RATIONALE:Liquid chromatography/tandem mass spectrometry (LC/MS/MS) is the gold standard of urine drug testing. However, current LC-based methods are time consuming, limiting the throughput of MS-based testing and increasing the cost. This is particularly problematic for quantification of drugs such as phenobarbital, which is often analyzed in a separate run because they must be negatively ionized.METHODS:This study examined the feasibility of using a dilute-and-shoot flow-injection method without LC separation to quantify drugs with phenobarbital as a model system. Briefly, a urine sample containing phenobarbital was first diluted by 10 times, followed by flow injection of the diluted sample to mass spectrometer. Quantification and detection of phenobarbital were achieved by an electrospray negative ionization MS/MS system operated in the multiple reaction monitoring (MRM) mode with the stable-isotope-labeled drug as internal standard.RESULTS:The dilute-and-shoot flow-injection method developed was linear with a dynamic range of 50-2000 ng/mL of phenobarbital and correlation coefficient > 0.9996. The coefficients of variation and relative errors for intra- and inter-assays at four quality control (QC) levels (50, 125, 445 and 1600 ng/mL) were 3.0% and 5.0%, respectively. The total run time to quantify one sample was 2 min, and the sensitivity and specificity of the method did not deteriorate even after 1200 consecutive injections.CONCLUSIONS:Our method can accurately and robustly quantify phenobarbital in urine without LC separation. Because of its 2 min run time, the method can process 720 samples per day. This feasibility study shows that the dilute-and-shoot flow-injection method can be a general way for fast analysis of drugs in urine. Copyright © 2016 John Wiley & Sons, Ltd.
BMCL26 is a potential drug derived from nimesulide, which has exhibited the substantial anti-parasitic activity in various cell lines. To conduct various pharmacological and toxicological properties of this drug, we developed and validated a rapid LC-MS/MS method for its quantification in accordance with the FDA guidelines. Protein precipitation with 0.1% formic acid in acetonitrile was used to extract the analytes along with the internal standard (JCC76) from rat plasma. It was found that the calibration curve of the method had an excellent linearity (r2 ≥ 0.9993) for the analyte concentration ranging from 0.5 to 100 ng/mL with acceptable inter- and intra-assay, precision, accuracy and stability. The matrix effect and extraction recovery were in the range of 101.30-110.10% and 90.16- 105.00%, respectively. This LC-MS/MS method is simple and rapid and can be used in the future pharmaceutical studies of BMCL26.
CSUOH0901, a novel anticancer derivative of nimesulide, exhibits very promising anticancer activities in various cancer cell lines. In order to support further pharmacological and toxicological studies of this promising anticancer drug candidate, an LC-MS/MS method was developed and validated in accordance with the US Food and Drug Administration guidelines. The drug molecules were extracted from plasma samples by protein precipitation and then analyzed with LC-ESI-MS/MS. An excellent analyte separation was achieved using a phenomenex C18 column with a mobile phase of 90% methanol and 5 m m of ammonium formate. The validated linear dynamic range was between 0.5 and 100 ng/mL and the achieved correlation coefficient (r(2)) was >0.9996. The results of inter- and intra-day precision and accuracy were satisfactory, that is, <12% for accuracy and within ±5% for precision at a low and high quality control concentrations, respectively. In addition, the analyte and internal standard (JCC76) were found to be stable under the storage conditions at -20°C for about 2 months. Hence, the acquired results proved that the LC-ESI-MS/MS method developed is precise, accurate and selective for the quantification of CSUOH0901 in plasma, and can be used for pharmacokinetic studies.
We report a method for expressing the solvent accessibility of histidine imidazole groups in proteins. The method is based on measuring the rate of the hydrogen exchange (HX) reaction of the imidazole Cε1-hydrogen. The rate profile of the HX reaction as a function of pH gives a sigmoidal curve, which reaches the maximal rate constant (kmax) on the alkaline side of the sigmoidal curve. To quantitatively describe the solvent accessibility of imidazole groups in proteins, it is necessary to compare the kmax of the imidazole groups with their intrinsic kmax (ikmax), the maximal rate constants for the given imidazole groups when they are fully exposed to the bulk solvent. However, the mechanism of the HX reaction suggests that the ikmax of an imidazole group differs depending on its pKa, and no systematic study has been conducted to clarify how the ikmax is affected by pKa. We therefore investigated the relationship between ikmax and pKa using four imidazole derivatives at three different temperatures. The experimentally determined pKa-specific ikmax values allowed us to derive a general formula to estimate the ikmax value of any given imidazole group exhibiting a specific pKa at a specific temperature. Using the formula, the protection factors (PF), the ratio of ikmax to kmax, of five imidazole groups in dihydrofolate reductase were obtained and used to express the magnitude of their solvent accessibility. In this definition, the smaller the PF value, the higher the solvent accessibility, and a value of 1 indicates full exposure to the bulk solvent. The solvent accessibility expressed by the PF values agreed well with the solvent accessible surface areas obtained from the X-ray diffraction data.
In this work, a liquid chromatography coupled with electrospray ionization mass spectrometry (LC-ESI-MS) method was developed and validated for quantification of bile acids in fecal materials. Co-eluting matrix impurities in fecal materials have been shown to greatly suppress the ionization of analytes in mass spectrometry, which is known as the matrix effect. To correct large quantitative errors caused by the matrix effect, we developed a scheme that combined the standard addition method with internal standard (SA-IS). The fecal sample pretreatment involved a single step of extraction with ethanol. Bile acids were separated using a Luna C(18) column (150 mm, 2 mm i.d., 5 µm) with gradient elution. The deprotonated analytes were detected in selective ion monitoring mode. Our results showed that, by using this method, the accuracy of quantification was significantly improved in comparison to the conventional internal standard method. The linearity, sensitivity, accuracy and precision of the method were within the range of 0.05-5 µmol/L. This SA-IS method was successfully applied to the analysis of bile acids in the samples collected from patients diagnosed with inflammatory bowel disease.
A simple, rapid, and sensitive analytical method for the measurement of docetaxel in human plasma was developed and validated. The method is based on positive electrospray ionization tandem mass spectrometry (ESI+-MS-MS) with on-line sample extraction. It uses paclitaxel as internal standard for calibration. The on-line sample extraction minimizes sample handling and is readily adopted for automation. Quantitation of plasma docetaxel was done by the multiple reaction monitoring (MRM) mode. The method had a linear calibration range of 1.00-3000 ng/mL with a correlation coefficient >0.9999. The limit of quantitation (LOQ) for docetaxel in plasma was 1.00 ng/mL. The on-line extraction recovery of docetaxel was between 86.1-94.7%, with %CV < or = 6.1%. This method has high accuracy (90.1-96.3%), and excellent intra-assay (0.6-3.8%) and inter-assay (2.0-5.7%) precision. Its applicability to clinical samples was demonstrated by measuring patient plasma samples after treatment of weekly docetaxel at 25 mg/m2 as 60-min infusion.