Introduction:Divers often increase their fraction of inspired oxygen (FIO₂) to decrease their risk of decompression sickness. However, breathing elevated pressures of oxygen can cause central nervous system oxygen toxicity (CNS-OT). This study aimed to review the literature describing the effect of hyperoxia on the electroencephalogram (EEG), thus exploring the potential for real-time detection of an impending CNS-OT seizure. Methods:We searched Medline, Embase, Scopus, and Web of Science for articles that reported EEG measures accompanying hyperoxic ventilation (FIO₂ = 1.0 ± hyperbaric pressure) in healthy participants. We included peer-reviewed journal articles, books, and government reports with no language or date restrictions. Randomised controlled trials and cross-over studies were included; case reports were excluded. We used the Newcastle-Ottawa scale to evaluate evidence quality. Results:Our search strategy returned 1,025 unique abstracts; we analysed the full text of 46 articles; 22 articles (16 studies) were included for review. Study cohorts were typically small and comprised of male non-divers. We discovered a variety of EEG analysis methods: studies performed spectral analysis (n = 12), the analysis of sensory-evoked potentials (n = 4), connectivity/complexity analysis (n = 3), source localisation (n = 1), and expert qualitative analyses (n = 4). Studies of severe exposures (long duration at hyperbaric pressure) typically reported qualitative measures, and studies of mild exposures typically reported quantitative measures. Conclusions:There is a need for a large randomised controlled trial reporting quantitative measures to better understand the effect of hyperoxia on the EEG, thus enabling the development of real-time monitoring of CNS-OT risk.
BACKGROUND:Scuba diving is an increasingly popular activity that involves the use of specialized equipment and compressed air to breathe underwater. Scuba divers are subject to the physiological consequences of being immersed in a high-pressure environment, including, but not limited to, increased work of breathing and kinetic energy expenditure, decreased fluid absorption, and alteration of metabolism. Individual response to these environmental stressors may result in a differential risk of decompression sickness, a condition thought to result from excess nitrogen bubbles forming in a diver's tissues. While the mechanisms of decompression sickness are still largely unknown, it has been postulated that this response may further be influenced by the diver's health status. Nutritional intake has direct relevancy to inflammation status and oxidative stress resistance, both of which have been associated with increased decompression stress. While nutritional recommendations have been determined for saturation divers, these recommendations are likely overly robust for recreational divers, considering that the differences in time spent under pressure and the maximum depth could result nonequivalent energetic demands. Specific recommendations for recreational divers remain largely undefined. METHODS:This narrative review will summarize existing nutritional recommendations and their justification for recreational divers, as well as identify gaps in research regarding connections between nutritional intake and the health and safety of divers. RESULTS:Following recommendations made by the Institute of Medicine and the Naval Medical Research Institute of Bethesda, recreational divers are advised to consume ~170-210 kJ·kg-1 (40-50 kcal·kg-1) body mass, depending on their workload underwater, in a day consisting of 3 hours' worth of diving above 46 msw. Recommendations for macronutrient distribution for divers are to derive 50% of joules from carbohydrates and less than 30% of joules from fat. Protein consumption is recommended to reach a minimum of 1 g of protein·kg-1 of body mass a day to mitigate loss of appetite while meeting energetic requirements. All divers should take special care to hydrate themselves with an absolute minimum of 500 ml of fluid per hour for any dive longer than 3 hours, with more recent studies finding 0.69 liters of water two hours prior to diving is most effective to minimize bubble loads. While there is evidence that specialized diets may have specific applications in commercial or military diving, they are not advisable for the general recreational diving population considering the often extreme nature of these diets, and the lack of research on their effectiveness on a recreational diving population. CONCLUSIONS:Established recommendations do not account for changes in temperature, scuba equipment, depth, dive time, work of breathing, breathing gas mix, or individual variation in metabolism. Individual recommendations may be more accurate when accounting for basal metabolic rate and physical activity outside of diving. However, more research is needed to validate these estimates against variation in dive profile and diver demographics.
The risks of diving have been discussed as a critical problem due to the aging diving population. According to the Divers Alert Network (DAN) 2020 estimates, over 40% of underwater illnesses are related to the heart. Monitoring the heart rate of divers underwater and create a warning system would reduce the number of diving accidents. However, it remains a challenge to reliably measure heart rate in the aqueous environment due to the underwater signal detection and transmission. In this study, we report on the development of a mussel-inspired PAA/DA/ChCl hydrogel designed for usage in saltwater environments Our results demonstrate its favorable characteristics, including good swelling ratio and wet adhesion properties in saltwater. Additionally, to assess its practical viability, this ionic-based hydrogel was evaluated in a diver physiological monitoring system as an ECG electrode for real-time underwater heart rate monitoring in both salt and freshwater, under static and dynamic conditions. Consequently, our findings suggest the material's potential for capturing underwater impedance signals and its suitability for integration into future underwater warning systems.
Introduction: Hypoxia can cause central nervous system dysfunction and injury. Hypoxia is a particular risk during rebreather diving. Given its subtle symptom profile and its catastrophic consequences there is a need for reliable hypoxia monitoring. Electroencephalography (EEG) is being investigated as a real time monitor for multiple diving problems related to inspired gas, including hypoxia. Methods: A systematic literature search identified articles investigating the relationship between EEG changes and acute cerebral hypoxia in healthy adults. Quality of clinical evidence was assessed using the Newcastle-Ottawa scale. Results: Eighty-one studies were included for analysis. Only one study investigated divers. Twelve studies described quantitative EEG spectral power differences. Moderate hypoxia tended to result in increased alpha activity. With severe hypoxia, alpha activity decreased whilst delta and theta activities increased. However, since studies that utilised cognitive testing during the hypoxic exposure more frequently reported opposite results it appears cognitive processing might mask hypoxic EEG changes. Other analysis techniques (evoked potentials and electrical equivalents of dipole signals), demonstrated sustained regulation of autonomic responses despite worsening hypoxia. Other studies utilised quantitative EEG analysis techniques, (Bispectral index [BISTM], approximate entropy and Lempel-Ziv complexity). No change was reported in BISTM value, whilst an increase in approximate entropy and Lempel-Ziv complexity occurred with worsening hypoxia. Conclusions: Electroencephalographic frequency patterns change in response to acute cerebral hypoxia. There is paucity of literature on the relationship between quantitative EEG analysis techniques and cerebral hypoxia. Because of the conflicting results in EEG power frequency analysis, future research needs to quantitatively define a hypoxia-EEG response curve, and how it is altered by concurrent cognitive task loading.
Introduction:Capnography aids assessment of the adequacy of mechanical patient ventilation. Physical and physiological changes in hyperbaric environments create ventilation challenges which make end-tidal carbon dioxide (ETCO2) measurement particularly important. However, obtaining accurate capnography in hyperbaric environments is widely considered difficult. This study investigated the EMMA capnograph for hyperbaric use.Methods:We compared the EMMA capnograph to sidestream capnography and the gold standard arterial carbon dioxide blood gas analysis in a hyperbaric chamber. In 12 resting subjects breathing air at 284 kPa, we recorded ETCO2 readings simultaneously derived from the EMMA and sidestream capnographs during two series of five breaths (total 24 measurements). An arterial blood gas sample was also taken simultaneously in five participants.Results:Across all measurements there was a difference of about 0.1 kPa between the EMMA and sidestream capnographs indicating a very slight over-estimation of ETCO2 by the EMMA capnograph, but fundamentally good agreement between the two end-tidal measurement methods. Compared to arterial blood gas pressure the non-significant difference was about 0.3 and 0.4 kPa for the EMMA and sidestream capnographs respectively.Conclusions:In this study, the EMMA capnograph performed equally to the sidestream capnograph when compared directly, and both capnography measures gave clinically acceptable estimates of arterial PCO2.
Support-vector machines (SVMs) can potentially improve patient monitoring during nitrous oxide anaesthesia. By elucidating the effects of low-dose nitrous oxide on the power spectra of multi-channel EEG recordings, we quantified the degree to which these effects generalise across participants. In this single-blind, cross-over study, 32-channel EEG was recorded from 12 healthy participants exposed to 0, 20, 30 and 40% end-tidal nitrous oxide. Features of the delta-, theta-, alpha- and beta-band power were used within a 12-fold, participant-wise cross-validation framework to train and test two SVMs: (1) binary SVM classifying EEG during 0 or 40% exposure (chance = 50%); (2) multi-class SVM classifying EEG during 0, 20, 30 or 40% exposure (chance = 25%). Both the binary (accuracy 92%) and the multi-class (accuracy 52%) SVMs classified EEG recordings at rates significantly better than chance (p < 0.001 and p = 0.01, respectively). To determine the relative importance of frequency band features for classification accuracy, we systematically removed features before re-training and re-testing the SVMs. This showed the relative importance of decreased delta power and the frontal region. SVM classification identified that the most important effects of nitrous oxide were found in the delta band in the frontal electrodes that was consistent between participants. Furthermore, support-vector classification of nitrous oxide dosage is a promising method that might be used to improve patient monitoring during nitrous oxide anaesthesia.
Recreational scuba divers venture underwater to explore the underwater world or perform jobs like monitoring, data collection or just sightseeing. Deeper and longer divers increase the complexity of diving, like additional and different gases, more equipment and increased planning. These complex dives also increase the levels of physiological exposure. Divers are taught how to manage the risks of physiological challenges like decompression, hypercapnia, hypoxia, hyperoxia, nitrogen narcosis and hypothermia. Xavier will discuss these physiological challenges and the technological possibilities and opportunities to monitor or overcome them.
Introduction:Air flow in full-face snorkel masks (FFSMs) should be unidirectional to prevent rebreathing of exhaled air. This study evaluated rebreathing and its consequences when using FFSMs compared to a conventional snorkel.Methods:In a dry environment 20 participants wore three types of snorkel equipment in random order: Subea Easybreath FFSM; QingSong 180-degree panoramic FFSM; and a Beuchat Spy conventional snorkel (with nose clip), in three conditions: rest in a chair; light; and moderate intensity exercise on a cycle ergometer. Peripheral oxygen saturation, partial pressure of carbon dioxide (PCO2) and oxygen (PO2) in the end tidal gas and FFSM eye-pockets, respiratory rate, minute ventilation, were measured continuously. Experiments were discontinued if oxygen saturation dropped below 85%, or if end-tidal CO2 exceeded 7.0 kPa.Results:Experimental runs with the FFSMs had to be discontinued more often after exceeding 7.0 kPa end-tidal CO2 compared to a conventional snorkel e.g., 18/40 (45%) versus 4/20 (20%) during light intensity exercise, and 9/22 (41%) versus 3/16 (19%) during moderate intensity exercise. Thirteen participants exhibited peripheral oxygen saturations below 95% (nine using FFSMs and four using the conventional snorkel) and five fell below 90% (four using FFSMs and one using the conventional snorkel). The PCO2 and PO2 in the eye-pockets of the FFSMs fluctuated and were significantly higher and lower respectively than in inspired gas, which indicated rebreathing in all FFSM wearers.Conclusions:Use of FFSMs may result in rebreathing due to non-unidirectional flow, leading to hypercapnia and hypoxaemia.
We have read with great interest the review by Mankowska et al. [...]
Divers commonly breathe air, containing nitrogen. Nitrogen under hyperbaric conditions is a narcotic gas. In dives beyond a notional threshold of 30 m depth (405 kPa) this can cause cognitive impairment, culminating in accidents due to poor decision making. Helium is known to have no narcotic effect. This study explored potential approaches to developing an electroencephalogram (EEG) functional connectivity metric to measure narcosis produced by nitrogen at hyperbaric pressures. Twelve human participants (five female) breathed air and heliox (in random order) at 284 and 608 kPa while recording 32-channel EEG and psychometric function. The degree of spatial functional connectivity, estimated using mutual information, was summarized with global efficiency. Air-breathing at 608 kPa (experienced as mild narcosis) caused a 35% increase in global efficiency compared to surface air-breathing (mean increase = 0.17, 95% CI [0.09–0.25], p = 0.001). Air-breathing at 284 kPa trended in a similar direction. Functional connectivity was modestly associated with psychometric impairment (mixed-effects model r 2 = 0.60, receiver-operating-characteristic area, 0.67 [0.51–0.84], p = 0.02). Heliox breathing did not cause a significant change in functional connectivity. In conclusion, functional connectivity increased during hyperbaric air-breathing in a dose-dependent manner, but not while heliox-breathing. This suggests sensitivity to nitrogen narcosis specifically.
AbstractDivers breathe higher partial pressures of oxygen at depth than at the surface. The literature and diving community are divided on whether or not oxygen is narcotic. Conversely, hyperbaric oxygen may induce dose‐dependent cerebral hyperexcitability. This study evaluated whether hyperbaric oxygen causes similar narcotic effects to nitrogen, and investigated oxygen's hyperexcitability effect. Twelve human participants breathed “normobaric” air and 100% oxygen, and “hyperbaric” 100% oxygen at 142 and 284 kPa, while psychometric performance, electroencephalography (EEG), and task load perception were measured. EEG was analyzed with functional connectivity and temporal complexity algorithms. The spatial functional connectivity, estimated using mutual information, was summarized with the global efficiency network measure. Temporal complexity was calculated with a “default‐mode‐network (DMN) complexity” algorithm. Hyperbaric oxygen‐breathing caused no change in EEG global efficiency or in the psychometric test. However, oxygen caused a significant reduction of DMN complexity and a reduction in task load perception. Hyperbaric oxygen did not cause the same changes in EEG global efficiency seen with hyperbaric air, which likely related to a narcotic effect of nitrogen. Hyperbaric oxygen seemed to disturb the time evolution of EEG patterns that could be taken as evidence of early oxygen‐induced cortical hyperexcitability. These findings suggest that hyperbaric oxygen is not narcotic and will help inform divers' decisions on suitable gas mixtures.
WHY DID I DO IT? Divers venturing underwater, either for work or pleasure, may experience narcotic effects caused by their breathing gases. The onset of narcosis symptoms is expected around 30 m (405 kPa) when breathing air. The principal hazard of gas narcosis is euphoria, overconfidence and loss of judgement. This may cause the diver to become less alert, take extra risks and start a chain of events culminating in a severe diving accident. No early warning signal is available. Therefore, an objective method to detect narcosis could improve diver safety by characterising the related effects of each component in the breathing gas mixture, allowing the diver to make informed choices about gas mix composition and facilitating related research.
Arterial blood gas measurements at both maximum depth and the surface before breathing on the same dive have not previously been obtained during deep breath-hold dives in cold open-water conditions and competition dive format. Such measurements were obtained in two dives to 60 m (197′) of 2 min duration. Changes in arterial oxygen and carbon dioxide (an increase during descent, and a decrease during ascent) support previous observations in less extreme dives and environments.
BACKGROUND:Nitrous oxide produces non-γ-aminobutyric acid sedation and psychometric impairment and can be used as scientific model for understanding mechanisms of progressive cognitive disturbances. Temporal complexity of the electroencephalogram may be a sensitive indicator of these effects. This study measured psychometric performance and the temporal complexity of the electroencephalogram in participants breathing low-dose nitrous oxide.METHODS:In random order, 20, 30, and 40% end-tidal nitrous oxide was administered to 12 participants while recording 32-channel electroencephalogram and psychometric function. A novel metric quantifying the spatial distribution of temporal electroencephalogram complexity, comprised of (1) absolute cross-correlation calculated between consecutive 0.25-s time samples; 2) binarizing these cross-correlation matrices using the median of all channels as threshold; (3) using quantitative recurrence analysis, the complexity in temporal changes calculated by the Shannon entropy of the probability distribution of the diagonal line lengths; and (4) overall spatial extent and intensity of brain complexity, was quantified by calculating median temporal complexity of channels whose complexities were above 1 at baseline. This region approximately overlay the brain's default mode network, so this summary statistic was termed "default-mode-network complexity."RESULTS:Nitrous oxide concentration correlated with psychometric impairment (r = 0.50, P < 0.001). Baseline regional electroencephalogram complexity at midline was greater than in lateral temporal channels (1.33 ± 0.14 bits vs. 0.81 ± 0.12 bits, P < 0.001). A dose of 40% N2O decreased midline (mean difference [95% CI], 0.20 bits [0.09 to 0.31], P = 0.002) and prefrontal electroencephalogram complexity (mean difference [95% CI], 0.17 bits [0.08 to 0.27], P = 0.002). The lateral temporal region did not change significantly (mean difference [95% CI], 0.14 bits [-0.03 to 0.30], P = 0.100). Default-mode-network complexity correlated with N2O concentration (r = -0.55, P < 0.001). A default-mode-network complexity mixed-effects model correlated with psychometric impairment (r2 = 0.67; receiver operating characteristic area [95% CI], 0.72 [0.59 to 0.85], P < 0.001).CONCLUSIONS:Temporal complexity decreased most markedly in medial cortical regions during low-dose nitrous oxide exposures, and this change tracked psychometric impairment.EDITOR’S PERSPECTIVE:
Introduction: Critical flicker fusion frequency (CFFF) has been used in various studies to measure the cognitive effects of gas mixtures at depth, sometimes with conflicting or apparently paradoxical results. This study aimed to evaluate a novel automatic CFFF method and investigate whether CFFF can be used to monitor gas-induced narcosis in divers. Methods: Three hyperbaric chamber experiments were performed: 1) Automated and manual CFFF measurements during air breathing at 608 kPa (n = 16 subjects); 2) Manual CFFF measurements during air and heliox breathing at sea level (101.3 kPa) and 608 kPa (n = 12); 3) Manual CFFF measurements during oxygen breathing at sea level, 142 and 284 kPa (n = 10). All results were compared to breathing air at sea level. Results: Only breathing oxygen at sea level, and at 284 kPa, caused a significant decrease in CFFF (2.5% and 2.6% respectively compared to breathing air at sea level. None of the other conditions showed a difference with sea level air breathing. Conclusions: CFFF did not significantly change in our experiments when breathing air at 608 kPa compared to air breathing at sea level pressure using both devices. Based on our results CFFF does not seem to be a sensitive tool for measuring gas narcosis in divers in our laboratory setting.
INTRODUCTION In 2018 12 children and one adult were anaesthetised before being extricated through over a kilometre of flooded cave in Thailand. Full face dive masks (FFMs) putatively capable of maintaining constant positive airway pressure (CPAP) were employed. Here we describe the anaesthetic intervention and investigate the CPAP capability of the FFM. METHODS Pressure was measured inside and outside the Interspiro Divator FFM during 10 tidal and 10 vital capacity breaths in divers at the surface and submerged with the mask deployed on open-circuit scuba (10 divers); and a closed-circuit rebreather (five divers). Relative in-mask pressure was calculated as the difference between inside and outside pressures. We also measured the in-mask pressure generated by activation of the second stage regulator purge valve in open-circuit mode. RESULTS When submerged in open-circuit mode the mean relative in-mask pressure remained positive in normal tidal breathing (inhalation 0.6 kPa [95% CI 0.3-0.9]; exhalation 1.1 [0.8-1.4]) and vital capacity breathing (inhalation 0.8 [0.4-1.1]; exhalation 1.2 [0.9-1.4]). As expected, the relative in-mask pressure was predominantly negative when used on closed-circuit with back mounted counter-lungs due to a negative static lung load. Mean in-mask pressure during purge valve operation was 3.99 kPa (approximately equal to 40 cmH2O) (range: 2.56 to 5.3 kPa). CONCLUSIONS The CPAP function of the Interspiro Divator FFM works well configured with open-circuit scuba. This may have contributed to the success of the Thailand cave rescue. Caution is required in generalising this success to other diving scenarios.
INTRODUCTION:Gas narcosis impairs divers when diving deeper. Pupillometry is sensitive to alcohol intoxication and it has been used in anaesthesia to assess nitrous oxide narcosis. It is a potential novel method to quantify narcosis in diving. The aim of this study was to evaluate pupillometry for objective measurement of narcosis during exposure to hyperbaric air or nitrous oxide.METHOD:Pupil size in 16 subjects was recorded directly at surface pressure and during air breathing at 608 kPa (equivalent to 50 metres' seawater depth) in a hyperbaric chamber. Another 12 subjects were exposed to nitrous oxide at end-tidal percentages of 20, 30 and 40% in random order at surface pressure. Pupil size and pupil light reflex were recorded at baseline and at each level of nitrous oxide exposure.RESULTS:Pupil size did not significantly change during exposure to hyperbaric air or nitrous oxide. The pupil light reflex, evaluated using percentage constriction and minimum diameter after exposure to a light stimulus, was affected significantly only during the highest nitrous oxide exposure - an end-tidal level of 40%.CONCLUSION:Pupillometry is insensitive to the narcotic effect of air at 608 kPa in the dry hyperbaric environment and to the effects of low dose nitrous oxide. Pupillometry is not suitable as a monitoring method for gas narcosis in diving.