We have developed the capability to detect and identify single fluorescent molecules as they transit a focused laser beam. Single molecule detection allows one to measure properties of individual molecules that would be difficult or impossible with bulk measurements where properties of individual molecules are hidden in ensemble averages. This attribute is particularly important for analyzing the components of a heterogeneous mixture without separating the sample into its individual components. The use of this technology for sizing individual DNA fragments in a sample containing a mixture of DNA fragments of different sizes is an excellent example of the power of this approach. In this article, we summarize our approach to single molecule detection and the application of this technology to DNA fragment sizing.
Single-species-level assays that would be difficult or impossible with conventional bulk measurements can now be performed with laser-induced fluorescence
During the past decade the sensitivity and selectivity of laser-induced fluorescence detection methods in liquids have been refined to the point where a molecule labeled with a single fluorophore dissolved in solution can be detected and identified as it flows through a focused excitation laser beam. Progress in this field is reviewed in a number of recent papers. [1-5]
We report on the study of the photodecomposition of single Rhodamine 6G (R6G) dye molecules adsorbed on silver nanoparticles. The nanoparticles were immobilized and spatially isolated on polylysine-derivatized glass coverslips, and confocal laser microspectroscopy was used to obtain surface-enhanced Raman scatters (SERS) spectra from individual R6G molecules. The photodecomposition of these molecules was observed with 150-ms temporal resolution. The photoproduct was identified as graphitic carbon based on the appearance of bread SERS vibrational bands at 1592 cm-1 and 1340 cm-1 observed in both bulk and averaged single-molecule photoproduct spectra. In contrast, when observed at the single-molecule level, the photoproduct yielded sharp SERS spectra. The inhomogeneous broadening of the bulk SERS spectra is due to a variety of photoproducts in different surface orientations and is a characteristic of ensemble-averaged measurement of disordered systems. These single-molecule studies indicate a photodecomposition pathway by which the R6G molecule desorbs from the metal surface, an excited-state photoreaction occurs, and the R6G photoproduct(s) readsorbs to the surface. A SERS spectrum is obtained when either the intact R6G or the R6G photoproduct(s) are adsorbed on a SERS-active site. This work further illustrates the power of single-molecule spectroscopy (SMS) to reveal unique behaviors of single molecules that are not discernable with bulk measurements.
The rate of detection and sizing of individual fluorescently labeled DNA fragments in conventional single-molecule flow cytometry (SMFC) is limited by optical saturation, photon-counting statistics, and fragment overlap to approximately 100 fragments/s. We have increased the detection rate for DNA fragment sizing in SMFC to approximately 2000 fragments/s by parallel imaging of the fluorescence from individual DNA molecules, stained with a fluorescent intercalating dye, as they passed through a planar sheet of excitation laser light, resulting in order of magnitude improvements in the measurement speed and the sample throughput compared to conventional SMFC. Fluorescence bursts were measured from a fM solution of DNA fragments ranging in size from 7 to 154 kilobase pairs. A data acquisition time of only a few seconds was sufficient to determine the DNA fragment size distribution. A linear relationship between the number of detected photons per burst and the DNA fragment size was confirmed. Application of this parallel fluorescence imaging method will lead to improvements in the speed, throughput, and sensitivity of other types of flow-based analyses involving the study of single molecules, chromosomes, cells, etc.
We report on various excitation geometries used in ultrasensitive flow cytometry that yield a linear relation between the fluorescence intensity measured from individual stained DNA fragments and the lengths of the fragments (in base pairs). This linearity holds for DNA samples that exhibit a wide range of conformations. The variety of DNA conformations leads to a distribution of dipole moment orientations for the dye molecules intercalated into the DNA. It is consequently important to use an excitation geometry such that all dye molecules are detected with similar efficiency. To estimate the conformation and the extent of elongation of the stained fragments in the flow, fluorescence polarization anisotropy and autocorrelation measurements were performed. Significant extension was observed for DNA fragments under the flow conditions frequently used for DNA fragment sizing. Classical calculations of the fluorescence emission collected over a finite solid angle are in agreement with the experimental measurements and have confirmed the relative insensitivity to DNA conformation of an orthogonal excitation geometry. Furthermore, the calculations suggested a modified excitation geometry that has increased our sizing resolution.
AbstractChemInform is a weekly Abstracting Service, delivering concise information at a glance that was extracted from about 100 leading journals. To access a ChemInform Abstract of an article which was published elsewhere, please select a “Full Text” option. The original article is trackable via the “References” option.
Using laser scanning confocal optics in conjunction with avidin/biotin technology, micrometer-sized patterns of biomolecules were fabricated on glassy-carbon and fused-silica surfaces. Photoactive biotin was immobilized using the 325-nm line of a Helium-Cadmium laser, which was focused through a 25x or 100x quartz microscope objective. A three-dimensional piezoelectric micromanipulator was used to position the sample surface in the focal plane of the microscope objective and to create patterns on the focused surface. Biotin patterns with line widths of 5-20 microns were produced by varying the scan speed of the micromanipulator while exposing the surface to the laser. The integrity of the immobilized biotin was confirmed by subsequent derivatization with fluorescently labeled avidin. Fluorescence microscopy with a cooled charge coupled device (CCD) imaging system was used to visualize the distribution of biotin and fluorescent avidin within the patterns created by the laser.
Excitation of fluorescence with total internal reflection (TIR) excitation yields very low background scattered light and good signal-to-background contrast. The background and its associated noise can be made low enough to detect single fluorescent molecules under ambient conditions. In this paper, different TIR geometries were compared for excitation and detection of single rhodamine 6G (R6G) molecules at air-silica interfaces and single B-phycoerythrin proteins at water-silica interfaces. Through-objective, objective-coverslip, and prism-based TIR geometries were investigated. The signal-to-background ratio (SBR) and the number of photons detected before photobleaching (Nb) were optimum in different geometries. The greatest image contrast was obtained when using prism-TIR (SBR = 11.5), but the largest number of detected signal photoelectrons was obtained by using through-objective TIR for R6G-air-silica ( = 10(4)). The results were discussed in terms of the TIR field enhancements and the modified dipole emission pattern near a dielectric interface. The SBR and total detected photons are important parameters for designing photon-limited experiments.
High-throughput screening of large combinatorial chemical libraries in biochemical assays will benefit from reduced reagent volume and increased speed of measurement. Standard assays typically are performed in 96-well microtiter plates having 200-microL well volumes and up to an hour of incubation time. In this paper, we demonstrate a technique for precise and rapid measurement of the progress of an enzymatic reaction and its inhibition with reduced volume and time (for this work, the assay was mixed at the 200-microL level and detected in 2-microL volumes with minutes of total assay time). Directly measuring the enzyme activity in the small volume format yields a precise value for the median inhibitory concentration (IC50) of an inhibitor compound. The model assay is the endoproteolytic cleavage of a small fluorogenic peptide by human neutrophil collagenase (MMP-8). The fluorogenic peptide was labeled at one end with a UV/blue fluorophore (N-methylanthranilyl) and at the other end with a quencher (dinitrophenol). To generate inhibition data, a hydroxamate peptide analog inhibitor of collagenase, actinonin, was included in the reaction. The experiments were performed using ultraviolet laser illumination (325 nm wavelength) and parallel fluorescence detection by a cooled, charge-coupled-device camera system to increase sensitivity and speed. The assay volume was reduced to 2 microL for data collection, and the total time for mixing, incubation, and measurement was less than 6 min. For comparison to a standard format, the same assay was performed in a 96-well microtiter plate in 200 microL using 30 min of incubation and measurement in a microtiter plate fluorimeter. Median inhibitory concentrations (IC50) for actinonin of 73 +/- 16 and 100 +/- 14 nM were obtained in the 2- and 200-microL assays, respectively. One concern with assay miniaturization and increases in throughput is a potential loss of precision and accuracy. Laser excitation and parallel detection of fluorescence is a promising approach for increased speed and reduced cost without loss of precision for proteinase inhibition assays.
We present a new mathematical approach for calculating burst size distributions for the detection of fluorescent molecules introduced into a fluid flow at different rates. The burst size distributions reflect the passage of more than one molecule through the detection volume in close succession. The calculations are based upon a physical model appropriate for the fluorophore phycoerythrin under the conditions of no saturation of excitation, negligible triplet-state dynamics, and negligible detector dead time. The model includes photophysical properties of the fluorophore phycoerythrin (absorption cross section, fluorescence quantum yield, and photostability); diffusion; sample stream hydrodynamics; spatially dependent optical detection efficiency; and excitation laser beam characteristics. Good agreement is found between the mathematical model and experimental results with phycoerythrin.
Heterogeneity in the environments of molecules affects their photophysical parameters. Changes in the local environments or changes within the molecules themselves produces fluctuations in the photophysical parameters. We have explored the fluorescence lifetime and intensity fluctuations of Rhodamine 6G on silica using time correlated single photon counting combined with near-field and far-field scanning optical microscopies, and fluorescence photon-pair correlation measurements in far-field microscopy. In the most recent work, we find complex behavior in the fluorescence lifetime and emission intensity in the millisecond to minute time range that must be associated with changes in both the non-radiative and the radiative decay rates.
An overview of our recent results in modeling single molecule detection in fluid flow is presented. Our mathematical approach is based on a path integral representation. The model accounts for all experimental details, such as light collection, laser excitation, hydrodynamics and diffusion, and molecular photophysics. Special attention is paid to multiple molecule crossings through the detection volume. Numerical realization of the theory is discussed. Measurements of burst size distributions in single B-phycoerythrin molecule detection experiments are presented and compared with theoretical predictions.