise spectra of TESs measured in a single-pixel mode and in a multiplexing mode. We also map the noise equivalent power (NEP) and the saturation power of the bolometers in both modes, where there are 43 pixels that do not show more than 10% difference in NEP and 5% in saturation power when measured in single pixel and multiplex modes. We have read out a TES with an NEP of 0.45 aW/Hz in the multiplexing-mode, which demonstrates the capability of reading out ultra-low noise TES bolometer arrays for space applications.
Transition Edge Sensors (TESs) are the selected technology for future spaceborne X-ray observatories, such as Athena, Lynx, and HUBS. These missions demand thousands of pixels to be operated simultaneously with high energy-resolving power. To reach these demanding requirements, every aspect of the TES design has to be optimized. Here we present the experimental results of tests on different devices where the coupling between the x-ray absorber and the TES sensor is varied. In particular, we look at the effects of the diameter of the coupling stems and the distance between the stems and the TES bilayer. Based on measurements of the AC complex impedance and noise, we observe a reduction in the excess noise as the spacing between the absorber stem and the bilayer is decreased. We identify the origin of this excess noise to be internal thermal fluctuation noise between the absorber stem and the bilayer. Additionally, we see an impact of the coupling on the superconducting transition in the appearance of kinks. Our observations show that these unwanted structures in the transition shape can be avoided with careful design of the coupling geometry. Also the stem diameter appears to have a significant impact on the smoothness of the TES transition. This observation is still poorly understood, but is of great importance for both AC and DC biased TESs.
We have characterized and mapped the electrical cross talk (ECT) of a frequency division multiplexing (FDM) system with a transition edge sensor (TES) bolometer array, which is intended for space applications. By adding a small modulation at 120 Hz to the AC bias voltage of one bolometer and measuring the cross talk response in the current noise spectra of the others simultaneously, we have for the first time mapped the ECT level of 61 pixels with a nominal frequency spacing of 32 kHz in a 61 × 61 matrix and a carrier frequency ranging from 1 MHz to 4 MHz. We find that about 94% of the pixels show an ECT level of less than 0.4%. Only the adjacent pixels reach this level, and the ECT for the rest of the pixels is less than 0.1%. We also observe higher ECT levels, up to 10%, between some of the pixels, which have bundled long, parallel coplanar wires connecting TES bolometers to inductor-capacitor filters. In this case, the high mutual inductances dominate. To mitigate this source of ECT, the coplanar wires should be replaced by microstrip wires in the array. Our study suggests that an FDM system can have a relatively low ECT level, e.g., around 0.4% if the frequency spacing is 30 kHz. Our results successfully demonstrate a low electrical cross talk for a space FDM technology.
Superconducting transition-edge sensors (TESs) are highly sensitive detectors. Based on the outstanding performance on spectral resolution, the X-ray integral field unit (X-IFU) instrument on-board athena will be equipped with a large array of TES-based microcalorimeters. For optimal performance in terms of the energy resolution, it is essential to limit undesirable nonlinearity effects in the TES detector. Weak-link behavior induced on the TES by superconducting leads is such a nonlinearity effect. We designed and fabricated smart test structures to study the effect of the superconducting leads on the intrinsic transition curve of our TiAu-based TES bilayer. We measured and analyzed the resistance versus temperature transition curves of the test structures. We found relations of long-distance proximity effects with TES length and different lead materials. Based on these results, we can redesign and further optimize our TES-based X-ray detectors.
We are developing X-ray microcalorimeters as a backup option for the baseline detectors in the X-IFU instrument on board the ATHENA space mission led by ESA and to be launched in the early 2030s. 5×5 mixed arrays with TiAu transition-edge sensor (TES), which have different high aspect ratios and thus high resistances, have been designed and fabricated to meet the energy resolution requirement of the X-IFU instrument. Such arrays can also be used to optimise the performance of the Frequency Domain Multiplexing (FDM) readout and lead to the final steps for the fabrication of a large detector array. In this work we present the experimental results from tens of the devices with an aspect ratio (length-to-width) ranging from 1-to-1 up to 6-to-1, measured in a single-pixel mode with a FDM readout system developed at SRON/VTT. We observed a nominal energy resolution of about 2.5 eV at 5.9 keV at bias frequencies ranging from 1 to 5 MHz. These detectors are proving to be the best TES microcalorimeters ever reported in Europe, being able to meet not only the requirements of the X-IFU instrument, but also those of other future challenging X-ray space missions, fundamental physics experiments, plasma characterization and material analysis.
We are developing large TES arrays in combination with FDM readout for the next generation of X-ray space observatories. For operation under AC-bias, the TESs have to be carefully designed and optimized. In particular, the use of high aspect ratio devices will help to mitigate non-ideal behaviour due to the weak-link effect. In this paper, we present a full characterization of a TES array containing five different device geometries, with aspect ratios (width:length) ranging from 1:2 up to 1:6. The complex impedance of all geometries is measured in different bias configurations to study the evolution of the small-signal limit superconducting transition parameters, as well as the excess noise. We show that high aspect ratio devices with properly tuned critical temperatures (around 90 mK) can achieve excellent energy resolution, with an array average of 2.03 +- 0.17 eV at 5.9 keV and a best achieved resolution of 1.63 +- 0.17 eV. This demonstrates that AC-biased TESs can achieve a very competitive performance compared to DC-biased TESs. The results have motivated a push to even more extreme device geometries currently in development.
Frequency-domain multiplexing (FDM) is the baseline readout system for the X-ray Integral Field Unit on board the Athena mission. Under the FDM scheme, TESs are coupled to a passive LC filter and biased with alternating current (AC bias) at MHz frequencies. Using high-quality-factor LC filters and room-temperature electronics developed at SRON and low-noise two-stage SQUID amplifiers provided by VTT, we have recently demonstrated good performance with the FDM readout of Mo/Au TES calorimeters with Au/Bi absorbers. We have achieved a performance requested for the demonstration model with the single-pixel AC bias ($$\Delta E=1.8\,\hbox {eV}$$) and nine-pixel multiplexing ($$\Delta E=2.6\,\hbox {eV}$$) modes. We have also demonstrated 14-pixel multiplexing with an average energy resolution of 3.3 eV, which is limited by nonfundamental issues related to FDM readout in our laboratory setup.